期刊文献+
共找到170篇文章
< 1 2 9 >
每页显示 20 50 100
Advances in the application of auxiliary imaging techniques in parathyroid diseases
1
作者 Lei Lu Hong-Qing Shang 《World Journal of Clinical Cases》 SCIE 2024年第17期2946-2950,共5页
Hypoparathyroidism is one of the main complications after total thyroidectomy,severely affecting patients’quality of life.How to effectively protect parathyroid function after surgery and reduce the incidence of hypo... Hypoparathyroidism is one of the main complications after total thyroidectomy,severely affecting patients’quality of life.How to effectively protect parathyroid function after surgery and reduce the incidence of hypoparathyroidism has always been a key research area in thyroid surgery.Therefore,precise localization of parathyroid glands during surgery,effective imaging,and accurate surgical resection have become hot topics of concern for thyroid surgeons.In response to this clinical phenomenon,this study compared several different imaging methods for parathyroid surgery,including nanocarbon,indocyanine green,near-infrared imaging techniques,and technetium-99m methoxyisobutylisonitrile combined with gamma probe imaging technology.The advantages and disadvantages of each method were analyzed,providing scientific recommendations for future parathyroid imaging.In recent years,some related basic and clinical research has also been conducted in thyroid surgery.This article reviewed relevant literature and provided an overview of the practical application progress of various imaging techniques in parathyroid surgery. 展开更多
关键词 imaging technique Parathyroid gland Thyroid surgery HYPOPARATHYROIDISM COMPLICATION
下载PDF
Benign gallbladder diseases:Imaging techniques and tips for differentiating with malignant gallbladder diseases 被引量:18
2
作者 Mi Hye Yu Young Jun Kim +1 位作者 Hee Sun Park Sung Il Jung 《World Journal of Gastroenterology》 SCIE CAS 2020年第22期2967-2986,共20页
Benign gallbladder diseases usually present with intraluminal lesions and localized or diffuse wall thickening.Intraluminal lesions of the gallbladder include gallstones,cholesterol polyps,adenomas,or sludge and polyp... Benign gallbladder diseases usually present with intraluminal lesions and localized or diffuse wall thickening.Intraluminal lesions of the gallbladder include gallstones,cholesterol polyps,adenomas,or sludge and polypoid type of gallbladder cancer must subsequently be excluded.Polyp size,stalk width,and enhancement intensity on contrast-enhanced ultrasound and degree of diffusion restriction may help differentiate cholesterol polyps and adenomas from gallbladder cancer.Localized gallbladder wall thickening is largely due to segmental or focal gallbladder adenomyomatosis,although infiltrative cancer may present similarly.Identification of Rokitansky-Aschoff sinuses is pivotal in diagnosing adenomyomatosis.The layered pattern,degree of enhancement,and integrity of the wall are imaging clues that help discriminate innocuous thickening from gallbladder cancer.High-resolution ultrasound is especially useful for analyzing the layering of gallbladder wall.A diffusely thickened wall is frequently seen in inflammatory processes of the gallbladder.Nevertheless,it is important to check for coexistent cancer in instances of acute cholecystitis.Ultrasound used alone is limited in evaluating complicated cholecystitis and often requires complementary computed tomography.In chronic cholecystitis,preservation of a two-layered wall and weak wall enhancement are diagnostic clues for excluding malignancy.Magnetic resonance imaging in conjunction with diffusion-weighted imaging helps to differentiate xathogranulomatous cholecystitis from gallbladder cancer by identifying the presence of fat and degree of diffusion restriction.Such distinctions require a familiarity with typical imaging features of various gallbladder diseases and an understanding of the roles that assorted imaging modalities play in gallbladder evaluations. 展开更多
关键词 Cholesterol polyp Gallbladder adenoma ADENOMYOMATOSIS CHOLECYSTITIS Xathogranulomatous cholecystitis Gallbladder cancer imaging techniques
下载PDF
Recent advances in imaging techniques of renal masses
3
作者 Ankita Aggarwal Chandan J Das Sanjay Sharma 《World Journal of Radiology》 2022年第6期137-150,共14页
