A radiant source with a large aperture at 5--95℃ in the wavelength bands of 8--12μm for calibrating infrared imaging systems has been designed. The effective emissivity of its flat bottom with concentric V-grooves w...A radiant source with a large aperture at 5--95℃ in the wavelength bands of 8--12μm for calibrating infrared imaging systems has been designed. The effective emissivity of its flat bottom with concentric V-grooves was evaluated by the Monte-Carlo method whose correctness was tested and accuracy was discussed. The structure of the source was completed by incorporating the simulation results with the blackbody cavity effect. The source was certificated via an optical measurement system. The source can provide a consistent radiant flux with temperature uniformity of ±0.1℃ over an area of diameter of φ80 mm.展开更多
The calibration accuracy of High Resolution Infrared Radiation Sounder Mod. 2 (HIRS / 2) on NOAA-10 satellite is analyzed in this paper. The non-linear effect in the linear calibration curve induces a deviation of 1.5...The calibration accuracy of High Resolution Infrared Radiation Sounder Mod. 2 (HIRS / 2) on NOAA-10 satellite is analyzed in this paper. The non-linear effect in the linear calibration curve induces a deviation of 1.5 degrees (k) of brightness temperature in the tenth channel (8.3 um, water vapor absorption) of the HIRS/2 and the non-linear effect affects the other channels to a different extent. Based on analyzing non- linearity in two-point calibration curve, a tri-point calibration equation is given. A numerical test of effects of the linear and non-linear calibration models on the accuracy of atmospheric temperature retrievals is carried out.展开更多
基金This work was supported by the National Natural Science Foundation of China under Grant No. 50336010.
文摘A radiant source with a large aperture at 5--95℃ in the wavelength bands of 8--12μm for calibrating infrared imaging systems has been designed. The effective emissivity of its flat bottom with concentric V-grooves was evaluated by the Monte-Carlo method whose correctness was tested and accuracy was discussed. The structure of the source was completed by incorporating the simulation results with the blackbody cavity effect. The source was certificated via an optical measurement system. The source can provide a consistent radiant flux with temperature uniformity of ±0.1℃ over an area of diameter of φ80 mm.
文摘The calibration accuracy of High Resolution Infrared Radiation Sounder Mod. 2 (HIRS / 2) on NOAA-10 satellite is analyzed in this paper. The non-linear effect in the linear calibration curve induces a deviation of 1.5 degrees (k) of brightness temperature in the tenth channel (8.3 um, water vapor absorption) of the HIRS/2 and the non-linear effect affects the other channels to a different extent. Based on analyzing non- linearity in two-point calibration curve, a tri-point calibration equation is given. A numerical test of effects of the linear and non-linear calibration models on the accuracy of atmospheric temperature retrievals is carried out.