Internal solitary waves(ISWs)change the roughness of the sea surface,thus producing dark and bright bands in optical images.However,reasons for changes in imaging characteristics with the solar zenith angle remain unc...Internal solitary waves(ISWs)change the roughness of the sea surface,thus producing dark and bright bands in optical images.However,reasons for changes in imaging characteristics with the solar zenith angle remain unclear.In this paper,the optical imaging pattern of ISWs in sunglint under different zenith angles of the light source is investigated by collecting optical images of ISWs through physical simulation.The experiment involves setting 10 zenith angles of the light source,which are divided into area a the optical images of ISWs in the three areas show dark-bright mode,single bright band,and bright-dark mode,which are consistent with those observed by optical remote sensing.In addition,this study analyzed the percentage of the dark and bright areas of the bands and the change in the relative gray difference and found changes in both areas under different zenith angles of the light source.The MODIS and ASAR images display a similar brightness-darkness distance of the same ISWs.Therefore,the relationship between the brightness-darkness distance and the characteristic half-width of ISWs is determined in accordance with the eKdV theory and the imaging mechanism of ISWs of the SAR image.Overall,the relationship between them in the experiment is almost consistent with the theoretical result.展开更多
In a single-pixel fast imaging setup,the data collected by the single-pixel detector needs to be processed by a computer,but the speed of the latter will affect the image reconstruction time.Here we propose two kinds ...In a single-pixel fast imaging setup,the data collected by the single-pixel detector needs to be processed by a computer,but the speed of the latter will affect the image reconstruction time.Here we propose two kinds of setups which are able to transform non-visible into visible light imaging,wherein their computing process is replaced by a camera integration mode.The image captured by the camera has a low contrast,so here we present an algorithm that can realize a high quality image in near-infrared to visible cross-waveband imaging.The scheme is verified both by simulation and in actual experiments.The setups demonstrate the great potential for single-pixel imaging and high-speed cross-waveband imaging for future practical applications.展开更多
Silica nanoparticles have been one of the most promising nanosystems for biomedical applications due to their facile surface chemistry and non-toxic nature. However, it is still challenging to effectively deliver them...Silica nanoparticles have been one of the most promising nanosystems for biomedical applications due to their facile surface chemistry and non-toxic nature. However, it is still challenging to effectively deliver them into tumor sites and noninvasively visualize their in vivo biodistribution with excellent sensitivity and accuracy for effective cancer diagnosis. In this study, we design a yolk/shell-structured silica nanosystem ^(64) Cu-NOTAQD@HMSN-PEG-TRC105, which can be employed for tumor vasculature targeting and dual-modality PET/optical imaging, leading to superior targeting specificity, excellentimaging capability and more reliable diagnostic outcomes.By combining vasculature targeting, pH-sensitive drug delivery, and dual-modality imaging into a single platform,as-designed yolk/shell-structured silica nanosystems may be employed for the future image-guided tumor-targeted drug delivery, to further enable cancer theranostics.展开更多
Real-time polarization medium-wave infrared(MIR)optical imaging systems enable the acquisition of infrared and polarization information for a target.At present,real-time polarization MIR devices face the following pro...Real-time polarization medium-wave infrared(MIR)optical imaging systems enable the acquisition of infrared and polarization information for a target.At present,real-time polarization MIR devices face the following problems:poor real-time performance,low transmission and high requirements for fabrication and integration.Herein,we aim to improve the performance of real-time polarization imaging systems in the MIR waveband and solve the above-mentioned defects.Therefore,we propose a MIR polarization imaging system to achieve real-time polarization-modulated imaging with high transmission as well as improved performance based on a pixel-wise metasurface micro-polarization array(PMMPA).The PMMPA element comprises several linear polarization(LP)filters with different polarization angles.The optimization results demonstrate that the transmittance of the center field of view for the LP filters is up to 77%at a wavelength of4.0μm and an extinction ratio of 88 d B.In addition,a near-diffraction-limited real-time MIR imaging optical system is designed with a field of view of 5°and an F-number of 2.The simulation results show that an MIR polarization imaging system with excellent real-time performance and high transmission is achieved by using the optimized PMMPA element.Therefore,the method is compatible with the available optical system design technologies and provides a way to realize real-time polarization imaging in MIR wavebands.展开更多
A model based on Fourier domain consideration on aperture configuration of optical synthetic aperture imaging system is introduced in this paper. The derivation of the model is directly linked to the restoration error...A model based on Fourier domain consideration on aperture configuration of optical synthetic aperture imaging system is introduced in this paper. The derivation of the model is directly linked to the restoration error of the original object from the recorded image. The aperture configuration is a function of the maximum frequency of interest, and takes into account the diameter of the aperture. The simulative results of genetic algorithms illustrate the usefulness of this model lot designing a synthetic aperture optical imaging system, and the aperture configuration of a good synthetic aperture optical imaging system should be non-redundant.展开更多
Computational optical imaging is an interdisciplinary subject integrating optics, mathematics, and information technology. It introduces information processing into optical imaging and combines it with intelligent com...Computational optical imaging is an interdisciplinary subject integrating optics, mathematics, and information technology. It introduces information processing into optical imaging and combines it with intelligent computing, subverting the imaging mechanism of traditional optical imaging which only relies on orderly information transmission. To meet the high-precision requirements of traditional optical imaging for optical processing and adjustment, as well as to solve its problems of being sensitive to gravity and temperature in use, we establish an optical imaging system model from the perspective of computational optical imaging and studies how to design and solve the imaging consistency problem of optical system under the influence of gravity, thermal effect, stress, and other external environment to build a high robustness optical system. The results show that the high robustness interval of the optical system exists and can effectively reduce the sensitivity of the optical system to the disturbance of each link, thus realizing the high robustness of optical imaging.展开更多
