The natural gas hydrate has been regarded as an important future green energy.Significant progress on the hydrate exploitation has been made,but some challenges are still remaining.In order to enhance the hydrate expl...The natural gas hydrate has been regarded as an important future green energy.Significant progress on the hydrate exploitation has been made,but some challenges are still remaining.In order to enhance the hydrate exploitation efficiency,a significant understanding of the effective thermal conductivity(ETC)of the hydrate-bearing sediment has become essential,since it directly controls the heat and mass transfer behaviors,and thereby determines the stability of hydrate reservoir and production rate.In this study,the effective thermal conductivities of various hydrate-bearing sediments were in-situ measured and studied.The impacts of temperature,particle size and type of sediment were investigated.The effective thermal conductivities of the quartz sand sediments before and after hydrate formation were in-situ measured.The results show the weak negative correlation of effective thermal conductivity of the quartz sand sediment on the temperature before and after the hydrate formation.The effective thermal conductivity of the hydrate-bearing sediment decreases with the increase of particle size of the sediment.The dominant effect of the type of porous medium on the characteristics of the effective thermal conductivity of hydrate-bearing sediment was highlighted.The results indicate that both the effective thermal conductivities of hydrate-bearing quartz sand sediment and hydrate-bearing silicon carbide sediment are weakly negatively correlated with temperature,but the effective thermal conductivity of hydrate-bearing clay sediment is weakly positively dependent on the temperature.In addition,the values of the effective thermal conductivities of various hydrate-bearing sediments are in the order of hydrate-bearing silicon carbide sediment>hydrate-bearing quartz sand sediment>hydrate-bearing clay sediment.These findings could suggest that the intrinsic thermal conductivity of porous medium could control the characteristics of effective thermal conductivity of hydrate-bearing sediment.展开更多
In order to explore the thermal conductivity of the natural poly-mineral rock,numerical tests of rock models with randomly-distributed components were conducted and compared with each other.Elaborately designed Monte ...In order to explore the thermal conductivity of the natural poly-mineral rock,numerical tests of rock models with randomly-distributed components were conducted and compared with each other.Elaborately designed Monte Carlo method was adopted to ingratiate the requirement of the random characteristics of grain size and the grains'spatial distribution.This requirement was fulfilled by clustering the randomly generated unstructured tetrahedral elements in full three dimensions.Natural rocks are consisted of randomly distributed crystal particles or intergranular minerals.Our primary results verify that the thermal conductivity of the rock is strongly sensitive to the ingredients' volume fraction and their spatial distribution.Furthermore,we proved that,in order to reduce the measurement error to a reasonable range,the numerical specimen must be large enough or include sufficient number of mineral particles.Our numerical test results are in accordance with a variety of empirical formulas which are currently employed in petrology.展开更多
The authors presented a new measuring method of the soil thermal conductivity,the probe method,which is designed and made based on the theory of line heat source. This method is used to measure thermal conductivity of...The authors presented a new measuring method of the soil thermal conductivity,the probe method,which is designed and made based on the theory of line heat source. This method is used to measure thermal conductivity of coarse sand,fine sand and silty clay in different water contents. The results that measured by the probe method are well consistent with those of QTM-D_2. The soil thermal conductivity increases in different levels with the increase of the water content. Compared the soil thermal conductivity measured by the probe method in laboratory with in-situ experiment,it shows that the measuring gap gradually increases with the increase of the depth. The reason is that the in-situ measuring thermal conductivity can reflect the actual situation of the soil mass.展开更多
This paper presents an experimental study on the evaluation of thermal response of a spiral coil type GHE (ground heat exchanger). This GHE was installed on partially saturated landfill ground that was composed of s...This paper presents an experimental study on the evaluation of thermal response of a spiral coil type GHE (ground heat exchanger). This GHE was installed on partially saturated landfill ground that was composed of silt and clay in the runway area of Incheon International airport. TRT (thermal response test) was conducted for more than 65 hours under continuous operation conditions. Ground thermal conductivity was derived based on line source theory, which has usually been found to be appropriate for line type GHEs such as U, W and 2U types. A reasonable method to derive ground thermal conductivity using the infinite line source theory for a spiral coil type GHE was introduced. Ground thermal conductivity from the TRT using spiral coil type GHE was compared with those from the analytical equivalent model of ground thermal conductivity.展开更多
Biodegradable poly (D,L-lactide) (PLA)/carboxyl-functionalized multi-walled carbon nanotubes (c-MWCNTs) composites were achieved via in-situ polymerization. These as-prepared composite materials were characteriz...Biodegradable poly (D,L-lactide) (PLA)/carboxyl-functionalized multi-walled carbon nanotubes (c-MWCNTs) composites were achieved via in-situ polymerization. These as-prepared composite materials were characterized with FT-IR, XRD, TG, DSC, SEM, and high insulation resistance meter. The results demonstrate that the multi-walled carbon nanotube was carboxyl functionalized, which improved the collection between c-MWCNTs and PLA, and further realized the graft copolymerization of c-MWCNTs and PLA. There is a higher glass transition temperature and a lower pyrolysis temperature of PLA/c-MWCNTs composites than pure PLA. The c-MWCNTs gave a better dispersion than unmodified MWCNTs in the PLA matrix, and an even coating of PLA on the surface of c-MWCNTs was obtained, which increased the interfacial interaction. High insulation resistance analysis showed that the addition of c-MWCNTs increased the electric conductivity, and c-MWCNTs performed against the large dielectric coefficient and electrostatic state of PLA. These results demonstrated that c-MWCNTs modified PLA composites were beneficial for potential application in the development of heat-resisting and conductivity plastic engineering.展开更多
