期刊文献+
共找到4,619篇文章
< 1 2 231 >
每页显示 20 50 100
Determination on Heavy Metals Content of Achyranthes bidentata Blume. through Inductively Coupled Plasma Mass Spectrometry (ICP-MS) 被引量:4
1
作者 李宇伟 王新民 +3 位作者 连瑞丽 魏志华 介晓磊 陈士林 《Agricultural Science & Technology》 CAS 2008年第5期145-149,共5页
[Objective] The inductively coupled plasma mass spectrometry(ICP-MS)was constructed to determine the contents of lead,cadmium,mercury and arsenic in Archyranthes bidentata Blume.[Method]Under the optimum operation con... [Objective] The inductively coupled plasma mass spectrometry(ICP-MS)was constructed to determine the contents of lead,cadmium,mercury and arsenic in Archyranthes bidentata Blume.[Method]Under the optimum operation condition of ICP-MS,the samples were digested by microwave.The element 114In was taken as an internal standard element to compensate body effect and ICP-MS method was used to determine the contents of lead,cadmium,mercury and arsenic.[Result]For the determined elements,the correlation coefficient(r)of standard curve was over 0.9995 and recovery rate was from 96.7% to 106.4% while RSD was less than 11.2%.The result of determination showed that the heavy metal content in Archyranthes bidentata Blume.beyond standard was serious.[Conclusion]The constructed ICP-MS method with simple operation,rapid response,accuracy and high sensitivity in this experiment could be used for quality control of Chinese medicinal materials by detecting heavy metal contents in different Chinese medicinal materials from original places. 展开更多
关键词 MICROWAVE DIGESTION inductively coupled plasma mass spectrometry(icp-ms) Achyranthes bidentata Blume. HEAVY metal
下载PDF
Analysis of Cu,Co,V and Zn in Coastal Waters of the East China Sea by Inductively Coupled Plasma Mass Spectrometry(ICP-MS) 被引量:1
2
作者 YANG Rujun NING Yutong +2 位作者 ZHANG Aibin LI Yan SU Han 《Journal of Ocean University of China》 SCIE CAS 2016年第5期825-834,共10页
In this study, a simple method for the simultaneous determination of trace metals(Cu, V, Co, Zn) in coastal seawater using the Mg(OH)2 coprecipitation inductively coupled plasma mass spectrometry(ICP-MS) was developed... In this study, a simple method for the simultaneous determination of trace metals(Cu, V, Co, Zn) in coastal seawater using the Mg(OH)2 coprecipitation inductively coupled plasma mass spectrometry(ICP-MS) was developed. This multi-element method enables the simultaneous extraction of four metals, particularly Co and V. The recoveries of Cu, Co, V and Zn after Mg(OH)2 coprecipitation were 73%, 96%, 94% and 92%, which means that our procedure was well-suited to the determination of these four trace metals. The detection limits were 3.81, 0.18, 6.09 and 1.91 nmol L-1, respectively. Then, applying this method to the simultaneous determination of these four metals in coastal water samples from the East China Sea revealed that the concentrations of Cu, Zn, Co and V were higher in bottom waters compared to water at other depths, and higher concentrations were generally observed at the Yangtze River estuary. Additionally, example vertical profiles of dissolved trace metal concentrations for the East China Sea in spring and autumn are compared. These findings indicate that Zn had the greatest seasonal variation followed by Cu, V and Co. For Zn and Co, the concentrations were higher during spring than during autumn. For Cu and V, the seasonal variation in the concentrations was opposite. 展开更多
关键词 simultaneous dissolved inductively seasonal autumn seawater greatest ammonium waters hydroxide
下载PDF
Inductively coupled plasma mass spectrometry (ICP-MS) and its application in life sciences
3
作者 徐谷峰 王红梅 《Plasma Science and Technology》 SCIE EI CAS CSCD 2001年第4期921-925,共5页
Inductively-coupled plasma mass spectrometry (ICP-MS) has made much progress since its birth in the late 1990s. This paper will give a rather systematic overview on the use of this technique in new devices and technol... Inductively-coupled plasma mass spectrometry (ICP-MS) has made much progress since its birth in the late 1990s. This paper will give a rather systematic overview on the use of this technique in new devices and technologies related to plasma source, sample-introducing device and detecting spectrometer etc. In this overview, an emphasis will be put on the evaluation of the ICP- MS technique in combination with a series of physical, chemical and biological techniques, such as laser ablation (LA), capillary electrophoresis (CE) and high performance liquid chromatograph (HPLC), along with their representative high accuracy and high sensitivity. Finally, comprehensive and fruitful applications of the ICP-MS and its combinative techniques in the detection of trace metallic elements and isotopes in complex biological and environmental samples will be revealed. 展开更多
