AIM: To evaluate cut-off values and performance of acoustic radiation force impulse imaging (ARFI) using transient elastography [FibroScan■ (FS)] as a reference. METHODS: Six hundred and six patients were enrolled in...AIM: To evaluate cut-off values and performance of acoustic radiation force impulse imaging (ARFI) using transient elastography [FibroScan■ (FS)] as a reference. METHODS: Six hundred and six patients were enrolled in this study.All patients underwent liver stiffness measurement with FS (FS-LS) and ARFI (with shear wave velocity quantification; ARFI-SWV) and the performance of ARFI in comparison to FS was determined. Sixtyeight patients underwent liver biopsy. RESULTS: Significantly higher success rates for the determination of liver stiffness were found using ARFI as compared to FS [604/606 (99.7%) vs 482/606 (79.5%); P < 0.001]. ARFI-SWV correlated significantly with FS-LS (r = 0.920, P < 0.001). ARFI-SWV increased significantly with the stage of fibrosis (1.09 ± 0.13 m/s for patients with no significant fibrosis (FS-LS < 7.6 kPa); 1.46 ± 0.27 m/s for patients with significant liver fibrosis (7.6 < FS-LS ≤ 13.0 kPa); and 2.55 ± 0.77 m/s for patients with liver cirrhosis (FS-LS > 13.0 kPa)). ARFI-SWV cut-off values were identified for no significant fibrosis (1.29 m/s; sensitivity 91.4% and specificity 92.6%) and for liver cirrhosis (1.60 m/s; sensitivity 92.3% and specificity 96.5%). The optimal cut-off value for predicting liver fibrosis (F ≥ 2) was 1.32 m/s (sensitivity 87.0% and specificity 80.0%) and for liver cirrhosis (F4) 1.62 m/s (sensitivity 100% and specificity 85.7%), for patients who underwent liver biopsy. An excellent inter-and intraobserver reproducibility was observed for ARFI-SWV determinations. CONCLUSION: An ARFI-SWV cut-off value of 1.29 m/s seems to be optimal for patients with no significant liver fibrosis and 1.60 m/s for patients with liver cirrhosis.展开更多
BACKGROUND: Acoustic radiation force impulse (ARFI) imaging is a new elastography method for the evaluation of tissue stiffness. This study aims to evaluate the performance of ARFI in noninvasive assessment of the tis...BACKGROUND: Acoustic radiation force impulse (ARFI) imaging is a new elastography method for the evaluation of tissue stiffness. This study aims to evaluate the performance of ARFI in noninvasive assessment of the tissue stiffness of focal liver lesion (FLL) and to explore its potential value in the differential diagnosis of FLL. METHODS: ARFI was performed in 140 patients with 154 FLLs, which included 28 hemangiomas (ANGIs), 14 focal nodular hyperplasias (FNHs), 61 hepatocellular carcinomas (HCCs), 39 metastases and 12 cholangiocellular carcinomas (CCCs). Virtual touch tissue quantification (VTTQ) values were obtained, analyzed and compared. The area under the receiver operating characteristic curve (AUROC) and optimal cut-off values were obtained using a receiver operating characteristic (ROC) curve analysis to assess diagnostic performance. All cases were definitively diagnosed using histopathology, CT, MRI or contrast-enhanced ultrasound. RESULTS: The VTTQ median values of ANGI, FNH, HCC metastasis and CCC were 1.30, 1.80, 2.52, 3.08 and 3.89 m/s respectively. A significant increase in the VTTQ values of different lesions was observed: ANGI【FNH【HCC【metastasis 【CCC (P【0.001). The AUROC (95% CI) of VTTQ values was 0.94 (0.90-0.98) for ANGI, 0.91 (0.87-0.96) for malignant lesions and 0.87 (0.79-0.94) for CCC. The sensitivity and specificity for ANGI (86.5%, 89.3%, respectively), malignancy (81.3% 92.9%, respectively), and CCC (91.7%, 72.5%, respectively) were associated with VTTQ cut-off values of 1.76, 2.22 and 3.00 m/s respectively.CONCLUSIONS: ARFI can accurately and objectively assess the elasticity of lesions by obtaining the shear wave elastic value of FLL with VTTQ. Therefore, ARFI is a novel, simple, noninvasive and useful diagnostic method for the characterization of FLL.展开更多
