The optical design of near-infrared phase contrast imaging(NI-PCI)diagnosis on HL-2A is introduced in this paper.This scheme benefits from the great progress of near-infrared laser technology and is a broadening of tr...The optical design of near-infrared phase contrast imaging(NI-PCI)diagnosis on HL-2A is introduced in this paper.This scheme benefits from the great progress of near-infrared laser technology and is a broadening of traditional phase contrast technology.This diagnostic can work as a keen tool to measure plasma wavenumber spectra by inferring string-integrated plasma density fluctuations.Design of both the front optical path which is the path before the laser transmitting into the tokamak plasma and the rear optics which is the path after the laser passing through the plasma is detailed.The 1550 nm laser is chosen as the probe beam and highprecision optical components are designed to fit the laser beam,in which a phase plate with a 194-nm-deep silver groove is the key.Compared with the conventional 10.6μm laser-based PCI system on HL-2A,NI-PCI significantly overcomes the unwanted phase scintillation effect and promotes the measurement capability of high-wavenumber turbulence with an increased maximal measurable wavenumber from 15 cm^(-1)to 32.6 cm^(-1).展开更多
Temporary spinal cord stimulation(tSCS)can effectively reduce the pain and severity of postherpetic neuralgia(PHN).However,there are no effective and objective methods for predicting the effects of tSCS on PHN.Laser s...Temporary spinal cord stimulation(tSCS)can effectively reduce the pain and severity of postherpetic neuralgia(PHN).However,there are no effective and objective methods for predicting the effects of tSCS on PHN.Laser speckle contrast imaging(LSCI)is frequently used in neurology to evaluate the effectiveness of treatment.To assess the accuracy of LSCI in predicting the impact of tSCS on PHN,14 adult patients receiving tSCS treatments for spinal nerve-innervated(C6-T2)PHN participated in this observational study.Visual analog scale(VAS)assessments and LSCI bloodflow images of the-ngers were recorded after the tSCS procedure.The results showed that the VAS scores of all patients decreased signi-cantly.Moreover,the bloodflow index(BFI)values were signi-cantly higher than they were before the procedure.Increased bloodflow and pain alleviation were positively correlated.The-ndings indicated that spinal nerve PHN(C6-T2)was signi-cantly reduced by tSCS.Pain alleviation by tSCS was positively correlated with increased bloodflow in the hand.The effect of tSCS on PHN may thus be predicted using an independent and consistent indicator such as LSCI.展开更多
Accurate detection of cartilage injuries is critical for their proper treatment because these injuries lack the selfhealing ability and lead to joint dysfunction.However,the low longitudinal T1 relaxivity(r1)and non-s...Accurate detection of cartilage injuries is critical for their proper treatment because these injuries lack the selfhealing ability and lead to joint dysfunction.However,the low longitudinal T1 relaxivity(r1)and non-specificity of contrast agents(such as gadolinium(III)-diethylenetriamine-pentaacetic acid(Gd-DTPA))significantly limit the efficiency of clinical magnetic resonance imaging(MRI)applications.To overcome these drawbacks,we integrated hyaluronic acid(HA)with Gd to synthesize a Gd-DTPA-HA composite,which was subsequently freeze-dried to produce nanoparticles(NPs).The resultant Gd-HA NPs demonstrated a greater r1 value(12.51 mM^-1 s^-1)compared with the bulk Gd-DTPA-HA(8.37 mM^-1 s^-1)and clinically used Gd-DTPA(3.88 mM^-1 s^-1).Moreover,the high affinity of HA to the cartilage allowed these NPs to penetrate deeper beyond the cartilage surface.As a result,Gd-HA NPs considerably increased the quality of cartilage and lesion MR images via their intra-articular injection in vivo.Specifically,2 h after NP administration,the signal-to-noise ratio at the injured cartilage site was 2.3 times greater than the value measured before the injection.In addition,Gd-HA NPs exhibited good biosafety properties due to the absence of adverse effects in the blood or on the main organs.It was also showed that Gd NPs were first metabolized by the kidney and liver and then excreted from the body with urine.Thus,Gd-HA NPs can potentially serve as an efficient MRI contrast agent for improved detection of cartilage injuries.展开更多
The present study aimed to improve the processing of data acquired from laser speckle contrast imaging(LSCI) to provide a standardization method to explore changes in regional cerebral blood flow(r CBF) and to det...The present study aimed to improve the processing of data acquired from laser speckle contrast imaging(LSCI) to provide a standardization method to explore changes in regional cerebral blood flow(r CBF) and to determine the correlations among r CBF, cerebral ischemic lesion volume and microvascular density over time in a focal ischemic region. C57BL/6J mice were subjected to focal photothrombotic(PT) ischemia. r CBF was measured using LSCI at different time points before and after PT ischemia through an intact skull. Standardized r CBF(Sr CBF), defined as the ratio of r CBF measured in the ipsilateral region of interest(ROI) to that in the corresponding contralateral region, was calculated to evaluate potential changes. In addition, the volume of the ischemic lesion and the microvascular density were determined using Nissl staining and immunofluorescence, respectively. The relationships among the ischemic lesion volume, microvascular density and Sr CBF were analyzed over time. The results showed that the cortical r CBF measured using LSCI following PT ischemia in the C57BL/6J mice gradually increased. Changes in the cerebral ischemic lesion volume were negatively correlated with Sr CBF in the ischemic region. Changes in the microvascular density were similar to those observed in Sr CBF. Our findings indicate that LSCI is a practical technique for observing changes in murine cortical r CBF without skull opening and for analyzing the relationships among the ischemic lesion volume, microvascular density and Sr CBF following focal cerebral ischemia. Preliminary results also suggest that the use of LSCI to observe the formation of collateral circulation is feasible.展开更多
