The development of components of VEP was studied in 150 infants and children between 2 weeks and 9 years of age participated as subjects. Ten adult subjects, 25 ito 35 years of age were also studied. The results indic...The development of components of VEP was studied in 150 infants and children between 2 weeks and 9 years of age participated as subjects. Ten adult subjects, 25 ito 35 years of age were also studied. The results indicated that the VEP had a simple wave form, consisting of only a slowly rising positive wave to 140', 70' and 35' checks from infants of 2 to 8 weeks following birth. P_1 wave appeared in response to 17.5' check stimulus at 10 weeks following birth. The latencies of P_1 components shortened d...展开更多
In order to allow the guardians to monitor the physiological parameters of the infant more intuitively and to be able to respond to sudden irregularities in the pulse rate,abnormal blood oxygen,high or low body temper...In order to allow the guardians to monitor the physiological parameters of the infant more intuitively and to be able to respond to sudden irregularities in the pulse rate,abnormal blood oxygen,high or low body temperature and other conditions,and to facilitate communication with the medical staff or to request assistance in treatment,an STM32 microcontroller-based infant health monitoring system is designed.The digital signal acquisition module for pulse,blood oxygen and body temperature acquire the raw data,and the microcontroller performs algorithmic processing to display the physiological parameters such as pulse,blood oxygen and body temperature of the infant,and configures the threshold alarms for the physiological parameters by means of a keypad module.Finally,the test results are compared and tested against the standard physiological parameters of infants and children to verify that the system meets the requirements of medical precision and accuracy.展开更多
文摘The development of components of VEP was studied in 150 infants and children between 2 weeks and 9 years of age participated as subjects. Ten adult subjects, 25 ito 35 years of age were also studied. The results indicated that the VEP had a simple wave form, consisting of only a slowly rising positive wave to 140', 70' and 35' checks from infants of 2 to 8 weeks following birth. P_1 wave appeared in response to 17.5' check stimulus at 10 weeks following birth. The latencies of P_1 components shortened d...
文摘In order to allow the guardians to monitor the physiological parameters of the infant more intuitively and to be able to respond to sudden irregularities in the pulse rate,abnormal blood oxygen,high or low body temperature and other conditions,and to facilitate communication with the medical staff or to request assistance in treatment,an STM32 microcontroller-based infant health monitoring system is designed.The digital signal acquisition module for pulse,blood oxygen and body temperature acquire the raw data,and the microcontroller performs algorithmic processing to display the physiological parameters such as pulse,blood oxygen and body temperature of the infant,and configures the threshold alarms for the physiological parameters by means of a keypad module.Finally,the test results are compared and tested against the standard physiological parameters of infants and children to verify that the system meets the requirements of medical precision and accuracy.