There are few studies on the dynamic-response mechanism of near-fault and far-field ground motions for large underground structures,especially for the branch joint of a utility tunnel(UT)and its internal pipeline.Base...There are few studies on the dynamic-response mechanism of near-fault and far-field ground motions for large underground structures,especially for the branch joint of a utility tunnel(UT)and its internal pipeline.Based on the theory of a 3D viscous-spring artificial boundary,this paper deduced the equivalent nodal force when a P wave and an SV wave were vertically incident at the same time and transformed the ground motion into an equivalent nodal force using a self-developed MATLAB program,which was applied to an ABAQUS finite element model.Based on near-fault and far-field groundmotions obtained fromtheNGA-WEST2 database,the dynamic responses of a utility tunnel and its internal pipeline in different inputmechanisms of near-fault and far-field groundmotions were compared according to bidirectional input and tridirectional input,respectively.Generally,the damage to the utility tunnel caused by the near-fault ground motion was stronger than that caused by the far-field ground motion,and the vertical ground motion of near-fault ground motion aggravated the damage to the utility tunnel.In addition,the joint dislocation of the upper and lower three-way joints of the pipeline in the branch systemunder the seismic action led to local stress concentrations.In general,the branch system of the utility tunnel had good seismic performance to resist the designed earthquake action and protect the internal pipeline fromdamage during the rare earthquake.展开更多
以4种场地土条件下40条强震记录为输入,分析了弹塑性单自由度(Single Degree of Freedom,SDOF)系统的地震输入能量谱,并对地震动强度和SDOF系统参数对地震输入能量谱的影响进行了研究。结果表明:能量谱峰值主要由地震动强度决定,阻尼比...以4种场地土条件下40条强震记录为输入,分析了弹塑性单自由度(Single Degree of Freedom,SDOF)系统的地震输入能量谱,并对地震动强度和SDOF系统参数对地震输入能量谱的影响进行了研究。结果表明:能量谱峰值主要由地震动强度决定,阻尼比和延性系数有很大影响。在长周期范围,延性系数一定时,随着阻尼比的增大,能量谱值也有所增大;随延性系数增大,能量谱值随阻尼比增加而增大的趋势有所减缓。采用归一化方法,根据能量谱的特征建议了简化三段式地震输入能量谱,并根据能量谱分析结果的统计,建议了弹塑性SDOF系统能量谱峰值和能量谱曲线参数的确定方法。展开更多
基金National Key R&D Program of China under Grants No.2019YFC1509301.
文摘There are few studies on the dynamic-response mechanism of near-fault and far-field ground motions for large underground structures,especially for the branch joint of a utility tunnel(UT)and its internal pipeline.Based on the theory of a 3D viscous-spring artificial boundary,this paper deduced the equivalent nodal force when a P wave and an SV wave were vertically incident at the same time and transformed the ground motion into an equivalent nodal force using a self-developed MATLAB program,which was applied to an ABAQUS finite element model.Based on near-fault and far-field groundmotions obtained fromtheNGA-WEST2 database,the dynamic responses of a utility tunnel and its internal pipeline in different inputmechanisms of near-fault and far-field groundmotions were compared according to bidirectional input and tridirectional input,respectively.Generally,the damage to the utility tunnel caused by the near-fault ground motion was stronger than that caused by the far-field ground motion,and the vertical ground motion of near-fault ground motion aggravated the damage to the utility tunnel.In addition,the joint dislocation of the upper and lower three-way joints of the pipeline in the branch systemunder the seismic action led to local stress concentrations.In general,the branch system of the utility tunnel had good seismic performance to resist the designed earthquake action and protect the internal pipeline fromdamage during the rare earthquake.
文摘以4种场地土条件下40条强震记录为输入,分析了弹塑性单自由度(Single Degree of Freedom,SDOF)系统的地震输入能量谱,并对地震动强度和SDOF系统参数对地震输入能量谱的影响进行了研究。结果表明:能量谱峰值主要由地震动强度决定,阻尼比和延性系数有很大影响。在长周期范围,延性系数一定时,随着阻尼比的增大,能量谱值也有所增大;随延性系数增大,能量谱值随阻尼比增加而增大的趋势有所减缓。采用归一化方法,根据能量谱的特征建议了简化三段式地震输入能量谱,并根据能量谱分析结果的统计,建议了弹塑性SDOF系统能量谱峰值和能量谱曲线参数的确定方法。