Based on a strong inter-diagonal matrix and Taylor series expansions,an oversample reconstruction method was proposed to calibrate the optical micro-scanning error. The technique can obtain regular 2 ×2 microscan...Based on a strong inter-diagonal matrix and Taylor series expansions,an oversample reconstruction method was proposed to calibrate the optical micro-scanning error. The technique can obtain regular 2 ×2 microscanning undersampling images from the real irregular undersampling images,and can then obtain a high spatial oversample resolution image. Simulations and experiments show that the proposed technique can reduce optical micro-scanning error and improve the system's spatial resolution. The algorithm is simple,fast and has low computational complexity. It can also be applied to other electro-optical imaging systems to improve their spatial resolution and has a widespread application prospect.展开更多
AIM: To investigate the molecular or cellular mechanisms related to the infection of epithelial colonic mucosa by pks-positive Escherichia coli(E. coli) using optical imaging.METHODS: We choose to evaluate the tumor m...AIM: To investigate the molecular or cellular mechanisms related to the infection of epithelial colonic mucosa by pks-positive Escherichia coli(E. coli) using optical imaging.METHODS: We choose to evaluate the tumor metabolic activity using a fluorodeoxyglucose analogue as 2-deoxyglucosone fluorescent probes and to correlate it with tumoral volume(mm^3). Inflammation measuring myeloperoxidase(MPO) activity and reactive oxygen species production was monitored by a bioluminescent(BLI) inflammation probe and related to histological examination and MPO levels by enzyme-linked immunosorbent assay(ELISA) on tumor specimens. The detection and quantitation of these two signals were validated on a xenograft model of human colon adenocarcinoma epithelial cells(HCT116) in nude mice infected with a pks-positive E. coli. The inflammatory BLI signal was validated intra-digestively in the colitisCEABAC10 DSS models, which mimicked Crohn's disease. RESULTS: Using a 2-deoxyglucosone fluorescent probe, we observed a high and specific HCT116 tumor uptake in correlation with tumoral volume(P = 0.0036). Using the inflammation probe targeting MPO, we detected a rapid systemic elimination and a significant increase of the BLI signal in the pks-positive E. coli-infected HCT116 xenograft group(P < 0.005). ELISA confirmed that MPO levels were significantly higher(1556 ± 313.6 vs 234.6 ± 121.6 ng/m L P = 0.001) in xenografts infected with the pathogenic E. coli strain. Moreover, histological examination of tumor samples confirmed massive infiltration of pks-positive E. coli-infected HCT116 tumors by inflammatory cells compared to the uninfected group. These data showed that infection with the pathogenic E. coli strain enhanced inflammation and ROS production in tumors before tumor growth. Moreover, we demonstrated that the intra-digestive monitoring of inflammation is feasible in a reference colitis murine model(CEABAC10/DSS).CONCLUSION: Using BLI and fluorescence optical imaging, we provided tools to better understand hostpathogen interactions at the early stage of disease, such as inflammatory bowel disease and colorectal cancer.展开更多
AIM:To assess peripapillary retinal nerve fiber layer(RNFL)and choroidal thickness obtained with enhanced depth imaging(EDI)mode compared with those obtained without EDI mode using Heidelberg Spectralis optical c...AIM:To assess peripapillary retinal nerve fiber layer(RNFL)and choroidal thickness obtained with enhanced depth imaging(EDI)mode compared with those obtained without EDI mode using Heidelberg Spectralis optical coherence tomography(OCT).METHODS:Fifty eyes of 25 normal healthy subjects and32 eyes of 20 patients with different eye diseases were included in the study.All subjects underwent 3.4 mm diameter peripapillary circular OCT scan centered on the optic disc using both the conventional and the EDI OCT protocols.The visualization of RNFL and choroidoscleral junction was assessed using an ordinal scoring scale.The paired t-test,intraclass correlation coefficient(ICC),95%limits of agreement(LoA),and Bland and Altman plots were used to test the agreement of measurements.RESULTS:The visibility score of RNFL obtained with and without EDI was of no significant difference(P=0.532),the visualization of choroidoscleral junction was better using EDI protocol than conventional protocol(P〈0.001).Peripapillary RNFL thickness obtained with EDI was slightly thicker than that obtained without EDI(103.25±9.42μm vs 101.87±8.78μm,P=0.010).The ICC of the two protocols was excellent with the value of 0.867 to 0.924,the 95%LoA of global RNFL thickness was between-10.0 to 7.4μm.Peripapillary choroidal thickness obtained with EDI was slightly thinner than that obtained without EDI(147.23±51.04μm vs 150.90±51.84μm,P〈0.001).The ICC was also excellent with the value of 0.960 to 0.987,the 95%LoA of global choroidal thickness was between-12.5 to 19.8μm.CONCLUSION:Peripapillary circular OCT scan with or without EDI mode shows comparable results in the measurement of peripapillary RNFL and choroidal thickness.展开更多
Recent years have seen the design and implementation of many optical activatable smart probes.These probes are activatable because they change their optical properties and are smart because they can identify specific ...Recent years have seen the design and implementation of many optical activatable smart probes.These probes are activatable because they change their optical properties and are smart because they can identify specific targets.This broad class of detection agents has allowed previously unperformed visualizations,facilitating the study of diverse biomolecules including enzymes,nucleic acids,ions and reactive oxygen species.Designed to be robust in an in vivo environment,these probes have been used in tissue culture cells and in live small animals.An emerging class of smart probes has been designed to harness the potency of singlet oxygen generating photosensitizers.Combining the discrimination of activatable agents with the toxicity of photosensitizers represents a new and powerful approach to disease treatment.This review highlights some applications of activatable smart probes with a focus on developments of the past decade.展开更多
Cutting-edge technologies in optical molecular imaging have ushered in new frontiers in cancer research, clinical translation, and medical practice, as evidenced by recent advances in optical multimodality imaging, Ce...Cutting-edge technologies in optical molecular imaging have ushered in new frontiers in cancer research, clinical translation, and medical practice, as evidenced by recent advances in optical multimodality imaging, Cerenkov luminescence imaging(CLI), and optical imageguided surgeries. New abilities allow in vivo cancer imaging with sensitivity and accuracy that are unprecedented in conventional imaging approaches. The visualization of cellular and molecular behaviors and events within tumors in living subjects is improving our deeper understanding of tumors at a systems level. These advances are being rapidly used to acquire tumor-to-tumor molecular heterogeneity, both dynamically and quantitatively, as well as to achieve more effective therapeutic interventions with the assistance of real-time imaging. In the era of molecular imaging, optical technologies hold great promise to facilitate the development of highly sensitive cancer diagnoses as well as personalized patient treatment—one of the ultimate goals of precision medicine.展开更多