The influence of ischemia-reperfusion(I/R)action on pancreatic blood flow(PBF)and the development of acute pancreatitis(AP)in laboratory rats is evaluated in vivo by using the laser speckle contrast imaging(LSCI).Addi...The influence of ischemia-reperfusion(I/R)action on pancreatic blood flow(PBF)and the development of acute pancreatitis(AP)in laboratory rats is evaluated in vivo by using the laser speckle contrast imaging(LSCI).Additionally,the optical properties in norm and under condition of AP in rats were assessed using a modied integrating sphere spectrometer and inverse Monte Carlo(IMC)software.The results of the experimental study of microcirculation of the pancreas in 82 rats in the ischemic model are presented.The data obtained conrm the fact that local ischemia and changes in the blood°ow velocity of the main vessels cause and provoke acute pancreatitis.展开更多
X-ray speckle tracking based methods can provide results with best reported angular accuracy up to 2 nrad. However,duo to the multi-frame requirement for phase retrieval and the possible instability of the x-ray beam,...X-ray speckle tracking based methods can provide results with best reported angular accuracy up to 2 nrad. However,duo to the multi-frame requirement for phase retrieval and the possible instability of the x-ray beam, mechanical and background vibration, the actual accuracy will inevitably be degraded by these time-dependent fluctuations. Therefore,not only spatial position, but also temporal features of the speckle patterns need to be considered in order to maintain the superiority of the speckle-based methods. In this paper, we propose a parallel acquisition method with advantages of real time and high accuracy, which has potential applicability to dynamic samples imaging as well as on-line beam monitoring.Through simulations, we demonstrate that the proposed method can reduce the phase error caused by the fluctuations to1% at most compared with current speckle tracking methods. Meanwhile, it can keep the accuracy deterioration within0.03 nrad, making the high theoretical accuracy a reality. Also, we find that waveforms of the incident beam have a little impact on the phase retrieved and will not influence the actual accuracy, which relaxes the requirements for speckle-based experiments.展开更多
Laser Speckle Contrast Imaging(LSCI)plays an important role in studying blood flow,but suffers from limited penetration depth of light in turbid tissue.The strong scattering of tissue obviously reduces the image contr...Laser Speckle Contrast Imaging(LSCI)plays an important role in studying blood flow,but suffers from limited penetration depth of light in turbid tissue.The strong scattering of tissue obviously reduces the image contrast which decreases the sensitivity to flow velocity.Some image processing or optical clearing methods have been proposed to lessen the deficiency,but quantitative assessment of improvement is seldom given.In this study,LSCI was applied to monitor the blood flow through a capillary embedded within various tissue phantoms at depths of 0.25,0.45,0.65,0.85 and 1.05 mm,and the flow velocity in capillary was controllable from 0 to 4mm/s.Here,glycerol,a common optical clearing agent,was mixed with Intralipid at different volume ratio to make the reduced scattering coefficient of tissue phantom decrease from 13.00 to 0.50 cm−1.The quantitative analysis demonstrates that the optical clearing method can obviously enhance the image contrast,imaging depth,and sensitivity to blood flow velocity.Comparing the Laser Speckle Contrast Analysis methods and the optical clearing method,we find that for typical turbid tissue,the sensitivity to velocity estimated by the Laser Speckle Temporal Contrast Analysis(LSTCA)is twice of that by the Laser Speckle Spatial Contrast Analysis(LSSCA);while the sensitivity to velocity estimated by using the two analysis methods has a 10-fold increase,respectively,if addition of glycerol makes the reduced scattering coefficient of tissue phantom decrease by 30%.Combining the LSTCA and the optical clearing method,the sensitivity to flow velocity will be further enhanced.展开更多
We propose and implement a wide-field vibrational phase contrast detection to obtain imaging of imaginary components of third-order nonlinear susceptibility in a coherent anti-Stokes Raman scattering (CARS) microsco...We propose and implement a wide-field vibrational phase contrast detection to obtain imaging of imaginary components of third-order nonlinear susceptibility in a coherent anti-Stokes Raman scattering (CARS) microscope with full suppression of the non-resonant background. This technique is based on the unique ability of recovering the phase of the generated CARS signal based on holographic recording. By capturing the phase distributions of the generated CARS field from the sample and from the environment under resonant illumination, we demonstrate the retrieval of imaginary components in the CARS microscope and achieve background free coherent Raman imaging.展开更多