Multiphasic multidetector computed tomography(CT)forms the mainstay for the characterization of renal masses whereas magnetic resonance imaging(MRI)acts as a problem-solving tool in some cases.However,a few of the ren... Multiphasic multidetector computed tomography(CT)forms the mainstay for the characterization of renal masses whereas magnetic resonance imaging(MRI)acts as a problem-solving tool in some cases.However,a few of the renal masses remain indeterminate even after evaluation by conventional imaging methods.To overcome the deficiency in current imaging techniques,advanced imaging methods have been devised and are being tested.This review will cover the role of contrast-enhanced ultrasonography,shear wave elastography,dual-energy CT,perfusion CT,MR perfusion,diffusion-weighted MRI,blood oxygen leveldependent MRI,MR spectroscopy,positron emission tomography(PET)/prostate-specific membrane antigen-PET in the characterization of renal masses. 展开更多
关键词 Advanced imaging techniques Renal mass Contrast-enhanced ultrasonography renal Shear wave elastography
下载PDF
Design of axial flaps with color Doppler flow imaging technique for repairing deep wounds of heels
4
作者 黎洪棉 《外科研究与新技术》 2005年第3期215-215,共1页
To report the methods and effect of axial pattern flap on lower limb in repairing deep wounds of heels by using color Doppler flow imaging (CDFI) technique so as to solve the ever before problems that the vessel can n... To report the methods and effect of axial pattern flap on lower limb in repairing deep wounds of heels by using color Doppler flow imaging (CDFI) technique so as to solve the ever before problems that the vessel can not be displayed in designing axial flap.Methods Suitable axial flaps on lower limbs were selected according to the character of the wounds.There were 25 flaps including 10 cases of the distal-based sural neurovascular flap,nine medial sole flap and six medial leg flap.All the axial pattern flaps were designed on the basis of traditional design ways before operation;then,CDFI appliance with high resolution was used to examine the starting spot,exterior diameter,trail and length of the flap’s major artery.The flaps were redesigned according to the results of CDFI and transferred to cover the wounds.In the meantime,both the results of operation and examination were compared.Results The major artery’s starting spot,exterior diameter,trail and anatomic layers were displayed clearly,in consistency with the results of operation.The flaps survived completely and recovered well,with perfect appearance,color and arthral function.Conclusion CDFI is a simple,macroscopic and atraumatic method for designing the axial pattern flap on lower limb,can provide more scientific and accurate evidence for preoperative determination of flap transplantation and is worthy of clinical application.10 refs,4 figs,2 tabs. 展开更多
关键词 Design of axial flaps with color Doppler flow imaging technique for repairing deep wounds of heels
下载PDF
Imaging of the small bowel in Crohn's disease: A review of old and new techniques 被引量:6
5
作者 Simone Saibeni Emanuele Rondonotti +7 位作者 Andrea Iozzelli Luisa Spina Gian Eugenio Tontini Flaminia Cavallaro Camilla Ciscato Roberto de Franchis Francesco Sardanelli Maurizio Vecchi 《World Journal of Gastroenterology》 SCIE CAS CSCD 2007年第24期3279-3287,共9页
The investigation of small bowel morphology is often mandatory in many patients with Crohn's disease. Traditional radiological techniques (small bowel enteroclysis and small bowel follow-through) have long been th... The investigation of small bowel morphology is often mandatory in many patients with Crohn's disease. Traditional radiological techniques (small bowel enteroclysis and small bowel follow-through) have long been the only suitable methods for this purpose. In recent years, several alternative imaging techniques have been proposed. To review the most recent advances in imaging studies of the small bowel, with particular reference to their possible application in Crohn's disease, we conducted a complete review of the most important studies in which traditional and newer imaging methods were performed and compared in patients with Crohn's disease. Several radiological and endoscopic techniques are now available for the study of the small bowel; each of them is characterized by a distinct profile of favourable and unfavourable features. In some cases, they may also be used as complementary rather than alternative techniques. In everyday practice, the choice of the technique to be used stands upon its availability and a careful evaluation of diagnostic accuracy, clinical usefulness, safety and cost. The recent development ofinnovative imaging techniques has opened a new and exciting area in the exploration of the small bowel in Crohn's disease patients. 展开更多