High resolution imaging is achieved using increasingly larger apertures and successively shorter wavelengths.Optical aperture synthesis is an important high-resolution imaging technology used in astronomy.Conventional...High resolution imaging is achieved using increasingly larger apertures and successively shorter wavelengths.Optical aperture synthesis is an important high-resolution imaging technology used in astronomy.Conventional long baseline amplitude interferometry is susceptible to uncontrollable phase fluctuations,and the technical difficulty increases rapidly as the wavelength decreases.The intensity interferometry inspired by HBT experiment is essentially insensitive to phase fluctuations,but suffers from a narrow spectral bandwidth which results in a lack of effective photons.In this study,we propose optical synthetic aperture imaging based on spatial intensity interferometry.This not only realizes diffraction-limited optical aperture synthesis in a single shot,but also enables imaging with a wide spectral bandwidth,which greatly improves the optical energy efficiency of intensity interferometry.And this method is insensitive to the optical path difference between the sub-apertures.Simulations and experiments present optical aperture synthesis diffraction-limited imaging through spatial intensity interferometry in a 100 nm spectral width of visible light,whose maximum optical path difference between the sub-apertures reaches 69λ.This technique is expected to provide a solution for optical aperture synthesis over kilometer-long baselines at optical wavelengths.展开更多
Even in the early stage,endocrine metabolism disease may lead to micro aneurysms in retinal capillaries whose diameters are less than 10 μm.However,the fundus cameras used in clinic diagnosis can only obtain images o...Even in the early stage,endocrine metabolism disease may lead to micro aneurysms in retinal capillaries whose diameters are less than 10 μm.However,the fundus cameras used in clinic diagnosis can only obtain images of vessels larger than 20 μm in diameter.The human retina is a thin and multiple layer tissue,and the layer of capillaries less than10 μm in diameter only exists in the inner nuclear layer.The layer thickness of capillaries less than 10 μm in diameter is about 40 μm and the distance range to rod&cone cell surface is tens of micrometers,which varies from person to person.Therefore,determining reasonable capillary layer(CL) position in different human eyes is very difficult.In this paper,we propose a method to determine the position of retinal CL based on the rod&cone cell layer.The public positions of CL are recognized with 15 subjects from 40 to 59 years old,and the imaging planes of CL are calculated by the effective focal length of the human eye.High resolution retinal capillary imaging results obtained from 17 subjects with a liquid crystal adaptive optics system(LCAOS) validate our method.All of the subjects' CLs have public positions from 127 μm to 147 μm from the rod&cone cell layer,which is influenced by the depth of focus.展开更多
In liver tumor surgery,the recognition of tumor margin and radical resection of microcancer focis have always been the crucial points to reduce postoperative recurrence of tumor.However,naked-eye inspection and palpat...In liver tumor surgery,the recognition of tumor margin and radical resection of microcancer focis have always been the crucial points to reduce postoperative recurrence of tumor.However,naked-eye inspection and palpation have limited effectiveness in identifying tumor boundaries,and traditional imaging techniques cannot consistently locate tumors in real time.As an intraoperative real-time navigation imaging method,NIRfluorescence imaging has been extensively studied for its simplicity,reliable safety,and superior sensitivity,and is expected to improve the accuracy of liver tumor surgery.In recent years,the research focus of NIRfluorescence has gradually shifted from the-rst near-infrared window(NIR-I,700–900 nm)to the second near-infrared window(NIR-II,1000–1700 nm).Fluorescence imaging in NIR-II reduces the scattering effect of deep tissue,providing a preferable detection depth and spatial resolution while signi-cantly eliminating liver autofluorescence background to clarify tumor margin.Developingfluorophores combined with tumor antibodies will further improve the precision offluorescence-guided surgical navigation.With the development of a bunch offluorophores with phototherapy ability,NIR-II can integrate tumor detection and treatment to explore a new therapeutic strategy for liver cancer.Here,we review the recent progress of NIR-IIfluorescence technology in liver tumor surgery and discuss its challenges and potential development direction.展开更多
AIM:To characterize spectral-domain optical coherence tomography(SD-OCT)features of chorioretinal folds in orbital mass imaged using enhanced depth imaging(EDI).METHODS:Prospective observational case-control study was...AIM:To characterize spectral-domain optical coherence tomography(SD-OCT)features of chorioretinal folds in orbital mass imaged using enhanced depth imaging(EDI).METHODS:Prospective observational case-control study was conducted in 20 eyes of 20 patients,the uninvolved eye served as a control.All the patients underwent clinical fundus photography,computed tomography,EDI SDOCT imaging before and after surgery.Two patients with cavernous hemangiomas underwent intratumoral injection of bleomycin A5;the remaining patients underwent tumor excision.Patients were followed 1 to 14mo following surgery(average follow up,5.8mo).RESULTS:Visual acuity prior to surgery ranged from 20/20 to 20/200.Following surgery,5 patients’visual acuity remained unchanged while the remaining 15 patients had a mean letter improvement of 10(range 4 to 26 letters).Photoreceptor inner/outer segment defects were found in 10 of 15 patients prior to surgery.Following surgical excision,photoreceptor inner/outer segment defects fully resolved in 8 of these 10 patients.CONCLUSION:Persistence of photoreceptor inner/outer segment defects caused by compression of the globe by an orbital mass can be associated with reduced visual prognosis.Our findings suggest that photoreceptor inner/outer segment defects on EDI SD-OCT could be an indicator for immediate surgical excision of an orbital mass causing choroidal compression.展开更多
AIM:To evaluate the peripapillary choroidal thickness(PPCT) in Chinese children,and to analyze the influencing factors.METHODS: PPCT was measured with enhanced depth imaging optical coherence tomography(EDI-OCT)...AIM:To evaluate the peripapillary choroidal thickness(PPCT) in Chinese children,and to analyze the influencing factors.METHODS: PPCT was measured with enhanced depth imaging optical coherence tomography(EDI-OCT) in 70children(53 myopes and 17 non-myopes) aged 7 to 18 y,with spherical equivalent refractive errors between 0.50and-5.87 diopters(D).Peripapillary choroidal imaging was performed using circular scans of a diameter of 3.4 mm around the optic disc.PPCT was measured by EDI-OCT in six sectors: nasal(N),superonasal(SN),superotemporal(ST),temporal(T),inferotemporal(IT)and inferonasal(IN),as well as global RNFL thickness(G).RESULTS: The mean global PPCT was 165.49±33.76 μm.The temporal,inferonasal,inferotemporal PPCT were significantly thinner than the nasal,superonasal,superotemporal segments PPCT were significantly thinner in the myopic group at temporal,superotemporal and inferotemporal segments.The axial length was significantly associated with the average global(β=-0.419,P =0.014),superonasal(β=-2.009,P=0.049) and inferonasal(β=-2.000,P=0.049) PPCT.The other factors(gender,age,SE) were not significantly associated with PPCT.CONCLUSION: PPCT was thinner in the myopic group at temporal,superotemporal and inferotemporal segments.The axial length was found to be negatively correlated to PPCT.We need more further studies about the relationship between PPCT and myopia.展开更多
