Dear Editor: There is accumulating evidence that human blood electronic circuit components and their application circuits become more and more important to cyborg implant/engineering, man-machine interface, hu- man ...Dear Editor: There is accumulating evidence that human blood electronic circuit components and their application circuits become more and more important to cyborg implant/engineering, man-machine interface, hu- man disease detection and healing, and artificial brain evolutionusl. Here, we report the first development of human plasma-based amplifier circuit in the dis- crete as well as integrated circuit (IC) configuration mode. Electrolytes in the human blood contain an enormous number of charge carriers such as positive and negative molecule/atom ions, which are electri- cally conducting media and therefore can be utilized for developing electronic circuit components and their application circuits. These electronic circuits obvi- ously have very high application impact potential towards bio-medical engineering and medical science and technology.展开更多
In this work, a novel airframe/propulsion integration design method of the wing-body configuration for hypersonic cruise aircraft is proposed, where the configuration is integrated with inward-turning inlets. With the...In this work, a novel airframe/propulsion integration design method of the wing-body configuration for hypersonic cruise aircraft is proposed, where the configuration is integrated with inward-turning inlets. With the help of this method, the major design concern of balancing the aerodynamic performance against the requirements for efficient propulsion can be well addressed. A novel geometric parametrically modelling method based on a combination of patched class and shape transition(CST) and COONs surface is proposed to represent the configuration, especially a complex configuration with an irregular inlet lip shape. The modelling method enlarges the design space of components on the premise of guaranteeing the configuration integrity via special constraints imposed on the interface across adjacent surfaces. A basic flow inside a cone shaped by a dual-inflection-point generatrix is optimized to generate the inward-turning inlet with improvements of both compression efficiency and flow uniformity. The performance improvement mechanism of this basic flow is the compression velocity variation induced by the variation of the generatrix slope along the flow path. At the design point, numerical simulation results show that the lift-to-drag ratio of the configuration is as high as 5.2 and the inlet works well with a high level of compression efficiency and flow uniformity. The design result also has a good performance on off-design conditions. The achievement of all the design targets turns out that the integration design method proposed in this paper is efficient and practical.展开更多
We propose an ultra-simple dual-channel configuration for simultaneously evaluating two branches of a multifunctional integrated optic chip(MFIOC). In the configuration, the MFIOC is employed as a beam splitter to con...We propose an ultra-simple dual-channel configuration for simultaneously evaluating two branches of a multifunctional integrated optic chip(MFIOC). In the configuration, the MFIOC is employed as a beam splitter to construct the demodulation interferometer together with a 2 × 2 fiber coupler. Interference happens between polarization modes traveling through different channels of the MFIOC. The cross-couplings of each channel are respectively characterized by the interference peaks which distribute on opposite sides of the central interference peak. Temperature responses of the MFIOC are experimentally measured from-40°C to 80°C. Results show that the proposed configuration can achieve simultaneous dual-channel transient measurements with resolution of-90 d B and dynamic range of 90 d B. In addition, the two channels of the configuration have consistent measuring performance, and the two branches of the MFIOC have different responses to temperature variation.展开更多
文摘Dear Editor: There is accumulating evidence that human blood electronic circuit components and their application circuits become more and more important to cyborg implant/engineering, man-machine interface, hu- man disease detection and healing, and artificial brain evolutionusl. Here, we report the first development of human plasma-based amplifier circuit in the dis- crete as well as integrated circuit (IC) configuration mode. Electrolytes in the human blood contain an enormous number of charge carriers such as positive and negative molecule/atom ions, which are electri- cally conducting media and therefore can be utilized for developing electronic circuit components and their application circuits. These electronic circuits obvi- ously have very high application impact potential towards bio-medical engineering and medical science and technology.
基金supported by the ‘‘111" Project of China (No. B17037)
文摘In this work, a novel airframe/propulsion integration design method of the wing-body configuration for hypersonic cruise aircraft is proposed, where the configuration is integrated with inward-turning inlets. With the help of this method, the major design concern of balancing the aerodynamic performance against the requirements for efficient propulsion can be well addressed. A novel geometric parametrically modelling method based on a combination of patched class and shape transition(CST) and COONs surface is proposed to represent the configuration, especially a complex configuration with an irregular inlet lip shape. The modelling method enlarges the design space of components on the premise of guaranteeing the configuration integrity via special constraints imposed on the interface across adjacent surfaces. A basic flow inside a cone shaped by a dual-inflection-point generatrix is optimized to generate the inward-turning inlet with improvements of both compression efficiency and flow uniformity. The performance improvement mechanism of this basic flow is the compression velocity variation induced by the variation of the generatrix slope along the flow path. At the design point, numerical simulation results show that the lift-to-drag ratio of the configuration is as high as 5.2 and the inlet works well with a high level of compression efficiency and flow uniformity. The design result also has a good performance on off-design conditions. The achievement of all the design targets turns out that the integration design method proposed in this paper is efficient and practical.
基金the National Natural Science Foundation of China (Grants Nos. 61227013, 61307104,61422505)the Program for New Century Excellent Talents in University (NCET-12-0623)+2 种基金the National Key Scientific Instrument and Equipment Development Project (No. 2013YQ040815)the Specialized Research Fund for the Doctoral Program of Higher Education (No. 20122304110022)the Heilongjiang Provincial Natural Science Foundation (No. ZD201205)
文摘We propose an ultra-simple dual-channel configuration for simultaneously evaluating two branches of a multifunctional integrated optic chip(MFIOC). In the configuration, the MFIOC is employed as a beam splitter to construct the demodulation interferometer together with a 2 × 2 fiber coupler. Interference happens between polarization modes traveling through different channels of the MFIOC. The cross-couplings of each channel are respectively characterized by the interference peaks which distribute on opposite sides of the central interference peak. Temperature responses of the MFIOC are experimentally measured from-40°C to 80°C. Results show that the proposed configuration can achieve simultaneous dual-channel transient measurements with resolution of-90 d B and dynamic range of 90 d B. In addition, the two channels of the configuration have consistent measuring performance, and the two branches of the MFIOC have different responses to temperature variation.