X-ray grating interferometer has attracted widely attention in the past years due to its capability in achieving x-ray phase contrast imaging with low brilliance source. However, the widely used phase stepping informa...X-ray grating interferometer has attracted widely attention in the past years due to its capability in achieving x-ray phase contrast imaging with low brilliance source. However, the widely used phase stepping information extraction method reduces system stability and prolongs data acquisition time by several times compared with conventional x-ray absorption- based imaging. The mechanical stepping can be avoided by using a staggered grating, but at the cost of low vertical spatial resolution. In this paper, employing a modified staggered grating and the angular signal radiography, we proposed a single-shot grating-based x-ray differential phase contrast imaging with decent vertical spatial resolution. The theoretical framework was deduced and proved by numerical experiments. Absorption, phase, and scattering computed tomography can be performed without phase stepping. Therefore, we believe this fast and highly stable imaging method with decent resolution would be widely applied in x-ray grating-based phase contrast imaging.展开更多
In-line x-ray phase contrast imaging has attracted much attention due to two major advantages: its effectiveness in imaging weakly absorbing materials, and the simplicity of its facilities. In this paper a comprehens...In-line x-ray phase contrast imaging has attracted much attention due to two major advantages: its effectiveness in imaging weakly absorbing materials, and the simplicity of its facilities. In this paper a comprehensive theory based on Wigner distribution developed by Wu and Liu [Med. Phys. 31 2378-2384 (2004)] is reviewed. The influence of x-ray source and detector on the image is discussed. Experiments using a microfocus x-ray source and a CCD detector are conducted, which show the role of two key factors on imaging: the tube voltage and tube current. High tube current and moderate tube voltage are suggested for imaging.展开更多
The principle, imaging condition and experimental method for obtaining high resolution composition contrast in secondary electron image were described. A new technique of specimen preparation for secondary electron co...The principle, imaging condition and experimental method for obtaining high resolution composition contrast in secondary electron image were described. A new technique of specimen preparation for secondary electron composition contrast observation was introduced and discussed. By using multilayer P+Si1-xGex/pSi heterojunction internal photoemission infrared detector as an example, the applications of secondary electron composition contrast imaging in microstructure studies on heterojunction semiconducting materials and devices were stated. The characteristics of the image were compared with the ordinary transmission electron diffraction contrast image. The prospects of applications of the imaging method in heterojunction semiconductor devices and multilayer materials are also discussed.展开更多
Using the laser speckle contrast imaging and wavelet-based analyses,we investigate a latent("hidden")stage of the development of intracranial hemorrhages(ICHs)in newborn rats.We apply two measures based on t...Using the laser speckle contrast imaging and wavelet-based analyses,we investigate a latent("hidden")stage of the development of intracranial hemorrhages(ICHs)in newborn rats.We apply two measures based on the continuous wavelet-transform of blood flow velocity in the sagittal sinus,namely,the spectral energy in distinct frequency ranges and a multiscality degree characterizing complexity of experimental data.We show that the wavelet-based multifractal formalism reveals changes in the cerebrovascular blood flow at the development of ICH.展开更多
A fast and simple method to extract phase-contrast images from interferograms is proposed, and its effectiveness is demonstrated through simulation and experiment. For x-ray differential phase contrast imaging, a stro...A fast and simple method to extract phase-contrast images from interferograms is proposed, and its effectiveness is demonstrated through simulation and experiment. For x-ray differential phase contrast imaging, a strong attenuation signal acts as an overwhelming background intensity that obscures the weak phase signal so that no obvious phase-gradient information is detectable in the raw image. By subtracting one interferogram from another, chosen at particular intervals,the phase signal can be isolated and magnified.展开更多
The fundamental limitations of most vascular-based functional neuroimaging techniques are placed by the fact how fine the brain regulates the blood supply system.In vivo mapping of the cerebral microcirculation with h...The fundamental limitations of most vascular-based functional neuroimaging techniques are placed by the fact how fine the brain regulates the blood supply system.In vivo mapping of the cerebral microcirculation with high resolution and sensitivity hence becomes unprecedentedly compelling.This paper reviews the theoretical background of the laser speckle contrast imaging(LSCI)technique and attempts to present a complete framework stemming from a simple biophysical model.Through the sensitivity analysis,more insights into the tool optimization are attained for in vivo applications.Open questions of the technical aspects are discussed within this unified framework.Finally,it concludes with a brief perspective of future research in a way analogous to the magnetic resonance imaging(MRI)technique.Such exploration could catalyze their development and initiate a technological fusion for precise assessment of blood flow across various spatial scales.展开更多