Some existing image encryption schemes use simple low-dimensional chaotic systems, which makes the algorithms insecure and vulnerable to brute force attacks and cracking. Some algorithms have issues such as weak corre...Some existing image encryption schemes use simple low-dimensional chaotic systems, which makes the algorithms insecure and vulnerable to brute force attacks and cracking. Some algorithms have issues such as weak correlation with plaintext images, poor image reconstruction quality, and low efficiency in transmission and storage. To solve these issues,this paper proposes an optical image encryption algorithm based on a new four-dimensional memristive hyperchaotic system(4D MHS) and compressed sensing(CS). Firstly, this paper proposes a new 4D MHS, which has larger key space, richer dynamic behavior, and more complex hyperchaotic characteristics. The introduction of CS can reduce the image size and the transmission burden of hardware devices. The introduction of double random phase encoding(DRPE) enables this algorithm has the ability of parallel data processing and multi-dimensional coding space, and the hyperchaotic characteristics of 4D MHS make up for the nonlinear deficiency of DRPE. Secondly, a construction method of the deterministic chaotic measurement matrix(DCMM) is proposed. Using DCMM can not only save a lot of transmission bandwidth and storage space, but also ensure good quality of reconstructed images. Thirdly, the confusion method and diffusion method proposed are related to plaintext images, which require both four hyperchaotic sequences of 4D MHS and row and column keys based on plaintext images. The generation process of hyperchaotic sequences is closely related to the hash value of plaintext images. Therefore, this algorithm has high sensitivity to plaintext images. The experimental testing and comparative analysis results show that proposed algorithm has good security and effectiveness.展开更多
A femtosecond optical Kerr gate time-gated ballistic imaging method is demonstrated to image a transparent object in a turbid medium. The shape features of the object are obtained by time-resolved selection of the bal...A femtosecond optical Kerr gate time-gated ballistic imaging method is demonstrated to image a transparent object in a turbid medium. The shape features of the object are obtained by time-resolved selection of the ballistic photons with different optical path lengths, the thickness distribution of the object is mapped, and the maximum is less than 3.6%. This time-resolved ballistic imaging has potential applications in studying properties of the liquid core in the near field of the fuel spray.展开更多
Cells are the basic unit of human organs that are not fully understood.The revolutionary advancements of optical imaging alowed us to observe single cells in whole organs,revealing the complicated composition of cells...Cells are the basic unit of human organs that are not fully understood.The revolutionary advancements of optical imaging alowed us to observe single cells in whole organs,revealing the complicated composition of cells with spatial information.Therefore,in this review,we revisit the principles of optical contrast related to those biomolecules and the optical techniques that transform optical contrast into detectable optical signals.Then,we describe optical imaging to achieve threedimensional spatial discrimination for biological tisutes.Due to the milky appearance of tissues,the spatial information burred deep in the whole organ.Fortunately,strategies developed in the last decade could circumvent this issue and lead us into a new era of investigation of the cells with their original spatial information.展开更多
Cortical spreading depression(CSD)is a wave of neuronal and glial depolarization that propagates across the cortex at a rate of 2–5mm/min accompanied by reversible electroencephalogram(EEG)suppression,a negative shif...Cortical spreading depression(CSD)is a wave of neuronal and glial depolarization that propagates across the cortex at a rate of 2–5mm/min accompanied by reversible electroencephalogram(EEG)suppression,a negative shift of direct current(DC)potential,and change of optical intrinsic signals(OIS).Propagation velocity of CSD is an important parameter used to study this phenomenon.It is commonly determined in an electrophysiological way that measures the time required for a CSD wave to pass along two electrodes.Since the electrophysiology technique fails to reveal the spreading pattern of CSD,velocity calculated in this manner might be inaccurate.In this study,we combined the electrophysiological recording and OIS imaging(OISI)for detecting changes in DC potential and OIS during CSD simultaneously.An optical method based on OISI to determine the CSD velocity,which is measured by generating a series of regions of interest(ROI)perpendicular to the advancing wavefront along propagation direction of CSD at different time points and then dividing by the distance between ROIs over time,is presented.Comparison of the accuracy of the two approaches in determining the CSD velocity is made as well.The average rate of 33 CSDs is 3.52±0.87mm/min by use of the optical method and 4.36±1.65mm/min by use of the electrophysiological method.Because of the information about spreading pattern of CSD provided optically,the velocity determined by OISI is of smaller deviation and higher accuracy.展开更多
基金National Natural Science Foundation of China (Nos.61871353 and 42006164)for their support。
文摘Internal solitary waves(ISWs)change the roughness of the sea surface,thus producing dark and bright bands in optical images.However,reasons for changes in imaging characteristics with the solar zenith angle remain unclear.In this paper,the optical imaging pattern of ISWs in sunglint under different zenith angles of the light source is investigated by collecting optical images of ISWs through physical simulation.The experiment involves setting 10 zenith angles of the light source,which are divided into area a the optical images of ISWs in the three areas show dark-bright mode,single bright band,and bright-dark mode,which are consistent with those observed by optical remote sensing.In addition,this study analyzed the percentage of the dark and bright areas of the bands and the change in the relative gray difference and found changes in both areas under different zenith angles of the light source.The MODIS and ASAR images display a similar brightness-darkness distance of the same ISWs.Therefore,the relationship between the brightness-darkness distance and the characteristic half-width of ISWs is determined in accordance with the eKdV theory and the imaging mechanism of ISWs of the SAR image.Overall,the relationship between them in the experiment is almost consistent with the theoretical result.