关键词 Crohn's disease Small bowel imaging techniques ULTRASONOGRAPHY Magnetic resonance Computed tomography Video-capsule endoscopy Double-balloon endoscopy
下载PDF
Plant multiscale networks:charting plant connectivity by multi-level analysis and imaging techniques 被引量:5
6
作者 Xi Zhang Yi Man +21 位作者 Xiaohong Zhuang Jinbo Shen Yi Zhang Yaning Cui Meng Yu Jingjing Xing Guangchao Wang Na Lian Zijian Hu Lingyu Ma Weiwei Shen Shunyao Yang Huimin Xu Jiahui Bian Yanping Jing Xiaojuan Li Ruili Li Tonglin Mao Yuling Jiao Sodmergen Haiyun Ren Jinxing Lin 《Science China(Life Sciences)》 SCIE CAS CSCD 2021年第9期1392-1422,共31页
In multicellular and even single-celled organisms,individual components are interconnected at multiscale levels to produce enormously complex biological networks that help these systems maintain homeostasis for develo... In multicellular and even single-celled organisms,individual components are interconnected at multiscale levels to produce enormously complex biological networks that help these systems maintain homeostasis for development and environmental adaptation.Systems biology studies initially adopted network analysis to explore how relationships between individual components give rise to complex biological processes.Network analysis has been applied to dissect the complex connectivity of mammalian brains across different scales in time and space in The Human Brain Project.In plant science,network analysis has similarly been applied to study the connectivity of plant components at the molecular,subcellular,cellular,organic,and organism levels.Analysis of these multiscale networks contributes to our understanding of how genotype determines phenotype.In this review,we summarized the theoretical framework of plant multiscale networks and introduced studies investigating plant networks by various experimental and computational modalities.We next discussed the currently available analytic methodologies and multi-level imaging techniques used to map multiscale networks in plants.Finally,we highlighted some of the technical challenges and key questions remaining to be addressed in this emerging field. 展开更多
关键词 multiscale network connectivity CYTOSKELETON membrane contact site organelle interaction MULTICELLULARITY CONNECTOME CYTOARCHITECTURE topological analysis multi-level imaging techniques
原文传递
Non-invasive evaluation of liver steatosis with imaging modalities:New techniques and applications 被引量:3
7
作者 Ke-Yu Zeng Wu-Yong-Ga Bao +4 位作者 Yun-Han Wang Min Liao Jie Yang Jia-Yan Huang Qiang Lu 《World Journal of Gastroenterology》 SCIE CAS 2023年第17期2534-2550,共17页
In the world,nonalcoholic fatty liver disease(NAFLD)accounts for majority of diffuse hepatic diseases.Notably,substantial liver fat accumulation can trigger and accelerate hepatic fibrosis,thus contributing to disease... In the world,nonalcoholic fatty liver disease(NAFLD)accounts for majority of diffuse hepatic diseases.Notably,substantial liver fat accumulation can trigger and accelerate hepatic fibrosis,thus contributing to disease progression.Moreover,the presence of NAFLD not only puts adverse influences for liver but is also associated with an increased risk of type 2 diabetes and cardiovascular diseases.Therefore,early detection and quantified measurement of hepatic fat content are of great importance.Liver biopsy is currently the most accurate method for the evaluation of hepatic steatosis.However,liver biopsy has several limitations,namely,its invasiveness,sampling error,high cost and moderate intraobserver and interobserver reproducibility.Recently,various quantitative imaging techniques have been developed for the diagnosis and quantified measurement of hepatic fat content,including ultrasound-or magnetic resonancebased methods.These quantitative imaging techniques can provide objective continuous metrics associated with liver fat content and be recorded for comparison when patients receive check-ups to evaluate changes in liver fat content,which is useful for longitudinal follow-up.In this review,we introduce several imaging techniques and describe their diagnostic performance for the diagnosis and quantified measurement of hepatic fat content. 展开更多
