期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
Research on Virtual DC Generator-Based Control Strategy of DCMicrogrid with Photovoltaic and Energy Storage
1
作者 Feng Zhao Chengrui Xiao +1 位作者 Xiaoqiang Chen Ying Wang 《Energy Engineering》 EI 2023年第6期1353-1370,共18页
With the penetration of a large number of photovoltaic power generation units and power electronic converters,the DC microgrid shows low inertia characteristics,which might affect the stable operation of the microgrid... With the penetration of a large number of photovoltaic power generation units and power electronic converters,the DC microgrid shows low inertia characteristics,which might affect the stable operation of the microgrid in extreme cases.In order to enhance the“flexible features”of the interface converter connected to the DC bus,a control strategy of DCmicrogrid with photovoltaic and energy storage based on the virtual DC generator(VDCG)is proposed in this paper.The interface converters of the photovoltaic power generation system and the energy storage system simulates the inertia and damping characteristics of the DC generator to improve the stability of the DC bus voltage.The impedance ratio of DC microgrid was obtained by establishing the small-signal model of photovoltaic power generation system and energy storage system,and the Nyquist curves was applied to analyze the small-signal stability of the system.Finally,the simulation results were verified with MATLAB/Simulink.The results show that the proposed control strategy can slow down the fluctuation of bus voltage under the conditions of photovoltaic power fluctuation and load mutation,thus enhancing the system stability. 展开更多
关键词 DC microgrid with photovoltaic and energy storage virtual DC generator the low inertia characteristics smallsignal model impedance ratio
下载PDF
A simulation-based nonlinear site amplification model for ground-motion prediction equations in Japan 被引量:1
2
作者 Ruibin Hou John Xingquan Zhao 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2021年第4期843-862,共20页
In this manuscript we present a nonlinear site amplification model for ground-motion prediction equations(GMPEs)in Japan,using a site period-based site class and a site impedance ratio as site parameters.We used a lar... In this manuscript we present a nonlinear site amplification model for ground-motion prediction equations(GMPEs)in Japan,using a site period-based site class and a site impedance ratio as site parameters.We used a large number of shear-wave velocity profiles from the Kiban-Kyoshin network(KiK-net)and the Kyoshin network(K-NET)to construct the one-dimensional(1D)numerical models.The strong-motion records from rock-sites in Japan with different earthquake categories and taken from the Pacific Earthquake Engineering Research Center dataset were used in this study.We fit a set of 1D site amplification models using the spectral amplification ratios derived from 1D equivalent linear analyses.Parameters of site impedance ratios for both linear and nonlinear site response were included in the 1D model.The 1D model could be implemented into GMPEs using a new proposed adjustment method.The adjusted site amplification ratios retain the nonlinear characteristics of the 1D model for strong motions and match the linear amplification ratio in GMPE for weak motions.The nonlinearity of the present site model is reasonably similar to that of the historical models,and the present site model could satisfactorily capture the nonlinear site response in empirical data. 展开更多
关键词 nonlinear site amplification model ground-motion prediction equations site class site impedance ratio site response analysis
下载PDF
THE INFLUENCE OF LOW-FREQUENCY VARYING MAGNETIC FIELDON THE PULSATILE FLOW IN A RIGID ROUND TUBE
3
作者 孙东宁 吴望一 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI 1997年第2期121-127,共7页
In this paper, the analytic solution of the dynamical equation of the pulsatile flow in a rigid round tube under the low-frequency varying magnetic field is obtained. The velocity distribution and the flow impedance a... In this paper, the analytic solution of the dynamical equation of the pulsatile flow in a rigid round tube under the low-frequency varying magnetic field is obtained. The velocity distribution and the flow impedance are calculated. The results of e valuable for understanding the influence of low-frequency varying magnetic field on hemodynamics and its clinical application. 展开更多
关键词 low-frequency varying magnetic field pulsatile flow impedance impedance ratio
下载PDF
Hybrid Multi-Infeed Interaction Factor Calculation Method Considering Voltage Regulation Control Characteristics of Voltage Source Converter
4
作者 Shan Liu Chengbin Chi +3 位作者 Fengze Han Yanan Wu Lin Zhu Tuo Wang 《Energy Engineering》 EI 2024年第8期2257-2273,共17页