文摘In a single-pixel fast imaging setup,the data collected by the single-pixel detector needs to be processed by a computer,but the speed of the latter will affect the image reconstruction time.Here we propose two kinds of setups which are able to transform non-visible into visible light imaging,wherein their computing process is replaced by a camera integration mode.The image captured by the camera has a low contrast,so here we present an algorithm that can realize a high quality image in near-infrared to visible cross-waveband imaging.The scheme is verified both by simulation and in actual experiments.The setups demonstrate the great potential for single-pixel imaging and high-speed cross-waveband imaging for future practical applications.
基金supported,in part,by the University of Wisconsin–Madisonthe National Institutes of Health (P30CA014520 and T32CA009206)the American Cancer Society (125246-RSG-13-099-01-CCE)
文摘Silica nanoparticles have been one of the most promising nanosystems for biomedical applications due to their facile surface chemistry and non-toxic nature. However, it is still challenging to effectively deliver them into tumor sites and noninvasively visualize their in vivo biodistribution with excellent sensitivity and accuracy for effective cancer diagnosis. In this study, we design a yolk/shell-structured silica nanosystem ^(64) Cu-NOTAQD@HMSN-PEG-TRC105, which can be employed for tumor vasculature targeting and dual-modality PET/optical imaging, leading to superior targeting specificity, excellentimaging capability and more reliable diagnostic outcomes.By combining vasculature targeting, pH-sensitive drug delivery, and dual-modality imaging into a single platform,as-designed yolk/shell-structured silica nanosystems may be employed for the future image-guided tumor-targeted drug delivery, to further enable cancer theranostics.
基金Project supported by the National Key R&D Program of China(Grant No.SKLA02020001A05)。
文摘Real-time polarization medium-wave infrared(MIR)optical imaging systems enable the acquisition of infrared and polarization information for a target.At present,real-time polarization MIR devices face the following problems:poor real-time performance,low transmission and high requirements for fabrication and integration.Herein,we aim to improve the performance of real-time polarization imaging systems in the MIR waveband and solve the above-mentioned defects.Therefore,we propose a MIR polarization imaging system to achieve real-time polarization-modulated imaging with high transmission as well as improved performance based on a pixel-wise metasurface micro-polarization array(PMMPA).The PMMPA element comprises several linear polarization(LP)filters with different polarization angles.The optimization results demonstrate that the transmittance of the center field of view for the LP filters is up to 77%at a wavelength of4.0μm and an extinction ratio of 88 d B.In addition,a near-diffraction-limited real-time MIR imaging optical system is designed with a field of view of 5°and an F-number of 2.The simulation results show that an MIR polarization imaging system with excellent real-time performance and high transmission is achieved by using the optimized PMMPA element.Therefore,the method is compatible with the available optical system design technologies and provides a way to realize real-time polarization imaging in MIR wavebands.
文摘A model based on Fourier domain consideration on aperture configuration of optical synthetic aperture imaging system is introduced in this paper. The derivation of the model is directly linked to the restoration error of the original object from the recorded image. The aperture configuration is a function of the maximum frequency of interest, and takes into account the diameter of the aperture. The simulative results of genetic algorithms illustrate the usefulness of this model lot designing a synthetic aperture optical imaging system, and the aperture configuration of a good synthetic aperture optical imaging system should be non-redundant.
文摘Computational optical imaging is an interdisciplinary subject integrating optics, mathematics, and information technology. It introduces information processing into optical imaging and combines it with intelligent computing, subverting the imaging mechanism of traditional optical imaging which only relies on orderly information transmission. To meet the high-precision requirements of traditional optical imaging for optical processing and adjustment, as well as to solve its problems of being sensitive to gravity and temperature in use, we establish an optical imaging system model from the perspective of computational optical imaging and studies how to design and solve the imaging consistency problem of optical system under the influence of gravity, thermal effect, stress, and other external environment to build a high robustness optical system. The results show that the high robustness interval of the optical system exists and can effectively reduce the sensitivity of the optical system to the disturbance of each link, thus realizing the high robustness of optical imaging.