关键词 Non-alcoholic fatty liver disease Hepatic steatosis imaging techniques Quantitative evaluation ULTRASOUND Quantitative ultrasound
下载PDF
Estimation of Sediment Incipient Velocity Using B-Mode Ultrasound Imaging Technique 被引量:2
8
作者 SONG Huan ZOU Xianjian 《Wuhan University Journal of Natural Sciences》 CAS CSCD 2015年第2期180-184,共5页
Sediment incipient velocity (SIV) is a vital parameter for sediment research and river dynamics. This paper describes a novel method of estimating SIV based on the known flow velocity in the movable-bed model experi... Sediment incipient velocity (SIV) is a vital parameter for sediment research and river dynamics. This paper describes a novel method of estimating SIV based on the known flow velocity in the movable-bed model experiment. In this method, we use B-mode ultrasound imaging technique to get video images of moving particles and topography under water. By statistical analysis of video images, the relationship between the average number of imaging particles and flow velocity is obtained. The relationship between the change rate of average number and flow velocity is analyzed in sediment incipient process. These relationships are used to estimate the SIV. Lastly, the changed topography verifies the estimated velocity. The results show there is a sudden change in these relationships which can be used to estimate the SIV with high resolution by using a B-mode ultrasound device. The estimated SIV of plastic sands (particle size is about 0.25 mm) is 3.64 cm · s^-1 and the estimated SIV of natural sands (particle size is about 0.25 mm) is 5.47 cm · s^-1in the same condition. 展开更多
关键词 sediment movement incipient velocity B-mode ultrasound imaging technique particle size
原文传递
Dynamics of chip formation during the cutting process using imaging techniques: A review 被引量:2
9
作者 Guangchao Nie Zhengyan Yang +3 位作者 Dong Zhang Xiaoming Zhang José Outeiro Han Ding 《International Journal of Mechanical System Dynamics》 2022年第1期27-49,共23页
Imaging techniques have been widely implemented to study the dynamics of chip formation.They can offer a direct method and a full field measurement of the cutting process,providing kinematic information of the chip fo... Imaging techniques have been widely implemented to study the dynamics of chip formation.They can offer a direct method and a full field measurement of the cutting process,providing kinematic information of the chip formation process.In this article,the state of the art of the imaging techniques reported in the literature has been summarized and analyzed.The imaging techniques have been applied to study the chip formation mechanism,friction behavior,strain/strain rate,and stress fields.Furthermore,the study of surface integrity has been advanced by deriving the thermo‐mechanical loading,subsurface deformation,and material constitutive model from the imaging technique.Finally,achievements in the area of imaging techniques have been summarized,followed by future directions for their application in the study of surface integrity. 展开更多
关键词 chip formation imaging techniques strain rate STRESS surface integrity
原文传递
E-Cervix imaging displaying cervical elasticity characteristics of healthy adult nulliparous women at different age groups and different menstrual cycle stages
10
作者 XU Yunyan WANG Mingli +1 位作者 LYU Xiaoli LI Xuelei 《中国医学影像技术》 CSCD 北大核心 2024年第8期1208-1211,共4页
Objective To observe the cervical elasticity of healthy adult nulliparous women at different age groups and different stages of menstrual cycle with E-Cervix imaging technology.Methods A total of 218 healthy adult nul... Objective To observe the cervical elasticity of healthy adult nulliparous women at different age groups and different stages of menstrual cycle with E-Cervix imaging technology.Methods A total of 218 healthy adult nulliparous women who underwent transvaginal ultrasound examination for routine physical examination were retrospectively enrolled,including 103 in follicular phase,78 in ovulation phase and 37 in luteal phase.Cervical canal length(CL)and E-Cervix elasticity parameters were compared among different age groups and different stages of menstrual cycle,including elasticity contrast index(ECI),hardness ratio(HR),cervical