Objective: The aim of our study was to make the qualitative and quantitative analysis to breast lesions using acoustic radiation force impulses (ARFI), and assess the diagnostic value of ARFI for differentiation be...Objective: The aim of our study was to make the qualitative and quantitative analysis to breast lesions using acoustic radiation force impulses (ARFI), and assess the diagnostic value of ARFI for differentiation between benign and malignant solid breast masses, meanwhile evaluate the influences of ARFI with breast imaging reporting and data system (BI-RADS) of suspicious masses. Methods: Seventy-five women with 86 breast lesions underwent conventional breast ultra- sound examination. Then B-mode BI-RADS features and assessments were recorded and standard breast US supplemented by ARFI elastographic examination were repeated. The data were recorded and analyzed as following: area ratio of breast lesion, the shear-wave velocity, the ratio of the shear-wave velocity between lesions and surrounding normal tissues, and according to the elastographic data reconsidered the BI-RADS category, all the results have been correlated with pathological results and make statistical evaluations of ARFI for differentiation between benign and malignant solid breast masses. Meantime our study has correlated the adjusted BI-RADS category of suspicious breast lesions with the pathological results and made assessment. Results: Thirty-eight patients were malignant breast carcinoma (31 invasive ductal carcinoma, 5 intraductal carcinoma in situ, 2 medullary carcinoma, 2 invasive Iobular carcinoma), 48 patients were benign breast lesions (23 fibroadenoma, 12 benign nodular hyperplasia, 5 phyllodes tumor, 6 adenosis, 2 intraductal papilloma). Underwent conventional breast ultrasound exam, 42 cases were BI-RADS category 3, 23 cases were BI-RADS category 4. When adding elastographic data, 46 cases were BI-RADS category 3 and 20 cases were BI-RADS category 4. Compared with pathological results showed for both the specificity of BIRADS features and the area under ROC curve has risen. Virtual touch tissue imaging (VTI) and virtual touch tissue quantification (VTQ) data showed the area ratio (AR) between elastographic lesions area and B-mode lesions area, SWV (maximal shear-wave velocity of lesions), R-SWV (shear-wave velocity ratio between lesions and surrounding normal tissues) in benign breast lesions were lower than those in malignant lesions which has statistical significance and the cut-off point were 1.1,4.65 m/s, 5.18 respectively. Conclusion: The ARFI elastography can provide the reliable qualitative and quantitative analysis about hardness of breast lesions, supply the new BI-RADS category features to suspicious breast masses and serve as an effective diagnostic tool for differentiation between benign and malignant solid masses.展开更多
Chronic hepatitis B(CHB)infection is a major public health problem associated with significant morbidity and mortality worldwide.Twenty-three percent of patients with CHB progress naturally to liver cirrhosis,which wa...Chronic hepatitis B(CHB)infection is a major public health problem associated with significant morbidity and mortality worldwide.Twenty-three percent of patients with CHB progress naturally to liver cirrhosis,which was earlier thought to be irreversible.However,it is now known that cirrhosis can in fact be reversed by treatment with oral anti-nucleotide drugs.Thus,early and accurate diagnosis of cirrhosis is important to allow an appropriate treatment strategy to be chosen and to predict the prognosis of patients with CHB.Liver biopsy is the reference standard for assessment of liver fibrosis.However,the method is invasive,and is associated with pain and complications that can be fatal.In addition,intra-and inter-observer variability compromises the accuracy of liver biopsy data.Only small tissue samples are obtained and fibrosis is heterogeneous in such samples.This confounds the two types of observer variability mentioned above.Such limitations have encouraged development of non-invasive methods for assessment of fibrosis.These include measurements of serum biomarkers of fibrosis;and assessment of liver stiffness via transient elastography,acoustic radiation force impulse imaging,real-time elastography,or magnetic resonance elastography.Although significant advances have been made,most work to date has addressed the diagnostic utility of these techniques in the context of cirrhosis caused by chronic hepatitis C infection.In the present review,we examine the advantages afforded by use of non-invasive methods to diagnose cirrhosis in patients with CHB infections and the utility of such methods in clinical practice.展开更多