基金Supported by the National Natural Science Foundation of China(NSFC 61501396)the Colleges and Universities under the Science and Technology Research Projects of Hebei Province(QN2015021)
文摘Based on a strong inter-diagonal matrix and Taylor series expansions,an oversample reconstruction method was proposed to calibrate the optical micro-scanning error. The technique can obtain regular 2 ×2 microscanning undersampling images from the real irregular undersampling images,and can then obtain a high spatial oversample resolution image. Simulations and experiments show that the proposed technique can reduce optical micro-scanning error and improve the system's spatial resolution. The algorithm is simple,fast and has low computational complexity. It can also be applied to other electro-optical imaging systems to improve their spatial resolution and has a widespread application prospect.
基金Supported by Veziant J was supported by«année-recherche»grants from the Ministère de la Santéand the Facultéde Médecine de Clermont-FerrandGagnière J was supported by a“Nuovo Soldati Foundation for Cancer Research”grant.
文摘AIM: To investigate the molecular or cellular mechanisms related to the infection of epithelial colonic mucosa by pks-positive Escherichia coli(E. coli) using optical imaging.METHODS: We choose to evaluate the tumor metabolic activity using a fluorodeoxyglucose analogue as 2-deoxyglucosone fluorescent probes and to correlate it with tumoral volume(mm^3). Inflammation measuring myeloperoxidase(MPO) activity and reactive oxygen species production was monitored by a bioluminescent(BLI) inflammation probe and related to histological examination and MPO levels by enzyme-linked immunosorbent assay(ELISA) on tumor specimens. The detection and quantitation of these two signals were validated on a xenograft model of human colon adenocarcinoma epithelial cells(HCT116) in nude mice infected with a pks-positive E. coli. The inflammatory BLI signal was validated intra-digestively in the colitisCEABAC10 DSS models, which mimicked Crohn's disease. RESULTS: Using a 2-deoxyglucosone fluorescent probe, we observed a high and specific HCT116 tumor uptake in correlation with tumoral volume(P = 0.0036). Using the inflammation probe targeting MPO, we detected a rapid systemic elimination and a significant increase of the BLI signal in the pks-positive E. coli-infected HCT116 xenograft group(P < 0.005). ELISA confirmed that MPO levels were significantly higher(1556 ± 313.6 vs 234.6 ± 121.6 ng/m L P = 0.001) in xenografts infected with the pathogenic E. coli strain. Moreover, histological examination of tumor samples confirmed massive infiltration of pks-positive E. coli-infected HCT116 tumors by inflammatory cells compared to the uninfected group. These data showed that infection with the pathogenic E. coli strain enhanced inflammation and ROS production in tumors before tumor growth. Moreover, we demonstrated that the intra-digestive monitoring of inflammation is feasible in a reference colitis murine model(CEABAC10/DSS).CONCLUSION: Using BLI and fluorescence optical imaging, we provided tools to better understand hostpathogen interactions at the early stage of disease, such as inflammatory bowel disease and colorectal cancer.
基金Supported by Wenzhou Municipal Science and Technology Bureau(No.Y20150257)
文摘AIM:To assess peripapillary retinal nerve fiber layer(RNFL)and choroidal thickness obtained with enhanced depth imaging(EDI)mode compared with those obtained without EDI mode using Heidelberg Spectralis optical coherence tomography(OCT).METHODS:Fifty eyes of 25 normal healthy subjects and32 eyes of 20 patients with different eye diseases were included in the study.All subjects underwent 3.4 mm diameter peripapillary circular OCT scan centered on the optic disc using both the conventional and the EDI OCT protocols.The visualization of RNFL and choroidoscleral junction was assessed using an ordinal scoring scale.The paired t-test,intraclass correlation coefficient(ICC),95%limits of agreement(LoA),and Bland and Altman plots were used to test the agreement of measurements.RESULTS:The visibility score of RNFL obtained with and without EDI was of no significant difference(P=0.532),the visualization of choroidoscleral junction was better using EDI protocol than conventional protocol(P〈0.001).Peripapillary RNFL thickness obtained with EDI was slightly thicker than that obtained without EDI(103.25±9.42μm vs 101.87±8.78μm,P=0.010).The ICC of the two protocols was excellent with the value of 0.867 to 0.924,the 95%LoA of global RNFL thickness was between-10.0 to 7.4μm.Peripapillary choroidal thickness obtained with EDI was slightly thinner than that obtained without EDI(147.23±51.04μm vs 150.90±51.84μm,P〈0.001).The ICC was also excellent with the value of 0.960 to 0.987,the 95%LoA of global choroidal thickness was between-12.5 to 19.8μm.CONCLUSION:Peripapillary circular OCT scan with or without EDI mode shows comparable results in the measurement of peripapillary RNFL and choroidal thickness.
基金supported by Canadian Cancer Society Grant#018510 through the National Cancer Institute of Canada.
文摘Recent years have seen the design and implementation of many optical activatable smart probes.These probes are activatable because they change their optical properties and are smart because they can identify specific targets.This broad class of detection agents has allowed previously unperformed visualizations,facilitating the study of diverse biomolecules including enzymes,nucleic acids,ions and reactive oxygen species.Designed to be robust in an in vivo environment,these probes have been used in tissue culture cells and in live small animals.An emerging class of smart probes has been designed to harness the potency of singlet oxygen generating photosensitizers.Combining the discrimination of activatable agents with the toxicity of photosensitizers represents a new and powerful approach to disease treatment.This review highlights some applications of activatable smart probes with a focus on developments of the past decade.
文摘Cutting-edge technologies in optical molecular imaging have ushered in new frontiers in cancer research, clinical translation, and medical practice, as evidenced by recent advances in optical multimodality imaging, Cerenkov luminescence imaging(CLI), and optical imageguided surgeries. New abilities allow in vivo cancer imaging with sensitivity and accuracy that are unprecedented in conventional imaging approaches. The visualization of cellular and molecular behaviors and events within tumors in living subjects is improving our deeper understanding of tumors at a systems level. These advances are being rapidly used to acquire tumor-to-tumor molecular heterogeneity, both dynamically and quantitatively, as well as to achieve more effective therapeutic interventions with the assistance of real-time imaging. In the era of molecular imaging, optical technologies hold great promise to facilitate the development of highly sensitive cancer diagnoses as well as personalized patient treatment—one of the ultimate goals of precision medicine.
