Coronary angiography is considered to be the gold standard in the morphological evaluation of coronary artery stenosis. The morphological assessment of the severity of a coronary lesion is very subjective. Thus, the i...Coronary angiography is considered to be the gold standard in the morphological evaluation of coronary artery stenosis. The morphological assessment of the severity of a coronary lesion is very subjective. Thus, the invasive fractional flow reserve(FFR) measurement represents the current standard for estimation of the hemodynamic significance of coronary artery stenosis. The FFR-guided revascularization strategy was initially classified as a Class-IA-recommendation in the 2014 European Society of Cardiology/European Association for Cardio-Thoracic Surgery guidelines on myocardial revascularization. Both the Deferral vs Performance of Percutaneous Coronary Intervention of Functionally Non-Significant Coronary Stenosis and Flow Reserve vs Angiography for Multivessel Evaluation studies showed no treatment advantage for hemodynamically insignificant stenoses. With the help of FFR(and targeted interventions), clinical results could be improved; however, the use in clinical practice is still limited due to the need of adenosine administration and a significant prolongation of the length of the procedure. Instantaneous wave-free ratio(iFR~) is a new innovative approach for the determination of the hemodynamic significance of coronary stenosis, which can be obtained at rest without the use of vasodilators. Regarding the periprocedural complications as well as prognosis, iFR~ showed non-inferiority to FFR in the SWEDEHEART and DEFINE-FLAIR trials. Furthermore, iFR~, enhanced by iFR~-pullback, provides the possibility to display the iFR~-change over the course of the vessel to create a hemodynamic map.展开更多
An approach based on multi-scale ehirplet sparse signal decomposition is proposed to separate the malti-component polynomial phase signals, and estimate their instantaneous frequencies. In this paper, we have generate...An approach based on multi-scale ehirplet sparse signal decomposition is proposed to separate the malti-component polynomial phase signals, and estimate their instantaneous frequencies. In this paper, we have generated a family of multi-scale chirplet functions which provide good local correlations of chirps over shorter time interval. At every decomposition stage, we build the so-called family of chirplets and our idea is to use a structured algorithm which exploits information in the family to chain chirplets together adaptively as to form the polyncmial phase signal component whose correlation with the current residue signal is largest. Simultaueously, the polynomial instantaneous frequency is estimated by connecting the linear frequency of the chirplet functions adopted in the current separation. Simulation experiment demonstrated that this method can separate the camponents of the multi-component polynamial phase signals effectively even in the low signal-to-noise ratio condition, and estimate its instantaneous frequency accurately.展开更多
The accurate estimation of the rolling element bearing instantaneous rotational frequency(IRF) is the key capability of the order tracking method based on time-frequency analysis. The rolling element bearing IRF can b...The accurate estimation of the rolling element bearing instantaneous rotational frequency(IRF) is the key capability of the order tracking method based on time-frequency analysis. The rolling element bearing IRF can be accurately estimated according to the instantaneous fault characteristic frequency(IFCF). However, in an environment with a low signal-to-noise ratio(SNR), e.g., an incipient fault or function at a low speed, the signal contains strong background noise that seriously affects the effectiveness of the aforementioned method. An algorithm of signal preprocessing based on empirical mode decomposition(EMD) and wavelet shrinkage was proposed in this work. Compared with EMD denoising by the cross-correlation coefficient and kurtosis(CCK) criterion, the method of EMD soft-thresholding(ST) denoising can ensure the integrity of the signal, improve the SNR, and highlight fault features. The effectiveness of the algorithm for rolling element bearing IRF estimation by EMD ST denoising and the IFCF was validated by both simulated and experimental bearing vibration signals at a low SNR.展开更多
The paper considers the modification or the manufacture error of cycloidal gear, then analyzes the relationship of pin circle meshed with the modified cycloidal gear, discuases the amount of error that leads to destro...The paper considers the modification or the manufacture error of cycloidal gear, then analyzes the relationship of pin circle meshed with the modified cycloidal gear, discuases the amount of error that leads to destroying conjugate action and results in the changes of tbe instantaneous velocity ratio and so as to affect the smooth operation of cycloidal pin gearing. The idea of the relationship between amount of modification aud manufacture error and the smooth operation can be gotten from the curve diagrams of the instantaneous velocity ratio. Therefore, the directions for improving the reature of the cycloidal pin gear transmission are clear.展开更多
