期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
The Diagnosis Value and Its Implication of Impulse Oscillometry in Obstructive Sleep Apnea Syndrome Patients 被引量:1
1
作者 刘辉国 倪望 +3 位作者 赵建平 熊盛道 徐永健 张珍祥 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2000年第4期280-282,共3页
The change of measurements of impulse oscillometry (105) in obstructive sleep apnea syn- drome (OSAS) patients and its mechanism were observed. The respiratory impedance was measured by using IOS technique and polyso... The change of measurements of impulse oscillometry (105) in obstructive sleep apnea syn- drome (OSAS) patients and its mechanism were observed. The respiratory impedance was measured by using IOS technique and polysomnography (PSG) was monitored synchronously in 36 OSAS pa- tients,14 patients with chronic obstructive pulmonary disease (COPD) and 12 normal controls. Re- sults showed that R20 in OSAS group was significantly higher than in COPD group and control group (P<0.01). R5-R20 in OSAS group was lower than that in COPD group, but significantly higher than that in control group(P<0. 01). The levels of R20 and R5-R20 were positively correlated with severity degree of the disease. In addition, apnea-hyponea index (AHI) was positively correlated with R5 and R20 with the correlation index (r)being 0. 66 and 0. 86 respectively. The lowest SO2 was negatively correlated with R5 and R5-R20, with r being-0. 66 and- 0. 79 respectively. The mean SO2 was negatively correlated with R5 and R5-R20 with r being-0. 81 and-0. 69 respectively. IOS technique could be used as a valuable tool for assessing the degree of upper airway obstruction in the patients with OSAS, and could help to explore its pathological mechanism. 展开更多
关键词 obstructive sleep apnea syndrome impulse oscillometry airway impedance
下载PDF
Is there a correlation between the changes in airway inflammation and the changes in respiratory mechanics after vaping in patients with asthma?
2
作者 Serafeim-Chrysovalantis Kotoulas Kalliopi Domvri +7 位作者 Alexandros Tsantos Ioanna Papagiouvanni Anastasia Michailidou Dionisios G Spyratos Konstantinos Porpodis Ioanna Grigoriou Despina Papakosta Athanasia Pataka 《World Journal of Methodology》 2024年第2期127-133,共7页
BACKGROUND Electronic cigarettes(ECs)have been promoted as alternatives to traditional cigarettes.To investigate ECs’effects on respiratory system,especially in patients with respiratory diseases.METHODS We randomly ... BACKGROUND Electronic cigarettes(ECs)have been promoted as alternatives to traditional cigarettes.To investigate ECs’effects on respiratory system,especially in patients with respiratory diseases.METHODS We randomly selected 25 smokers with stable moderate asthma and matched them with 25 healthy smokers.All were subjucted to pulmonary function tests(PFTs),impulse oscillometry(IOS),fraction exhaled Nitric Oxide(FeNO),exhaled breathe condensate(EBC)and biomarker measurements before and after vaping one nicotinecontaining EC.RESULTS The increase in FeNO 30 minutes after EC,reflecting airway inflammation,significantly correlated with increase of residual volume(RV),total lung capacity,respiratory impedance at 5 Hz(Z5Hz)and respiratory resistance at 5 and 20 Hz(R5Hz and R20Hz).No significant correlations were found between EBC biomarkers'changes and respiratory mechanics.CONCLUSION This is the first study demonstrating that the changes in airway inflammation caused by EC have direct effects in respiratory mechanics of asthmatic patients. 展开更多
关键词 ASTHMA Electronic cigarette Airway inflammation Lung function impulse oscillometry FENO
下载PDF
Assessment of Respiratory lmpedance During Deep Slow Breathing with lmpulse Oscillometry in Patients with Chronic Obstructive Pulmonary Disease
3
作者 梁永杰 蔡映云 《Chinese Journal of Integrated Traditional and Western Medicine》 2003年第4期266-269,共4页
