The Spanish NGO “Alianza por la Solidaridad” has installed improved cookstoves in 3000 households during 2012 and 2013 to improve energy efficiency reducing fuelwood consumption and to improve indoor air quality. Th...The Spanish NGO “Alianza por la Solidaridad” has installed improved cookstoves in 3000 households during 2012 and 2013 to improve energy efficiency reducing fuelwood consumption and to improve indoor air quality. The type of cookstoves were Noflaye Jeeg and Noflaye Jaboot and were installed in the Cassamance Natural Subregion covering part of Senegal, The Gambia and Guinea-Bissau. The Technical University of Madrid (UPM) has conducted a field study on a sample of these households to assess the effect of improved cookstoves on kitchen air quality. Measurements of carbon monoxide (CO) and fine particle matter (PM2.5) were taken for 24-hr period before and after the installation of improved cookstoves. The 24-hr mean CO concentrations were lower than the World Health Organization (WHO) guidelines for Guinea-Bissau but higher for Senegal and Gambia, even after the installation of improved cookstoves. As for PM2.5 concentrations, 24-hr mean were always higher than these guidelines. However, improved cookstoves produced significant reductions on 24-hr mean CO and PM2.5 concentrations in Senegal and for mean and maximum PM2.5 concentration on Gambia. Although this variability needs to be explained by further research to determine which other factors could affect indoor air pollution, the study provided a better understanding of the problem and envisaged alternatives to be implemented in future phases of the NGO project.展开更多
Objective To investigate the annual effective doses from indoor radon received by academic staff in the Faculty building. Methods Measurements of indoor radon concentrations were performed in the Arts and Sciences Fac...Objective To investigate the annual effective doses from indoor radon received by academic staff in the Faculty building. Methods Measurements of indoor radon concentrations were performed in the Arts and Sciences Faculty of Dokuz Eylul University for two surveys of about 1 month duration respectively using the SSNTD (Solid State Nuclear Track Detectors) method with LR115 detectors. Time integrated measurements comprised different locations inside the faculty building: classrooms, toilets, canteen and offices. Homes of academic staff were also tested for radon. Results The aritthmetic mean radon concentration is 161 Bq m-3 with a range between 40 and 335 Bq m-3 in the Faculty. Six offices and three classrooms have a radon concentration above 200 Bq m-3. The results show that the radon concentration in classrooms is generally higher than in offices. Based on the measured indoor radon data, the annual effective doses received by staff in the Faculty were estimated to range from 0.79 to 4.27 mSv, according to UNSCEAR methodology. The annual effective doses received by staff ranged from 0.78 to 4.20 mSv in homes. On average, the Faculty contributed 56% to the annual effective dose. Conclusion Reported values for radon concentrations and corresponding doses are within the ICRP recommended limits for workplaces.展开更多
Objective The custom-homebuilding company, Cosmic Garden Co. Ltd., located in Okayama City, Japan was established in 1997 and uses specific natural ore powder (SNOP) in wall materials and surveys customers in order ...Objective The custom-homebuilding company, Cosmic Garden Co. Ltd., located in Okayama City, Japan was established in 1997 and uses specific natural ore powder (SNOP) in wall materials and surveys customers in order to improve allergic symptoms. Methods To investigate the biological effects of SNOP, patients with a pollen allergy were recruited to stay in a room surrounded by cloth containing SNOP (CCSNOP), and their symptoms and various biological parameters were compared with those of individuals staying in a room surrounded by control non-woven cloth (NWC). Each stay lasted 60 min. Before and immediately after the stay, a questionnaire regarding allergic symptoms, as well as POMS (Profile of Mood Status) and blood sampling, was performed. Post-stay minus pre-stay values were calculated and compared between CCSNOP and NWC groups. Results Results indicated that some symptoms, such as nasal obstruction and lacrimation, improved, and POMS evaluation showed that patients were calmer following a stay in CCSNOP. Relative eosinophils, non-specific Ig E, epidermal growth factor, monocyte chemotactic protein-I, and tumor necrosis factor-a increased following a stay in CCSNOP. Conclusion This ore powder improved allergic symptoms, and long-term monitoring involving 1 to 2 months may be necessary to fully explore the biological and physical effects of SNOP on allergic patients.展开更多
