The development of laser sampling for optical emission spectrometry is reviewed . Advantages and limitations of pulsed laser sampling are compared with those of continuous laser sampling . A novel method of laser samp...The development of laser sampling for optical emission spectrometry is reviewed . Advantages and limitations of pulsed laser sampling are compared with those of continuous laser sampling . A novel method of laser sampling of liquid samples for inductively coupled plasma -atomic emission spectrometry has been proposed , and its analytical performance investigated.Experimental results showed that,as a method of sample introduction , laser vaporization of liquid samples enjoyed certain advantages , e.g.,much higher sensitivity, much lower detection limit and reduced sample volume , over solution nebulization . A perspective of the application of laser sampling-inductively coupled plasma - actomic emission spectrometry for rock and mineral analysis is estimated as well.展开更多
A method based on the combination of coprecipitation with inductively coupledplasma atomic emission spectrometry (ICP-AES) was developed for the determination of impurities inhigh-purity sodium tungstate. Six elements...A method based on the combination of coprecipitation with inductively coupledplasma atomic emission spectrometry (ICP-AES) was developed for the determination of impurities inhigh-purity sodium tungstate. Six elements (Co, Cu, Fe, Mn, Ni, and Pb) were coprecipitated bylanthanum hydroxide so as to be concentrated and separated from the tungsten matrix. Effects of somefactors on the recoveries of the analytes and on the residual amount of sodium tungstate wereinvestigated, and the optimum conditions for the coprecipitation were proposed. Matrix-matchingcalibration curve method was used for the analysis. It is shown that the elements mentioned abovecan be quantitatively recovered. The detection limits for Co, Cu, Fe, Mn, Ni, and Pb are 0.07, 0.4,0.2, 0.1, 0.6, and 1.3 μg·g^(-1), respectively. The recoveries vary from 92.5% to 108%, and therelative standard deviations (RSDs) are in the range of 3.1%-5.5%.展开更多
A rapid method for the determination of impurity elements, such as Zn, Ni, Co, Cr, Cu, Cd and Pb in manganese tetroxide was developed, using inductively coupled plasma atomic emission spectrometry (ICP-AES). The cri...A rapid method for the determination of impurity elements, such as Zn, Ni, Co, Cr, Cu, Cd and Pb in manganese tetroxide was developed, using inductively coupled plasma atomic emission spectrometry (ICP-AES). The critical instrumental parameters such as sample flow rate and radio frequency incident were thoroughly optimized. The effect of matrix was also examined. The sensitivity was investigated using calibration curves obtained in presence of the matrix. The obtained recoveries for Ni, Co, Cr, Cu, and Cd at the μg· g^ -1 level were satisfactory and practically independent of the matrix used for the calibration standards. The recoveries of Pb and Zn were less suffwient. The method can be applied for routine analysis and quality control purposes at μg· g^-1 level of concentration.展开更多
Concentration of heavy metals in blood and urine of rabbit after inhaling three different kinds of cigarette was studied through the animal passive smoking pattern. The samples were prepared by nitric acid solution di...Concentration of heavy metals in blood and urine of rabbit after inhaling three different kinds of cigarette was studied through the animal passive smoking pattern. The samples were prepared by nitric acid solution digestion and determination of seven kinds of heavy metals including Hg, Se, Sn, Pb, Cd, Ni and Cr was performed by inductively coupled plasma-atomic emission spectrometry (ICP-AES). The ICP-AES method was established with good precision and accuracy, relative standard deviation (n=6) was between 2.9% and 5.9%, and the recovery was in the range of 95.0%-104.2%. Concentration of six heavy metals increases in some extent in blood and urine after period of smoking and the increasing of heavy metals in blood and urine all shows time dependence. Significantly higher heavy metal levels are observed in the blood and urine of the cigarette inhaling rabbits in the exposed group. The concentration of six kinds of heavy metals in the blood of the rabbit increases after 16 weeks exposing to cigarette smoking. Three times of rig, ten times of Se and trace amount ofPb, Cd, Ni and Cr are detected in the blood after 16 weeks of smoking. For urine samples, about three times of Hg, two times of Se, five times of Pb and trace amount of Cd are detected after 16 weeks of inhalation of cigarette. Comparatively, higher concentration of heavy metals are detected after inhaling of Nise cigarette.展开更多
One of the most important problems facing the gold industry is that the placer and free milling gold ores are almost terminating. Hence, the use of refractory ores has been increased during the recent years. In genera...One of the most important problems facing the gold industry is that the placer and free milling gold ores are almost terminating. Hence, the use of refractory ores has been increased during the recent years. In general, gold refractory ores occurs in various types of deposits associated with a range of minerals. Among the refractory ores, the sulfide type is the most common. The methodology employed in the mining process depends on the mode of occurrence of the ore and on the particle size, shape and degree of purity of the auriferous species. We have undertaken a mineralogical investigation of a representative sample of a complex gold mining ore collected in the municipality of Princesa Isabel, Paraiba, Brazil, using X-ray fluorescence spectrometry, X-ray diffractometry, infrared spectroscopy, inductively coupled plasma-atomic emission spectrometry and the Fire Assay. The results showed that the arsenic content of the ore was closely related to the gold content, and that the occurrence of “invisible gold” was associated primarily with pyrite and secondarily with arsenopyrite. The sulfur content of the ore was directly related to its refractoriness. It is concluded that gold mineralization in the study area is mainly of the gold-quartz-sulfide veins (lode gold), while the gold found in the mini-fractures of the deposits is probably associated with the hydrothermal processes that occurred in the region.展开更多
文摘The development of laser sampling for optical emission spectrometry is reviewed . Advantages and limitations of pulsed laser sampling are compared with those of continuous laser sampling . A novel method of laser sampling of liquid samples for inductively coupled plasma -atomic emission spectrometry has been proposed , and its analytical performance investigated.Experimental results showed that,as a method of sample introduction , laser vaporization of liquid samples enjoyed certain advantages , e.g.,much higher sensitivity, much lower detection limit and reduced sample volume , over solution nebulization . A perspective of the application of laser sampling-inductively coupled plasma - actomic emission spectrometry for rock and mineral analysis is estimated as well.
