期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
A Methodology for Assessing Axial Compressor Stability with Inlet Temperature Ramp Distortion
1
作者 SUN Dakun GU Benhao +4 位作者 NING Fangfei FANG Yibo DONG Xu XU Dengke SUN Xiaofeng 《Journal of Thermal Science》 SCIE EI CAS CSCD 2024年第3期856-871,共16页
Based on a small perturbation stability model for periodic flow,the effects of inlet total temperature ramp distortion on the axial compressor are investigated and the compressor stability is quantitatively evaluated.... Based on a small perturbation stability model for periodic flow,the effects of inlet total temperature ramp distortion on the axial compressor are investigated and the compressor stability is quantitatively evaluated.In the beginning,a small perturbation stability model for the periodic flow in compressors is proposed,referring to the governing equations of the Harmonic Balance Method.This stability model is validated on a single-stage low-speed compressor TA36 with uniform inlet flow.Then,the unsteady flow of TA36 with different inlet total temperature ramps and constant back pressure is simulated based on the Harmonic Balance Method.Based on these simulations,the compressor stability is analyzed using the proposed small perturbation model.Further,the Dynamic Mode Decomposition method is employed to accurately extract pressure oscillations.The two parameters of the temperature ramp,ramp rate and Strouhal number,are discussed in this paper.The results indicate the occurrence and extension of hysteresis loops in the rows,and a decrease in compressor stability with increasing ramp rate.Compressor performance is divided into two phases,stable and limit,based on the ramp rate.Furthermore,the model predictions suggest that a decrease in period length and an increase in Strouhal number lead to improved compressor stability.The DMD results imply that for compressors with inlet temperature ramp distortion,the increase of high-order modes and oscillations at the rotor tip is always the signal of decreasing stability. 展开更多
关键词 axial compressor stability small perturbation model inlet temperature ramp distortion harmonic balance method dynamic mode decomposition method
原文传递
Effects of supply air temperature and inlet location on particle dispersion in displacement ventilation rooms 被引量:5
2
作者 Yanming Kang Youjun Wang Ke Zhong 《Particuology》 SCIE EI CAS CSCD 2011年第6期619-625,共7页
The effects of supply temperature and vertical location of inlet air on particle dispersion in a displacement ventilated (DV) room were numerically modeled with validation by experimental data from the literature. T... The effects of supply temperature and vertical location of inlet air on particle dispersion in a displacement ventilated (DV) room were numerically modeled with validation by experimental data from the literature. The results indicate that the temperature and vertical location of inlet supply air did not greatly affect the air distribution in the upper parts of a DV room, but could significantly influence the airflow pattern in the lower parts of the room, thus affecting the indoor air quality with contaminant sources located at the lower level, such as particles from working activities in an office. The numerical results also show that the inlet location would slightly influence the relative ventilation efficiency for the same air supply volume, but particle concentration in the breathing zone would be slightly lower with a low horizontal wall slot than a rectangular diffuser. Comparison of the results for two different supply temperatures in a DV room shows that, although lower supply temperature means less incoming air volume, since the indoor flow is mainly driven by buoyancy, lower supply temperature air could more efficiently remove passive sources (such as particles released from work activities in an office). However, in the breathing zone it gives higher concentration as compared to higher supply air temperature. To obtain good indoor air quality, low supply air temperature should be avoided because concentration in the breathing zone has a stronger and more direct impact on human health. 展开更多
关键词 Displacement ventilation Particle dispersion Numerical simulation Supply air temperature inlet location
原文传递
Improvement of part-load performance of gas turbine by adjusting compressor inlet air temperature and IGV opening 被引量:1
3
作者 Wei ZHU Xiaodong REN +5 位作者 Xuesong LI Chunwei GU Zhitan LIU Zhiyuan YAN Hongfei ZHU Tao ZHANG 《Frontiers in Energy》 SCIE CSCD 2022年第6期1000-1016,共17页
