期刊文献+
共找到7篇文章
< 1 >
每页显示 20 50 100
Investigation on the plastic work-heat conversion coefficient of 7075-T651 aluminum alloy during an impact process based on infrared temperature measurement technology 被引量:3
1
作者 Tong Zhang Ze-Rong Guo +1 位作者 Fu-Ping Yuan Hu-Sheng Zhang 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2018年第2期327-333,共7页
The plastic work-heat conversion coefficient is one key parameter for studying the work-heat conversion under dynamic deformation of materials. To explore this coefficient of 7075-T651 aluminum alloy under dynamic com... The plastic work-heat conversion coefficient is one key parameter for studying the work-heat conversion under dynamic deformation of materials. To explore this coefficient of 7075-T651 aluminum alloy under dynamic compression, dynamic compression experiments using the Hopkinson bar under four groups of strain rates were conducted, and the temperature signals were measured by constructing a transient infrared temperature measurement system. According to stress versus strain data as well as the corresponding temperature data obtained through the experiments, the influences of the strain and the strain rate on the coefficient of plastic work converted to heat were analyzed.The experimental results show that the coefficient of plastic work converted to heat of 7075-T651 aluminum alloy is not a constant at the range of 0.85–1 and is closely related to the strain and the strain rate. The change of internal structure of material under high strain rate reduces its energy storage capacity, and makes almost all plastic work convert into heat. 展开更多
关键词 Plastic work-heat conversion coefficient infrared temperature measurement Dynamic compression 7075-T651 Aluminum alloy
下载PDF
The Study of In-Orbit Calibration Accuracy of NOAA Satellite Infrared Sounder and Its Effect on Temperature Profile Retrievals 被引量:1
2
作者 董超华 刘全华 +1 位作者 黎光清 张凤英 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 1990年第2期211-219,共9页
The calibration accuracy of High Resolution Infrared Radiation Sounder Mod. 2 (HIRS / 2) on NOAA-10 satellite is analyzed in this paper. The non-linear effect in the linear calibration curve induces a deviation of 1.5... The calibration accuracy of High Resolution Infrared Radiation Sounder Mod. 2 (HIRS / 2) on NOAA-10 satellite is analyzed in this paper. The non-linear effect in the linear calibration curve induces a deviation of 1.5 degrees (k) of brightness temperature in the tenth channel (8.3 um, water vapor absorption) of the HIRS/2 and the non-linear effect affects the other channels to a different extent. Based on analyzing non- linearity in two-point calibration curve, a tri-point calibration equation is given. A numerical test of effects of the linear and non-linear calibration models on the accuracy of atmospheric temperature retrievals is carried out. 展开更多
关键词 In The Study of In-Orbit Calibration Accuracy of NOAA Satellite infrared Sounder and Its Effect on temperature Profile Retrievals NOAA CLI
下载PDF
Experimental study on the infrared precursor characteristics of gas-bearing coal failure under loading 被引量:4
3
作者 Shan Yin Zhonghui Li +4 位作者 Dazhao Song Xueqiu He Liming Qiu Quan Lou He Tian 《International Journal of Mining Science and Technology》 SCIE EI CAS CSCD 2021年第5期901-912,共12页
The stress and gas pressure in deep coal seams are very high,and instability and failure rapidly and intensely occur.It is important to study the infrared precursor characteristics of gas-bearing coal instability and ... The stress and gas pressure in deep coal seams are very high,and instability and failure rapidly and intensely occur.It is important to study the infrared precursor characteristics of gas-bearing coal instability and failure.In this paper,a self-developed stress-gas coupling failure infrared experimental system was used to analyse the infrared radiation temperature(IRT)and infrared thermal image precursor characteristics of gas-free coal and gas-bearing coal.The changes in the areas of the infrared temperature anomalous precursor regions and the effect of the gas on the infrared precursors were examined.The results show that high-temperature anomalous precursors arise mainly when the gas-free coal fails under loading,whereas the gas-bearing coal has high-temperature and low-temperature anomalous precursors.The area of the high-temperature anomalous precursor is approximately 30%–40%under gasbearing coal unstable failure,which is lower than the 60%–70%of the gas-free coal.The area of the low-temperature abnormal precursor is approximately 3%–6%,which is higher than the 1%–2%of the gas-free coal.With increasing gas pressure,the area of the high-temperature anomalous precursor gradually decreases,and the area of the low-temperature anomalous precursor gradually increases.The highand low-temperature anomalous precursors of gas-bearing coal are mainly caused by gas desorption,volume expansion,and thermal friction.The presence of gas inhibits the increase in IRT on the coal surface and increases the difficulty of infrared radiation(IR)monitoring and early warning for gas-bearing coal. 展开更多
关键词 Gas–bearing coal Gas pressure infrared temperature infrared thermal image infrared precursory law
下载PDF
Research on the Explosion Temperature Response of Fuel Air Explosive Measured by Colorimetric Pyrometer 被引量:1
4
作者 刘庆明 白春华 《Defence Technology(防务技术)》 SCIE EI CAS 2010年第1期59-64,共6页