关键词 icp-ms inductively coupled plasma mass spectrometry and its application in life sciences MS
下载PDF
Quantification of trace amounts of impurities in high purity cobalt by high resolution inductively coupled plasma mass spectrometry 被引量:10
4
作者 XIE Hualin HUANG Kelong +1 位作者 NIE Xidu TANG Yougen 《Rare Metals》 SCIE EI CAS CSCD 2007年第3期286-291,共6页
A An analytical method using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for rapid simultaneous determination of 24 elements (Be, Mg, A1, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Ge, As, Se, ... A An analytical method using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for rapid simultaneous determination of 24 elements (Be, Mg, A1, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Ge, As, Se, Mo, Ag, Cd, Sn Sb, Ba, Pt, Au, and Pb) in high purity cobalt was described. Sample digestions were performed in closed microwave vessels using HNO3 and HCI. The matrix effects because of the presence of excess HCI and Co were evaluated. The usefulness of high mass resolution for overcoming some spectral interference was demonstrated. The optimum conditions for the determination were tested and discussed. The standard addition method was employed for quantitative analysis. The detection limits were 0.016-1.50 ].tg·g^-1, the recovery ratios were 92.2%-111.2%, and the RSD was less than 3.6%. The method was accurate, quick, and convenient. It was applied to the determination of trace impurities in high purity cobalt with satisfactory results. 展开更多
关键词 high resolution inductively coupled plasma mass spectrometry high purity cobalt trace impurities matrix effect standard addition method
下载PDF
Determination of trace elements in high purity nickel by high resolution inductively coupled plasma mass spectrometry 被引量:11
5
作者 聂西度 梁逸曾 +1 位作者 唐有根 谢华林 《Journal of Central South University》 SCIE EI CAS 2012年第9期2416-2420,共5页
The contents ofMg, Al, Si, Ti, Cr, Mn, Fe, Co, Cu, Ga, As, Se, Cd, Sb, Pb and Bi in high purity nickel were determined by high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). The sample was diss... The contents ofMg, Al, Si, Ti, Cr, Mn, Fe, Co, Cu, Ga, As, Se, Cd, Sb, Pb and Bi in high purity nickel were determined by high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). The sample was dissolved in HNO3 and HCI by microwave digestion. Most of the spectral interferences could be avoided by measuring in the high resolution mode. The matrix effects because of the presence of excess HC1 and nickel were evaluated. Correction for matrix effects was made using Sc, Rh and T1 as internal standards. The optimum conditions for the determination were tested and discussed. The detection limits range from 0.012 to 1.76 ~tg/g depending on the type of elements. The applicability of the proposed method is also validated by the analysis of high purity nickel reference material (NIST SRM 671). The relative standard deviation (RSD) is less than 3.3%. Results for determination of trace elements in high purity nickel were presented. 展开更多
关键词 high resolution inductively coupled plasma mass spectrometry high purity nickel trace element matrix effect internal standard
下载PDF
Quantification of Trace Amounts of Impurities in High Purity Cobalt by High Resolution Inductively Coupled Plasma Mass Spectrometry 被引量:3
6
作者 Hua Lin XIE Xi Du NIE You Gen TANG 《Chinese Chemical Letters》 SCIE CAS CSCD 2006年第8期1077-1080,共4页
An analytical method using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for rapid simultaneous determination of Be, Mg, Al, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Ge, As, Se, Mo, Ag, Cd, Sn, ... An analytical method using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for rapid simultaneous determination of Be, Mg, Al, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Ge, As, Se, Mo, Ag, Cd, Sn, Sb, Ba, Pt, Au and Pb in high purity cobalt was described. Sample digestions were performed in closed microwave vessels using HNO3 and HCl. The matrix effects due to the presence of excess HCl and Co were evaluated. The usefulness of high mass resolution for overcoming some spectral interference was demonstrated. The optimum conditions for the determination was tested and discussed. Correction for matrix effects, Sc, Rh and Bi were used as internal standards. The detection limits is 0.003-0.57 μg/g, the recovery ratio is 92.2%-111.2%, and the RSD is less than 3.6%. The method is accurate, quick and convenient. It has been applied to the determination of trace impurities in high purity cobalt with satisfactory results. 展开更多
关键词 High resolution inductively coupled plasma mass spectrometry high purity cobalt trace impurities matrix effect spectral interference internal standards.
