The process of development and calibration for the first Moon-based ex- treme ultraviolet (EUV) camera to observe Earth's plasmasphere is introduced and the design, test and calibration results are presented. The E...The process of development and calibration for the first Moon-based ex- treme ultraviolet (EUV) camera to observe Earth's plasmasphere is introduced and the design, test and calibration results are presented. The EUV camera is composed of a multilayer film mirror, a thin film filter, a photon-counting imaging detector, a mech- anism that can adjust the direction in two dimensions, a protective cover, an electronic unit and a thermal control unit. The center wavelength of the EUV camera is 30.2 nm with a bandwidth of 4.6nm. The field of view is 14.7° with an angular resolution of 0.08°, and the sensitivity of the camera is 0.11 count s-1 Rayleigh-1. The geomet- ric calibration, the absolute photometric calibration and the relative photometric cal- ibration are carried out under different temperatures before launch to obtain a matrix that can correct geometric distortion and a matrix for relative photometric correction, which are used for in-orbit correction of the images to ensure their accuracy.展开更多
Inadequate geometric accuracy of cameras is the main constraint to improving the precision of infrared horizon sensors with a large field of view(FOV).An enormous FOV with a blind area in the center greatly limits the...Inadequate geometric accuracy of cameras is the main constraint to improving the precision of infrared horizon sensors with a large field of view(FOV).An enormous FOV with a blind area in the center greatly limits the accuracy and feasibility of traditional geometric calibration methods.A novel camera calibration method for infrared horizon sensors is presented and validated in this paper.Three infrared targets are used as control points.The camera is mounted on a rotary table.As the table rotates,these control points will be evenly distributed in the entire FOV.Compared with traditional methods that combine a collimator and a rotary table which cannot effectively cover a large FOV and require harsh experimental equipment,this method is easier to implement at a low cost.A corresponding three-step parameter estimation algorithm is proposed to avoid precisely measuring the positions of the camera and the control points.Experiments are implemented with 10 infrared horizon sensors to verify the effectiveness of the calibration method.The results show that the proposed method is highly stable,and that the calibration accuracy is at least 30%higher than those of existing methods.展开更多
文摘The process of development and calibration for the first Moon-based ex- treme ultraviolet (EUV) camera to observe Earth's plasmasphere is introduced and the design, test and calibration results are presented. The EUV camera is composed of a multilayer film mirror, a thin film filter, a photon-counting imaging detector, a mech- anism that can adjust the direction in two dimensions, a protective cover, an electronic unit and a thermal control unit. The center wavelength of the EUV camera is 30.2 nm with a bandwidth of 4.6nm. The field of view is 14.7° with an angular resolution of 0.08°, and the sensitivity of the camera is 0.11 count s-1 Rayleigh-1. The geomet- ric calibration, the absolute photometric calibration and the relative photometric cal- ibration are carried out under different temperatures before launch to obtain a matrix that can correct geometric distortion and a matrix for relative photometric correction, which are used for in-orbit correction of the images to ensure their accuracy.
文摘Inadequate geometric accuracy of cameras is the main constraint to improving the precision of infrared horizon sensors with a large field of view(FOV).An enormous FOV with a blind area in the center greatly limits the accuracy and feasibility of traditional geometric calibration methods.A novel camera calibration method for infrared horizon sensors is presented and validated in this paper.Three infrared targets are used as control points.The camera is mounted on a rotary table.As the table rotates,these control points will be evenly distributed in the entire FOV.Compared with traditional methods that combine a collimator and a rotary table which cannot effectively cover a large FOV and require harsh experimental equipment,this method is easier to implement at a low cost.A corresponding three-step parameter estimation algorithm is proposed to avoid precisely measuring the positions of the camera and the control points.Experiments are implemented with 10 infrared horizon sensors to verify the effectiveness of the calibration method.The results show that the proposed method is highly stable,and that the calibration accuracy is at least 30%higher than those of existing methods.