Voltage source converter based high voltage direct current(VSC-HVDC)can participate in voltage regulation by flexible control to help maintain the voltage stability of the power grid.In order to quantitatively evaluat... Voltage source converter based high voltage direct current(VSC-HVDC)can participate in voltage regulation by flexible control to help maintain the voltage stability of the power grid.In order to quantitatively evaluate its influence on the voltage interaction between VSC-HVDC and line commutated converter based high voltage direct current(LCC-HVDC),this paper proposes a hybrid multi-infeed interaction factor(HMIIF)calculation method considering the voltage regulation control characteristics of VSC-HVDC.Firstly,for a hybrid multi-infeed high voltage direct current system,an additional equivalent operating admittance matrix is constructed to characterize HVDC equipment characteristics under small disturbance.Secondly,based on the characteristic curve between the reactive power and the voltage of a certain VSC-HVDC project,the additional equivalent operating admittance of VSC-HVDC is derived.The additional equivalent operating admittance matrix calculation method is proposed.Thirdly,the equivalent bus impedance matrix is obtained by modifying the alternating current(AC)system admittance matrix with the additional equivalent operating admittance matrix.On this basis,the HMIIF calculation method based on the equivalent bus impedance ratio is proposed.Finally,the effectiveness of the proposed method is verified in a hybrid dual-infeed high voltage direct current system constructed in Power Systems Computer Aided Design(PSCAD),and the influence of voltage regulation control on HMIIF is analyzed. 展开更多
关键词 Hybrid multi-infeed high voltage direct current system hybrid multi-infeed interaction factor control modes equivalent node impedance ratio voltage interaction characteristics
下载PDF
A positive-sequence current based directional relaying approach for CCVT subsidence transient condition 被引量:1
5
作者 Monalisa Biswal Sandeep Biswal 《Protection and Control of Modern Power Systems》 2017年第1期81-91,共11页
In this work,a directional relaying algorithm is proposed for transmission line to prevent relay maloperation during coupling capacitor voltage transformer(CCVT)subsidence transient.The effect of CCVT subsidence trans... In this work,a directional relaying algorithm is proposed for transmission line to prevent relay maloperation during coupling capacitor voltage transformer(CCVT)subsidence transient.The effect of CCVT subsidence transient during single-pole-tripping condition is highlighted in this paper.The proposed method which is based on phase angle difference of post fault and prefault positive sequence current can help the directional relay to take accurate decision during erroneous CCVT secondary response.The available CCVT model in PSCAD is not able to generate significant subsidence transient in the secondary side.So,a new CCVT model is developed in EMTDC/PSCAD domain for transient response analysis and to check the relay operation.Next,the performance of different voltage and current information based directional relaying techniques have been analyzed and compared with the proposed method.The results are evaluated for different system and fault conditions.Results demonstrate the accuracy of the proposed method. 展开更多
关键词 System impedance ratio(SIR) Voltage peak transient Voltage zero transient Ferroresonance suppression circuit(FSC) Fault resistance Protection of transmission line
原文传递
State Key Laboratory of Power Grid Safety and Energy Conservation,China Electric Power Research Institute,Beijing,China
6
作者 Lin Yu Huadong Sun +2 位作者 Shiyun Xu Bing Zhao Jian Zhang 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2022年第3期710-720,共11页
The power system is experiencing a higher penetration of renewable energy generations(REGs).The short circuit ratio(SCR)and the grid impedance ratio(GIR)are two indices to quantify the system strength of the power sys... The power system is experiencing a higher penetration of renewable energy generations(REGs).The short circuit ratio(SCR)and the grid impedance ratio(GIR)are two indices to quantify the system strength of the power system with REGs.In this paper,the critical short circuit ratio(CSCR)is defined as the corresponding SCR when the system voltage is in the critical stable state.Through static voltage stability analysis,the mathematical expression of the CSCR considering the impact of GIR is derived.The maximum value of CSCR is adopted as the critical value to distinguish the weak power system.Based on the static equivalent circuit analysis,it is proved that the CSCR is still effective to evaluate critical system strength considering the interactive impact among REGs.Finally,we find that the GIR can be neglected and the SCR can be used individually to evaluate the system strength when SCR>2 or GIR>5.The correctness and rationality of the CSCR and its critical value are validated on ADPSS. 展开更多
关键词 Critical short circuit ratio critical value grid impedance ratio maximum power transfer theorem static equivalent circuit analysis
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部