下载PDF
The determination of 52 elements in marine geological samples by an inductively coupled plasma optical emission spectrometry and an inductively coupled plasma mass spectrometry with a high-pressure closed digestion method 被引量:16
7
作者 GAO Jingjing LIU Jihua +3 位作者 LI Xianguo YAN Quanshu WANG Xiaojing WANG Hongmin 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2017年第1期109-117,共9页
An improved analytical method to determine the content of 52 major, minor and trace elements in marine geological samples, using a HF-HCl-HNO_3 acid system with a high-pressure closed digestion method(HPCD), is stud... An improved analytical method to determine the content of 52 major, minor and trace elements in marine geological samples, using a HF-HCl-HNO_3 acid system with a high-pressure closed digestion method(HPCD), is studied by an inductively coupled plasma optical emission spectrometry(ICP-OES) and an inductively coupled plasma mass spectrometry(ICP-MS). The operating parameters of the instruments are optimized, and the optimal analytical parameters are determined. The influences of optical spectrum and mass spectrum interferences, digestion methods and acid systems on the analytical results are investigated. The optimal spectral lines and isotopes are chosen, and internal standard element of rhodium is selected to compensate for matrix effects and analytical signals drifting. Compared with the methods of an electric heating plate digestion and a microwave digestion, a high-pressure closed digestion method is optimized with less acid, complete digestion,less damage for digestion process. The marine geological samples are dissolved completely by a HF-HCl-HNO_3 system, the relative error(RE) for the analytical results are all less than 6.0%. The method detection limits are 2–40μg/g by the ICP-OES, and 6–80 ng/g by ICP-MS. The methods are used to determine the marine sediment reference materials(GBW07309, GBW07311, GBW07313), rock reference materials(GBW07103, GBW07104,GBW07105), and cobalt-rich crust reference materials(GBW07337, GBW07338, GBW07339), the obtained analytical results are in agreement with the certified values, and both of the relative standard deviation(RSD) and the relative error(RE) are less than 6.0%. The analytical method meets the requirements for determining 52 elements contents of bulk marine geological samples. 展开更多
关键词 marine geological sample high-pressure closed digestion method inductively coupled plasma optical emission spectrometry inductively coupled plasma mass spectrometry major element minor element trace element
下载PDF
Determination of trace multi-elements in coal fly ash by inductively coupled plasma mass spectrometry 被引量:5
8
作者 谢华林 唐有根 +1 位作者 李玉杰 李立波 《Journal of Central South University of Technology》 EI 2007年第1期68-72,共5页
The contents of Cr, Cu, Ni, As, Cd and Pb in coal fly ash were determined by a high resolution inductively coupled plasma mass spectrometry method. The sample digestions were performed in closed microwave vessels with... The contents of Cr, Cu, Ni, As, Cd and Pb in coal fly ash were determined by a high resolution inductively coupled plasma mass spectrometry method. The sample digestions were performed in closed microwave vessels with HNO3, HClO4 and FIE The optimum conditions for the determination were obtained. The applicability of the proposed method was validated by the analysis of coal fly ash reference material (NIST SRM 1633a). The results show that most of the spectral interferences can be avoided by measuring in the high resolution mode (maximum mass resolution R=9 000). The detection limit is from 0.05 to 0.21 μg/g, and the precision is fine with relative standard deviation less than 4.3%. 展开更多
关键词 coal fly ash microwave digestion inductively coupled plasma mass spectrometry DETERMINATION
下载PDF
Direct Determination of Trace Impurities in High Purity Zinc Oxide by High Resolution Inductively Coupled Plasma Mass Spectrometry 被引量:2
9
作者 谢华林 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2006年第2期28-32,共5页