internal and external orifice strain values(IOS and EOS)and IOS/EOS ratio.Results No significant difference of CL nor cervical elasticity parameters was detected among healthy adult nulliparous women at different age groups(all P>0.05).There were significant differences of ECI,HR and IOS among different menstrual cycle stages(all P<0.05),among which women in follicular phase had higher ECI and IOS but lower HR than those in luteal phase(all P<0.05).Conclusion No significant difference of cervical elasticity existed among healthy adult nulliparous women at different age groups.Meanwhile,cervical elasticity of healthy adult nulliparous women changed during menstrual cycle,in follicular phase had higher ECI and IOS but lower HR than in luteal phase. 展开更多
关键词 cervix uteri MENSTRUATION ULTRASONOGRAPHY elasticity imaging techniques
下载PDF
An FPGA-Based Pulse Pile-up Rejection Technique for Photon Counting Imaging Detectors
11
作者 胡坤 李锋 +2 位作者 陈炼 梁福田 金革 《Chinese Physics Letters》 SCIE CAS CSCD 2015年第3期26-29,共4页
A novel FPGA-based pulse pile-up rejection method for single photon imaging detectors is reported. Tile method is easy to implement in FPGAs for real-time data processing. The rejection principle and entire design are... A novel FPGA-based pulse pile-up rejection method for single photon imaging detectors is reported. Tile method is easy to implement in FPGAs for real-time data processing. The rejection principle and entire design are introduced in detail. The photon counting imaging detector comprises a micro-channel plate (MCP) stack, and a wedge and strip anode (WSA). The resolution mask pattern in front of the MCP can be reconstructed after data processing in the FPGA. For high count rates, the rejection design can effectively reduce the impact of the pulse pile-up on the image. The resolution can reach up to 140μm. The pulse pile-up rejection design can also be applied to high-energy physics and particle detection. 展开更多
关键词 An FPGA-Based Pulse Pile-up Rejection technique for Photon Counting imaging Detectors
下载PDF
A Systematic Review of Computer Vision Techniques for Quality Control in End-of-Line Visual Inspection of Antenna Parts
12
作者 Zia Ullah Lin Qi +2 位作者 E.J.Solteiro Pires Arsénio Reis Ricardo Rodrigues Nunes 《Computers, Materials & Continua》 SCIE EI 2024年第8期2387-2421,共35页
The rapid evolution of wireless communication technologies has underscored the critical role of antennas in ensuring seamless connectivity.Antenna defects,ranging from manufacturing imperfections to environmental wear... The rapid evolution of wireless communication technologies has underscored the critical role of antennas in ensuring seamless connectivity.Antenna defects,ranging from manufacturing imperfections to environmental wear,pose significant challenges to the reliability and performance of communication systems.This review paper navigates the landscape of antenna defect detection,emphasizing the need for a nuanced understanding of various defect types and the associated challenges in visual detection.This review paper serves as a valuable resource for researchers,engineers,and practitioners engaged in the design and maintenance of communication systems.The insights presented here pave the way for enhanced reliability in antenna systems through targeted defect detection measures.In this study,a comprehensive literature analysis on computer vision algorithms that are employed in end-of-line visual inspection of antenna parts is presented.The PRISMA principles will be followed throughout the review,and its goals are to provide a summary of recent research,identify relevant computer vision techniques,and evaluate how effective these techniques are in discovering defects during inspections.It contains articles from scholarly journals as well as papers presented at conferences up until June 2023.This research utilized search phrases that were relevant,and papers were chosen based on whether or not they met certain inclusion and exclusion criteria.In this study,several different computer vision approaches,such as feature extraction and defect classification,are broken down and analyzed.Additionally,their applicability and performance are discussed.The review highlights the significance of utilizing a wide variety of datasets and measurement criteria.The findings of this study add to the existing body of knowledge and point researchers in the direction of promising new areas of investigation,such as real-time inspection systems and multispectral imaging.This review,on its whole,offers a complete study of computer vision approaches for quality control in antenna parts.It does so by providing helpful insights and drawing attention to areas that require additional exploration. 展开更多