Objective: To observe the relationship of deep slow respiratory pattern and respiratory impedance(RI) in patients with chronic obstructive pulmonary disease (COPD). Methods: RI under normal respiration and during deep... Objective: To observe the relationship of deep slow respiratory pattern and respiratory impedance(RI) in patients with chronic obstructive pulmonary disease (COPD). Methods: RI under normal respiration and during deep slow respira tion was measured one after the other with impulse oscillometry for 8 patients with COPD and for 9 healthy volunteers as control. Results: When r espiration was changed from normal pattern to the deep slow pattern, the tida l volume increased and respiratory frequency significantly decreased in both gro ups , the total respiratory impedance (Z respir) showed a decreasing trend in COPD group, but with no obvious change in the control group. No chang e in the resonant frequency (fres) was found in both groups, and the respiratory viscous resistance obviously decreased in the COPD group(R5: P =0.0168 ; R20: P =0.0498; R5—R20: P =0.0388),though in the control group it was unchanged. Conclusion: IOS detection could reflect the response he terogeneity of different compartments of respiratory system during tidal breathi ng. During deep slow respiration, the viscous resistance in both central airw ay and peripheral airway was decreased in patients with COPD. RI measurement by impulse oscillometry may be a convenient pathophysiological method for studying the application of breathing exercise in patients with COPD. 展开更多
关键词 chronic obstructive pulmonary disease d eep slow breathing respiratory impedance impulse oscillometry
下载PDF
The diagnostic value of total respiratory impedance by impulse oscillometry in chronic obstructive lung disease 被引量:9
4
作者 王美琴 钮善福 +2 位作者 李燕芹 张志凤 白春学 《Chinese Medical Journal》 SCIE CAS CSCD 1999年第11期23-25,共3页
关键词 chronic obstructive pulmonary diseases ·respiratoryimpedance ·impulse oscillometry
原文传递
The applicable value of respiratory impedance for the stage 0 of chronic obstructive pulmonary disease
5
作者 刘原 谢薇 +2 位作者 魏萍 鱼宝萍 方萍 《Journal of Medical Colleges of PLA(China)》 CAS 2005年第4期245-248,共4页
Objective :To evaluate the applicable value of respiratory impedance for the stage 0 of chronic obstructive pulmonary disease (COPD). Methods:Respiratory impedance was measured by impulse oscillometry (lOS) in 4... Objective :To evaluate the applicable value of respiratory impedance for the stage 0 of chronic obstructive pulmonary disease (COPD). Methods:Respiratory impedance was measured by impulse oscillometry (lOS) in 41 cases at stage 0 of COPD (NHLBI/WHO, 2001 Standard) and their conventional pulmonary function values were compared with 42 healthy subjects. Both groups had no significant deviation in age, stature and avoirdupois, etc. Master-Screen pulmonary function test system (Jaeger Co, Germany) were used to determine IOS parameters including viscous resistance of 5Hz, 20 Hz and 35Hz (R5, R20, R35), reactance of 5Hz, 35 Hz (X3, X35), resonant frequency (Fres) ,total respiratory impedance (Zrs) and routine pulmonary function values including forced expiratory volume in one second to predicted value (FEV1 % ), forced expiratory volume in one second to forced vital capacity ratio( FEV1/ FVC% ), maximal mid expiratory flow (MMEF%),V23% and V50%. Results:Both groups had no significant deviation in FEV1%, FEV1/FVC% and X35(P〉0.05). It was increased significantly in viscous resistance of 5Hz, 20 Hz and 35Hz (R5, R20, R35) in COPD group than that in healthy group (P〈0.01). So were Fres and Zrs (P〈0.01). MMEF%,V25%,V50% and reactance of 5Hz (X5) in COPD group were marked lower than that in healthy group (P〈0.01). The sensitivity of MMEF%, V25%,V50% was higher than others, but its specificity was lower. In parameters of IOS, Fres was the most sensitive index for diagnosis of the small airway function and its specificity was higher than that of MMEF%, V25% ,V50%. Conclusion:In the risk case at the stage 0 of COPD, MMEF%, V25% and V50% could be decreased, but Fres, R5 ,R5-20 could be increased in spite of FEV1% and FEV1/FVC% in normal range. 展开更多
关键词 chronic obstructive pulmonary disease impulse oscillometry respiratory impedance
下载PDF
氣道阻力與常規肺功能測試在慢性阻塞性肺病診斷中的對比研究
6
作者 張曉戰 陳耀球 +7 位作者 程鯤 楊柯 梁振盛 董綺虹 古紀璇 林燕芳 廬淑欣 梁婷芝 《镜湖医学》 2011年第2期14-16,共3页
目的探討氣道阻力在慢性阻塞性肺病(COPD)診斷中的臨床價值。方法對108例COPD患者及22例正常成人應用脈沖振蕩肺功能測定氣道阻力,並與常規肺功能進行比較,分析它們對COPD的診斷價值。結果COPD各組及對照組間常規肺功能指標FEV1、FEV1/F... 目的探討氣道阻力在慢性阻塞性肺病(COPD)診斷中的臨床價值。方法對108例COPD患者及22例正常成人應用脈沖振蕩肺功能測定氣道阻力,並與常規肺功能進行比較,分析它們對COPD的診斷價值。結果COPD各組及對照組間常規肺功能指標FEV1、FEV1/FVC%、FEV1/Pre%、PEF、PEF/Pre%均有統計學意義;COPD組Z5、R5、(R5-R20)、RF、Rp、R5(A/P%)、Z5(A/P%)明顯高於對照組,且隨COPD嚴重程度增加而升高;X5、X20 COPD組顯著低於對照組,且隨COPD嚴重程度增加而降低;Z5、R5、(R5-R20)、RF、Rp、R5(A/P%)、Z5(A/P)%分別與FEV1、FEV1/FVC%、FEV1/Pre%、PEF、PEF/Pre%呈顯著負相關,與X5、X20呈顯著正相關,其中RF的相關性最爲密切;IOS各指標ROC曲線分析顯示,R5(A1/P%)正常值取值爲136時,約登指數最高;Z5(A1/P%)正常值取值爲100時,約登指數最高;RF正常值取值爲18.23時,X5正常值取值爲-0.24時,X20正常值取值爲0.005時,各約登指數最高。結論脈沖振蕩肺功能對COPD具有診斷價值,其指標與病情嚴重程度相關;與常規肺功能指標有顯著相關性。但其預計值方程式及正常值範圍值得進一步研究。 展开更多
关键词 常規肺功能 脈沖振蕩肺功能(impulse oscillometry IOS) 慢性阻塞性肺病(COPD)
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部