Biomass is considered a renewable and cleaner energy source alternative to fossil fuels.In recent years,industrial biomass boilers have been rapidly developed and widely used in the industrial field.This work makes a ...Biomass is considered a renewable and cleaner energy source alternative to fossil fuels.In recent years,industrial biomass boilers have been rapidly developed and widely used in the industrial field.This work makes a review on the fuel types used in industrial biomass boilers,the fuel characteristics and the characteristics of air pollutants emitted from the combustion of industrial biomass boilers and other contents in different studies.However,the existing research still has many deficiencies.In the future,further research on biomass fuel,industrial biomass boiler combustion process and the pollutants emitted by industrial biomass boiler combustion,especially the carbonaceous aerosol emitted by in-dustrial biomass boiler and carbonaceous aerosol optical properties still need to be made.At the same time,the potential harm of carbonaceous aerosols emitted from industrial biomass boiler sources to human health and climate change needs to be studied in depth.This review provides a scientific basis for the accurate evaluation of industrial biomass boilers and the effective prevention and control of various pollutants of industrial biomass boilers.展开更多
In a gas/particle two-phase test facility, a three-component particle-dynamics anemometer was used to measure the characteristics of gas/particle two-phase flows in a 29 megawatt (MW) pulverized coal industrial boiler...In a gas/particle two-phase test facility, a three-component particle-dynamics anemometer was used to measure the characteristics of gas/particle two-phase flows in a 29 megawatt (MW) pulverized coal industrial boiler equipped with a new type of swirling pulverized coal burner. The distributions of three-dimensional gas/particle velocity, particle volume flux, and particle size distribution were measured under different working conditions. The mean axial velocity and the particle volume flux in the central region of the burner outlet were found to be negative. This indicated that a central recirculation zone was formed in the center of the burner. In the central recirculation zone, the absolute value of the mean axial velocity and the particle volume flux increased when the external secondary air volume increased. The size of the central reflux zone remained stable when the air volume ratio changed. Along the direction of the jet, the peak value formed by the tertiary air gradually moved toward the center of the burner. This tertiary air was mixed with the peak value formed by the air in the adiabatic combustion chamber after the cross-section of x/d = 0.7. Large particles were concentrated near the wall area, and the particle size in the recirculation zone was small.展开更多
基金supported by the National Natural Science Foundation of China(grant Nos.42265011,41765009,and 52064037)the Training Program for Academic and Technical Leaders of Major Disciplines in Jiangxi Province,China(grant No.20212BCJL23054)。
文摘Biomass is considered a renewable and cleaner energy source alternative to fossil fuels.In recent years,industrial biomass boilers have been rapidly developed and widely used in the industrial field.This work makes a review on the fuel types used in industrial biomass boilers,the fuel characteristics and the characteristics of air pollutants emitted from the combustion of industrial biomass boilers and other contents in different studies.However,the existing research still has many deficiencies.In the future,further research on biomass fuel,industrial biomass boiler combustion process and the pollutants emitted by industrial biomass boiler combustion,especially the carbonaceous aerosol emitted by in-dustrial biomass boiler and carbonaceous aerosol optical properties still need to be made.At the same time,the potential harm of carbonaceous aerosols emitted from industrial biomass boiler sources to human health and climate change needs to be studied in depth.This review provides a scientific basis for the accurate evaluation of industrial biomass boilers and the effective prevention and control of various pollutants of industrial biomass boilers.
基金This work was supported by National Key Research and Development Program of China(Grant No.2017YF C0212500).
文摘In a gas/particle two-phase test facility, a three-component particle-dynamics anemometer was used to measure the characteristics of gas/particle two-phase flows in a 29 megawatt (MW) pulverized coal industrial boiler equipped with a new type of swirling pulverized coal burner. The distributions of three-dimensional gas/particle velocity, particle volume flux, and particle size distribution were measured under different working conditions. The mean axial velocity and the particle volume flux in the central region of the burner outlet were found to be negative. This indicated that a central recirculation zone was formed in the center of the burner. In the central recirculation zone, the absolute value of the mean axial velocity and the particle volume flux increased when the external secondary air volume increased. The size of the central reflux zone remained stable when the air volume ratio changed. Along the direction of the jet, the peak value formed by the tertiary air gradually moved toward the center of the burner. This tertiary air was mixed with the peak value formed by the air in the adiabatic combustion chamber after the cross-section of x/d = 0.7. Large particles were concentrated near the wall area, and the particle size in the recirculation zone was small.