基金supported by National Natural Foundation of China(Grant No.61991454)the project of CAS Interdisciplinary Innovation Team。
文摘High resolution imaging is achieved using increasingly larger apertures and successively shorter wavelengths.Optical aperture synthesis is an important high-resolution imaging technology used in astronomy.Conventional long baseline amplitude interferometry is susceptible to uncontrollable phase fluctuations,and the technical difficulty increases rapidly as the wavelength decreases.The intensity interferometry inspired by HBT experiment is essentially insensitive to phase fluctuations,but suffers from a narrow spectral bandwidth which results in a lack of effective photons.In this study,we propose optical synthetic aperture imaging based on spatial intensity interferometry.This not only realizes diffraction-limited optical aperture synthesis in a single shot,but also enables imaging with a wide spectral bandwidth,which greatly improves the optical energy efficiency of intensity interferometry.And this method is insensitive to the optical path difference between the sub-apertures.Simulations and experiments present optical aperture synthesis diffraction-limited imaging through spatial intensity interferometry in a 100 nm spectral width of visible light,whose maximum optical path difference between the sub-apertures reaches 69λ.This technique is expected to provide a solution for optical aperture synthesis over kilometer-long baselines at optical wavelengths.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.11174274,11174279,61205021,11204299,61475152,and 61405194)
文摘Even in the early stage,endocrine metabolism disease may lead to micro aneurysms in retinal capillaries whose diameters are less than 10 μm.However,the fundus cameras used in clinic diagnosis can only obtain images of vessels larger than 20 μm in diameter.The human retina is a thin and multiple layer tissue,and the layer of capillaries less than10 μm in diameter only exists in the inner nuclear layer.The layer thickness of capillaries less than 10 μm in diameter is about 40 μm and the distance range to rod&cone cell surface is tens of micrometers,which varies from person to person.Therefore,determining reasonable capillary layer(CL) position in different human eyes is very difficult.In this paper,we propose a method to determine the position of retinal CL based on the rod&cone cell layer.The public positions of CL are recognized with 15 subjects from 40 to 59 years old,and the imaging planes of CL are calculated by the effective focal length of the human eye.High resolution retinal capillary imaging results obtained from 17 subjects with a liquid crystal adaptive optics system(LCAOS) validate our method.All of the subjects' CLs have public positions from 127 μm to 147 μm from the rod&cone cell layer,which is influenced by the depth of focus.
基金supported by the National Key R&D Program of China(No.2020YFA0710700)the National Natural Science Foundation of China(Nos.51873201 and 82172071)+2 种基金Key Research and Development Program of Anhui Province(No.202104b11020025)the Fundamental Research Funds for the Central Universities(No.YD2060002015)the CAS Youth Interdisciplinary Team(No.JCTD-2021-08).
文摘In liver tumor surgery,the recognition of tumor margin and radical resection of microcancer focis have always been the crucial points to reduce postoperative recurrence of tumor.However,naked-eye inspection and palpation have limited effectiveness in identifying tumor boundaries,and traditional imaging techniques cannot consistently locate tumors in real time.As an intraoperative real-time navigation imaging method,NIRfluorescence imaging has been extensively studied for its simplicity,reliable safety,and superior sensitivity,and is expected to improve the accuracy of liver tumor surgery.In recent years,the research focus of NIRfluorescence has gradually shifted from the-rst near-infrared window(NIR-I,700–900 nm)to the second near-infrared window(NIR-II,1000–1700 nm).Fluorescence imaging in NIR-II reduces the scattering effect of deep tissue,providing a preferable detection depth and spatial resolution while signi-cantly eliminating liver autofluorescence background to clarify tumor margin.Developingfluorophores combined with tumor antibodies will further improve the precision offluorescence-guided surgical navigation.With the development of a bunch offluorophores with phototherapy ability,NIR-II can integrate tumor detection and treatment to explore a new therapeutic strategy for liver cancer.Here,we review the recent progress of NIR-IIfluorescence technology in liver tumor surgery and discuss its challenges and potential development direction.
基金Supported by National Natural Science Foundation of China(No.81300805)。
文摘AIM:To characterize spectral-domain optical coherence tomography(SD-OCT)features of chorioretinal folds in orbital mass imaged using enhanced depth imaging(EDI).METHODS:Prospective observational case-control study was conducted in 20 eyes of 20 patients,the uninvolved eye served as a control.All the patients underwent clinical fundus photography,computed tomography,EDI SDOCT imaging before and after surgery.Two patients with cavernous hemangiomas underwent intratumoral injection of bleomycin A5;the remaining patients underwent tumor excision.Patients were followed 1 to 14mo following surgery(average follow up,5.8mo).RESULTS:Visual acuity prior to surgery ranged from 20/20 to 20/200.Following surgery,5 patients’visual acuity remained unchanged while the remaining 15 patients had a mean letter improvement of 10(range 4 to 26 letters).Photoreceptor inner/outer segment defects were found in 10 of 15 patients prior to surgery.Following surgical excision,photoreceptor inner/outer segment defects fully resolved in 8 of these 10 patients.CONCLUSION:Persistence of photoreceptor inner/outer segment defects caused by compression of the globe by an orbital mass can be associated with reduced visual prognosis.Our findings suggest that photoreceptor inner/outer segment defects on EDI SD-OCT could be an indicator for immediate surgical excision of an orbital mass causing choroidal compression.
