期刊文献+
共找到9篇文章
< 1 >
每页显示 20 50 100
Imaging plate scanners calibration and the attenuation behavior of imaging plate signals
1
作者 薄楠 王乃彦 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第6期38-44,共7页
Based on previously reported work, we propose a new method for calibrating image plate(IP) scanners, offering greater flexibility and convenience, which can be extended to the calibration tasks of various scanner mode... Based on previously reported work, we propose a new method for calibrating image plate(IP) scanners, offering greater flexibility and convenience, which can be extended to the calibration tasks of various scanner models. This method was applied to calibrate the sensitivity of a GE Typhoon FLA 7000 scanner. Additionally, we performed a calibration of the spontaneous signal attenuation behavior for BAS-MS, BAS-SR, and BAS-TR type IPs under the 20±1℃ environmental conditions, and observed significant signal carrier diffusion behavior in BAS-MS IP. The calibration results lay a foundation for further research on the interaction between ultra-short, ultra-intense lasers and matter. 展开更多
关键词 image plate SCANNER ultra-short ultra-intense lasers
下载PDF
Counting of alpha particle tracks on imaging plate based on a convolutional neural network 被引量:1
2
作者 Feng-Di Qin Han-Yu Luo +5 位作者 Zheng-Zhong He Ke-Jun Lu Chuan-Gao Wang Meng-Meng Wu Zhong-Kai Fan Jian Shan 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第3期52-63,共12页
Imaging plates are widely used to detect alpha particles to track information,and the number of alpha particle tracks is affected by the overlapping and fading effects of the track information.In this study,an experim... Imaging plates are widely used to detect alpha particles to track information,and the number of alpha particle tracks is affected by the overlapping and fading effects of the track information.In this study,an experiment and a simulation were used to calibrate the efficiency parameter of an imaging plate,which was used to calculate the grayscale.Images were created by using grayscale,which trained the convolutional neural network to count the alpha tracks.The results demonstrated that the trained convolutional neural network can evaluate the alpha track counts based on the source and background images with a wider linear range,which was unaffected by the overlapping effect.The alpha track counts were unaffected by the fading effect within 60 min,where the calibrated formula for the fading effect was analyzed for 132.7 min.The detection efficiency of the trained convolutional neural network for inhomogeneous ^(241)Am sources(2π emission)was 0.6050±0.0399,whereas the efficiency curve of the photo-stimulated luminescence method was lower than that of the trained convolutional neural network. 展开更多
关键词 imaging plate Convolutional neural network Alpha tracks counting
下载PDF
STRUCTURAL ANALYSIS OF PEKEKK(T/I) USING WAXD, IMAGING PLATES AND SAXS
3
作者 莫志深 《Chinese Journal of Polymer Science》 SCIE CAS CSCD 2004年第4期379-387,共9页
Structures and crystal form transition of the novel aryl ether ketone polymer containing meta-phenylene linkage: PEKEKK(T/I) were investigated by wide angle X-ray diffraction (WAXD), imaging plates (IPs) and small ang... Structures and crystal form transition of the novel aryl ether ketone polymer containing meta-phenylene linkage: PEKEKK(T/I) were investigated by wide angle X-ray diffraction (WAXD), imaging plates (IPs) and small angle X-ray scattering (SAXS). The energy of activation of the decomposition reaction and degree of crystallinity of PEKEKK(T/I) were determined by WAXD and thermo-gravimetric analysis (TGA), respectively. Results obtained from WAXD and IPs show that crystal forms coexist in the PEKEKK(T/I) samples isothermally cold crystallized in the temperature range from 180'C to 240T? and only form occurs in PEKEKK(TTI) samples isothermally cold crystallized at 2701C. The radius of gyration (Rg), thickness of microregions with electron-density fluctuations (E) and distribution of particle sizes were investigated by SAXS. 展开更多