文摘The Spanish NGO “Alianza por la Solidaridad” has installed improved cookstoves in 3000 households during 2012 and 2013 to improve energy efficiency reducing fuelwood consumption and to improve indoor air quality. The type of cookstoves were Noflaye Jeeg and Noflaye Jaboot and were installed in the Cassamance Natural Subregion covering part of Senegal, The Gambia and Guinea-Bissau. The Technical University of Madrid (UPM) has conducted a field study on a sample of these households to assess the effect of improved cookstoves on kitchen air quality. Measurements of carbon monoxide (CO) and fine particle matter (PM2.5) were taken for 24-hr period before and after the installation of improved cookstoves. The 24-hr mean CO concentrations were lower than the World Health Organization (WHO) guidelines for Guinea-Bissau but higher for Senegal and Gambia, even after the installation of improved cookstoves. As for PM2.5 concentrations, 24-hr mean were always higher than these guidelines. However, improved cookstoves produced significant reductions on 24-hr mean CO and PM2.5 concentrations in Senegal and for mean and maximum PM2.5 concentration on Gambia. Although this variability needs to be explained by further research to determine which other factors could affect indoor air pollution, the study provided a better understanding of the problem and envisaged alternatives to be implemented in future phases of the NGO project.
基金supported by a grant of The Scientific and Technical Research Council of Turkey(TUBiTAK)
文摘Objective To investigate the annual effective doses from indoor radon received by academic staff in the Faculty building. Methods Measurements of indoor radon concentrations were performed in the Arts and Sciences Faculty of Dokuz Eylul University for two surveys of about 1 month duration respectively using the SSNTD (Solid State Nuclear Track Detectors) method with LR115 detectors. Time integrated measurements comprised different locations inside the faculty building: classrooms, toilets, canteen and offices. Homes of academic staff were also tested for radon. Results The aritthmetic mean radon concentration is 161 Bq m-3 with a range between 40 and 335 Bq m-3 in the Faculty. Six offices and three classrooms have a radon concentration above 200 Bq m-3. The results show that the radon concentration in classrooms is generally higher than in offices. Based on the measured indoor radon data, the annual effective doses received by staff in the Faculty were estimated to range from 0.79 to 4.27 mSv, according to UNSCEAR methodology. The annual effective doses received by staff ranged from 0.78 to 4.20 mSv in homes. On average, the Faculty contributed 56% to the annual effective dose. Conclusion Reported values for radon concentrations and corresponding doses are within the ICRP recommended limits for workplaces.
基金the Kirameki Creation Fund from the Okayama Prefecture Industrial Promotion Foundation from January to September,2014
文摘Objective The custom-homebuilding company, Cosmic Garden Co. Ltd., located in Okayama City, Japan was established in 1997 and uses specific natural ore powder (SNOP) in wall materials and surveys customers in order to improve allergic symptoms. Methods To investigate the biological effects of SNOP, patients with a pollen allergy were recruited to stay in a room surrounded by cloth containing SNOP (CCSNOP), and their symptoms and various biological parameters were compared with those of individuals staying in a room surrounded by control non-woven cloth (NWC). Each stay lasted 60 min. Before and immediately after the stay, a questionnaire regarding allergic symptoms, as well as POMS (Profile of Mood Status) and blood sampling, was performed. Post-stay minus pre-stay values were calculated and compared between CCSNOP and NWC groups. Results Results indicated that some symptoms, such as nasal obstruction and lacrimation, improved, and POMS evaluation showed that patients were calmer following a stay in CCSNOP. Relative eosinophils, non-specific Ig E, epidermal growth factor, monocyte chemotactic protein-I, and tumor necrosis factor-a increased following a stay in CCSNOP. Conclusion This ore powder improved allergic symptoms, and long-term monitoring involving 1 to 2 months may be necessary to fully explore the biological and physical effects of SNOP on allergic patients.