Clinical study on concurrent and sequential therapy of intensity modulated radiation therapy (IMRT) combined with NP regimen chemotherapy in the treatment of middle and advanced non-small cell lung cancer
1
作者 Xiaodong Jiang Da'an Song Weiming Zhang Jin Wu 《The Chinese-German Journal of Clinical Oncology》 CAS 2007年第1期2-4,共3页
Objective: To evaluate the clinical effects of concurrent and sequential therapy for middle and advanced stage non-small cell lung cancer (NSCLC) useing IMRT combined with NP regimen chemotherapy. Methods: Eighty pati... Objective: To evaluate the clinical effects of concurrent and sequential therapy for middle and advanced stage non-small cell lung cancer (NSCLC) useing IMRT combined with NP regimen chemotherapy. Methods: Eighty patients with middle and advanced stage NSCLC were randomized into two groups. Forty patients were underwent sequential therapy and other 40 patients were underwent concurrent therapy. IMRT was used in radiotherapy and NP regimen of vinorelbine+cispatin (NP) was used in chemotherapy. Results: (1) The overall response (CR+PR) rate was 75% in concurrent group and 45% in sequential group (P<0.05); (2) The treatment courses were 84 days and 140 days for concurrent group and sequential group respectively (P<0.05); (3) One-year survival rate in concurrent group was 72.4% and 52.3% in sequential group respectively; (4) The toxic effects can be tolerable by all of patients. Conclusion: The concurrent chemo-radiotherapy has better overall re- sponse, one-year survival rate and shorter treatment course than the sequential chemo-radiotherapy, so it is a better method for the treatment of middle and advanced stage NSCLC, but the long term survival rate will be studied. 展开更多
关键词 non-small cell lung cancer (NSCLC) intensity modulated radiation therapy (imrt CHEMOtherapy concurrent therapy sequential therapy
下载PDF
Verification of Dosimetric and Positional Accuracy of Dynamic Tumor Tracking Intensity Modulated Radiation Therapy
2
作者 Masaki Sueoka Akira Sawada +6 位作者 Hiroaki Tanabe Yuki Okada Sho Taniuchi Noboru Okuuchi Masao Tanooka Masaki Kokubo Koichiro Yamakado 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2019年第4期211-224,共14页
Purpose: We performed both, dosimetric and positional accuracy verification of dynamic tumor tracking (DTT) intensity modulated radiation therapy (IMRT), with the Vero4DRT system using a moving phantom (QUASAR respira... Purpose: We performed both, dosimetric and positional accuracy verification of dynamic tumor tracking (DTT) intensity modulated radiation therapy (IMRT), with the Vero4DRT system using a moving phantom (QUASAR respiratory motion platform;QUASAR phantom) and system log files. Methods: The QUASAR phantom was placed on a treatment couch. Measurement of the point dose and dose distribution was performed for conventional IMRT, with the QUASAR phantom