关键词 PEKEKK WAXD imaging plates SAXS Structural analysis
下载PDF
Simulating the Intensifying Effect of Phosphors on Imaging Plate with UV photons
4
作者 张丽平 熊光楠 +1 位作者 郑震 马宇平 《Journal of Rare Earths》 SCIE EI CAS CSCD 2004年第1期143-145,共3页
It is assumed from the energy level that ultraviolet (UV) photons may have intensifying effect on BaFBr∶Eu 2+. In this paper, effect of UV photons (220~290 nm) on the PSL intensity of X-ray irradiated BaFBr∶Eu 2+... It is assumed from the energy level that ultraviolet (UV) photons may have intensifying effect on BaFBr∶Eu 2+. In this paper, effect of UV photons (220~290 nm) on the PSL intensity of X-ray irradiated BaFBr∶Eu 2+ was measured and compared to that on the PSL intensity of 220 nm photons irradiated BaFBr∶Eu 2+. It was found that after the excitation of UV photons the PSL intensity of X-ray irradiated samples decreases least at 250 nm and that of 220 nm photons irradiated samples increases most at 250 nm. When the irradiation sources are X-rays and 220 nm photons the excited electrons are photoelectron and thermal-electrons, respectively, and they have different possibility of being captured by electron traps or combined with luminescent centers. And the peak at 250 nm can be explained with the model of electrons tunneling. It is assumed that the electrons excited by 250 nm have the most possibility of tunneling. 展开更多
关键词 OPTICS photo-stimulated luminescence intensifying effect UV excitation imaging plate rare earths
下载PDF
Experimental research on performances of the imaging plates applied in gamma-ray imaging
5
作者 祁建敏 章法强 +1 位作者 陈进川 谢红卫 《Chinese Physics C》 SCIE CAS CSCD 2014年第1期43-48,共6页
Experimental studies on the basic characteristics of IPs applied in T-ray imaging are carried out by utilizing isotopic y-ray sources. The 1.25 MeV T-ray sensitivity of the BAS-MS and BAS-TR imaging plates and their e... Experimental studies on the basic characteristics of IPs applied in T-ray imaging are carried out by utilizing isotopic y-ray sources. The 1.25 MeV T-ray sensitivity of the BAS-MS and BAS-TR imaging plates and their enhanced sensitivity by covering appropriate Compton conversion foils are measured based on the studies of the image intensity linear calibration, time attenuation laws and the influence of scanning parameter settings. The energy-dependent T-ray sensitivity of the IPs is also obtained by the studies of the measured sensitivity and the Monte Carlo simulated energy deposition in the IPs' sensitive layer. Furthermore, a method of a sandwich detection structure as well as its primary experimental validations are presented in order to increase the gamma-to-neutron ratio in a y/n mixed radiation field. 展开更多
关键词 gamma-ray imaging imaging plate linear calibration time attenuation gamma-ray sensitivity
原文传递
Study on the vehicle license plate tilt correction
6
作者 Li Guihui Li Yuanjin Li Lanyou 《仪器仪表学报》 EI CAS CSCD 北大核心 2006年第z1期715-717,共3页
The shortage of current different approaches of the vehicle license plate(VLP) tilt correction is analyzed in the paper and a new rotary correction method put forward based on the former ways of the VLP tilt correctio... The shortage of current different approaches of the vehicle license plate(VLP) tilt correction is analyzed in the paper and a new rotary correction method put forward based on the former ways of the VLP tilt correction in the horizontal direction and the vertical direction Owing to the VLP tilt taking place in the vertical direction,the array of the image’s pixels of the same column is broken,and even different rows come into being superposition.The VLP tilt taking place in the horizontal direction,by which the array of the image’s pixels of the same row broken,and so much as different columns come into being superposition. 展开更多