In theory, we find that the actual function of the analyzer grating in the Talbot–Lau interferometer is segmenting the self-images of the phase grating and choosing integral areas, which make sure that each period of...In theory, we find that the actual function of the analyzer grating in the Talbot–Lau interferometer is segmenting the self-images of the phase grating and choosing integral areas, which make sure that each period of self-images in one detector pixel contributes the same signal to the detector. Furthermore, in the case of the lack of an analyzer grating, the shifting curves are still existent in theory as long as the number of fringes is non-integral in a detector pixel, which is a sufficient condition for creating shifting curve. The sufficient condition is available for not only the Talbot–Lau interferometer and the inverse geometry of Talbot–Lau interferometer, but also the x-ray phase contrast imaging system based on geometrical optics. In practical applications, we propose a method to improve the performances of the existing systems by employing the sufficient condition. This method can shorten the system length, is applicable to large period gratings, and can use the detectors with large pixels and large field of view. In addition, the experimental arrangement can be simplified due to the lack of an analyzer grating. In order to improve detection sensitivity and resolution, we also give an optimal fringe period.We believe that the theory and method proposed here is a step forward for x-ray phase contrast imaging.展开更多
A phase contrast imaging(PCI) diagnostic has recently been developed on HL-2 A tokamak. It can diagnose plasma density fluctuations with maximum wave number of 15 cm^(-1) and wave number resolution of 2 cm^(-1)....A phase contrast imaging(PCI) diagnostic has recently been developed on HL-2 A tokamak. It can diagnose plasma density fluctuations with maximum wave number of 15 cm^(-1) and wave number resolution of 2 cm^(-1). The time resolution reaches 2 μs. A 10.6 μm CO_2 laser is expanded to a beam with a diameter of 30 mm and injected into the plasma as an incident beam,injecting into plasma. The emerging scattered and unscattered beams are contrasted by a phase plate. The ideas of optical path design are presented in this paper, together with the parameters of the main optical components. The whole optical path of PCI is not only carefully designed, but also constructed on HL-2 A. First calibration results show the ability of this system to catch plasma turbulence in a wide frequency domain.展开更多
Background: Non-uniformity in signal intensity occurs commonly in magnetic resonance (MR) imaging, which may pose substantial problems when using a 3T scanner. Therefore, image non-uniformity correction is usually app...Background: Non-uniformity in signal intensity occurs commonly in magnetic resonance (MR) imaging, which may pose substantial problems when using a 3T scanner. Therefore, image non-uniformity correction is usually applied. Purpose: To compare the correction effects of the phased-array uniformity enhancement (PURE), a calibration-based image non-uniformity correction method, among three different software versions in 3T Gd-EOB-DTPA-enhanced MR imaging. Material and Methods: Hepatobiliary-phase images of a total of 120 patients who underwent Gd-EOB-DTPA-enhanced MR imaging on the same 3T scanner were analyzed retrospectively. Forty patients each were examined using three software versions (DV25, DV25.1, and DV26). The effects of PURE were compared by visual assessment, histogram analysis of liver signal intensity, evaluation of the spatial distribution of correction effects, and evaluation of quantitative indices of liver parenchymal enhancement. Results: The visual assessment indicated the highest uniformity of PURE-corrected images for DV26, followed by DV25 and DV25.1. Histogram analysis of corrected images demonstrated significantly larger variations in liver signal for DV25.1 than for the other two versions. Although PURE caused a relative increase in pixel values for central and lateral regions, such effects were weaker for DV25.1 than for the other two versions. In the evaluation of quantitative indices of liver parenchymal enhancement, the liver-to-muscle ratio (LMR) was significantly higher for the corrected images than for the uncorrected images, but the liver-to-spleen ratio (LSR) showed no significant differences. For corrected images, the LMR was significantly higher for DV25 and DV26 than for DV25.1, but the LSR showed no significant differences among the three versions. Conclusion: There were differences in the effects of PURE among the three software versions in 3T Gd-EOB-DTPA-enhanced MR imaging. Even if the non-uniformity correction method has the same brand name, correction effects may differ depending on the software version, and these differences may affect visual and quantitative evaluations.展开更多
Among five types of pulmonary hypertension,chronic thromboembolic pulmonary hypertension(CTEPH)is the only curable form,but prompt and accurate diagnosis can be challenging.Computed tomography and nuclear medicine-bas...Among five types of pulmonary hypertension,chronic thromboembolic pulmonary hypertension(CTEPH)is the only curable form,but prompt and accurate diagnosis can be challenging.Computed tomography and nuclear medicine-based techniques are standard imaging modalities to non-invasively diagnose CTEPH,however these are limited by radiation exposure,subjective qualitative bias,and lack of cardiac functional assessment.This review aims to assess the methodology,diagnostic accuracy of pulmonary perfusion imaging in the current literature and discuss its advantages,limitations and future research scope.展开更多
We propose a laser speckle contrast imaging method based on uniting spatiotemporal Fourier transform.First,the raw speckle images are entirely transformed to the spatiotemporal frequency domain with a three-dimensiona...We propose a laser speckle contrast imaging method based on uniting spatiotemporal Fourier transform.First,the raw speckle images are entirely transformed to the spatiotemporal frequency domain with a three-dimensional(3D)fast Fourier transform.Second,the dynamic and static speckle components are extracted by applying 3D low-pass and high-pass filtering in the spatiotemporal frequency domain and inverse 3D Fourier transform.Third,we calculate the time-averaged modulation depth with the average of both components to map the two-dimensional blood flow distribution.The experiments demonstrate that the proposed method could effectively improve computational efficiency and imaging quality.展开更多