Progressive hepatic fibrosis can lead to cirrhosis,so its early detection is fundamental.Staging fibrosis is also critical for prognosis and management.The gold standard for these aims is liver biopsy,but it has sever...Progressive hepatic fibrosis can lead to cirrhosis,so its early detection is fundamental.Staging fibrosis is also critical for prognosis and management.The gold standard for these aims is liver biopsy,but it has several drawbacks,as it is invasive,expensive,has poor acceptance,is prone to inter observer variability and sampling errors,has poor repeatability,and has a risk of complications and mortality.Therefore,non-invasive imaging tests have been developed.This review mainly focuses on the role of transient elastography,acoustic radiation force impulse imaging,and magnetic resonance-based methods for the noninvasive diagnosis of cirrhosis.展开更多
文摘AIM: To evaluate cut-off values and performance of acoustic radiation force impulse imaging (ARFI) using transient elastography [FibroScan■ (FS)] as a reference. METHODS: Six hundred and six patients were enrolled in this study.All patients underwent liver stiffness measurement with FS (FS-LS) and ARFI (with shear wave velocity quantification; ARFI-SWV) and the performance of ARFI in comparison to FS was determined. Sixtyeight patients underwent liver biopsy. RESULTS: Significantly higher success rates for the determination of liver stiffness were found using ARFI as compared to FS [604/606 (99.7%) vs 482/606 (79.5%); P < 0.001]. ARFI-SWV correlated significantly with FS-LS (r = 0.920, P < 0.001). ARFI-SWV increased significantly with the stage of fibrosis (1.09 ± 0.13 m/s for patients with no significant fibrosis (FS-LS < 7.6 kPa); 1.46 ± 0.27 m/s for patients with significant liver fibrosis (7.6 < FS-LS ≤ 13.0 kPa); and 2.55 ± 0.77 m/s for patients with liver cirrhosis (FS-LS > 13.0 kPa)). ARFI-SWV cut-off values were identified for no significant fibrosis (1.29 m/s; sensitivity 91.4% and specificity 92.6%) and for liver cirrhosis (1.60 m/s; sensitivity 92.3% and specificity 96.5%). The optimal cut-off value for predicting liver fibrosis (F ≥ 2) was 1.32 m/s (sensitivity 87.0% and specificity 80.0%) and for liver cirrhosis (F4) 1.62 m/s (sensitivity 100% and specificity 85.7%), for patients who underwent liver biopsy. An excellent inter-and intraobserver reproducibility was observed for ARFI-SWV determinations. CONCLUSION: An ARFI-SWV cut-off value of 1.29 m/s seems to be optimal for patients with no significant liver fibrosis and 1.60 m/s for patients with liver cirrhosis.
文摘BACKGROUND: Acoustic radiation force impulse (ARFI) imaging is a new elastography method for the evaluation of tissue stiffness. This study aims to evaluate the performance of ARFI in noninvasive assessment of the tissue stiffness of focal liver lesion (FLL) and to explore its potential value in the differential diagnosis of FLL. METHODS: ARFI was performed in 140 patients with 154 FLLs, which included 28 hemangiomas (ANGIs), 14 focal nodular hyperplasias (FNHs), 61 hepatocellular carcinomas (HCCs), 39 metastases and 12 cholangiocellular carcinomas (CCCs). Virtual touch tissue quantification (VTTQ) values were obtained, analyzed and compared. The area under the receiver operating characteristic curve (AUROC) and optimal cut-off values were obtained using a receiver operating characteristic (ROC) curve analysis to assess diagnostic performance. All cases were definitively diagnosed using histopathology, CT, MRI or contrast-enhanced ultrasound. RESULTS: The VTTQ median values of ANGI, FNH, HCC metastasis and CCC were 1.30, 1.80, 2.52, 3.08 and 3.89 m/s respectively. A significant increase in the VTTQ values of different lesions was observed: ANGI【FNH【HCC【metastasis 【CCC (P【0.001). The AUROC (95% CI) of VTTQ values was 0.94 (0.90-0.98) for ANGI, 0.91 (0.87-0.96) for malignant lesions and 0.87 (0.79-0.94) for CCC. The sensitivity and specificity for ANGI (86.5%, 89.3%, respectively), malignancy (81.3% 92.9%, respectively), and CCC (91.7%, 72.5%, respectively) were associated with VTTQ cut-off values of 1.76, 2.22 and 3.00 m/s respectively.CONCLUSIONS: ARFI can accurately and objectively assess the elasticity of lesions by obtaining the shear wave elastic value of FLL with VTTQ. Therefore, ARFI is a novel, simple, noninvasive and useful diagnostic method for the characterization of FLL.