关键词 tilt correction vehicle license plate image processing hough transform bilinear interpolation
下载PDF
Optical path design of phase contrast imaging on HL-2A tokamak
7
作者 程启耘 余羿 +11 位作者 龚少博 许敏 兰涛 蒋蔚 袁博达 吴一帆 聂林 柯锐 龙婷 郭栋 叶民友 段旭如 《Plasma Science and Technology》 SCIE EI CAS CSCD 2017年第12期125-130,共6页
A phase contrast imaging(PCI) diagnostic has recently been developed on HL-2 A tokamak. It can diagnose plasma density fluctuations with maximum wave number of 15 cm^(-1) and wave number resolution of 2 cm^(-1).... A phase contrast imaging(PCI) diagnostic has recently been developed on HL-2 A tokamak. It can diagnose plasma density fluctuations with maximum wave number of 15 cm^(-1) and wave number resolution of 2 cm^(-1). The time resolution reaches 2 μs. A 10.6 μm CO_2 laser is expanded to a beam with a diameter of 30 mm and injected into the plasma as an incident beam,injecting into plasma. The emerging scattered and unscattered beams are contrasted by a phase plate. The ideas of optical path design are presented in this paper, together with the parameters of the main optical components. The whole optical path of PCI is not only carefully designed, but also constructed on HL-2 A. First calibration results show the ability of this system to catch plasma turbulence in a wide frequency domain. 展开更多
关键词 phase contrast imaging plasma laser diagnostic phase plate
下载PDF
CR设备使用中应注意的问题
8
作者 连瑞彬 陈国兴 《疾病监测与控制》 2008年第3期164-165,共2页
我院使用的CR机是柯达950型,相机是柯达8900型干式激光相机。均是柯达公司目前推广的最新产品。此产品具有性能优良,图像清晰,处理速度快等优点。与任何X光机均可配合使用。甚至利用小型移动式床旁机也能够获得良好的图像。在我院发... 我院使用的CR机是柯达950型,相机是柯达8900型干式激光相机。均是柯达公司目前推广的最新产品。此产品具有性能优良,图像清晰,处理速度快等优点。与任何X光机均可配合使用。甚至利用小型移动式床旁机也能够获得良好的图像。在我院发挥了巨大作用,并带来了很好的经济效益。 展开更多
关键词 CR(COMPUTED RADIOGRAPHY) 计算机摄影IP(Image.plate) 影像板
下载PDF
Lamb wave topological imaging for blind hole defects in isotropic plates
9
作者 ZHANG Haiyan LIU Fanjie +2 位作者 FAN Guopeng ZHU Wenfa CHAI Xiaodong 《Chinese Journal of Acoustics》 CSCD 2018年第3期358-370,共13页
The research aims at validating the ability of topological imaging to blind holes in isotropic plates using Lamb waves. Due to the defect is not symmetric around the mid- plane of the plate, the effect of Lamb mode co... The research aims at validating the ability of topological imaging to blind holes in isotropic plates using Lamb waves. Due to the defect is not symmetric around the mid- plane of the plate, the effect of Lamb mode conversion will have to be taken into account. The imaging method is based on two computations of ultrasonic fields, one forward and one adjoint, performed for the defect-free reference medium. The excited signal and scattered Lamb waves caused by the blind hole, are used as emitting sources to compute the forward problem and the adjoint problem, respectively. With the help of the finite element simulations, the natural refocusing process of the multimode Lamb waves at the defect location is visually demonstrated by the transient acoustic field snapshots at the different moments to strengthen the physical mechanism of the topological imaging method. The numerical results demonstrate that topological imaging has relatively stronger applicability to the blind hole in contrast to classical Delay And Sum (DAS) method and Time Reversal (TR) method. The topological imaging could handle complex Lamb wave signals containing mode conversions without the imaging quality being affected. The proposed imaging method presents a certain developing potential for detecting and imaging asymmetric defects in plate-like configurations using Lamb waves. 展开更多
关键词 Lamb wave topological imaging for blind hole defects in isotropic plates
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部