The determination of trace impurities in high purity zinc oxide by high resolution inductively coupled plasma mass spectrometry ( HR-ICP-MS ) was investigated. To overcome some poteutially problematic spectral iuter... The determination of trace impurities in high purity zinc oxide by high resolution inductively coupled plasma mass spectrometry ( HR-ICP-MS ) was investigated. To overcome some poteutially problematic spectral iuterference, measurements were acquired in both middle and high resolution modes. The matrix effects due to the presence of excess HCl and zinc were evaluated. The optimum conditions for the determination were tested and discussed. The standard addition method was employed for quantitative analysis. The detection limits ranged from 0.02μg/ g to 6 μg/ g depending on the elements. The experimental resalts for the determination of Na, Mg, Ca, Cr, Mn, Fe, Co, Ni, Cu, Mo, Cd, Sb and Pb in several high purity zinc oxide powders were presented. 展开更多
关键词 high purity zinc oxide trace impurities high resolution inductively coupled plasma mass spectrometry spectral interferences microwave digestion
下载PDF
Trace amounts of impurities in electrolytic manganese metal by sector field inductively coupled plasma mass spectrometry 被引量:2
10
作者 聂西度 梁逸曾 +1 位作者 唐有根 谢华林 《Journal of Central South University》 SCIE EI CAS 2013年第12期3385-3390,共6页
An analytical method, using sector field inductively coupled plasma mass spectrometry (SF-ICP-MS) for rapid simultaneous determination of Be, Na, Mg, Si, Ca, Ti, V, Cr, Fe, Co, Ni, Cu, Zn, As, Sn, Sb, Pb and Bi in e... An analytical method, using sector field inductively coupled plasma mass spectrometry (SF-ICP-MS) for rapid simultaneous determination of Be, Na, Mg, Si, Ca, Ti, V, Cr, Fe, Co, Ni, Cu, Zn, As, Sn, Sb, Pb and Bi in electrolytic manganese metal, was described. At the beginning, the samples were decomposed by HNO3 and H2504, and then analyzed by SF-ICP-MS. Most of the spectral interferences could be avoided by measuring in different mass resolution modes. The matrix effects due to the excess of sulfuric acid and Mn were evaluated. Correction of matrix effects was conducted by using the internal standard elements. The optimum condition for the determination was investigated and discussed. The detection limit is in the range of 0.001-0.169 gg/L. The current method is applied to the determination of trace impurities in electrolytic manganese metal. And experiments show that good results can be obtained much faster, more accurately and conveniently by current method. 展开更多
关键词 sector field inductively coupled plasma mass spectrometry electrolytic manganese IMPURITIES spectral interferences matrix effects
下载PDF
Determination of Trace Elements in High Purity Gold by High Resolution Inductively Coupled Plasma Mass Spectrometry 被引量:1
11
作者 谢华林 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2009年第4期608-612,共5页
Trace elements were determined in high purity gold by high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). Sample were decomposed by aqua regia. To overcome some potentially problematic spectra/... Trace elements were determined in high purity gold by high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). Sample were decomposed by aqua regia. To overcome some potentially problematic spectra/ interference, measurements were acquired in both medium and high resolution modes. The matrix effects due to the presence of excessive HCl and Au were evaluated. The optimum conditions for the determination was tested and discussed. The standard addition method was employed for quantitative analysis. The detection limits range from 0.01ug/g to 0.28ug/g depending on the elements. The method is accurate, quick and convenient. It has been applied to the determination of trace elements in high purity gold with satisfactory results. 展开更多
关键词 high purity gold trace elements high resolution inductively coupled plasma mass spectrometry spectral interferences
下载PDF
Determination of impurity elements in MnZn ferrites by inductively coupled plasma mass spectrometry 被引量:3
12
作者 张萍 符靓 +1 位作者 马俊才 唐有根 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第1期37-42,共6页
An inductively coupled plasma mass spectrometry(ICP-MS) method was developed for the determination of Na, Mg, Al,K, Ca, Ti, Cr, Co, Ni, Cu, Ga, As, Mo, Ag, Cd and Pb in MnZn ferrites. The sample was digested by HNO3+H... An inductively coupled plasma mass spectrometry(ICP-MS) method was developed for the determination of Na, Mg, Al,K, Ca, Ti, Cr, Co, Ni, Cu, Ga, As, Mo, Ag, Cd and Pb in MnZn ferrites. The sample was digested by HNO3+HCl with microwave digestion followed by dilution with ultrapure water, then the above 16 impurity elements in the solution were analyzed directly by ICP-MS. The impurity elements were introduced by the helium gas or hydrogen gas into the octopole reaction system(ORS) to eliminate the polyatomic interferences caused by the high salty matrixes. The matrix effect was minimized through matrix matching,and Be, Y and Rh were used as internal standard elements. The working parameters of the instrument were optimized. The results show that the method has good precision and high accuracy. The detection limits for the investigated elements are in the range of0.9-37.5 ng/L, the relative standard deviation of each element is within 1.1%-4.8%, and the recovery of each element is 90%-108%. 展开更多