static and moving;for DTT IMRT, this was performed with the phantom moving for pyramid shaped, prostate, paranasal sinus, and pancreas targets. The QUASAR phantom was driven by a sinusoidal signal in the superior-inferior direction. Furthermore, predicted positional errors induced by the Vero4DRT system and mechanical positional errors of the gimbal head, were calculated using the system log files. Results and Conclusion: For DTT IMRT, the dose at the evaluation point was within 3% compared with the verification plan, and the dose distribution in the passing rates of γ was 97.9%, with the criteria of 3% dose and 3 mm distance to agreement. The position error calculated from the log files was within 2 mm, suggesting the feasibility of employing DTT IMRT with high accuracy using the Vero4DRT system. 展开更多
关键词 DYNAMIC Tumor Tracking (DTT) intensity Modulated radiation therapy (imrt) Point DOSE VERIFICATION DOSE Distribution VERIFICATION Log FILE Analysis
下载PDF
Local definitive intensity-modulated radiation therapy recommended for patients initially diagnosed with nasopharyngeal carcinoma with distant metastasis after an effective systemic chemotherapy
3
作者 Lei Zhou Dongbo Liu 《Oncology and Translational Medicine》 2018年第6期234-237,共4页
Objective The aim of the study was to propose a hypothesis that local definitive intensity-modulated radiation therapy(IMRT) should be recommended for initially diagnosed metastatic nasopharyngeal carcinoma(NPC) and d... Objective The aim of the study was to propose a hypothesis that local definitive intensity-modulated radiation therapy(IMRT) should be recommended for initially diagnosed metastatic nasopharyngeal carcinoma(NPC) and demonstrate its feasibility.Methods Recently published papers on local definitive radiotherapy for initially diagnosed metastatic NPC were reviewed to propose a hypothesis.Results Several studies revealed the survival benefits of adding local definitive radiotherapy to the systemic chemotherapy in patients initially diagnosed with metastatic NPC.Conclusion We suggested that local definitive IMRT should be recommended in patients initially diagnosed with NPC with distant metastasis after an effective systemic chemotherapy, which may possibly prolong their survival time and potentially treat the disease. 展开更多
关键词 NASOPHARYNGEAL carcinoma(NPC) METASTASIS intensity-MODULATED radiation therapy(imrt)
下载PDF
The impact of intensity modulated radiotherapy on the skin dose for deep seated tumors
4
作者 H. S. Abou-Elenein Ehab M. Attalla +3 位作者 Hany Ammar Ismail Eldesoky Mohamed Farouk Shaimaa Shoer 《The Chinese-German Journal of Clinical Oncology》 CAS 2013年第4期194-198,共5页