关键词 Computer vision end-of-line visual inspection of antenna parts machine learning algorithms image processing techniques deep learning models
下载PDF
Super-resolution Imaging of Telescopic Systems based on Optical-neural Network Joint Optimization
13
作者 You-Hong Sun Tao Zhang +4 位作者 Hao-Dong Shi Qiang Fu Jia-Nan Liu Kai-Kai Wang Chao Wang 《Research in Astronomy and Astrophysics》 SCIE CAS CSCD 2024年第9期167-177,共11页
Optical telescopes are an important tool for acquiring optical information about distant objects,and resolution is an important indicator that measures the ability to observe object details.However,due to the effects ... Optical telescopes are an important tool for acquiring optical information about distant objects,and resolution is an important indicator that measures the ability to observe object details.However,due to the effects of system aberration,atmospheric seeing,and other factors,the observed image of ground-based telescopes is often degraded,resulting in reduced resolution.This paper proposes an optical-neural network joint optimization method to improve the resolution of the observed image by co-optimizing the point-spread function(PSF)of the telescopic system and the image super-resolution(SR)network.To improve the speed of image reconstruction,we designed a generative adversarial net(LCR-GAN)with light parameters,which is much faster than the latest unsupervised networks.To reconstruct the PSF trained by the network in the optical path,a phase mask is introduced.It improves the image reconstruction effect of LCR-GAN by reconstructing the PSF that best matches the network.The results of simulation and verification experiments show that compared with the pure deep learning method,the SR image reconstructed by this method is rich in detail and it is easier to distinguish stars or stripes. 展开更多
关键词 techniques:image processing Telescopes Stars:imaging
下载PDF
EVALUATION OF SMALL ANIMAL IMAGING UNDER DIFFERENT SCAN CONDITIONS
14
作者 贾鹏翔 王浩宇 +4 位作者 闫镔 李磊 陈健 张锋 包尚联 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2010年第1期27-33,共7页
To evaluae small animal imaging with individual different high voltage, filter thickness and tube current, an animal X-ray micro-computed tomography (micro-CT) system based on panel detector is developed and a rat i... To evaluae small animal imaging with individual different high voltage, filter thickness and tube current, an animal X-ray micro-computed tomography (micro-CT) system based on panel detector is developed and a rat is scanned by using the system with individual high voltage, tube current, filter thickness, and exposure time. A model is presented based on the Monte Carlo code PENELOPE for generating the X-ray spectra of X-ray tube used in the micro-CT system. A platform developed based on Matlab allows for calculating beam quality parameters, including the average energy of X-ray beam, the change of transmition rate and the input X-ray fluence. The factors affecting the signal difference to noise ratio (SDNR) of micro-CT are investigated and the relationship between SDNR and scan combinations is analyzed. A series of tools and methods are developed for small animal imaging and imaging performance evaluation in the field of small animal imaging. 展开更多
关键词 imaging techniques micro-computed tomography (CT) imaging performance Monte Carlo simulation
下载PDF
Acoustic radiation force imaging sonoelastography for noninvasive staging of liver fibrosis 被引量:115
15
作者 Carmen Fierbinteanu-Braticevici Dan Andronescu +3 位作者 Radu Usvat Dragos Cretoiu Cristian Baicus Gabriela Marinoschi 《World Journal of Gastroenterology》 SCIE CAS CSCD 2009年第44期5525-5532,共8页