关键词 inductively coupled plasma mass spectrometry(icp-ms MnZn ferrites octopole reaction system(ORS) impurity elements
下载PDF
Speciation of Volatile Selenium Species in Plants Using Gas Chromatography/Inductively Coupled Plasma Mass Spectrometry 被引量:1
13
作者 Juris MEIJA Maria MONTES-BAYN +2 位作者 Joseph A CARUSO Danika L LEDUC Norman TERRY 《色谱》 CAS CSCD 北大核心 2004年第1期16-19,共4页
Gas chromatography/inductively coupled plasma mass spectrometry (GC/ICP-MS) coupled with solid phase micro-extraction can provide a simple, extremely selective and sensitive technique for the analysis of volatile sulf... Gas chromatography/inductively coupled plasma mass spectrometry (GC/ICP-MS) coupled with solid phase micro-extraction can provide a simple, extremely selective and sensitive technique for the analysis of volatile sulfur and selenium compounds in the headspace of growing plants. In this work, the technique was used to evaluate the volatilization of selenium in wild-type and genetically-modified Brassica juncea seedlings. By converting toxic inorganic selenium in the soil to less toxic, volatile organic selenium, B. juncea might be useful in bioremediation of selenium contaminated soil. 展开更多
关键词 植物 挥发性硒化合物 含量测定 气相色谱法 电感耦合等离子体质谱法
下载PDF
Uncertainty Evaluation of Simultaneous Determination of Lead, Cadmium and Arsenic in Cosmetics by Inductively Coupled Plasma Mass Spectrometry 被引量:1
14
作者 Cui Xiaojiao Wang Hui +3 位作者 Zhou Peng Zhou Tanchun Cao Xiongjie Hu Yuge 《China Detergent & Cosmetics》 2020年第1期68-74,共7页
This study aimed to evaluate the uncertainty of simultaneous determination of lead(Pb),cadmium(Cd)and arsenic(As)in cosmetics by microwave digestion-inductively coupled plasma mass spectrometry(ICP-MS)with ^72Ge,^115I... This study aimed to evaluate the uncertainty of simultaneous determination of lead(Pb),cadmium(Cd)and arsenic(As)in cosmetics by microwave digestion-inductively coupled plasma mass spectrometry(ICP-MS)with ^72Ge,^115In and ^209Bi as internal standards.According to the method of Safety and Technical Standards for Cosmetics(2015),a mathematical model was established to evaluate the sources and components of uncertainty for the determination of lead,cadmium and arsenic in cosmetics.The results showed that the uncertainties in the determination of lead,cadmium,and arsenic elements in cosmetics were(10.1±0.6)mg/kg,k=2,(4.84±0.28)mg/kg,k=2,(2.04±0.18)mg/kg,k=2,respectively.The main factors that affect the uncertainty of determination results were standard substance,calibration curve,recovery and measurement repeatability. 展开更多
关键词 COSMETICS uncertainty inductively coupled plasma mass spectrometry(icp-ms) heavy metals
下载PDF
In vivo and in vitro inductively coupled plasma mass spectrometry quantification of minerals and heavy metals in Qishiwei Zhenzhu pill and their effect on intestinal flora
15
作者 FU Ke ZHANG De-wei +9 位作者 SONG Ying-lian XU Min WU Rui-xia XIONG Xue-qing LIU Xian-wu WU Lei GUO Ya ZHOU You LI Xiao-li WANG Zhang 《中国药理学与毒理学杂志》 CAS 北大核心 2021年第10期762-763,共2页
OBJECTIVE Cerebral ischemia or ischemic stroke is due to insufficient blood supply to the brain,which causes hypoxia or ischemia in some areas.This work aimed to quantify the minerals and heavy metals in Qishiwei Zhen... OBJECTIVE Cerebral ischemia or ischemic stroke is due to insufficient blood supply to the brain,which causes hypoxia or ischemia in some areas.This work aimed to quantify the minerals and heavy metals in Qishiwei Zhenzhu pill in vivo and in vitro,analyze its effect on the types and abundance of intestinal flora,and study its mechanism on inflammation and apoptosis pathways as a treatment for cerebral ischemia.METHODS Microwave digestion and inductively coupled plasma mass spectrometry(ICP-MS)were used to determine the minerals and heavy metals in 10 batches of Qishiwei Zhenzhu pill in vitro.With the use of the middle cerebral artery obstruction(MCAO)model,ICP-MS was applied to determine the content of minerals and heavy metals in hepatic portal vein blood,abdominal aortic blood,brain,liver,kidney,hair,urine and feces