An infrared colorimetric radiation thermometrical system was established based on the theory of optical radiation. The dynamic temperature history of fuel air explosive (FAE) was measured to obtain the temperature res... An infrared colorimetric radiation thermometrical system was established based on the theory of optical radiation. The dynamic temperature history of fuel air explosive (FAE) was measured to obtain the temperature responses of primary initiation FAE and secondary initiation FAE in real time. And the characteristics of their temperature history curves were compared and analyzed. The results show that the primary initiation FAE has higher explosion temperature and longer duration compared to the secondary initiation FAE. 展开更多
关键词 mechanics of explosion explosion temperature fuel air explosive radiation pyrometry colorimetric pyrometer infrared temperature measurement
下载PDF
REMOTE SENSING OF CLOUD BOTTOM HEIGHT AND CLOUD TEMPERATURE BY INFRARED RADIOMETER 被引量:1
5
作者 王普才 吕达仁 林海 《Acta meteorologica Sinica》 SCIE 1989年第1期54-63,共10页
The feasibility of retrieving cloud bottom height (CBH) and cloud bottom temperature (CBT) by infrared radiometer has been studied by simulations with a large number of historical radiosounding data and field obser- v... The feasibility of retrieving cloud bottom height (CBH) and cloud bottom temperature (CBT) by infrared radiometer has been studied by simulations with a large number of historical radiosounding data and field obser- vations.The results show that it is feasible to retrieve CBH and CBT by radiometer observation in infrared band. In this paper we also demonstrate simply that through joint observations by a dual-wavelength (1.35 cm and 8.5mm) microwave radiometer and by infrared radiometer (8.5—12.5μm),it is possible to obtain total water vapor,liquid water content in clouds and CBH and CBT. 展开更多
关键词 CBH REMOTE SENSING OF CLOUD BOTTOM HEIGHT AND CLOUD temperature BY infrared RADIOMETER
原文传递
Film Cooling Effectiveness Superposition Calculation of Double-Row Injection Holes on Turbine Vane 被引量:1
6
作者 XU Zhipeng ZHU Huiren +2 位作者 LIU Cunliang YE Lin ZHOU Daoen 《Journal of Thermal Science》 SCIE EI CAS CSCD 2022年第6期2424-2437,共14页
Film cooling effectiveness superposition of double-row injection holes on the turbine vane was studied by infrared temperature measurement experiment. The Sellers superposition method and a modified Sellers method wer... Film cooling effectiveness superposition of double-row injection holes on the turbine vane was studied by infrared temperature measurement experiment. The Sellers superposition method and a modified Sellers method were adopted for dustpan-shaped hole and cylindrical hole. Numerical simulations were implemented to analyze the film superposition mechanism. It is found that the Sellers method is more accurate on the suction side than the pressure side. Injection film of the two types of holes exhibits different superposition modes. Cylindrical hole are “blocky-like” superposition. Dustpan-shaped hole are “sheet-like” superposition. The counter-rotating vortex pairs and separation of the film are the main factors affecting the accuracy of Sellers film superposition method. The modified method can significantly improve the superposition prediction accuracy for almost all situations. The modified method reduces superposition errors from 28% to 3% for the cylindrical hole, and from 42% to 13% for the dustpan-shaped hole on the suction side. It reduces superposition errors from 30% to 8% for the cylindrical hole, and from 23% to 15% for the dustpan-shaped hole on the pressure side. 展开更多
关键词 film cooling superposition calculation shaped hole infrared temperature measurement numerical simulation
原文传递
Thermal analysis in high power GaAs-based laser diodes 被引量:3
7
作者 龚雪芹 冯士维 +2 位作者 岳元 杨军伟 李经纬 《Journal of Semiconductors》 EI CAS CSCD 2016年第4期88-92,共5页
The thermal characteristics of 808 nm Al Ga As/Ga As laser diodes(LDs) are analyzed via electrical transient measurements and infrared thermography. The temperature rise and thermal resistance are measured at variou... The thermal characteristics of 808 nm Al Ga As/Ga As laser diodes(LDs) are analyzed via electrical transient measurements and infrared thermography. The temperature rise and thermal resistance are measured at various input currents and powers. From the electrical transient measurements, it is found that there is a significant reduction in thermal resistance with increasing power because of the device power conversion efficiency. The component thermal resistance that was obtained from the structure function showed that the total thermal resistance is mainly composed of the thermal resistance of the sub-mount rather than that of the LD chip, and the thermal resistance of the sub-mount decreases with increasing current. The temperature rise values are also measured by infrared thermography and are calibrated based on a reference image, with results that are lower than those determined by electrical transient measurements. The difference in the results is caused by the limited spatial resolution of the measurements and by the signal being captured from the facet rather than from the junction of the laser diode. 展开更多
关键词 laser diodes temperature rise thermal resistance electrical transient measurement infrared thermography
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部