This paper shows the effect of excess air on combustion gas temperature at turbine inlet, and how it determines power and thermal efficiency of a gas turbine at different pressure ratios and excess air. In such a way ...This paper shows the effect of excess air on combustion gas temperature at turbine inlet, and how it determines power and thermal efficiency of a gas turbine at different pressure ratios and excess air. In such a way an analytic Equation that allows calculating the turbine inlet temperature as a function of excess air, pressure ratio and relative humidity is given. Humidity Impact on excess air calculation is also analyzed and presented. Likewise it is demonstrated that dry air calculations determine a higher level for calculations that can be performed on wet air.展开更多
The effects of supply temperature and vertical location of inlet air on particle dispersion in a displacement ventilated (DV) room were numerically modeled with validation by experimental data from the literature. T...The effects of supply temperature and vertical location of inlet air on particle dispersion in a displacement ventilated (DV) room were numerically modeled with validation by experimental data from the literature. The results indicate that the temperature and vertical location of inlet supply air did not greatly affect the air distribution in the upper parts of a DV room, but could significantly influence the airflow pattern in the lower parts of the room, thus affecting the indoor air quality with contaminant sources located at the lower level, such as particles from working activities in an office. The numerical results also show that the inlet location would slightly influence the relative ventilation efficiency for the same air supply volume, but particle concentration in the breathing zone would be slightly lower with a low horizontal wall slot than a rectangular diffuser. Comparison of the results for two different supply temperatures in a DV room shows that, although lower supply temperature means less incoming air volume, since the indoor flow is mainly driven by buoyancy, lower supply temperature air could more efficiently remove passive sources (such as particles released from work activities in an office). However, in the breathing zone it gives higher concentration as compared to higher supply air temperature. To obtain good indoor air quality, low supply air temperature should be avoided because concentration in the breathing zone has a stronger and more direct impact on human health.展开更多
A novel adjusting method for improving gas turbine(GT)efficiency and surge margin(SM)under partload conditions is proposed.This method adopts the inlet air heating technology,which uses the waste heat of lowgrade heat...A novel adjusting method for improving gas turbine(GT)efficiency and surge margin(SM)under partload conditions is proposed.This method adopts the inlet air heating technology,which uses the waste heat of lowgrade heat source and the inlet guide vane(IGV)opening adjustment.Moreover,the regulation rules of the compressor inlet air temperature and the IGV opening are studied comprehensively to optimize GT performance.A model and calculation method for an equilibrium running line is adopted based on the characteristic curves of the compressor and turbine.The equilibrium running lines calculated through the calculation method involve three part-load conditions and three IGVopenings with different inlet air temperatures.The results show that there is an optimal matching relationship between IGV opening and inlet air temperature.For the best GT performance of a given load,the IGV could be adjusted according to inlet air temperature.In addition,inlet air heating has a considerable potential for the improvement of part-load performance of GT due to the increase in compressor efficiency,combustion efficiency,and turbine efficiency as well as turbine inlet temperature,when inlet air temperature is lower than the optimal value with different IGV openings.Further,when the IGV is in a full opening state and an optimal inlet air temperature is achieved by using the inlet air heating technology,GT efficiency and SM can be obviously higher than other IGVopenings.The IGV can be left unadjusted,even when the load is as low as 50%.These findings indicate that inlet air heating has a great potential to replace the IGV to regulate load because GT efficiency and SM can be remarkably improved,which is different from the traditional viewpoints.展开更多
针对高马赫数高温条件下飞机进气道射流预冷问题,本文建立了真实飞机全尺寸进气道-射流预冷装置一体化数值计算模型,通过控制变量法分析了进气流量、进气温度及射流流量对射流预冷装置性能的影响规律,发现进气流量与降温量呈负相关,与...针对高马赫数高温条件下飞机进气道射流预冷问题,本文建立了真实飞机全尺寸进气道-射流预冷装置一体化数值计算模型,通过控制变量法分析了进气流量、进气温度及射流流量对射流预冷装置性能的影响规律,发现进气流量与降温量呈负相关,与蒸发效率和温场均匀性呈正相关;进气温度与降温量、蒸发效率及温场均匀性均呈正相关;射流流量与降温量呈正相关,与蒸发效率及温场均匀性呈负相关。研究结果表明,在相同进气状态下,此飞机进气道的特殊构型会导致降温量和蒸发效率曲线在蒸发距离为2500mm处存在拐点。在此基础上,进一步提出了一种基于试验设计法(Design of experiment,DOE)评估进气道出口总温的评估方法,与试验结果对比发现该方法可将误差控制在5%以内。因此,采用该方法进行进气道出口总温预估是有效的。展开更多
文摘This paper shows the effect of excess air on combustion gas temperature at turbine inlet, and how it determines power and thermal efficiency of a gas turbine at different pressure ratios and excess air. In such a way an analytic Equation that allows calculating the turbine inlet temperature as a function of excess air, pressure ratio and relative humidity is given. Humidity Impact on excess air calculation is also analyzed and presented. Likewise it is demonstrated that dry air calculations determine a higher level for calculations that can be performed on wet air.