Objective: The purpose of this study was to investigate the impact of intensity modulated radiotherapy (IMRT) on surface doses for brain, abdomen and pelvis deep located tumors treated with 6 MV photon and to evaluate... Objective: The purpose of this study was to investigate the impact of intensity modulated radiotherapy (IMRT) on surface doses for brain, abdomen and pelvis deep located tumors treated with 6 MV photon and to evaluate the skin dose calculation accuracy of the XIO 4.04 treatment planning system. Methods: More investigations for the influences of IMRT on skin doses would increase its applications for many treatment sites. Measuring skin doses in real treatment situations would reduce the uncertainty of skin dose prediction. In this work a pediatric human phantom was covered by a layer of 1 mm bolus at three treatment sites and thermoluminescent dosimeter (TLD) chips were inserted into the bolus at each treatment site before CT scan. Two different treatment plans [three-dimensional conformal radiation therapy (3DCRT) and IMRT] for each treatment sites were performed on XIO 4.04 treatment planning system using superposition algorism. Results: The results showed that the surface doses for 3DCRT were higher than the surface doses in IMRT by 1.6%, 2.5% and 3.2% for brain, abdomen and pelvis sites respectively. There was good agreement between measured and calculated surface doses, where the calculated surface dose was 15.5% for brain tumor calculated with 3DCRT whereas the measured surface dose was 12.1%. For abdomen site the calculated surface dose for IMRT treatment plan was 16.5% whereas the measured surface dose was 12.6%. Conclusion: The skin dose in IMRT for deep seated tumors is lower than that in 3DCRT which is another advantage for the IMRT. The TLD readings showed that the difference between the calculated and measured point dose is negligible. The superposition calculation algorism of the XIO 4.04 treatment planning system modeled the superficial dose well. 展开更多
关键词 skin dose intensity modulated radiotherapy (imrt three-dimensional conformal radiation therapy (3DCRT) thermoluminescent dosimeter (TLD) dose calculation
下载PDF
重叠体积直方图描述子的计算方法和其在鼻咽癌IMRT计划检索中的应用 被引量:5
5
作者 王东东 周正东 +3 位作者 宋威 李兵 沈君姝 朱锡旭 《中国生物医学工程学报》 CAS CSCD 北大核心 2014年第3期373-378,共6页
调强放射治疗(IMRT)计划制定效率不高、难以保证治疗计划的高质量是目前调强放射治疗技术中一直存在的问题之一,基于形状的IMRT计划检索技术为缩短IMRT计划制定周期、提高放射治疗计划质量提供了一种新方法。本研究建立了一种适用于IMR... 调强放射治疗(IMRT)计划制定效率不高、难以保证治疗计划的高质量是目前调强放射治疗技术中一直存在的问题之一,基于形状的IMRT计划检索技术为缩短IMRT计划制定周期、提高放射治疗计划质量提供了一种新方法。本研究建立了一种适用于IMRT计划检索的重叠体积直方图(OVH)形状关系的关系描述算子,提出一种基于Matlab的计算方法。利用一例临床实际的鼻咽癌病例分析了OVH描述子的描述特性,利用22例临床鼻咽癌IMRT计划研究了其形状关系检索的性能。实验结果表明OVH描述子能够简洁的描述放疗三维场景中靶区和危及器官间的三维形状关系特征,并且能够有效检索出相似度较高的一组形状,适合于基于形状的IMRT计划检索。 展开更多
关键词 重叠体积直方图 形状关系描述算子 调强放射治疗 放疗计划优化
下载PDF
IMRT联合顺铂治疗宫颈癌的临床疗效及安全性研究 被引量:1
6
作者 张青冬 姜艳萍 +1 位作者 冯晓萍 汪萍萍 《中国性科学》 2018年第2期48-51,共4页
