期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Simultaneous imaging and measurement of tensile stress on cornea by using a common-path optical coherence tomography system with an external contact reference
1
作者 Utkarsh Sharma Jin U.Kang 《Chinese Optics Letters》 SCIE EI CAS CSCD 2008年第12期910-912,共3页
The objective of this study is to demonstrate that tensile stress resulting due to applied force on cornea can be accurately measured by using a time-domain common-path optical coherence tomography (OCT) system with... The objective of this study is to demonstrate that tensile stress resulting due to applied force on cornea can be accurately measured by using a time-domain common-path optical coherence tomography (OCT) system with an external contact reference. The unique design of the common-path OCT is utilized to set up an imaging system in which a chicken eye is placed adjacent to a glass plate serving as the external reference plane for the imaging system. As the force is applied to the chicken eye, it presses against the reference glass plate. The modified OCT image obtained is used to calculate the size of contact area, which is then used to derive the tensile stress on the cornea. The drop in signal levels upon contact of reference glass plate with the tissue are extremely sharp because of the sharp decline in reference power levels itself, thus providing us with an accurate measurement of contact area. The experimental results were in good agreement with the numerical predictions. The results of this study might be useful in providing new insights and ideas to improve the precision and safety of currently used ophthalmic surgical techniques. This research outlines a method which could be used to provide high resolution OCT images and a precise feedback of the forces applied to the cornea simultaneously. 展开更多
关键词 Simultaneous imaging and measurement of tensile stress on cornea by using a common-path optical coherence tomography system with an external contact reference
原文传递
A polynomial hybrid reflection model and measurement of its parameters based on images of sample 被引量:1
2
作者 杨磊 韩九强 《Chinese Optics Letters》 SCIE EI CAS CSCD 2007年第12期683-686,共4页
Reflectance model is a basic concept in computer vision. Some existing models combining the classical diffuse reflectance model and those for surfaces containing specular components can approximately describe real ref... Reflectance model is a basic concept in computer vision. Some existing models combining the classical diffuse reflectance model and those for surfaces containing specular components can approximately describe real reflectance. But the ratio of diffuse and specular reflection decided manually has no clear meaning. We propose a new polynomial hybrid reflectance model. The reflectance map equation with a known shape (for example cylinder) as a sample is used to estimate parameters of the proposed reflectance model by least square regression algorithm. Then the reflectance parameters for surfaces of the same class of materials can be determined. Experiments are performed for a metal surface. The synthesis images produced by the proposed method and existing ones are compared with the real acquired image, and the results show that the proposed reflectance model is suitable for describing real reflectance. 展开更多
关键词 A polynomial hybrid reflection model and measurement of its parameters based on images of sample BRDF
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部