AIM:To evaluate the detection and differentiation ability of contrast-enhanced intraoperative ultrasonography(CE-IOUS) in hepatocellular carcinoma(HCC) operations.METHODS:Clinical data of 50 HCC patients were retrospe...AIM:To evaluate the detection and differentiation ability of contrast-enhanced intraoperative ultrasonography(CE-IOUS) in hepatocellular carcinoma(HCC) operations.METHODS:Clinical data of 50 HCC patients were retrospective analyzed.The sensitivity,specificity,false negative and false positive rates of contrast enhanced magnetic resonance imaging(CE-MRI),IOUS and CEIOUS were calculated and compared.Surgical strategy changes due to CE-IOUS were analyzed.RESULTS:Lesions detected by CE-MRI,IOUS and CEIOUS were 60,97 and 85 respectively.The sensitivity,specificity,false negative rate,false positive rate of CEMRI were 98.2%,98.6%,98.6%,60.0%,respectively;for IOUS were 50.0%,90.9%,1.8%,1.4%,respectively;and for CE-IOUS were 1.4%,40.0%,50.0%,9.1%,respectively.The operation strategy of 9(9/50,18.0%) cases was changed according to the results of CE-IOUS.CONCLUSION:Compared with CE-MRI,CE-IOUS performs better in detection and differentiation of small metastasis and regenerative nodules.It plays an important role in the decision-making of HCC operation.展开更多
基金supported by the National Key Research and Development Program of China(Nos.2019YFE03090100 and 2022YFE03100002)National Natural Science Foundation of China(No.12075241)。
文摘The optical design of near-infrared phase contrast imaging(NI-PCI)diagnosis on HL-2A is introduced in this paper.This scheme benefits from the great progress of near-infrared laser technology and is a broadening of traditional phase contrast technology.This diagnostic can work as a keen tool to measure plasma wavenumber spectra by inferring string-integrated plasma density fluctuations.Design of both the front optical path which is the path before the laser transmitting into the tokamak plasma and the rear optics which is the path after the laser passing through the plasma is detailed.The 1550 nm laser is chosen as the probe beam and highprecision optical components are designed to fit the laser beam,in which a phase plate with a 194-nm-deep silver groove is the key.Compared with the conventional 10.6μm laser-based PCI system on HL-2A,NI-PCI significantly overcomes the unwanted phase scintillation effect and promotes the measurement capability of high-wavenumber turbulence with an increased maximal measurable wavenumber from 15 cm^(-1)to 32.6 cm^(-1).
基金supported by the Clinical Frontier Technology Program of the First A±liated Hospital of Jinan University,China(No.JNU1AFCFTP-2022-a01212)the Clinical Research Funds for the First Clinical Medicine College of Jinan University(Grant No.2018006).
文摘Temporary spinal cord stimulation(tSCS)can effectively reduce the pain and severity of postherpetic neuralgia(PHN).However,there are no effective and objective methods for predicting the effects of tSCS on PHN.Laser speckle contrast imaging(LSCI)is frequently used in neurology to evaluate the effectiveness of treatment.To assess the accuracy of LSCI in predicting the impact of tSCS on PHN,14 adult patients receiving tSCS treatments for spinal nerve-innervated(C6-T2)PHN participated in this observational study.Visual analog scale(VAS)assessments and LSCI bloodflow images of the-ngers were recorded after the tSCS procedure.The results showed that the VAS scores of all patients decreased signi-cantly.Moreover,the bloodflow index(BFI)values were signi-cantly higher than they were before the procedure.Increased bloodflow and pain alleviation were positively correlated.The-ndings indicated that spinal nerve PHN(C6-T2)was signi-cantly reduced by tSCS.Pain alleviation by tSCS was positively correlated with increased bloodflow in the hand.The effect of tSCS on PHN may thus be predicted using an independent and consistent indicator such as LSCI.
基金supported by the National Natural Science Foundation of China(81671652,81902198)National Key Research and Development Program of China(2018YFC2000205)+3 种基金Guangdong Basic and Applied Basic Research Foundation(2020A1515010398)China Postdoctoral Science Foundation(BX20190150,2019M662980)President Foundation of Zhujiang Hospital,Southern Medical University(yzjj2018rc09)Scientific Research Foundation of Southern Medical University(C1051353,PY2018N060).
文摘Accurate detection of cartilage injuries is critical for their proper treatment because these injuries lack the selfhealing ability and lead to joint dysfunction.However,the low longitudinal T1 relaxivity(r1)and non-specificity of contrast agents(such as gadolinium(III)-diethylenetriamine-pentaacetic acid(Gd-DTPA))significantly limit the efficiency of clinical magnetic resonance imaging(MRI)applications.To overcome these drawbacks,we integrated hyaluronic acid(HA)with Gd to synthesize a Gd-DTPA-HA composite,which was subsequently freeze-dried to produce nanoparticles(NPs).The resultant Gd-HA NPs demonstrated a greater r1 value(12.51 mM^-1 s^-1)compared with the bulk Gd-DTPA-HA(8.37 mM^-1 s^-1)and clinically used Gd-DTPA(3.88 mM^-1 s^-1).Moreover,the high affinity of HA to the cartilage allowed these NPs to penetrate deeper beyond the cartilage surface.As a result,Gd-HA NPs considerably increased the quality of cartilage and lesion MR images via their intra-articular injection in vivo.Specifically,2 h after NP administration,the signal-to-noise ratio at the injured cartilage site was 2.3 times greater than the value measured before the injection.In addition,Gd-HA NPs exhibited good biosafety properties due to the absence of adverse effects in the blood or on the main organs.It was also showed that Gd NPs were first metabolized by the kidney and liver and then excreted from the body with urine.Thus,Gd-HA NPs can potentially serve as an efficient MRI contrast agent for improved detection of cartilage injuries.