目的:研究IMRT联合顺铂治疗宫颈癌的临床疗效及安全性。方法:回顾性随机选择在2012年8月至2013年8月我院收治的136例宫颈癌患者,并按双盲数字法将其分为对照组和观察组。对照组患者采用单一的调强放射治疗(IMRT)治疗,观察组患者在调强... 目的:研究IMRT联合顺铂治疗宫颈癌的临床疗效及安全性。方法:回顾性随机选择在2012年8月至2013年8月我院收治的136例宫颈癌患者,并按双盲数字法将其分为对照组和观察组。对照组患者采用单一的调强放射治疗(IMRT)治疗,观察组患者在调强放射治疗(IMRT)治疗的基础上联合顺铂治疗。对患者进行定期回访3年,统计患者治疗3个月内复查结果为近期疗效及远期疗效。结果:通过对比,观察组治疗的有效率89.71%明显高于对照组治疗的有效率80.88%,差异具有统计学意义(P<0.05)。对比两组患者在治疗1年内,两组患者的生存率、局部控制率及无瘤生存率无明显差异,数据无统计学意义(P>0.05);但治疗1~3年内,观察组患者的生存率、远处转移率、局部控制率及无瘤生存率明显低于对照组,远处转移率明显低于对照组,差异对比有统计学意义(P<0.05)。观察组不良反应胃肠道反应、白细胞下降、放射性肠炎及骨髓抑制的发生率明显低于对照组,差异具有统计学意义(P<0.05)。结论:采用IMRT联合顺铂治疗宫颈癌患者的疗效优于采用单一的IMRT治疗的患者,并减少治疗后的不良反应,值得临床推广采纳。 展开更多
关键词 宫颈癌 顺铂 临床疗效 调强放射疗法
下载PDF
鼻咽鳞癌CNE1、CNE2细胞系IMRT模式离体照射生物效应研究 被引量:2
7
作者 王志 邬蒙 +2 位作者 何秀琴 王小平 陈文学 《实用癌症杂志》 2008年第3期248-251,共4页
目的观察适形调强放射治疗(IMRT)模式单次剂量输出时间延长对鼻咽鳞癌CNE1、CNE2细胞放射生物效应的影响,以便为临床制定个体化IMRT计划提供一些理论依据。方法分别急速照射指数生长期的CNE1细胞、CNE2细胞9个剂量点,采用克隆分析法计... 目的观察适形调强放射治疗(IMRT)模式单次剂量输出时间延长对鼻咽鳞癌CNE1、CNE2细胞放射生物效应的影响,以便为临床制定个体化IMRT计划提供一些理论依据。方法分别急速照射指数生长期的CNE1细胞、CNE2细胞9个剂量点,采用克隆分析法计算细胞存活分数,运用单靶多击和线性二次方程数学(LQ)模型拟合曲线,求出2种细胞放射生物学参数。将指数生长期的CNE-1细胞、CNE-2细胞分成3个组:①EBRT组;②IMRT模式15min照射组;③IMRT模式30min照射组(单次剂量输出时间延长至15min和30min)。每组照射总剂量为6Gy,1次/天,2Gy/次,连续照射3天,采用克隆分析法计算细胞的存活分数。结果急速照射1次后的各点细胞存活率以单靶多击模型拟合曲线,得出CNE1细胞D0值为0.88Gy,Dq值为0.47Gy,N值为3.5,CNE2细胞D0值0.60Gy,Dq值为0.36Gy,N值为4.0;以LQ模型拟合曲线,得出CNE1细胞α值为0.16Gy-1,β值为0.089Gy-2,α/β值为1.8Gy,CNE2细胞α值为0.97Gy-1,β值为0.086Gy-2,α/β值为11.3Gy。CNE1细胞EBRT组细胞存活率为7.21%,IMRT模式15min照射组为8.85%,IMRT模式30min照射组为9.92%,IMRT模式组随着单次剂量时间延长到15min和30min,细胞存活率较EBRT组明显增加,t检验有显著差异(P<0.05)。CNE2细胞EBRT组为0.190%,IMRT模式15min照射组为0.204%,IMRT模式30min照射组细胞存活率为0.207%,t检验无显著差异(P>0.05)。结论鼻咽高分化鳞癌CNE1细胞具有较低的α/β值及较大的D0、Dq值,相对于鼻咽低分化鳞癌CNE2细胞具有较强的亚致死性修复(SLDR)能力。SLDR能力在单次剂量延长的放疗中对细胞存活起重要作用。IMRT模式单次剂量输出时间延长将使CNE1细胞存活率增加明显,而CNE2细胞增加不明显。 展开更多
关键词 适形调强放疗 生物效应 细胞存活曲线 亚致死性损伤修复
下载PDF
ExacTrac图像引导系统在鼻咽癌IMRT中的应用 被引量:6
8
作者 周军 李东春 +3 位作者 万久庆 罗灿 金俊余 李光辉 《临床肿瘤学杂志》 CAS 北大核心 2020年第4期334-338,共5页
目的探讨ExacTrac图像引导系统在鼻咽癌调强放射治疗(IMRT)摆位误差全程管控中的应用价值。方法收集2018年3月至2018年8月接受IMRT的30例鼻咽癌患者,采用ExacTrac图像引导系统全程实施图像引导放射治疗(IGRT),分析左右、头脚、腹背3个... 目的探讨ExacTrac图像引导系统在鼻咽癌调强放射治疗(IMRT)摆位误差全程管控中的应用价值。方法收集2018年3月至2018年8月接受IMRT的30例鼻咽癌患者,采用ExacTrac图像引导系统全程实施图像引导放射治疗(IGRT),分析左右、头脚、腹背3个平移方向及绕此3个方向旋转角度上的6D误差。结果ExacTrac图像引导系统校正前左右、头脚、腹背3个平移方向的误差值分别为(0.11±1.52)mm、(1.45±2.40)mm和(0.67±1.65)mm,绕此3个方向的旋转误差值分别为(-0.16±1.12)°、(0.32±1.59)°、(-0.38±1.12)°。校正后,左右、头脚、腹背3个平移方向的误差值分别为(-0.04±0.46)mm、(0±0.42)mm和(0.03±0.54)mm,绕此3个方向的旋转误差值分别为(-0.03±0.25)°、(0.01±0.23)°和(0.01±0.28)°。校正后在左右、头脚、腹背3个平移方向及绕此3个方向的旋转角度上,≤1 mm或1°的误差概率分别为99%、100%、99%、100%、100%和100%。2 mm或2°的误差概率在左右平移方向为1%,腹背平移方向为1%,其余方向为0。≥3 mm或3°的误差概率均为0。ExacTrac图像引导系统校正前后6D方向摆位误差的差异有统计学意义(P<0.05)。结论鼻咽癌患者在实施每分次IMRT的过程中行IGRT非常必要,应用ExacTrac图像引导系统可以明显校正摆位误差,提高放疗精准性。 展开更多
关键词 鼻咽癌 调强放射治疗(imrt) ExacTrac图像引导系统 图像引导放射治疗(IGRT) 摆位误差
下载PDF
SIB-IMRT与常规调强放射治疗食管癌的效果研究 被引量:4
9
作者 华传礼 王增才 《武警后勤学院学报(医学版)》 CAS 2021年第9期47-48,51,共3页
【目的】探讨同步整合加量调强放射治疗(SIB-IMRT)与常规调强放射治疗食管癌的效果。【方法】选取60例食管癌患者为研究对象,按随机数字表法将其分为实验组(n=19)和对照组(n=41),实验组予以SIB-IMRT治疗,对照组予以常规调强放射治疗。... 【目的】探讨同步整合加量调强放射治疗(SIB-IMRT)与常规调强放射治疗食管癌的效果。【方法】选取60例食管癌患者为研究对象,按随机数字表法将其分为实验组(n=19)和对照组(n=41),实验组予以SIB-IMRT治疗,对照组予以常规调强放射治疗。对比两组临床缓解情况、放射损伤情况、放射区域放射参数。【结果】治疗后,实验组总缓解率明显高于对照组(97.74%vs 63.41%)(P<0.05);实验组放射损伤情况总占比显著低于对照组放射损伤情况总占比(21.05%vs 51.22%)(P<0.05);实验组放射区域D95高于对照组,而放射区域V105及HI均低于对照组(P<0.05)。【结论】SIB-IMRT与常规调强放射治疗食管癌患者均有一定疗效,但前者的临床疗效明显优于后者,且毒副反应小,安全性较高,SIB-IMRT可作为治疗食管癌的优选放疗手段。 展开更多