A novel adjusting method for improving gas turbine(GT)efficiency and surge margin(SM)under partload conditions is proposed.This method adopts the inlet air heating technology,which uses the waste heat of lowgrade heat... A novel adjusting method for improving gas turbine(GT)efficiency and surge margin(SM)under partload conditions is proposed.This method adopts the inlet air heating technology,which uses the waste heat of lowgrade heat source and the inlet guide vane(IGV)opening adjustment.Moreover,the regulation rules of the compressor inlet air temperature and the IGV opening are studied comprehensively to optimize GT performance.A model and calculation method for an equilibrium running line is adopted based on the characteristic curves of the compressor and turbine.The equilibrium running lines calculated through the calculation method involve three part-load conditions and three IGVopenings with different inlet air temperatures.The results show that there is an optimal matching relationship between IGV opening and inlet air temperature.For the best GT performance of a given load,the IGV could be adjusted according to inlet air temperature.In addition,inlet air heating has a considerable potential for the improvement of part-load performance of GT due to the increase in compressor efficiency,combustion efficiency,and turbine efficiency as well as turbine inlet temperature,when inlet air temperature is lower than the optimal value with different IGV openings.Further,when the IGV is in a full opening state and an optimal inlet air temperature is achieved by using the inlet air heating technology,GT efficiency and SM can be obviously higher than other IGVopenings.The IGV can be left unadjusted,even when the load is as low as 50%.These findings indicate that inlet air heating has a great potential to replace the IGV to regulate load because GT efficiency and SM can be remarkably improved,which is different from the traditional viewpoints. 展开更多
关键词 inlet air temperature inlet guide vane(IGV)opening part-load equilibrium running line gas turbine(GT)efficiency surge margin(SM)
原文传递
NUMERICAL SIMULATION AND COMPARISON OF WATER INTAKE-OUTLET METHODS IN POWER PLANTS 被引量:3
4
作者 CHENG You-liang YING Bo-fen 《Journal of Hydrodynamics》 SCIE EI CSCD 2007年第5期623-629,共7页
The eclipsed form arrangement and march-past method of water intake-outlet arrangements in power plants were researched by 3-D numerical simulation based on the k-e two-equation turbulence model. Firstly, the flowing ... The eclipsed form arrangement and march-past method of water intake-outlet arrangements in power plants were researched by 3-D numerical simulation based on the k-e two-equation turbulence model. Firstly, the flowing characteristics of eclipsed form arrangement were analyzed and the effects of some main factors on inlet temperature were investigated. The simulation results are basically in agreement with those of the previous experiments. Then, by comparing the inlet temperature of the above two intake-outlet methods, the superiority and its existent conditions of the eclipsed form were examined. 展开更多
关键词 method water simulation eclipsed form arrangement intake-outlet inlet temperature march-past numerical
原文传递
Optimization of drying conditions and components to reduce wall sticking during spray drying of infant formula milk 被引量:1
5
作者 Yawen Lin Yanhong Liu +3 位作者 Lu Wang Yongkang Xie Zhenjiang Gao Shaojin Wang 《International Journal of Agricultural and Biological Engineering》 SCIE EI CAS 2018年第2期214-218,共5页
Wall sticking,which greatly reduces productivity and product quality,has been a big challenge of spray drying.Structure of drying tower and atomizer,as well as drying conditions are the main influencing factors.This r... Wall sticking,which greatly reduces productivity and product quality,has been a big challenge of spray drying.Structure of drying tower and atomizer,as well as drying conditions are the main influencing factors.This research explored the possibility to reduce wall sticking by optimizing drying conditions and components to obtain higher recovery rate of powdered infant formula milk(PIFM).Response surface experimental results indicated that inlet air temperature(T),feed concentration(C),feeding speed(S),as well as interaction term of TC and quadratic terms of C^(2) and S^(2) had significant influences on recovery rate for determined milk formula.According to mixture experiments at optimized drying conditions,whey protein(P),fat(F)and lactose(L)contents,as well as interaction term FL had significant effects on recovery rate.Positive effects were observed for F and L contents on recovery rate,while negative effects were observed for P and FL.Under the optimized drying condition of 136℃,19.80%and 4.07 mL/min,respectively,for T,C and S,the maximum recovery rate of 58.98%was obtained for PIFM with P,F and L content of 18%,31%and 51%,respectively.Wall sticking phenomena could be reduced by optimizing drying conditions and mildly adjusting components of infant formula milk. 展开更多
关键词 spray drying drying condition wall sticking inlet temperature feed concentration feeding speed powder recovery rate infant formula milk
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部