文摘A method based on the combination of coprecipitation with inductively coupledplasma atomic emission spectrometry (ICP-AES) was developed for the determination of impurities inhigh-purity sodium tungstate. Six elements (Co, Cu, Fe, Mn, Ni, and Pb) were coprecipitated bylanthanum hydroxide so as to be concentrated and separated from the tungsten matrix. Effects of somefactors on the recoveries of the analytes and on the residual amount of sodium tungstate wereinvestigated, and the optimum conditions for the coprecipitation were proposed. Matrix-matchingcalibration curve method was used for the analysis. It is shown that the elements mentioned abovecan be quantitatively recovered. The detection limits for Co, Cu, Fe, Mn, Ni, and Pb are 0.07, 0.4,0.2, 0.1, 0.6, and 1.3 μg·g^(-1), respectively. The recoveries vary from 92.5% to 108%, and therelative standard deviations (RSDs) are in the range of 3.1%-5.5%.
基金Supported bythe financial support of Sino-Romanian GovernmentalInternational Science and Technology Cooperation Projeet( No.37-11)the Scientific and Technological Project of Tackle Key Problemin Science and Technology Branch of Hunan Province ( No.00GKY2020 +4 种基金01GKY2027 03GKY2022)Key Project of Hunan Pro-vincial Educational Branch(No.02A040) Key Project of RegionalUniversityin Chinese Ministry of Education(No.204103)and Fundfor Returned Overseas Scholars ,China University of Geosciences(No.XLX04901)
文摘A rapid method for the determination of impurity elements, such as Zn, Ni, Co, Cr, Cu, Cd and Pb in manganese tetroxide was developed, using inductively coupled plasma atomic emission spectrometry (ICP-AES). The critical instrumental parameters such as sample flow rate and radio frequency incident were thoroughly optimized. The effect of matrix was also examined. The sensitivity was investigated using calibration curves obtained in presence of the matrix. The obtained recoveries for Ni, Co, Cr, Cu, and Cd at the μg· g^ -1 level were satisfactory and practically independent of the matrix used for the calibration standards. The recoveries of Pb and Zn were less suffwient. The method can be applied for routine analysis and quality control purposes at μg· g^-1 level of concentration.
基金Project(11JJ5053) supported by the Provincial Natural Science Foundation of Hunan Province,China
文摘Concentration of heavy metals in blood and urine of rabbit after inhaling three different kinds of cigarette was studied through the animal passive smoking pattern. The samples were prepared by nitric acid solution digestion and determination of seven kinds of heavy metals including Hg, Se, Sn, Pb, Cd, Ni and Cr was performed by inductively coupled plasma-atomic emission spectrometry (ICP-AES). The ICP-AES method was established with good precision and accuracy, relative standard deviation (n=6) was between 2.9% and 5.9%, and the recovery was in the range of 95.0%-104.2%. Concentration of six heavy metals increases in some extent in blood and urine after period of smoking and the increasing of heavy metals in blood and urine all shows time dependence. Significantly higher heavy metal levels are observed in the blood and urine of the cigarette inhaling rabbits in the exposed group. The concentration of six kinds of heavy metals in the blood of the rabbit increases after 16 weeks exposing to cigarette smoking. Three times of rig, ten times of Se and trace amount ofPb, Cd, Ni and Cr are detected in the blood after 16 weeks of smoking. For urine samples, about three times of Hg, two times of Se, five times of Pb and trace amount of Cd are detected after 16 weeks of inhalation of cigarette. Comparatively, higher concentration of heavy metals are detected after inhaling of Nise cigarette.
基金the Conselho Nacional de Desenvolvimento Cientifico e Tecnologico(CNPq,grant no.550261/2010-9)for financial support
文摘One of the most important problems facing the gold industry is that the placer and free milling gold ores are almost terminating. Hence, the use of refractory ores has been increased during the recent years. In general, gold refractory ores occurs in various types of deposits associated with a range of minerals. Among the refractory ores, the sulfide type is the most common. The methodology employed in the mining process depends on the mode of occurrence of the ore and on the particle size, shape and degree of purity of the auriferous species. We have undertaken a mineralogical investigation of a representative sample of a complex gold mining ore collected in the municipality of Princesa Isabel, Paraiba, Brazil, using X-ray fluorescence spectrometry, X-ray diffractometry, infrared spectroscopy, inductively coupled plasma-atomic emission spectrometry and the Fire Assay. The results showed that the arsenic content of the ore was closely related to the gold content, and that the occurrence of “invisible gold” was associated primarily with pyrite and secondarily with arsenopyrite. The sulfur content of the ore was directly related to its refractoriness. It is concluded that gold mineralization in the study area is mainly of the gold-quartz-sulfide veins (lode gold), while the gold found in the mini-fractures of the deposits is probably associated with the hydrothermal processes that occurred in the region.