关键词 SIB-imrt 常规调强放射治疗 食管癌 临床效果
下载PDF
The Dosimetric Effects of Different Beam Energy on Physical Dose Distributions in IMRT Based on Analysis of Physical Indices
10
作者 Ismail Eldesoky Ehab M. Attalla Wael M. Elshemey 《Journal of Cancer Therapy》 2013年第11期33-43,共11页
This work aimed at evaluating the effect of 6- and 10-MV photon energies on intensity-modulated radiation therapy (IMRT) treatment plan outcome in different selected diagnostic cases. For such purpose, 19 patients, wi... This work aimed at evaluating the effect of 6- and 10-MV photon energies on intensity-modulated radiation therapy (IMRT) treatment plan outcome in different selected diagnostic cases. For such purpose, 19 patients, with different types of non CNS solid tumers, were selected. Clinical step-and-shoot IMRT treatment plans were designed for delivery on a Siemens Oncor accelerator with 82 leafs;multi-leaf collimators (MLCs). To ensure that the similarity or difference among the plans is due to energy alone, the same optimization constraints were applied for both energy plans. All the parameters like beam angles, number of beams, were kept constant to achieve the same clinical objectives. The Comparative evaluation was based on dose-volumetric analysis of both energy IMRT plans. Both qualitative and quantitative methods were used. Several physical indices for Planning Target Volume (PTV), the relevant Organs at Risk (OARs) as mean dose (Dmean), maximum dose (Dmax), 95% dose (D95), integral dose, total number of segments, and the number of MU were applied. Homogeneity index and conformation number were two other evaluation parameters that were considered in this study. Collectively, the use of 6 MV photons was dosimetrically comparable with 10 MV photons in terms of target coverage, homogeneity, conformity, and OAR savings. While 10-MV plans showed a significant reduction in the number of MUs that varied between 4.2% and 16.6% (P-value = 0.0001) for the different cases compared to 6-MV. The percentage volumes of each patient receiving 2 Gy and 5 Gy were compared for the two energies. The general trend was that 6-MV plans had the highest percentage volume, (P-value = 0.0001, P-value = 0.006) respectively. 10-MV beams actually decreased the integral dose (from average 183.27 ± 152.38 Gy-Kg to 178.08 ± 147.71 Gy-Kg, P-value = 0.004) compared with 6-MV. In general, comparison of the above parameters showed statistically significant differences between 6-MV and 10-MV groups. Based on the present results, the 10-MV is the optimal energy for IMRT, regardless of the concerns about a potential risk of radiation-induced malignancies. It is recommended that the choice to treat at 10 MV be taken as a risk vs. benefit as the clinical significance remains to be determined on case by case basis. 展开更多