at different time periods.On this model,the ileum,cecum,and colon tissues were tested for intestinal pathology,and 16S rRNA was used for sequencing.Species taxonomy,αdiversity,and species microbial composition and structure analysis were also performed.Polymerase chain reaction and Western blotting were employed to determine the mRNA and protein expression of p38 MAPK,caspase-3,IL^(-1)βand TNF-αin the ischemic brain tissues of rats.RESULTS The average content of heavy metals in the 10 batches of Qishiwei Zhenzhu pill samples is in the descending order Hg>Cu>Pb.Significant differences in the metal elements are found among Qishiwei Zhenzhu pill from different manufacturers but not among the different batches of the same manufacturer.An extremely low content of heavy metals are absorbed into the blood or accumulated in the brain,liver,kidney,and other tissues.Stool is the main excretion route of minerals and heavy metals from Qishiwei Zhenzhu pill.This medicine helps repair the intestinal mucosa in MCAO rats.At the phylum level,it can regulate the abundance of Firmicutes and Proteobacteria in the intestinal flora of rats with cerebral ischemia.At the genus level,it can adjust the abundance of Escherichia Shigella.At the species level,it can adjust the abundance of Lactobacillus yoelii and Lactobacillus reuteri.Cluster classification results show that Qishiwei Zhenzhu pill can improve the intestinal flora of rats with cerebral ischemia,reduce the mRNA and protein expression of caspase-3 and IL^(-1)βin rat brain tissues,and have a tendency to decrease the mRNA expression of p38 MAPK and TNF-α.CONCLUSION Quantifying the minerals and heavy metals in Qishiwei Zhenzhu pill in vivo and in vitro will help improve their quality standards.Minerals and heavy metals are mainly excreted in feces,accumulate in extremely low levels in various tissues,and do not damage the intestinal mucosa.The effective material basis of Qishiwei Zhenzhu pill in treating cerebral ischemia may be related to their Li,Cr,and Cd elements.These pills can improve the environment of intestinal flora,and their mechanism of treatment for cerebral ischemia may be related to the down-regulation of IL^(-1)βinflammatory factor and inhibition of cell apoptosis. 展开更多
关键词 Qishiwei Zhenzhu pill cerebral ischemia inductively coupled plasma mass spectrometry minerals heavy metals intestinal flora
下载PDF
Measurement of the Trace Elements Cu, Zn, Fe, and Mg and the Ultratrace Elements Cd, Co, Mn, and Pb in Limited Quantity Human Plasma and Serum Samples by Inductively Coupled Plasma-Mass Spectrometry
16
作者 Gang Li John D. Brockman +2 位作者 Shih-Wen Lin Lance A. Schell J. David Robertson 《American Journal of Analytical Chemistry》 2012年第9期646-650,共5页
In public health studies limited volumes of blood are often collected and stored for future hypothesis testing. Archived samples are irreplaceable and therefore it is valuable to develop analytical techniques that req... In public health studies limited volumes of blood are often collected and stored for future hypothesis testing. Archived samples are irreplaceable and therefore it is valuable to develop analytical techniques that require minimal sample vo-lume. This work describes the measurement of trace elements Mg, Cu, Fe, Zn and ultratrace elements Cd, Co, Mn, Pb in limited quantity (150 μL) human serum or plasma samples. Samples were digested using a hotblock and analyzed using inductively coupled plasma mass spectrometry (ICP-MS). The analytical method was evaluated using a quadrupole (Q) and sector field high resolution (SF) instrument to analyze trace elements in Seronorm? quality control serum material. The method was used to analyze 1888 blinded human plasma samples which were archived for the National Cancer Institute from the Nutrition Intervention Trial in Linxian China. The inductively coupled plasma method was capable of accurately analyzed limited quantity samples of human serum and plasma for the trace elements Mg, Cu, Fe Zn and the ultra trace elements Co, Mn and Pb. The concentration of Cd in human plasma samples was below the level of detection for 75% of the samples analyzed. 展开更多
关键词 inductively coupled plasma mass SPECTROMETRY TRACE Element Measurements Human plasma SERUM
下载PDF
Simulated and Experimental Study of Single Particle Measurement Using Inductively Coupled Plasma Mass Spectrometry
17
作者 Zishan Gong Yan Wang +3 位作者 Ru Yang Yu Yang Xuehui Jiang Chuanqiang Sun 《Journal of Applied Mathematics and Physics》 2019年第11期2723-2737,共15页