An improved test rig providing both the heat and cold source was used to perform thermal response test (TRT), and the line source model was used for data analysis. The principle of determining the temperature differ...An improved test rig providing both the heat and cold source was used to perform thermal response test (TRT), and the line source model was used for data analysis. The principle of determining the temperature difference between the inlet and outlet of test well can keep the heating or cooling rate constant, along with a reduced size of test rig. Among the influencial factors of the line source model, the temperature difference was determined as the most important, which agreed with the test results. When the gravel was taken as the backfill material, the soil thermal conductivities of heating and cooling at the test place were 1.883 W/(m·K) and 1.754 W/(m·K), respectively, and the deviation of TRT between heating and cooling soil was 6.8%. In the case of fine sand, the thermal conductivities of heating and cooling were 1.541 W/(m·K) and 1.486 W/(m·K), respectively, and the corresponding deviation was 6%. It was also concluded that different velocities of water had less influence on TRT than the temperature difference.展开更多
The performance of a BTES (borehole thermal energy storage) system is primarily governed by ground heat flux, soil thermal properties and groundwater conditions. However, the design of the heat exchanger used within...The performance of a BTES (borehole thermal energy storage) system is primarily governed by ground heat flux, soil thermal properties and groundwater conditions. However, the design of the heat exchanger used within the BTES system can also make a significant difference in the efficiency of the system. A thermal response test was carded out for a Kelix GHE (ground heat exchanger) system, the latest innovation in geothermal ground loop construction, on an Ecofarm in the town of Caledon East, Ontario, Canada. In addition, a verifying test was performed for a CEES (conventional earth energy system) located 6 m away from the Kelix GHE. The boreholes for these two different heat exchanger designs were drilled with the same diameter, to the same depth and were located in the same/identical geo-hydrological conditions. The response test provided the effective average of undisturbed ground temperature, geothermal properties including thermal conductivity, heat capacity and thermal resistance between the fluid and the borehole wall. The mathematical analysis method used for the response test is presented here. Results of the response test were verified, analyzed and are further discussed.展开更多
基金This work was supported by the National Natural Science Foundation of China(U19B2005,21808238,U20B6005,22127812)the National Key Research and Development Program of China(2021YFC2800902).
文摘The natural gas hydrate has been regarded as an important future green energy.Significant progress on the hydrate exploitation has been made,but some challenges are still remaining.In order to enhance the hydrate exploitation efficiency,a significant understanding of the effective thermal conductivity(ETC)of the hydrate-bearing sediment has become essential,since it directly controls the heat and mass transfer behaviors,and thereby determines the stability of hydrate reservoir and production rate.In this study,the effective thermal conductivities of various hydrate-bearing sediments were in-situ measured and studied.The impacts of temperature,particle size and type of sediment were investigated.The effective thermal conductivities of the quartz sand sediments before and after hydrate formation were in-situ measured.The results show the weak negative correlation of effective thermal conductivity of the quartz sand sediment on the temperature before and after the hydrate formation.The effective thermal conductivity of the hydrate-bearing sediment decreases with the increase of particle size of the sediment.The dominant effect of the type of porous medium on the characteristics of the effective thermal conductivity of hydrate-bearing sediment was highlighted.The results indicate that both the effective thermal conductivities of hydrate-bearing quartz sand sediment and hydrate-bearing silicon carbide sediment are weakly negatively correlated with temperature,but the effective thermal conductivity of hydrate-bearing clay sediment is weakly positively dependent on the temperature.In addition,the values of the effective thermal conductivities of various hydrate-bearing sediments are in the order of hydrate-bearing silicon carbide sediment>hydrate-bearing quartz sand sediment>hydrate-bearing clay sediment.These findings could suggest that the intrinsic thermal conductivity of porous medium could control the characteristics of effective thermal conductivity of hydrate-bearing sediment.
基金supported by the National Science and Technology Project (No. Si-noProbe-07)National Basic Research Program of China (No. 2008cb425701)+1 种基金National Natural Science Foundation of China (No. 40774049)Institute of Earthquake Science,China Earthquake Administration,who provided us with the support from the collaborative project named as "Pre-study of several issues of testing ground for numerical forecast earthquakes in North China"
文摘In order to explore the thermal conductivity of the natural poly-mineral rock,numerical tests of rock models with randomly-distributed components were conducted and compared with each other.Elaborately designed Monte Carlo method was adopted to ingratiate the requirement of the random characteristics of grain size and the grains'spatial distribution.This requirement was fulfilled by clustering the randomly generated unstructured tetrahedral elements in full three dimensions.Natural rocks are consisted of randomly distributed crystal particles or intergranular minerals.Our primary results verify that the thermal conductivity of the rock is strongly sensitive to the ingredients' volume fraction and their spatial distribution.Furthermore,we proved that,in order to reduce the measurement error to a reasonable range,the numerical specimen must be large enough or include sufficient number of mineral particles.Our numerical test results are in accordance with a variety of empirical formulas which are currently employed in petrology.