文摘Coronary angiography is considered to be the gold standard in the morphological evaluation of coronary artery stenosis. The morphological assessment of the severity of a coronary lesion is very subjective. Thus, the invasive fractional flow reserve(FFR) measurement represents the current standard for estimation of the hemodynamic significance of coronary artery stenosis. The FFR-guided revascularization strategy was initially classified as a Class-IA-recommendation in the 2014 European Society of Cardiology/European Association for Cardio-Thoracic Surgery guidelines on myocardial revascularization. Both the Deferral vs Performance of Percutaneous Coronary Intervention of Functionally Non-Significant Coronary Stenosis and Flow Reserve vs Angiography for Multivessel Evaluation studies showed no treatment advantage for hemodynamically insignificant stenoses. With the help of FFR(and targeted interventions), clinical results could be improved; however, the use in clinical practice is still limited due to the need of adenosine administration and a significant prolongation of the length of the procedure. Instantaneous wave-free ratio(iFR~) is a new innovative approach for the determination of the hemodynamic significance of coronary stenosis, which can be obtained at rest without the use of vasodilators. Regarding the periprocedural complications as well as prognosis, iFR~ showed non-inferiority to FFR in the SWEDEHEART and DEFINE-FLAIR trials. Furthermore, iFR~, enhanced by iFR~-pullback, provides the possibility to display the iFR~-change over the course of the vessel to create a hemodynamic map.
基金supported by the National Science Foundation of China(No.50875078)
文摘An approach based on multi-scale ehirplet sparse signal decomposition is proposed to separate the malti-component polynomial phase signals, and estimate their instantaneous frequencies. In this paper, we have generated a family of multi-scale chirplet functions which provide good local correlations of chirps over shorter time interval. At every decomposition stage, we build the so-called family of chirplets and our idea is to use a structured algorithm which exploits information in the family to chain chirplets together adaptively as to form the polyncmial phase signal component whose correlation with the current residue signal is largest. Simultaueously, the polynomial instantaneous frequency is estimated by connecting the linear frequency of the chirplet functions adopted in the current separation. Simulation experiment demonstrated that this method can separate the camponents of the multi-component polynamial phase signals effectively even in the low signal-to-noise ratio condition, and estimate its instantaneous frequency accurately.
基金Project(51275030)supported by the National Natural Science Foundation of ChinaProject(2016JBM051)supported by the Fundamental Research Funds for the Central Universities,China
文摘The accurate estimation of the rolling element bearing instantaneous rotational frequency(IRF) is the key capability of the order tracking method based on time-frequency analysis. The rolling element bearing IRF can be accurately estimated according to the instantaneous fault characteristic frequency(IFCF). However, in an environment with a low signal-to-noise ratio(SNR), e.g., an incipient fault or function at a low speed, the signal contains strong background noise that seriously affects the effectiveness of the aforementioned method. An algorithm of signal preprocessing based on empirical mode decomposition(EMD) and wavelet shrinkage was proposed in this work. Compared with EMD denoising by the cross-correlation coefficient and kurtosis(CCK) criterion, the method of EMD soft-thresholding(ST) denoising can ensure the integrity of the signal, improve the SNR, and highlight fault features. The effectiveness of the algorithm for rolling element bearing IRF estimation by EMD ST denoising and the IFCF was validated by both simulated and experimental bearing vibration signals at a low SNR.
文摘The paper considers the modification or the manufacture error of cycloidal gear, then analyzes the relationship of pin circle meshed with the modified cycloidal gear, discuases the amount of error that leads to destroying conjugate action and results in the changes of tbe instantaneous velocity ratio and so as to affect the smooth operation of cycloidal pin gearing. The idea of the relationship between amount of modification aud manufacture error and the smooth operation can be gotten from the curve diagrams of the instantaneous velocity ratio. Therefore, the directions for improving the reature of the cycloidal pin gear transmission are clear.