Influence of pipe parameters and heat input on thermal cycle of in-service welding onto active gas pipeline
1
作者 王勇 陈玉华 韩彬 《China Welding》 EI CAS 2007年第4期32-36,共5页
The software of SYSWELD was used to build model and simulate thermal cycle of in-service welding onto active gas pipeline. Influence of pipe diameter, wall thickness and heat input on thermal cycle was studied. The re... The software of SYSWELD was used to build model and simulate thermal cycle of in-service welding onto active gas pipeline. Influence of pipe diameter, wall thickness and heat input on thermal cycle was studied. The results show that t8/5 , t8/3 and peak temperature of inner surface decrease when wall thickness increases from 5 mm to 12 mm. But t8/1 will increases with the increase of wall thickness and will decrease after the wall thickness is larger than 7 mm. Pipe diameter has little influence on thermal cycle and that influence can be ignored when pipe diameter is greater than 273 mm. t8/5 , t8/3 , t8/1 and peak temperature of inner surface will increase with the increase of heat input. 展开更多
关键词 active gas pipeline in-service welding weld thermal cycle numerical simulation