基金Supported by Project of National Natural Science Foundation of China(No.41372239)
文摘The authors presented a new measuring method of the soil thermal conductivity,the probe method,which is designed and made based on the theory of line heat source. This method is used to measure thermal conductivity of coarse sand,fine sand and silty clay in different water contents. The results that measured by the probe method are well consistent with those of QTM-D_2. The soil thermal conductivity increases in different levels with the increase of the water content. Compared the soil thermal conductivity measured by the probe method in laboratory with in-situ experiment,it shows that the measuring gap gradually increases with the increase of the depth. The reason is that the in-situ measuring thermal conductivity can reflect the actual situation of the soil mass.
文摘This paper presents an experimental study on the evaluation of thermal response of a spiral coil type GHE (ground heat exchanger). This GHE was installed on partially saturated landfill ground that was composed of silt and clay in the runway area of Incheon International airport. TRT (thermal response test) was conducted for more than 65 hours under continuous operation conditions. Ground thermal conductivity was derived based on line source theory, which has usually been found to be appropriate for line type GHEs such as U, W and 2U types. A reasonable method to derive ground thermal conductivity using the infinite line source theory for a spiral coil type GHE was introduced. Ground thermal conductivity from the TRT using spiral coil type GHE was compared with those from the analytical equivalent model of ground thermal conductivity.
基金Projects(21107032,51073072)supported by the National Natural Science Foundation of ChinaProjects(Y406469,Y4110555,Y4100745)supported by Natural Science Foundation of Zhejiang Province,ChinaProjects(2011AY1048-5,2011AY1030)supported by the Science Foundation of Jiaxing Science and Technology Bureau,China
文摘Biodegradable poly (D,L-lactide) (PLA)/carboxyl-functionalized multi-walled carbon nanotubes (c-MWCNTs) composites were achieved via in-situ polymerization. These as-prepared composite materials were characterized with FT-IR, XRD, TG, DSC, SEM, and high insulation resistance meter. The results demonstrate that the multi-walled carbon nanotube was carboxyl functionalized, which improved the collection between c-MWCNTs and PLA, and further realized the graft copolymerization of c-MWCNTs and PLA. There is a higher glass transition temperature and a lower pyrolysis temperature of PLA/c-MWCNTs composites than pure PLA. The c-MWCNTs gave a better dispersion than unmodified MWCNTs in the PLA matrix, and an even coating of PLA on the surface of c-MWCNTs was obtained, which increased the interfacial interaction. High insulation resistance analysis showed that the addition of c-MWCNTs increased the electric conductivity, and c-MWCNTs performed against the large dielectric coefficient and electrostatic state of PLA. These results demonstrated that c-MWCNTs modified PLA composites were beneficial for potential application in the development of heat-resisting and conductivity plastic engineering.
基金Supported by the National Natural Science Foundation of China(No.41272263)
文摘An improved test rig providing both the heat and cold source was used to perform thermal response test (TRT), and the line source model was used for data analysis. The principle of determining the temperature difference between the inlet and outlet of test well can keep the heating or cooling rate constant, along with a reduced size of test rig. Among the influencial factors of the line source model, the temperature difference was determined as the most important, which agreed with the test results. When the gravel was taken as the backfill material, the soil thermal conductivities of heating and cooling at the test place were 1.883 W/(m·K) and 1.754 W/(m·K), respectively, and the deviation of TRT between heating and cooling soil was 6.8%. In the case of fine sand, the thermal conductivities of heating and cooling were 1.541 W/(m·K) and 1.486 W/(m·K), respectively, and the corresponding deviation was 6%. It was also concluded that different velocities of water had less influence on TRT than the temperature difference.
文摘The performance of a BTES (borehole thermal energy storage) system is primarily governed by ground heat flux, soil thermal properties and groundwater conditions. However, the design of the heat exchanger used within the BTES system can also make a significant difference in the efficiency of the system. A thermal response test was carded out for a Kelix GHE (ground heat exchanger) system, the latest innovation in geothermal ground loop construction, on an Ecofarm in the town of Caledon East, Ontario, Canada. In addition, a verifying test was performed for a CEES (conventional earth energy system) located 6 m away from the Kelix GHE. The boreholes for these two different heat exchanger designs were drilled with the same diameter, to the same depth and were located in the same/identical geo-hydrological conditions. The response test provided the effective average of undisturbed ground temperature, geothermal properties including thermal conductivity, heat capacity and thermal resistance between the fluid and the borehole wall. The mathematical analysis method used for the response test is presented here. Results of the response test were verified, analyzed and are further discussed.