期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Research on ballistic missile laser SIMU error propagation mechanism 被引量:5
1
作者 Wei Shihui Xiao Longxu 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2008年第2期356-362,共7页
It is necessary that the laser inertial system is used to further improve the fire accuracy and quick reaction capability in the ballistic missile strapdown inertial navigation system. According to the guidance contro... It is necessary that the laser inertial system is used to further improve the fire accuracy and quick reaction capability in the ballistic missile strapdown inertial navigation system. According to the guidance controlling method and the output and error model of ballistic missile laser SIMU, the mathematical model of error propagation mechanism is set up and any transfer environmental function of error coefficient that affects the fire accuracy is deduced. Also, the missile longitudinal/lateral impact point is calculated using MATLAB. These establish the technical foundation for further researching the dispersion characteristics of impact point and reducing the laser guidance error. 展开更多
关键词 ballistic missile laser SIMU instrument error impact point deviations environmental function.
下载PDF
Iterative identification of output error model for industrial processes with time delay subject to colored noise 被引量:1
2
作者 董世健 刘涛 +1 位作者 李明忠 曹毅 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2015年第12期2005-2012,共8页
To deal with colored noise and unexpected load disturbance in identification of industrial processes with time delay, a bias-eliminated iterative least-squares(ILS) identification method is proposed in this paper to e... To deal with colored noise and unexpected load disturbance in identification of industrial processes with time delay, a bias-eliminated iterative least-squares(ILS) identification method is proposed in this paper to estimate the output error model parameters and time delay simultaneously. An extended observation vector is constructed to establish an ILS identification algorithm. Moreover, a variable forgetting factor is introduced to enhance the convergence rate of parameter estimation. For consistent estimation, an instrumental variable method is given to deal with the colored noise. The convergence and upper bound error of parameter estimation are analyzed. Two illustrative examples are used to show the effectiveness and merits of the proposed method. 展开更多
关键词 Time delay system Output error model Recursive least-squares instrumental variable Variable forgetting factor
下载PDF
Influence of X-ray Powder Diffraction Instrument Error on Crystalline Structure Analysis
3
作者 HUANGQing-Ming YUJian-Chang WANGYun-Min WUWan-Guo 《Chinese Journal of Structural Chemistry》 SCIE CAS CSCD 北大核心 2005年第6期691-695,共5页
Standard mica was used to correct the X-ray powder diffraction instrument error and mathematic methods were employed to find the correction equation. By analyzing mullite sample and comparing the corrected and uncorre... Standard mica was used to correct the X-ray powder diffraction instrument error and mathematic methods were employed to find the correction equation. By analyzing mullite sample and comparing the corrected and uncorrected analysis results we found the former is obviously more reasonable. So the conclusion is that the X-ray powder diffraction instrument error greatly affects the crystalline structure analysis, and the above method is convenient and effective for the correction of instrument error. 展开更多
关键词 instrument error structure analysis polycrystalline diffraction
下载PDF
A novel wide-range precision instrument for measuring three-dimensional surface topography
4
作者 杨旭东 《Journal of Chongqing University》 CAS 2008年第1期52-57,共6页
We developed a measuring instrument that had wide range, high precision, small measuring touch force. The instrument for three-dimensional (3D) surface topography measurement was composed of a high precision displacem... We developed a measuring instrument that had wide range, high precision, small measuring touch force. The instrument for three-dimensional (3D) surface topography measurement was composed of a high precision displacement sensor based on the Michelson interference principle, a 3D platform based on vertical scanning, a measuring and control circuit, and an industrial control computer. It was a closed loop control system, which changed the traditional moving stylus scanning style into a moving platform scanning style. When the workpiece was measured, the lever of the displacement sensor returned to the balanced position in every sample interval according to the zero offset of the displacement sensor. The non-linear error caused by the rotation of the lever was, therefore, very small even if the measuring range was wide. The instrument can measure the roughness and the profile size of a curved surface. 展开更多
关键词 instrument circuit surface topography measurement error wide range precision instrument displacement sensor 3D platform
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部