基金Supported by Major Scientific and Technological Projects in Zhejiang Province,China(No.2013c03048-3)the Science and Technology Plan Project of Wenzhou Science and Technology Bureau(No.Y20150284)Medical Scientific Research Foundation of Zhejiang Province(No.2016ZDA016)
文摘AIM:To evaluate the peripapillary choroidal thickness(PPCT) in Chinese children,and to analyze the influencing factors.METHODS: PPCT was measured with enhanced depth imaging optical coherence tomography(EDI-OCT) in 70children(53 myopes and 17 non-myopes) aged 7 to 18 y,with spherical equivalent refractive errors between 0.50and-5.87 diopters(D).Peripapillary choroidal imaging was performed using circular scans of a diameter of 3.4 mm around the optic disc.PPCT was measured by EDI-OCT in six sectors: nasal(N),superonasal(SN),superotemporal(ST),temporal(T),inferotemporal(IT)and inferonasal(IN),as well as global RNFL thickness(G).RESULTS: The mean global PPCT was 165.49±33.76 μm.The temporal,inferonasal,inferotemporal PPCT were significantly thinner than the nasal,superonasal,superotemporal segments PPCT were significantly thinner in the myopic group at temporal,superotemporal and inferotemporal segments.The axial length was significantly associated with the average global(β=-0.419,P =0.014),superonasal(β=-2.009,P=0.049) and inferonasal(β=-2.000,P=0.049) PPCT.The other factors(gender,age,SE) were not significantly associated with PPCT.CONCLUSION: PPCT was thinner in the myopic group at temporal,superotemporal and inferotemporal segments.The axial length was found to be negatively correlated to PPCT.We need more further studies about the relationship between PPCT and myopia.
文摘Some existing image encryption schemes use simple low-dimensional chaotic systems, which makes the algorithms insecure and vulnerable to brute force attacks and cracking. Some algorithms have issues such as weak correlation with plaintext images, poor image reconstruction quality, and low efficiency in transmission and storage. To solve these issues,this paper proposes an optical image encryption algorithm based on a new four-dimensional memristive hyperchaotic system(4D MHS) and compressed sensing(CS). Firstly, this paper proposes a new 4D MHS, which has larger key space, richer dynamic behavior, and more complex hyperchaotic characteristics. The introduction of CS can reduce the image size and the transmission burden of hardware devices. The introduction of double random phase encoding(DRPE) enables this algorithm has the ability of parallel data processing and multi-dimensional coding space, and the hyperchaotic characteristics of 4D MHS make up for the nonlinear deficiency of DRPE. Secondly, a construction method of the deterministic chaotic measurement matrix(DCMM) is proposed. Using DCMM can not only save a lot of transmission bandwidth and storage space, but also ensure good quality of reconstructed images. Thirdly, the confusion method and diffusion method proposed are related to plaintext images, which require both four hyperchaotic sequences of 4D MHS and row and column keys based on plaintext images. The generation process of hyperchaotic sequences is closely related to the hash value of plaintext images. Therefore, this algorithm has high sensitivity to plaintext images. The experimental testing and comparative analysis results show that proposed algorithm has good security and effectiveness.
基金Supported by the National Natural Science Foundation of China under Grant Nos 61427816 and 61690221the Collaborative Innovation Center of Suzhou Nano Science and Technology
文摘A femtosecond optical Kerr gate time-gated ballistic imaging method is demonstrated to image a transparent object in a turbid medium. The shape features of the object are obtained by time-resolved selection of the ballistic photons with different optical path lengths, the thickness distribution of the object is mapped, and the maximum is less than 3.6%. This time-resolved ballistic imaging has potential applications in studying properties of the liquid core in the near field of the fuel spray.
基金supported by the National Science and Technology Innovation 2030 Grant No. (2021ZD0200104)National Nature Science Foundation of China (81871082).
文摘Cells are the basic unit of human organs that are not fully understood.The revolutionary advancements of optical imaging alowed us to observe single cells in whole organs,revealing the complicated composition of cells with spatial information.Therefore,in this review,we revisit the principles of optical contrast related to those biomolecules and the optical techniques that transform optical contrast into detectable optical signals.Then,we describe optical imaging to achieve threedimensional spatial discrimination for biological tisutes.Due to the milky appearance of tissues,the spatial information burred deep in the whole organ.Fortunately,strategies developed in the last decade could circumvent this issue and lead us into a new era of investigation of the cells with their original spatial information.
基金This work is supported by the National High Technology Research and Development Program of China(Grant No.2007AA02Z303)the National Natural Science Foundation of China(Grant No.30970964,30801482,30800313)+1 种基金the Program for New Century Excellent Talents in University(Grant No.NCET-08-0213)the Ph.D.Programs Foundation of Ministry of Education of China(Grant No.20070487058,20090142110054).
文摘Cortical spreading depression(CSD)is a wave of neuronal and glial depolarization that propagates across the cortex at a rate of 2–5mm/min accompanied by reversible electroencephalogram(EEG)suppression,a negative shift of direct current(DC)potential,and change of optical intrinsic signals(OIS).Propagation velocity of CSD is an important parameter used to study this phenomenon.It is commonly determined in an electrophysiological way that measures the time required for a CSD wave to pass along two electrodes.Since the electrophysiology technique fails to reveal the spreading pattern of CSD,velocity calculated in this manner might be inaccurate.In this study,we combined the electrophysiological recording and OIS imaging(OISI)for detecting changes in DC potential and OIS during CSD simultaneously.An optical method based on OISI to determine the CSD velocity,which is measured by generating a series of regions of interest(ROI)perpendicular to the advancing wavefront along propagation direction of CSD at different time points and then dividing by the distance between ROIs over time,is presented.Comparison of the accuracy of the two approaches in determining the CSD velocity is made as well.The average rate of 33 CSDs is 3.52±0.87mm/min by use of the optical method and 4.36±1.65mm/min by use of the electrophysiological method.Because of the information about spreading pattern of CSD provided optically,the velocity determined by OISI is of smaller deviation and higher accuracy.