期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Study of Enterprise Equipment Maintenance Management Integrated Information System Based on B/S 被引量:3
1
作者 HAO Lina XU Xinhe 《International Journal of Plant Engineering and Management》 2000年第4期154-160,共7页
Equipment maintenance management integrated information system is an important constituent part of enterprise IMS (Intelligent Manufacture System). The system should make the best of all kinds of information sources a... Equipment maintenance management integrated information system is an important constituent part of enterprise IMS (Intelligent Manufacture System). The system should make the best of all kinds of information sources around the enterprise, and meet the demand for agile production. This paper presents an implementation scheme of Integrated Equipment Maintenance Management Information System Based on Internet/Intranet and gives component division scheme of each tier. This scheme adopts a three-tiers mode of B/S (Browser/Server) and software programming module based on software reusing technology. This makes the system integrated and open, makes maintenance and updating convenient, and largely increases software safety and reusability. 展开更多
关键词 equipment maintenance management integrated information system COMPONENT INTERNET/INTRANET Browser/Server?
下载PDF
Effect of Micro-electrolysis and Micro-nano Bubbles Coupled with Peroxymonosulfate Treatment of Rural Domestic Sewage
2
作者 Peng ZHOU Yixin XU +3 位作者 Dongmei CHEN Cheng WU Xiaosi LEI Li FENG 《Meteorological and Environmental Research》 2024年第4期54-57,共4页
With the continuous deepening of rural revitalization strategy and the increasingly strict sewage discharge standards,rural domestic sewage treatment technology is facing higher challenges and requirements.The combine... With the continuous deepening of rural revitalization strategy and the increasingly strict sewage discharge standards,rural domestic sewage treatment technology is facing higher challenges and requirements.The combined process of micro-electrolysis+micro-nano bubbles coupled with peroxymonosulfate was constructed in this study,and the treatment effect and application value of this technology were explored with the actual rural domestic sewage as the treatment object.The experimental results showed that under the conditions of HRT of 120 min,PMS dosage of 0.15 mmol/L,pH=7,MBs air intake of 15 ml/min,current intensity of 15 A,and Fe/C mass ratio of 1:1,the removal rates of COD,ammonia nitrogen and total phosphorus can reach 88.55%,77.18%and 74.67%,respectively.Under the condition that the pH value of sewage was not adjusted,the non-biochemical simultaneous decarbonization,denitrification and phosphorus removal of rural domestic sewage can be achieved by micro-electrolysis and micro-nano bubbles coupled with peroxymonosulfate.The concentrations of effluent COD,ammonia nitrogen and total phosphorus met the requirements of the first level standard of the Discharge Standard of Water Pollutants for Rural Domestic Sewage Treatment Facilities(DB45T2413-2021).And the comprehensive operating cost was about 1.15 yuan/m 3. 展开更多
关键词 integrated equipment Rural domestic sewage Micro-nano bubbles PEROXYMONOSULFATE MICRO-ELECTROLYSIS
下载PDF
Predicting stability of integrated circuit test equipment using upper side boundary values of normal distribution
3
作者 Zhan Wenfa Hu Xinyi +3 位作者 Zheng Jiangyun Yu Chuxian Cai Xueyuan Zhang Lihua 《The Journal of China Universities of Posts and Telecommunications》 EI CSCD 2024年第2期85-93,共9页
In response to the growing complexity and performance of integrated circuit(IC),there is an urgent need to enhance the testing and stability of IC test equipment.A method was proposed to predict equipment stability us... In response to the growing complexity and performance of integrated circuit(IC),there is an urgent need to enhance the testing and stability of IC test equipment.A method was proposed to predict equipment stability using the upper side boundary value of normal distribution.Initially,the K-means clustering algorithm classifies and analyzes sample data.The accuracy of this boundary value is compared under two common confidence levels to select the optimal threshold.A range is then defined to categorize unqualified test data.Through experimental verification,the method achieves the purpose of measuring the stability of qualitative IC equipment through a deterministic threshold value and judging the stability of the equipment by comparing the number of unqualified data with the threshold value,which realizes the goal of long-term operation monitoring and stability analysis of IC test equipment. 展开更多
关键词 K-means clustering algorithm the upper side boundary of normal distribution THRESHOLD integrated circuit(IC)test equipment stability analysis
原文传递
Smart Substation Integration Technology and Its Application in Distribution Power Grid 被引量:7
4
作者 Qipeng Song Wanxing Sheng +4 位作者 Lingfeng Kou Dongbo Zhao Ziping Wu Hengfu Fang Xiaolong Zhao 《CSEE Journal of Power and Energy Systems》 SCIE 2016年第4期31-36,共6页
At present,smart substations use the IEC61850 standard based on the architectural framework of three layers and two networks to realize information digitization and advanced applications.Although the smart substation ... At present,smart substations use the IEC61850 standard based on the architectural framework of three layers and two networks to realize information digitization and advanced applications.Although the smart substation offers many improvements in design,equipment manufacturing,and construction,the intelligent devices used in smart substations are costly,and are also difficult to maintain since they are dispersed within a single unit.Functionality optimization and device integration,thus,have become important issues in smart substation development.This paper presents an integrated solution and implementation process for a smart substation system.In the process layer,an integrated intelligence component is developed that functions both as an intelligent terminal and a merging unit.In the bay layer,an integrated station-area protection measurement and control master device is designed to achieve such functions as protection,monitoring,control,fault recorder,and power quality monitoring.Finally,in the station control layer,an integrated information platform is established to bring together various system functions and to promote interactive sharing.Integration technology improves the economy and practicality of the smart substation,especially in a distribution power grid. 展开更多
关键词 equipment integration integrated intelligent components smart substation substation-area monitoring and protection three layers and two networks
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部