基金supported by the National Natural Science Foundation of China(No.81271407)
文摘The present study aimed to improve the processing of data acquired from laser speckle contrast imaging(LSCI) to provide a standardization method to explore changes in regional cerebral blood flow(r CBF) and to determine the correlations among r CBF, cerebral ischemic lesion volume and microvascular density over time in a focal ischemic region. C57BL/6J mice were subjected to focal photothrombotic(PT) ischemia. r CBF was measured using LSCI at different time points before and after PT ischemia through an intact skull. Standardized r CBF(Sr CBF), defined as the ratio of r CBF measured in the ipsilateral region of interest(ROI) to that in the corresponding contralateral region, was calculated to evaluate potential changes. In addition, the volume of the ischemic lesion and the microvascular density were determined using Nissl staining and immunofluorescence, respectively. The relationships among the ischemic lesion volume, microvascular density and Sr CBF were analyzed over time. The results showed that the cortical r CBF measured using LSCI following PT ischemia in the C57BL/6J mice gradually increased. Changes in the cerebral ischemic lesion volume were negatively correlated with Sr CBF in the ischemic region. Changes in the microvascular density were similar to those observed in Sr CBF. Our findings indicate that LSCI is a practical technique for observing changes in murine cortical r CBF without skull opening and for analyzing the relationships among the ischemic lesion volume, microvascular density and Sr CBF following focal cerebral ischemia. Preliminary results also suggest that the use of LSCI to observe the formation of collateral circulation is feasible.
基金the nancial sup-port of the Project No.13.2251.21.0009 of the Ministry of Science and Higher Education of the Russian Federation.
文摘The influence of ischemia-reperfusion(I/R)action on pancreatic blood flow(PBF)and the development of acute pancreatitis(AP)in laboratory rats is evaluated in vivo by using the laser speckle contrast imaging(LSCI).Additionally,the optical properties in norm and under condition of AP in rats were assessed using a modied integrating sphere spectrometer and inverse Monte Carlo(IMC)software.The results of the experimental study of microcirculation of the pancreas in 82 rats in the ischemic model are presented.The data obtained conrm the fact that local ischemia and changes in the blood°ow velocity of the main vessels cause and provoke acute pancreatitis.
基金supported by the National Natural Science Foundation of China (Grant Nos. 11675253 and 11505278)。
文摘X-ray speckle tracking based methods can provide results with best reported angular accuracy up to 2 nrad. However,duo to the multi-frame requirement for phase retrieval and the possible instability of the x-ray beam, mechanical and background vibration, the actual accuracy will inevitably be degraded by these time-dependent fluctuations. Therefore,not only spatial position, but also temporal features of the speckle patterns need to be considered in order to maintain the superiority of the speckle-based methods. In this paper, we propose a parallel acquisition method with advantages of real time and high accuracy, which has potential applicability to dynamic samples imaging as well as on-line beam monitoring.Through simulations, we demonstrate that the proposed method can reduce the phase error caused by the fluctuations to1% at most compared with current speckle tracking methods. Meanwhile, it can keep the accuracy deterioration within0.03 nrad, making the high theoretical accuracy a reality. Also, we find that waveforms of the incident beam have a little impact on the phase retrieved and will not influence the actual accuracy, which relaxes the requirements for speckle-based experiments.
基金supported by the National Natural Science Foundation(Grant Nos.30770552,60828009 and 30911120074)of China.
文摘Laser Speckle Contrast Imaging(LSCI)plays an important role in studying blood flow,but suffers from limited penetration depth of light in turbid tissue.The strong scattering of tissue obviously reduces the image contrast which decreases the sensitivity to flow velocity.Some image processing or optical clearing methods have been proposed to lessen the deficiency,but quantitative assessment of improvement is seldom given.In this study,LSCI was applied to monitor the blood flow through a capillary embedded within various tissue phantoms at depths of 0.25,0.45,0.65,0.85 and 1.05 mm,and the flow velocity in capillary was controllable from 0 to 4mm/s.Here,glycerol,a common optical clearing agent,was mixed with Intralipid at different volume ratio to make the reduced scattering coefficient of tissue phantom decrease from 13.00 to 0.50 cm−1.The quantitative analysis demonstrates that the optical clearing method can obviously enhance the image contrast,imaging depth,and sensitivity to blood flow velocity.Comparing the Laser Speckle Contrast Analysis methods and the optical clearing method,we find that for typical turbid tissue,the sensitivity to velocity estimated by the Laser Speckle Temporal Contrast Analysis(LSTCA)is twice of that by the Laser Speckle Spatial Contrast Analysis(LSSCA);while the sensitivity to velocity estimated by using the two analysis methods has a 10-fold increase,respectively,if addition of glycerol makes the reduced scattering coefficient of tissue phantom decrease by 30%.Combining the LSTCA and the optical clearing method,the sensitivity to flow velocity will be further enhanced.
基金Supported by the National Natural Science Foundation of China under Grant Nos 11174019,61322509 and 11121091the National Basic Research Program of China under Grant No 2013CB921904
文摘We propose and implement a wide-field vibrational phase contrast detection to obtain imaging of imaginary components of third-order nonlinear susceptibility in a coherent anti-Stokes Raman scattering (CARS) microscope with full suppression of the non-resonant background. This technique is based on the unique ability of recovering the phase of the generated CARS signal based on holographic recording. By capturing the phase distributions of the generated CARS field from the sample and from the environment under resonant illumination, we demonstrate the retrieval of imaginary components in the CARS microscope and achieve background free coherent Raman imaging.