A droplet carrying particle is desolvation, vaporization, ionization, and diffusion in an inductively coupled plasma (ICP) to form a cloud of ions. It then is detected as a mass-spectrum peak of individual particle. T... A droplet carrying particle is desolvation, vaporization, ionization, and diffusion in an inductively coupled plasma (ICP) to form a cloud of ions. It then is detected as a mass-spectrum peak of individual particle. The diameter of the particle is derived from its mass, which is calibrated using the peak area. This is the basic principle of measuring single particles using inductively coupled plasma mass spectrometry (ICP-MS). In this paper, a mathematical model describing single particles in plasma is investigated. This makes it possible to investigate the process and contributing factors of single particles measurement by ICP-MS. A series of processes are investigated, which include increasing the droplet temperature to the boiling point, desolvation of the droplets, increasing the particle temperature to the melting point, the particles are melted from a solid to the liquid, increasing the particle temperature to the boiling point, and particle vaporization. The simulation shows that both the atomic (ion) diffusion in the plasma and the incomplete vaporization of the particles are two important factors that limit the signal intensity of the particle’s mass spectrum. The experiment reveals that ICP-MS is very linear for Ag nanoparticles below 100 nm and SiO2 particles below 1000 nm. Both the simulation and experiment reveal the measurement deviation for large particles and that an increase of sampling depth can extend the diffusion time and cause signal suppression. The model can be used to study the mechanisms of monodispersed droplet or single-particle mass spectrometry, analyze the contributing parameters for single particle measurements by ICP-MS and provide a theoretical base for the optimization of single particle measurements in the practical application, such as nanoparticle devices, magnetic materials, biomedical materials additives and consumer products. 展开更多
关键词 Single PARTICLE inductively coupled plasma mass SPECTROMETRY MATHEMATICAL Model SAMPLE DEPTH
下载PDF
Effect of Sample Matrix on Radial and Axial Profiles of Ion Abundance in Inductively Coupled Plasma Mass Spectrometry
18
作者 Clarisse Mariet Francine Carrot Mélanie Moskura 《American Journal of Analytical Chemistry》 2011年第7期739-751,共13页
In inductively coupled plasma mass spectrometry (ICP-MS) analysis, only a few options are available to deal with non-spectroscopic interferences. Considering that diluting the sample is impractical for traces analysis... In inductively coupled plasma mass spectrometry (ICP-MS) analysis, only a few options are available to deal with non-spectroscopic interferences. Considering that diluting the sample is impractical for traces analysis, other alternatives must be employed. Traditionally, the method of standard additions is used to correct the matrix effect but it is a time consuming method. Others methods involves separation techniques. Another way to overcome matrix interferences is to understand the mechanism involved and adjust plasma viewing conditions to reduce or eliminate the effect. In this study, the effect of various concomitant elements in ICP-MS was assessed by measuring the distribution of selected singly charged analyte ions (Al, V, Cr, Mn, Ni, Co, Cu, Zn, As, In, Ba, La, Ce, Pb), doubly charged ions (La, Ce, Ba and Pb) and oxides ions (BaO) in the presence of concomitant elements spanning a mass range from 23 (Na) to 133 (Cs) u.m.a. and different ionization energies. Concomitant elements are alkali metals, alkaline earth metals and Si. Analyte ion suppression was observed while moving the ICP across and away from the sampling interface with or without a single concomitant element. Matrix effect measures were realised, firstly, to highlight the relation between the signal extinction of an analyte and the masse of the concomitant element, and secondly to highlight the relation between the removal of the analyte signal and the first ionization energy of the element of matrix. A dependence upon both the mass of the matrix element and the mass of the analyte was observed. The suppression seems increased with increasing matrix element mass and decreased with increasing analyte mass. The effect of the mass of the matrix element was the more significant of the two factors. If space-charge effects were found to be significant for matrix elements of much lower mass, it seems diffusion also played an active part for heavier matrix elements. Finally, some evidence was found for a shift in ion-atom equilibrium for dications and for energy demand regarding oxides. 展开更多