AIM:To investigate the diagnostic accuracy of acoustic radiation force impulse (ARFI) imaging as a noninvasive method for the assessment of liver fibrosis in chronic hepatitis C (CHC) patients.METHODS:We performed a p... AIM:To investigate the diagnostic accuracy of acoustic radiation force impulse (ARFI) imaging as a noninvasive method for the assessment of liver fibrosis in chronic hepatitis C (CHC) patients.METHODS:We performed a prospective blind com-parison of ARFI elastography,APRI index and FibroMax in a consecutive series of patients who underwent liver biopsy for CHC in University Hospital Bucharest. His-topathological staging of liver fibrosis according to the METAVIR scoring system served as the reference. A to-tal of 74 patients underwent ARFI elastography,APRI index,FibroMax and successful liver biopsy. RESULTS:The noninvasive tests had a good correlation with the liver biopsy results. The most powerful test in predicting fibrosis was ARFI elastography. The diagnostic accuracy of ARFI elastography,expressedas area under receiver operating characteristic curve (AUROC) had a validity of 90.2% (95% CI AUROC = 0.831-0.972,P < 0.001) for the diagnosis of significant f ibrosis (F ≥ 2). ARFI sonoelastography predicted even better F3 or F4 fibrosis (AUROC = 0.993,95% CI = 0.979-1).CONCLUSION:ARFI elastography had very good accuracy for the assessment of liver fibrosis and was superior to other noninvasive methods (APRI Index,FibroMax) for staging liver fibrosis. 展开更多
关键词 Elasticity imaging techniques Hepatitis C Liver biopsy Liver fibrosis
下载PDF
Multimodality imaging in apical hypertrophic cardiomyopathy 被引量:12
16
作者 Rosario Parisi Francesca Mirabella +1 位作者 Gioel Gabrio Secco Rossella Fattori 《World Journal of Cardiology》 CAS 2014年第9期916-923,共8页
Apical hypertrophic cardiomyopathy(AHCM) is a relatively rare morphologic variant of HCM in which the hypertrophy of myocardium is localized to the left ventricular apex. Symptoms of AHCM might vary from none to other... Apical hypertrophic cardiomyopathy(AHCM) is a relatively rare morphologic variant of HCM in which the hypertrophy of myocardium is localized to the left ventricular apex. Symptoms of AHCM might vary from none to others mimic coronary artery disease including acute coronary syndrome, thus resulting in inappropriate hospitalization. Transthoracic echocardiography is the firstline imaging technique for the diagnosis of hypertrophic cardiomyopathies. However, when the hypertrophy of the myocardium is localized in the ventricular apex might results in missed diagnosis. Aim of this paper is to review the different imaging techniques used for the diagnosis of AHCM and their role in the detection and comprehension of this uncommon disease. 展开更多
关键词 Apical hypertrophic cardiomyopathy imaging techniques Cardiac magnetic resonance Trans-thoracic echocardiography Multidetector computed tomography
下载PDF
Historical Development in Soil Micromorphological Imaging 被引量:2
17
作者 A.R.Mermut 《Journal of Mountain Science》 SCIE CSCD 2009年第2期107-112,共6页
The book "micropedolog" by Kubieana and a large number of publications has induced many people to practice soil micromorphology. Quantification of the soil fabric and its components was a major challenge. The use of... The book "micropedolog" by Kubieana and a large number of publications has induced many people to practice soil micromorphology. Quantification of the soil fabric and its components was a major challenge. The use of the image analyses in soil science was a breakthrough. Attempts to make soil thin sections go back to the beginning of the 2oth century. Microscopic techniques and recently high resolution electron microscope and use of computer assisted imaging techniques enabled the in vitro study of soils in three dimensional levels. It is now possible to store and process massive amounts of data. Micro- morphological concepts and techniques are applied in paleopedological, ecological, and archaeological studies. The aim of this work was to examine soil micromorphological imaging in historical perspective. 展开更多
关键词 Soil micromorphology quantification imaging techniques HISTORY
下载PDF
Diagnostic and prognostic value of cardiac imaging in amyloidosis 被引量:1
18
作者 Rafael Vidal-Perez Raquel Vázquez-García +5 位作者 Gonzalo Barge-Caballero Alberto Bouzas-Mosquera Rafaela Soler-Fernandez Jose Maria Larrañaga-Moreira Maria Generosa Crespo-Leiro Jose Manuel Vazquez-Rodriguez 《World Journal of Cardiology》 2020年第12期599-614,共16页