基金supported by the National Natural Science Foundation of China(Grant Nos.11275204,11475175,and 11405175)the China Postdoctoral Science Foundation(Grant No.2017M612097)the Fundamental Research Funds for the Central Universities(Grant No.WK2310000065)
文摘X-ray grating interferometer has attracted widely attention in the past years due to its capability in achieving x-ray phase contrast imaging with low brilliance source. However, the widely used phase stepping information extraction method reduces system stability and prolongs data acquisition time by several times compared with conventional x-ray absorption- based imaging. The mechanical stepping can be avoided by using a staggered grating, but at the cost of low vertical spatial resolution. In this paper, employing a modified staggered grating and the angular signal radiography, we proposed a single-shot grating-based x-ray differential phase contrast imaging with decent vertical spatial resolution. The theoretical framework was deduced and proved by numerical experiments. Absorption, phase, and scattering computed tomography can be performed without phase stepping. Therefore, we believe this fast and highly stable imaging method with decent resolution would be widely applied in x-ray grating-based phase contrast imaging.
基金Project supported by the National Natural Science Foundation of China (Grant No 10475044).
文摘In-line x-ray phase contrast imaging has attracted much attention due to two major advantages: its effectiveness in imaging weakly absorbing materials, and the simplicity of its facilities. In this paper a comprehensive theory based on Wigner distribution developed by Wu and Liu [Med. Phys. 31 2378-2384 (2004)] is reviewed. The influence of x-ray source and detector on the image is discussed. Experiments using a microfocus x-ray source and a CCD detector are conducted, which show the role of two key factors on imaging: the tube voltage and tube current. High tube current and moderate tube voltage are suggested for imaging.
文摘The principle, imaging condition and experimental method for obtaining high resolution composition contrast in secondary electron image were described. A new technique of specimen preparation for secondary electron composition contrast observation was introduced and discussed. By using multilayer P+Si1-xGex/pSi heterojunction internal photoemission infrared detector as an example, the applications of secondary electron composition contrast imaging in microstructure studies on heterojunction semiconducting materials and devices were stated. The characteristics of the image were compared with the ordinary transmission electron diffraction contrast image. The prospects of applications of the imaging method in heterojunction semiconductor devices and multilayer materials are also discussed.
基金This work was supported by the Russian Science Foundation(Agreement 14-15-00128).
文摘Using the laser speckle contrast imaging and wavelet-based analyses,we investigate a latent("hidden")stage of the development of intracranial hemorrhages(ICHs)in newborn rats.We apply two measures based on the continuous wavelet-transform of blood flow velocity in the sagittal sinus,namely,the spectral energy in distinct frequency ranges and a multiscality degree characterizing complexity of experimental data.We show that the wavelet-based multifractal formalism reveals changes in the cerebrovascular blood flow at the development of ICH.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.61101175,61571305,and 61227802)
文摘A fast and simple method to extract phase-contrast images from interferograms is proposed, and its effectiveness is demonstrated through simulation and experiment. For x-ray differential phase contrast imaging, a strong attenuation signal acts as an overwhelming background intensity that obscures the weak phase signal so that no obvious phase-gradient information is detectable in the raw image. By subtracting one interferogram from another, chosen at particular intervals,the phase signal can be isolated and magnified.
基金supported by grant 358/04-3 of“The Israeli Science Foundation”.
文摘The fundamental limitations of most vascular-based functional neuroimaging techniques are placed by the fact how fine the brain regulates the blood supply system.In vivo mapping of the cerebral microcirculation with high resolution and sensitivity hence becomes unprecedentedly compelling.This paper reviews the theoretical background of the laser speckle contrast imaging(LSCI)technique and attempts to present a complete framework stemming from a simple biophysical model.Through the sensitivity analysis,more insights into the tool optimization are attained for in vivo applications.Open questions of the technical aspects are discussed within this unified framework.Finally,it concludes with a brief perspective of future research in a way analogous to the magnetic resonance imaging(MRI)technique.Such exploration could catalyze their development and initiate a technological fusion for precise assessment of blood flow across various spatial scales.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.11074172 and 11674232)the National Key Basic Research Program,China(Grant No.2012CB825804)the National Special Foundation for Major Science Instrument,China(Grant No.61227802)
文摘In theory, we find that the actual function of the analyzer grating in the Talbot–Lau interferometer is segmenting the self-images of the phase grating and choosing integral areas, which make sure that each period of self-images in one detector pixel contributes the same signal to the detector. Furthermore, in the case of the lack of an analyzer grating, the shifting curves are still existent in theory as long as the number of fringes is non-integral in a detector pixel, which is a sufficient condition for creating shifting curve. The sufficient condition is available for not only the Talbot–Lau interferometer and the inverse geometry of Talbot–Lau interferometer, but also the x-ray phase contrast imaging system based on geometrical optics. In practical applications, we propose a method to improve the performances of the existing systems by employing the sufficient condition. This method can shorten the system length, is applicable to large period gratings, and can use the detectors with large pixels and large field of view. In addition, the experimental arrangement can be simplified due to the lack of an analyzer grating. In order to improve detection sensitivity and resolution, we also give an optimal fringe period.We believe that the theory and method proposed here is a step forward for x-ray phase contrast imaging.