关键词 6- and 10-MV Photon ENERGIES intensity-MODULATED radiation therapy (imrt) Dose-Volumetric ANALYSIS
下载PDF
混合放疗技术在全脑放疗中的应用
11
作者 高层层 杨磊 《中国医疗设备》 2024年第9期43-47,61,共6页
目的比较混合放射治疗技术与调强放射治疗(Intensity Modulated Radiation Therapy,IMRT)、容积调强放射治疗(Volumetric Modulated Arc Therapy,VMAT)、三维适形放射治疗(Three dimensional Conformal Radiation Therapy,3DCRT)在全脑... 目的比较混合放射治疗技术与调强放射治疗(Intensity Modulated Radiation Therapy,IMRT)、容积调强放射治疗(Volumetric Modulated Arc Therapy,VMAT)、三维适形放射治疗(Three dimensional Conformal Radiation Therapy,3DCRT)在全脑放疗中的剂量学差异,研究混合放疗技术在全脑放疗的可行性。方法选取25例需要全脑放疗的患者为研究对象,分别设计3DCRT计划、基于3DCRT、IMRT技术的混合计划(Hybrid-IMRT)、基于3DCRT、VMAT技术的混合计划(Hybrid-VMAT)、IMRT计划、VMAT计划。Hybrid-IMRT计划与IMRT计划、Hybrid-VMAT计划与VMAT计划均采用相同的优化参数,2个混合计划3DCRT提供60%的处方剂量(2400 cGy/20 F),IMRT或VMAT部分提供剩余40%的处方剂量(1600 cGy/20 F)。比较5组计划的靶区均匀性指数、适形度指数、靶区最大剂量、机器跳数、危及器官(晶体、眼球、视神经、视交叉、脑干)的最大剂量。结果5种计划各项指标均满足临床需求。Hybrid-IMRT、Hybrid-VMAT计划靶区均匀度、靶区剂量最大点和晶体、视交叉、脑干的受量优于IMRT、VMAT计划,且差异有统计学意义(P<0.05);HybridIMRT、Hybrid-VMAT计划靶区适形度和眼球受量相对IMRT、VMAT计划差异有统计学意义(P<0.05)。Hybrid-IMRT、Hybrid-VMAT计划的机器跳数分别比IMRT、VMAT计划减少60%和10%(P<0.05)。结论Hybrid-IMRT、Hybrid-VMAT计划的各项参数均满足临床治疗要求,其靶区均匀度更好,治疗时间更短,对距离靶区较远和靶区内部的危及器官保护更好,因此混合放射治疗技术可以应用于全脑放疗中。 展开更多
关键词 全脑放疗 混合放疗技术 剂量学 调强放疗技术 容积旋转调强放疗技术
下载PDF
适形调强放射治疗联合经动脉化疗栓塞治疗晚期肝细胞癌的预后研究
12
作者 王鸿飞 杨柳 +1 位作者 周解平 吴爱东 《中国医学装备》 2024年第4期13-17,共5页
目的:探讨适形调强放射治疗(IMRT)联合经动脉化疗栓塞(TACE)治疗晚期肝细胞癌(HCC)的疗效及预后。方法:回顾性分析2015年12月至2021年12月安徽省肿瘤医院收治的114例晚期HCC患者,所有患者均采用IMRT联合TACE治疗,使用单因素及多因素Cox... 目的:探讨适形调强放射治疗(IMRT)联合经动脉化疗栓塞(TACE)治疗晚期肝细胞癌(HCC)的疗效及预后。方法:回顾性分析2015年12月至2021年12月安徽省肿瘤医院收治的114例晚期HCC患者,所有患者均采用IMRT联合TACE治疗,使用单因素及多因素Cox生存分析确定影响患者生存期的独立预测影响因素。结果:经IMRT联合TACE治疗后所有患者的总有效率(完全缓解+部分缓解)为60.5%(69/114)。多因素分析发现肿瘤直径较大、高美国东部肿瘤协作组(ECOG)评分、Ⅲ~Ⅳ型门静脉癌栓(PVTT)、肝炎治疗和白细胞计数升高均是影响患者生存期的独立预测影响因素(HR=1.085、2.627、1.891、0.531、1.134,P<0.05)。结论:肿瘤Ⅲ~Ⅳ型PVTT和肿瘤直径较大对患者的生存有很大影响;而患者身体状态、肝炎治疗及全身炎症也是影响患者生存的重要因素。采用IMRT联合TACE治疗晚期HCC具有较好的治疗的效果,但应充分考虑预后生存影响因素。 展开更多
关键词 肝细胞癌(HCC) 癌栓 经动脉化疗栓塞(TACE) 三维适形调强放射治疗(3D-imrt)
下载PDF
ⅡB期宫颈癌全盆盒式放疗与调强放疗的剂量学比较及临床观察 被引量:7
13
作者 阮莎莎 伍钢 +2 位作者 丁乾 宋颖秋 李贵玲 《临床肿瘤学杂志》 CAS 2014年第3期235-239,共5页
目的:探讨ⅡB期宫颈癌全盆盒式放疗与不同射野调强放疗( IMRT)的剂量学差异,并比较临床疗效及急性毒副反应。方法收集10例ⅡB期宫颈癌患者进行CT模拟定位,每例患者均设计全盆盒式放疗计划和3种不同设野的IMRT计划,评估靶区及危及... 目的:探讨ⅡB期宫颈癌全盆盒式放疗与不同射野调强放疗( IMRT)的剂量学差异,并比较临床疗效及急性毒副反应。方法收集10例ⅡB期宫颈癌患者进行CT模拟定位,每例患者均设计全盆盒式放疗计划和3种不同设野的IMRT计划,评估靶区及危及器官的剂量。回顾性分析2011年1月至2012年10月收治的77例ⅡB期宫颈癌初诊患者,根据患者意愿分为盒式放疗组(n=33)及IMRT组(n=44),分别采用盒式放疗(46~50Gy)或9野IMRT(56Gy/28f)结合后装腔内放疗并同步顺铂(25mg/m2静滴,每周1次,共5~6次)化疗,比较近期疗效及急性毒副反应。结果3种不同射野IMRT计划中计划靶区体积(PTV)的靶区均匀性(HI)和适形性(CI)均优于盒式放疗计划(P<0.05),膀胱V30、V40、小肠V20、V30、V40、Dmean、D50及直肠V30、V40、Dmean、D50均低于盒式放疗计划( P<0.05);3种IMRT之间PTV的HI及CI的差异无统计学意义,随着照射野的增多,膀胱V30、V40、Dmean、D50及直肠V20、V30、V40、Dmean、D50逐渐下降,其中膀胱V30、V40差异有统计学意义( P<0.05)。盒式放疗组与IMRT组完全缓解率分别为84.8%及88.6%( P>0.05)。 IMRT组放射性肠炎、放射性膀胱炎的发生率低于盒式放疗组( P<0.05),两组均出现不同程度骨髓抑制,但差异无统计学意义( P>0.05)。结论 IMRT计划在剂量学上显示了保护危及器官的优势,在临床疗效上9野IMRT与盒式放疗的近期疗效相当,但能明显降低急性毒副反应的发生率,推荐ⅡB期宫颈癌患者外照射行9野IMRT。 展开更多