Amyloidosis is an infiltrative disease caused by extracellular protein deposition that has accumulated a lot of scientific production in recent years.Different types of amyloidosis can affect the heart.Transthyretin a... Amyloidosis is an infiltrative disease caused by extracellular protein deposition that has accumulated a lot of scientific production in recent years.Different types of amyloidosis can affect the heart.Transthyretin amyloidosis and light chain amyloidosis are the two most common types of cardiac amyloidosis.These entities have a poor prognosis,so accurate diagnostic techniques are imperative for determining an early therapeutic approach.Recent advances in cardiac imaging and diagnostic strategies show that these tools are safe and can avoid the use of invasive diagnostic techniques to histological confirmation,such as endomyocardial biopsy.We performed a review on the diagnostic and prognostic implications of different cardiac imaging techniques in cardiac amyloidosis.We mainly focus on reviewing echocardiography,cardiac magnetic resonance,computed tomography and nuclear imaging techniques and the different safety measurements that can be done with each of them. 展开更多
关键词 Cardiac imaging techniques Transthyretin cardiac amyloidosis Immunoglobulin light-chain amyloidosis ECHOCARDIOGRAPHY Magnetic resonance imaging Nuclear imaging
下载PDF
Construction and imaging of a neurovascular unit model
19
作者 Taiwei Dong Min Li +2 位作者 Feng Gao Peifeng Wei Jian Wang 《Neural Regeneration Research》 SCIE CAS CSCD 2022年第8期1685-1694,共10页
In 2001,the concept of the neurovascular unit was introduced at the Stroke Progress Review Group meeting.The neurovascular unit is an important element of the health and disease status of blood vessels and nerves in t... In 2001,the concept of the neurovascular unit was introduced at the Stroke Progress Review Group meeting.The neurovascular unit is an important element of the health and disease status of blood vessels and nerves in the central nervous system.Since then,the neurovascular unit has attracted increasing interest from research teams,who have contributed greatly to the prevention,treatment,and prognosis of stroke and neurodegenerative diseases.However,additional research is needed to establish an efficient,low-cost,and low-energy in vitro model of the neurovascular unit,as well as enable noninvasive observation of neurovascular units in vivo and in vitro.In this review,we first summarize the composition of neurovascular units,then investigate the efficacy of different types of stem cells and cell culture methods in the construction of neurovascular unit models,and finally assess the progress of imaging methods used to observe neurovascular units in recent years and their positive role in the monitoring and investigation of the mechanisms of a variety of central nervous system diseases. 展开更多
关键词 3D printing blood-brain barrier computational biology ENCEPHALOPATHY imaging techniques microfluidic on-chip methods nerve cell co-culture neurovascular unit REVIEW stem cells
下载PDF
Probing granular inhomogeneity of a particle-emitting source by imaging two-pion Bose–Einstein correlations
20
作者 Li-Ya Li Peng Ru Ying Hu 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2021年第2期81-89,共9页
Using the source imaging technique in two-pion interferometry,we study the image of the hydrodynamic particle-emitting source with the HIJING initial conditions for relativistic heavy-ion collisions on an event-by-eve... Using the source imaging technique in two-pion interferometry,we study the image of the hydrodynamic particle-emitting source with the HIJING initial conditions for relativistic heavy-ion collisions on an event-by-event basis.It is shown that the initial-state fluctuations may give rise to bumpy structures of the medium during hydrodynamical evolution,which affects the two-pion emission space and leads to a visible two-tiered shape in the source function imaged using the two-pion Bose–Einstein correlations.This two-tiered shape can be understood within a similar but more analytic granular source model and is found to be closely related to the introduced quantity n,which characterizes the granular inhomogeneity of the source.By fitting the imaged source function with a granular source parametrization,we extract the granular inhomogeneity of the hydrodynamic source,which is found to be sensitive to both the Gaussian smearing width of the HIJING initial condition and the centrality of the collisions. 展开更多
关键词 Heavy-ion collision Bose-Einstein correlations imaging technique
下载PDF
上一页 1 2 9 下一页 到第
使用帮助 返回顶部