基金supported by the National Magnetic Confinement Fusion Energy Research Project(Grant Nos.2015GB120002,2013GB107000,2012GB101001)National Natural Science Foundation of China(Grant Nos.11375053,11535013)the Natural Science Foundation of Anhui Province(Grant No.1608085MA08)
文摘A phase contrast imaging(PCI) diagnostic has recently been developed on HL-2 A tokamak. It can diagnose plasma density fluctuations with maximum wave number of 15 cm^(-1) and wave number resolution of 2 cm^(-1). The time resolution reaches 2 μs. A 10.6 μm CO_2 laser is expanded to a beam with a diameter of 30 mm and injected into the plasma as an incident beam,injecting into plasma. The emerging scattered and unscattered beams are contrasted by a phase plate. The ideas of optical path design are presented in this paper, together with the parameters of the main optical components. The whole optical path of PCI is not only carefully designed, but also constructed on HL-2 A. First calibration results show the ability of this system to catch plasma turbulence in a wide frequency domain.
文摘Background: Non-uniformity in signal intensity occurs commonly in magnetic resonance (MR) imaging, which may pose substantial problems when using a 3T scanner. Therefore, image non-uniformity correction is usually applied. Purpose: To compare the correction effects of the phased-array uniformity enhancement (PURE), a calibration-based image non-uniformity correction method, among three different software versions in 3T Gd-EOB-DTPA-enhanced MR imaging. Material and Methods: Hepatobiliary-phase images of a total of 120 patients who underwent Gd-EOB-DTPA-enhanced MR imaging on the same 3T scanner were analyzed retrospectively. Forty patients each were examined using three software versions (DV25, DV25.1, and DV26). The effects of PURE were compared by visual assessment, histogram analysis of liver signal intensity, evaluation of the spatial distribution of correction effects, and evaluation of quantitative indices of liver parenchymal enhancement. Results: The visual assessment indicated the highest uniformity of PURE-corrected images for DV26, followed by DV25 and DV25.1. Histogram analysis of corrected images demonstrated significantly larger variations in liver signal for DV25.1 than for the other two versions. Although PURE caused a relative increase in pixel values for central and lateral regions, such effects were weaker for DV25.1 than for the other two versions. In the evaluation of quantitative indices of liver parenchymal enhancement, the liver-to-muscle ratio (LMR) was significantly higher for the corrected images than for the uncorrected images, but the liver-to-spleen ratio (LSR) showed no significant differences. For corrected images, the LMR was significantly higher for DV25 and DV26 than for DV25.1, but the LSR showed no significant differences among the three versions. Conclusion: There were differences in the effects of PURE among the three software versions in 3T Gd-EOB-DTPA-enhanced MR imaging. Even if the non-uniformity correction method has the same brand name, correction effects may differ depending on the software version, and these differences may affect visual and quantitative evaluations.
文摘Among five types of pulmonary hypertension,chronic thromboembolic pulmonary hypertension(CTEPH)is the only curable form,but prompt and accurate diagnosis can be challenging.Computed tomography and nuclear medicine-based techniques are standard imaging modalities to non-invasively diagnose CTEPH,however these are limited by radiation exposure,subjective qualitative bias,and lack of cardiac functional assessment.This review aims to assess the methodology,diagnostic accuracy of pulmonary perfusion imaging in the current literature and discuss its advantages,limitations and future research scope.
基金supported by the Natural Science Foundation of Fujian Province(No.2021J01321)the State Key Laboratory of Integrated Optoelectronics(No.IOSKL2020KF25)。
文摘We propose a laser speckle contrast imaging method based on uniting spatiotemporal Fourier transform.First,the raw speckle images are entirely transformed to the spatiotemporal frequency domain with a three-dimensional(3D)fast Fourier transform.Second,the dynamic and static speckle components are extracted by applying 3D low-pass and high-pass filtering in the spatiotemporal frequency domain and inverse 3D Fourier transform.Third,we calculate the time-averaged modulation depth with the average of both components to map the two-dimensional blood flow distribution.The experiments demonstrate that the proposed method could effectively improve computational efficiency and imaging quality.
文摘AIM:To evaluate the detection and differentiation ability of contrast-enhanced intraoperative ultrasonography(CE-IOUS) in hepatocellular carcinoma(HCC) operations.METHODS:Clinical data of 50 HCC patients were retrospective analyzed.The sensitivity,specificity,false negative and false positive rates of contrast enhanced magnetic resonance imaging(CE-MRI),IOUS and CEIOUS were calculated and compared.Surgical strategy changes due to CE-IOUS were analyzed.RESULTS:Lesions detected by CE-MRI,IOUS and CEIOUS were 60,97 and 85 respectively.The sensitivity,specificity,false negative rate,false positive rate of CEMRI were 98.2%,98.6%,98.6%,60.0%,respectively;for IOUS were 50.0%,90.9%,1.8%,1.4%,respectively;and for CE-IOUS were 1.4%,40.0%,50.0%,9.1%,respectively.The operation strategy of 9(9/50,18.0%) cases was changed according to the results of CE-IOUS.CONCLUSION:Compared with CE-MRI,CE-IOUS performs better in detection and differentiation of small metastasis and regenerative nodules.It plays an important role in the decision-making of HCC operation.