基金supported by the National Natural Science Foundation of China (Grant No. 40975093)Shanghai Educational Development Foundation titled "Shuguang Project", P.R. China(Grant No. 03SG30)
文摘The effects of supply temperature and vertical location of inlet air on particle dispersion in a displacement ventilated (DV) room were numerically modeled with validation by experimental data from the literature. The results indicate that the temperature and vertical location of inlet supply air did not greatly affect the air distribution in the upper parts of a DV room, but could significantly influence the airflow pattern in the lower parts of the room, thus affecting the indoor air quality with contaminant sources located at the lower level, such as particles from working activities in an office. The numerical results also show that the inlet location would slightly influence the relative ventilation efficiency for the same air supply volume, but particle concentration in the breathing zone would be slightly lower with a low horizontal wall slot than a rectangular diffuser. Comparison of the results for two different supply temperatures in a DV room shows that, although lower supply temperature means less incoming air volume, since the indoor flow is mainly driven by buoyancy, lower supply temperature air could more efficiently remove passive sources (such as particles released from work activities in an office). However, in the breathing zone it gives higher concentration as compared to higher supply air temperature. To obtain good indoor air quality, low supply air temperature should be avoided because concentration in the breathing zone has a stronger and more direct impact on human health.
基金supported by Project 2017-II-0007-0021 of the National Science and Technology Major Project of China.
文摘A novel adjusting method for improving gas turbine(GT)efficiency and surge margin(SM)under partload conditions is proposed.This method adopts the inlet air heating technology,which uses the waste heat of lowgrade heat source and the inlet guide vane(IGV)opening adjustment.Moreover,the regulation rules of the compressor inlet air temperature and the IGV opening are studied comprehensively to optimize GT performance.A model and calculation method for an equilibrium running line is adopted based on the characteristic curves of the compressor and turbine.The equilibrium running lines calculated through the calculation method involve three part-load conditions and three IGVopenings with different inlet air temperatures.The results show that there is an optimal matching relationship between IGV opening and inlet air temperature.For the best GT performance of a given load,the IGV could be adjusted according to inlet air temperature.In addition,inlet air heating has a considerable potential for the improvement of part-load performance of GT due to the increase in compressor efficiency,combustion efficiency,and turbine efficiency as well as turbine inlet temperature,when inlet air temperature is lower than the optimal value with different IGV openings.Further,when the IGV is in a full opening state and an optimal inlet air temperature is achieved by using the inlet air heating technology,GT efficiency and SM can be obviously higher than other IGVopenings.The IGV can be left unadjusted,even when the load is as low as 50%.These findings indicate that inlet air heating has a great potential to replace the IGV to regulate load because GT efficiency and SM can be remarkably improved,which is different from the traditional viewpoints.
文摘针对高马赫数高温条件下飞机进气道射流预冷问题,本文建立了真实飞机全尺寸进气道-射流预冷装置一体化数值计算模型,通过控制变量法分析了进气流量、进气温度及射流流量对射流预冷装置性能的影响规律,发现进气流量与降温量呈负相关,与蒸发效率和温场均匀性呈正相关;进气温度与降温量、蒸发效率及温场均匀性均呈正相关;射流流量与降温量呈正相关,与蒸发效率及温场均匀性呈负相关。研究结果表明,在相同进气状态下,此飞机进气道的特殊构型会导致降温量和蒸发效率曲线在蒸发距离为2500mm处存在拐点。在此基础上,进一步提出了一种基于试验设计法(Design of experiment,DOE)评估进气道出口总温的评估方法,与试验结果对比发现该方法可将误差控制在5%以内。因此,采用该方法进行进气道出口总温预估是有效的。