关键词 MATRIX Effects Easily Ionized Elements inductively coupled plasma mass SPECTROMETRY Spatial PROFILING
下载PDF
Diagnostics of Argon Inductively Coupled Plasma and Dielectric Barrier Discharge Plasma by Optical Emission Spectroscopy
19
作者 张家良 俞世吉 +1 位作者 马滕才 邓新绿 《Plasma Science and Technology》 SCIE EI CAS CSCD 2001年第4期883-890,共8页
An experimental setup was built up to carry out radio frequency (RF) inductively coupled plasma (ICP) and dielectric barrier discharge (DBD), and to depict the optical emission spectra (OES) of the discharges. OES fro... An experimental setup was built up to carry out radio frequency (RF) inductively coupled plasma (ICP) and dielectric barrier discharge (DBD), and to depict the optical emission spectra (OES) of the discharges. OES from argon ICP and DBD plasmas in visible and near ultraviolet region were measured. For argon ICP, the higher RF power input (higher than 500 W for our machine), the higher degree of argon plasma ionization. But that doesn't mean a higher mean electron energy. With the increase in the power input, the mean electron energy increases slightly, whereas the density of electron increases apparently On the contrary, argon DBD discharge behaves in the manner of a pulsed DC discharge on optical emission spectroscopy and V-I characteristics. DBD current is composed of a series of pulses equally spaced in temporal domain. The Kinetics of DBD emission strength is mainly governed by the frequency of the current pulse. 展开更多
关键词 In ICP Diagnostics of Argon inductively coupled plasma and Dielectric Barrier Discharge plasma by Optical Emission spectroscopy
下载PDF
<i>In Situ</i>Analysis of Copper Alloys by Femtosecond Laser Ablation Inductively Coupled Plasma Mass Spectrometry: Constrains on Matrix Effects
20
作者 Germán Velásquez Anastassia Y. Borisova +1 位作者 Sandrine Baron Luc Robbiola 《American Journal of Analytical Chemistry》 2018年第3期150-161,共12页
Direct analysis of copper-base alloys using laser ablation techniques is an increasingly common procedure in cultural heritage studies. However, main discussions remain focused on the possibility of using non-matrix m... Direct analysis of copper-base alloys using laser ablation techniques is an increasingly common procedure in cultural heritage studies. However, main discussions remain focused on the possibility of using non-matrix matched external reference materials. To evaluate the occurrence of matrix effects during in situ microanalysis of copper-base materials, using near infrared femtosecond laser ablation techniques (NIR fs-LA-ICP-MS), two bronzes, i.e., (Sn-Zn)-ternary and (Sn)-binary copper-matrix reference materials, as well as a reference synthetic glass (NIST-SRM-610) have been analyzed. The results have been compared to data obtained on a sulfide-matrix reference material. Similar values in relative sensitivity averages of 63Cu, 118Sn and 66Zn, as well as in 118Sn/63Cu and 66Zn/63Cu ratios were obtained, for all analyzed matrix types, i.e., copper-base-, silicate-, and sulfide-reference materials. Consequently, it is possible to determinate major and minor element concentrations in copper alloys, i.e., Cu, Sn and Zn, using silicate and sulfide reference materials as external calibrators, without any matrix effect and over a wide range of concentrations (from wt.% to ppm). Equally, Cu, Sn and Zn concentrations can be precisely determined in sulfides using homogeneous alloys (reference) materials as an external calibrator. Thus, it is possible to determine Cu, Sn and Zn in copper-base materials and their ore minerals, mostly sulfides, in a single analytical session, without requiring specific external calibrators for each matrix type. In contrast, immiscible elements in copper matrix, such as Pb and Fe show notable differences in their relative sensitivity values and ratios for different matrix-materials analyzed, implying that matrix-matched external calibrations remain to be applied for their trace quantification. 展开更多
关键词 Copper Alloys Reference Material Matrix Effect In-Situ Metal Determinations NEAR-INFRARED Femtosecond Laser Ablation-inductively coupled plasma-mass SPECTROMETRY (NIR fs-LA-icp-ms)
下载PDF
上一页 1 2 231 下一页 到第
使用帮助 返回顶部