文摘Objective: The aim of our study was to make the qualitative and quantitative analysis to breast lesions using acoustic radiation force impulses (ARFI), and assess the diagnostic value of ARFI for differentiation between benign and malignant solid breast masses, meanwhile evaluate the influences of ARFI with breast imaging reporting and data system (BI-RADS) of suspicious masses. Methods: Seventy-five women with 86 breast lesions underwent conventional breast ultra- sound examination. Then B-mode BI-RADS features and assessments were recorded and standard breast US supplemented by ARFI elastographic examination were repeated. The data were recorded and analyzed as following: area ratio of breast lesion, the shear-wave velocity, the ratio of the shear-wave velocity between lesions and surrounding normal tissues, and according to the elastographic data reconsidered the BI-RADS category, all the results have been correlated with pathological results and make statistical evaluations of ARFI for differentiation between benign and malignant solid breast masses. Meantime our study has correlated the adjusted BI-RADS category of suspicious breast lesions with the pathological results and made assessment. Results: Thirty-eight patients were malignant breast carcinoma (31 invasive ductal carcinoma, 5 intraductal carcinoma in situ, 2 medullary carcinoma, 2 invasive Iobular carcinoma), 48 patients were benign breast lesions (23 fibroadenoma, 12 benign nodular hyperplasia, 5 phyllodes tumor, 6 adenosis, 2 intraductal papilloma). Underwent conventional breast ultrasound exam, 42 cases were BI-RADS category 3, 23 cases were BI-RADS category 4. When adding elastographic data, 46 cases were BI-RADS category 3 and 20 cases were BI-RADS category 4. Compared with pathological results showed for both the specificity of BIRADS features and the area under ROC curve has risen. Virtual touch tissue imaging (VTI) and virtual touch tissue quantification (VTQ) data showed the area ratio (AR) between elastographic lesions area and B-mode lesions area, SWV (maximal shear-wave velocity of lesions), R-SWV (shear-wave velocity ratio between lesions and surrounding normal tissues) in benign breast lesions were lower than those in malignant lesions which has statistical significance and the cut-off point were 1.1,4.65 m/s, 5.18 respectively. Conclusion: The ARFI elastography can provide the reliable qualitative and quantitative analysis about hardness of breast lesions, supply the new BI-RADS category features to suspicious breast masses and serve as an effective diagnostic tool for differentiation between benign and malignant solid masses.
基金Supported by A grant of the South Korea Healthcare technology R and D projectMinistry of Health and Welfare+1 种基金South KoreaNo.HI10C2020
文摘Chronic hepatitis B(CHB)infection is a major public health problem associated with significant morbidity and mortality worldwide.Twenty-three percent of patients with CHB progress naturally to liver cirrhosis,which was earlier thought to be irreversible.However,it is now known that cirrhosis can in fact be reversed by treatment with oral anti-nucleotide drugs.Thus,early and accurate diagnosis of cirrhosis is important to allow an appropriate treatment strategy to be chosen and to predict the prognosis of patients with CHB.Liver biopsy is the reference standard for assessment of liver fibrosis.However,the method is invasive,and is associated with pain and complications that can be fatal.In addition,intra-and inter-observer variability compromises the accuracy of liver biopsy data.Only small tissue samples are obtained and fibrosis is heterogeneous in such samples.This confounds the two types of observer variability mentioned above.Such limitations have encouraged development of non-invasive methods for assessment of fibrosis.These include measurements of serum biomarkers of fibrosis;and assessment of liver stiffness via transient elastography,acoustic radiation force impulse imaging,real-time elastography,or magnetic resonance elastography.Although significant advances have been made,most work to date has addressed the diagnostic utility of these techniques in the context of cirrhosis caused by chronic hepatitis C infection.In the present review,we examine the advantages afforded by use of non-invasive methods to diagnose cirrhosis in patients with CHB infections and the utility of such methods in clinical practice.
文摘Progressive hepatic fibrosis can lead to cirrhosis,so its early detection is fundamental.Staging fibrosis is also critical for prognosis and management.The gold standard for these aims is liver biopsy,but it has several drawbacks,as it is invasive,expensive,has poor acceptance,is prone to inter observer variability and sampling errors,has poor repeatability,and has a risk of complications and mortality.Therefore,non-invasive imaging tests have been developed.This review mainly focuses on the role of transient elastography,acoustic radiation force impulse imaging,and magnetic resonance-based methods for the noninvasive diagnosis of cirrhosis.