英国早产儿视网膜病变的筛查和治疗指南2022更新版由英国皇家儿科与儿童健康学院和皇家眼科学院的多学科指南制订小组按照英国国家卫生与临床优化研究所标准制订,于2022年3月发表在英国皇家儿科与儿童健康学院网站和皇家眼科学院网站,2...英国早产儿视网膜病变的筛查和治疗指南2022更新版由英国皇家儿科与儿童健康学院和皇家眼科学院的多学科指南制订小组按照英国国家卫生与临床优化研究所标准制订,于2022年3月发表在英国皇家儿科与儿童健康学院网站和皇家眼科学院网站,2023年3月在Early Human Development杂志正式发表。该指南对早产儿视网膜病变的筛查及治疗进行了循证推荐和建议。与更新前的指南相比,2022更新版最重要的变化是将胎龄筛查标准降至31周以下;治疗部分涵盖了早产儿视网膜病变的治疗适应证、时间、方法及随诊。该文对该指南进行解读并与国内早产儿视网膜病变指南/共识进行比较,为国内同行提供参考和借鉴。展开更多
Background: Early and non-invasive diagnosis of neonatal hyperbilirubinemia remains critical in dark skinned babies of low resource settings. Objective: To assess correlation/agreement between transcutaneous bilirubin...Background: Early and non-invasive diagnosis of neonatal hyperbilirubinemia remains critical in dark skinned babies of low resource settings. Objective: To assess correlation/agreement between transcutaneous bilirubin (Tcb) and serum bilirubin (Tsb) values in full term neonates with jaundice. Methodology: An analytical cross-sectional study was conducted at the neonatology unit of the Essos Hospital Centre (EHC) from January to June 2019. All full-term neonates aged 0 to 7 days with suspected jaundice who did not receive phototherapy were eligible for the study. The enrolled neonates in the study were assessed clinically, then with the MBJ20 transcutaneous bilirubinometer (TcB). The MBJ20 transcutaneous bilirubinometer highest measurement over the forehead and the sternum were compared to TsB. Data were entered and then analysed with the CsPro7.2 and R (version 3.6.0) software. Correlation was captured by Bland & Alman plots and Concordance Correlation Coefficient (CCC) estimates. The Pearson correlation coefficient and Student test for paired data were used for descriptions purposes, and the significance level was 5%. Results: We recruited 88 neonates. The sex ratio of the babies included was 1.25 favouring males. Median Post-natal age was 3 days with 62% aged 72 hours or more. The mean TcB corresponding to the maximum average between frontal and sternal measurement was 153 mg/dl ± 48 and the average Tsb was 123.80 mg/dl ± 50.48. A good linear correlation was found between TcB and total serum bilirubin level r = 0.86 [0.80;0.91]. Positive correlation was noted between both (forehead and sternum) TcB measurements sites, namely r = 0.78 and r = 0.86. The Bland & Altman plot measured the bias at -29.68 mg/l (confidence interval at 95%, 21.14 - 80.50). The CCC estimate was 0.2 varying from -0.22 to 0.76 according to TcB measurement threshold and post-natal age. The ROC area under the curve value for a threshold < 100 mg/l equals 90% proving to be a good predictor for this threshold. Conclusion: A good linear correlation was found despite a poor agreement between TcB and Tsb. TcB method systematically overestimated the value of TsB.展开更多
文摘英国早产儿视网膜病变的筛查和治疗指南2022更新版由英国皇家儿科与儿童健康学院和皇家眼科学院的多学科指南制订小组按照英国国家卫生与临床优化研究所标准制订,于2022年3月发表在英国皇家儿科与儿童健康学院网站和皇家眼科学院网站,2023年3月在Early Human Development杂志正式发表。该指南对早产儿视网膜病变的筛查及治疗进行了循证推荐和建议。与更新前的指南相比,2022更新版最重要的变化是将胎龄筛查标准降至31周以下;治疗部分涵盖了早产儿视网膜病变的治疗适应证、时间、方法及随诊。该文对该指南进行解读并与国内早产儿视网膜病变指南/共识进行比较,为国内同行提供参考和借鉴。
文摘Background: Early and non-invasive diagnosis of neonatal hyperbilirubinemia remains critical in dark skinned babies of low resource settings. Objective: To assess correlation/agreement between transcutaneous bilirubin (Tcb) and serum bilirubin (Tsb) values in full term neonates with jaundice. Methodology: An analytical cross-sectional study was conducted at the neonatology unit of the Essos Hospital Centre (EHC) from January to June 2019. All full-term neonates aged 0 to 7 days with suspected jaundice who did not receive phototherapy were eligible for the study. The enrolled neonates in the study were assessed clinically, then with the MBJ20 transcutaneous bilirubinometer (TcB). The MBJ20 transcutaneous bilirubinometer highest measurement over the forehead and the sternum were compared to TsB. Data were entered and then analysed with the CsPro7.2 and R (version 3.6.0) software. Correlation was captured by Bland & Alman plots and Concordance Correlation Coefficient (CCC) estimates. The Pearson correlation coefficient and Student test for paired data were used for descriptions purposes, and the significance level was 5%. Results: We recruited 88 neonates. The sex ratio of the babies included was 1.25 favouring males. Median Post-natal age was 3 days with 62% aged 72 hours or more. The mean TcB corresponding to the maximum average between frontal and sternal measurement was 153 mg/dl ± 48 and the average Tsb was 123.80 mg/dl ± 50.48. A good linear correlation was found between TcB and total serum bilirubin level r = 0.86 [0.80;0.91]. Positive correlation was noted between both (forehead and sternum) TcB measurements sites, namely r = 0.78 and r = 0.86. The Bland & Altman plot measured the bias at -29.68 mg/l (confidence interval at 95%, 21.14 - 80.50). The CCC estimate was 0.2 varying from -0.22 to 0.76 according to TcB measurement threshold and post-natal age. The ROC area under the curve value for a threshold < 100 mg/l equals 90% proving to be a good predictor for this threshold. Conclusion: A good linear correlation was found despite a poor agreement between TcB and Tsb. TcB method systematically overestimated the value of TsB.