关键词 子宫颈癌 盒式放疗 调强放疗 剂量学 intensity modulated radiation therapy( imrt)
下载PDF
局部晚期非小细胞肺癌同步放化疗并序贯化疗与单纯序贯放化疗的对比研究 被引量:34
14
作者 余建云 李林均 +3 位作者 陈萍 张军 许涛 程雄飞 《肿瘤防治研究》 CAS CSCD 北大核心 2015年第6期606-609,共4页
目的观察局部晚期非小细胞肺癌(NSCLC)接受调强放疗(IMRT)联合同步吉西他滨和卡铂方案(GC)化疗与序贯放化疗的近、远期疗效和不良反应。方法回顾性分析不能进行手术治疗和拒绝手术治疗的局部晚期NSCLC患者65例,其中同步放化疗并序贯化... 目的观察局部晚期非小细胞肺癌(NSCLC)接受调强放疗(IMRT)联合同步吉西他滨和卡铂方案(GC)化疗与序贯放化疗的近、远期疗效和不良反应。方法回顾性分析不能进行手术治疗和拒绝手术治疗的局部晚期NSCLC患者65例,其中同步放化疗并序贯化疗组给予IMRT同步联合GC治疗者32例,单纯序贯放化疗组为33例给予IMRT后序贯GC治疗。通过统计分析比较两组之间的近期有效率、远期生存率和不良反应。结果两组均完成治疗,随访率100%,同步放化疗并序贯化疗组近期有效率为75%,单纯序贯放化疗组为66.7%,两组比较差异有统计学意义(P<0.05)。两组1、3年生存率相比较,同步放化疗并序贯化疗组为68.2%、20.5%;单纯序贯放化疗组为50.1%、11.3%;同步放化疗并序贯化疗组明显优于单纯序贯放化疗组(P<0.05)。两组不良反应情况对比,差异无统计学意义(P>0.05)。结论 IMRT同步联合GC方案并序贯化疗治疗局部晚期NSCLC,可以提高患者的远期生存率且不良反应可耐受。 展开更多
关键词 非小细胞肺癌 调强放疗 吉西他滨 卡铂
下载PDF
螺旋断层放疗与常规调强放疗在乳腺癌保乳术后同步推量中的剂量学比较 被引量:19
15
作者 李益坤 刘海 +4 位作者 王晓萍 杭霞瑜 曾波 甘叶敏 李帆 《临床肿瘤学杂志》 CAS 2013年第7期648-651,共4页
目的比较乳腺癌保乳术后同步推量放疗中应用常规调强放疗(IMRT)及螺旋断层放疗(HT)剂量分布的差异,为HT在乳腺癌保乳术后的临床应用提供依据。方法随机选择10例乳腺癌保乳术后患者,统一勾画计划靶区(PTV)与原发灶靶区(PGTV)并导入HT计... 目的比较乳腺癌保乳术后同步推量放疗中应用常规调强放疗(IMRT)及螺旋断层放疗(HT)剂量分布的差异,为HT在乳腺癌保乳术后的临床应用提供依据。方法随机选择10例乳腺癌保乳术后患者,统一勾画计划靶区(PTV)与原发灶靶区(PGTV)并导入HT计划系统及瓦里安Eclipse计划系统,分别设计IMRT和HT计划,处方剂量均为PTV 50Gy/25f、PGTV 60Gy/25f,通过比较靶区剂量适形度、均匀性以及心肺受照剂量来评估IMRT与HT的优劣。结果 HT计划中靶区剂量的均匀性、适形度明显优于IMRT(P<0.05),患侧肺V5、V10、V20、V30及肺平均剂量均明显低于IMRT(P<0.05),但健侧肺V5增加;心脏剂量明显降低(P<0.05)。结论对于乳腺癌保乳术后同步推量放疗,HT与IMRT计划都可以满足临床剂量的要求,但HT计划在剂量学方面相对于IMRT计划具有优势,可以显著降低对正常器官的毒副作用。 展开更多
关键词 螺旋断层放疗 剂量学 调强放疗 乳腺癌
下载PDF
图像引导下的大分割调强放射治疗骨转移癌临床研究 被引量:10
16
作者 刘志凯 杨波 +2 位作者 孙显松 王欣海 张福泉 《中国疼痛医学杂志》 CAS CSCD 北大核心 2014年第8期576-579,共4页
目的:本研究采用图像引导下的大分割调强放疗技术,治疗癌症骨转移.评价该方案的可行性、安全性及有效率.方法:选取我科2011~2012年收治椎体骨转移患者21名,骨转移灶28处,予肿瘤所在椎体24 Gy/6次,同步予肿瘤加量至36 Gy/6次,限制脊髓... 目的:本研究采用图像引导下的大分割调强放疗技术,治疗癌症骨转移.评价该方案的可行性、安全性及有效率.方法:选取我科2011~2012年收治椎体骨转移患者21名,骨转移灶28处,予肿瘤所在椎体24 Gy/6次,同步予肿瘤加量至36 Gy/6次,限制脊髓D0.1ml小于25 Gy.结果:病灶疗前疼痛评分7.54±0.84分;疗后即刻评分4.00±1.59分,缓解程度47.38%±17.75%;疗后1月评分2.46±2.01分,缓解程度67.54%±24.84%;疗后3月评分2.07±1.92分,缓解程度72.92%±24.09%.治疗后即刻、1月、3月疼痛评分较疗前均有显著差异(P<0.01).疗后即刻有效率为57.14%(16/28),1月有效率为82.14%(23/28),3月有效率为82.14%(23/28).l例患者出现Ⅱ度食管副反应,无患者出现神经系统副反应.结论:本研究表明图像引导下的大分割调强放射治疗骨转移癌是安全有效的治疗选择,其长期疗效尚需进一步研究. 展开更多
关键词 骨转移癌 调强放疗 图像引导放射治疗 大分割放疗 疼痛
下载PDF
硅胶产生的空腔对乳腺癌根治术后调强放射治疗的剂量学影响 被引量:12
17
作者 刘婷婷 刘锐锋 +8 位作者 欧阳水根 魏玺仪 刘志强 张明 陶娜 牛瑞军 郭晴 陶发利 杨文翠 《辐射研究与辐射工艺学报》 CAS CSCD 2020年第3期39-45,共7页
为提高硅胶填充物(Bolus)使用的可靠性,对比4种不同厚度Bolus设置方式产生的空腔大小对乳腺癌根治术后调强放疗的剂量学影响。根据空腔大小范围制定3套适形调强放射治疗(Intensity-modulated radiation therapy,IMRT)计划方案Plan1(空... 为提高硅胶填充物(Bolus)使用的可靠性,对比4种不同厚度Bolus设置方式产生的空腔大小对乳腺癌根治术后调强放疗的剂量学影响。根据空腔大小范围制定3套适形调强放射治疗(Intensity-modulated radiation therapy,IMRT)计划方案Plan1(空腔大于10 mm)、Plan2(空腔大于5 mm且小于10 mm)、Plan3(空腔小于2 mm),并与常规计划设计下Bolus服帖在皮肤上无空腔的IMRT(Plan4)进行剂量对比,分析剂量–体积直方图(DVH)与三维剂量分布图,采用统计软件包(SPSS)对数据进行统计分析,评价靶区和危及器官的剂量分布差异。统计分析得知,4种方案所有靶区剂量学指标均满足处方剂量要求,且无统计学差异(p>0.05);但剂量分布图显示,Plan1与Plan2空腔附近靶区聚集不等范围的高剂量区及近皮肤剂量不足区,Plan1程度较Plan2大;DVH结果显示,Plan3与Plan4能够更好降低食管平均剂量Dmean、气管平均剂量Dmean、患侧肺接受≥30 Gy照射的体积百分比V30,以及辅助结构Ring接受≥40 Gy、45 Gy照射体积百分比V40、V45,且差异均有统计学差异(p<0.05)。对比得知,小空腔(小于2 mm)能够减少靶区内的冷点与热点,降低危及器官受量,更接近理想计划方案。Plan3采用2 mm叠加3 mm的方式,将大空腔缩小至2 mm以下,既能满足Bolus的补偿作用,又能避免Bolus物理特性引起的剂量学误差,保证治疗质量。 展开更多
关键词 硅胶 空腔 乳腺癌 调强放射治疗 剂量学
下载PDF
胸腺瘤术后调强放射治疗和容积弧形调强放射治疗剂量学分析 被引量:8
18
作者 刘路 杨瑞杰 +4 位作者 李金娜 姜伟娟 江萍 孟娜 王俊杰 《生物医学工程与临床》 CAS 2014年第1期22-26,共5页
目的研究在胸腺瘤术后放射治疗中分别采取调强放射治疗(IMRT)技术和容积弧形调强放射治疗(VMAT)技术的剂量学特点,并进一步指导胸腺瘤的放射治疗计划设计。方法选择2012年9月至2013年2月10例行放射治疗的胸腺瘤术后的患者,其中男... 目的研究在胸腺瘤术后放射治疗中分别采取调强放射治疗(IMRT)技术和容积弧形调强放射治疗(VMAT)技术的剂量学特点,并进一步指导胸腺瘤的放射治疗计划设计。方法选择2012年9月至2013年2月10例行放射治疗的胸腺瘤术后的患者,其中男性7例,女性3例:年龄38-63岁。中位年龄56岁。分别在治疗计划系统(TPS)上勾画大体肿瘤靶区(GTV)、临床肿瘤靶区(CTV)和计划肿瘤靶区(P11V)。术后胸腺瘤放射治疗处方剂量为5000cGy,分别采取IMRT和VMAT技术设计治疗计划,由TPS得到正常组织、危及器官的受累剂量和靶区与处方剂量分布的一致性,并列表比较。结果IMRT的计划靶区的适形指数(CI)和均匀性指数(HI)分别为0.78和1.11,VMAT计划的CI和HI为O.87和1.07。VMAT相比较IMRT在靶区剂量的适形性和不均匀性均稍优于IMRT(P=0.012,P=0.047)。在并型器官如肺组织的低剂量体积(V5、V10)上,VMAT比IMRT对肺组织产生更大的损伤,分别为69.26%和64.68%(P〈0.05)、47.52%和44.93%(P〈0.05)。对于脊髓的最大剂量.VMAT为20.51Gy,IMRT为31.66Gy;心脏的V40和V50,VMAT和IMRT相应的值为10.64%和15.08%、4.39%和8.15%;食管的最大剂量,VMAT和IMRT相应的值为38.67Gv和44-30Gy。可以看出VMAT在保护正常器官方面均优于IMRT。结论对于肿瘤靶区偏中心、体积较小、压迫正常肺组织较小的患者,采取IMRT的治疗方式可以更好地保护正常和危及器官:但是对于肿瘤靶区体积较大、中心型、压迫正常肺组织较大的患者,采取照射范围较大的VMAT更加有优势。 展开更多
关键词 胸腺瘤 放射治疗 静态调强放射治疗 旋转调强放射治疗 剂量学
下载PDF
局部晚期鼻咽癌新辅助化疗研究进展 被引量:23
19
作者 万刚 徐鹏 郎锦义 《肿瘤防治研究》 CAS CSCD 北大核心 2016年第2期93-99,共7页
鼻咽癌的治疗手段是以放射治疗为主的综合治疗,随着调强放疗等精确放疗技术和放化综合治疗的广泛应用,初治鼻咽的局部控制率已经提高到90%以上。为了提高局部晚期鼻咽癌的治愈率、降低复发或远处转移,放疗与化疗的结合一直是学者们研究... 鼻咽癌的治疗手段是以放射治疗为主的综合治疗,随着调强放疗等精确放疗技术和放化综合治疗的广泛应用,初治鼻咽的局部控制率已经提高到90%以上。为了提高局部晚期鼻咽癌的治愈率、降低复发或远处转移,放疗与化疗的结合一直是学者们研究热点。由于同步放化疗已成为局部晚期鼻咽的标准治疗,新辅助化疗是鼻咽癌综合治疗研究的热点,新辅助联合同步放化疗是否获益一直存在争议。同时调强放疗的大量应用,同步化疗的地位受到怀疑,新辅助化疗在调强时代能否替代同步化疗及新辅助化疗后靶区应如何勾画值得进一步研究。因此,本文就新辅助化疗治疗局部晚期鼻咽癌的进展进行综述。 展开更多
关键词 新辅助化疗 鼻咽癌 同步化疗 调强放疗
下载PDF
128例初治鼻咽癌调强适形放疗临床分析 被引量:10
20
作者 王仁生 韦波 +1 位作者 黄素宁 阮长利 《肿瘤防治研究》 CAS CSCD 北大核心 2010年第5期570-574,共5页
目的分析调强适形放疗(intensity modulated radiation therapy,I MRT)治疗初治鼻咽癌的临床疗效。方法鼻咽癌I MRT初治患者128例,按1992年福州分期标准,Ⅰ期2例,Ⅱ期19例,Ⅲ期58例,Ⅳa期49例。鼻咽大体肿瘤体积(GTVnx)处方剂量为(... 目的分析调强适形放疗(intensity modulated radiation therapy,I MRT)治疗初治鼻咽癌的临床疗效。方法鼻咽癌I MRT初治患者128例,按1992年福州分期标准,Ⅰ期2例,Ⅱ期19例,Ⅲ期58例,Ⅳa期49例。鼻咽大体肿瘤体积(GTVnx)处方剂量为(70-74)Gy分30次,颈部淋巴结(GTVnd)处方剂量为(68-70)Gy分30次,临床靶体积1(CTV1)(60-64)Gy分30次,临床靶体积2(CTV2)(50-54)Gy分30次。采用Kaplan-Meier法进行生存分析和局部控制率计算,Log-rank检验组间差异。结果中位随访时间12月(6-24月),1、2年总生存率分别为100%、96.9%,1、2年无远处转移生存率分别为92.2%、88.3%,1、2年局部控制率分别为96.1%和93.8%。N分期是影响有无远处转移生存率的最重要预后因素(P=0.04)。最严重的急性不良反应是放射性黏膜炎,Ⅰ-Ⅳ级分别为38.8%、48.4%、7.8%、0。晚期不良反应主要表现为口干,Ⅰ级67.2%,Ⅱ级19.5%。结论鼻咽癌I MRT靶区剂量高,周围正常组织受量小,不良反应轻,是一种治疗鼻咽癌的有效方法。治疗失败最主要的原因是远处转移,其发生率与颈淋巴结转密切相关。 展开更多
关键词 鼻咽癌 调强适形放疗 预后
下载PDF