对2007年版《IEEE Guide for AC Generator Protection》中失磁保护定值整定的几个问题提出不同意见。明确指出:发电机失磁故障必有滑差(s),其平均异步阻抗Xd(js)Xd(s=0),失磁保护中的阻抗元件下端定值为-Xd,已有足够余度,不应该是-(1.1...对2007年版《IEEE Guide for AC Generator Protection》中失磁保护定值整定的几个问题提出不同意见。明确指出:发电机失磁故障必有滑差(s),其平均异步阻抗Xd(js)Xd(s=0),失磁保护中的阻抗元件下端定值为-Xd,已有足够余度,不应该是-(1.1~1.25)Xd;在P-Q坐标与R-X坐标的转换公式中,U值应由"失磁保护动作滞后于低励限制线(UEL)"原则来确定,不应主观选择0.95UN。展开更多
This paper proposed a new diagnosis model for the stator inter-turn short circuit fault in synchronous generators.Different from the past methods focused on the current or voltage signals to diagnose the electrical fa...This paper proposed a new diagnosis model for the stator inter-turn short circuit fault in synchronous generators.Different from the past methods focused on the current or voltage signals to diagnose the electrical fault,the sta-tor vibration signal analysis based on ACMD(adaptive chirp mode decomposition)and DEO3S(demodulation energy operator of symmetrical differencing)was adopted to extract the fault feature.Firstly,FT(Fourier trans-form)is applied to the vibration signal to obtain the instantaneous frequency,and PE(permutation entropy)is calculated to select the proper weighting coefficients.Then,the signal is decomposed by ACMD,with the instan-taneous frequency and weighting coefficient acquired in the former step to obtain the optimal mode.Finally,DEO3S is operated to get the envelope spectrum which is able to strengthen the characteristic frequencies of the stator inter-turn short circuit fault.The study on the simulating signal and the real experiment data indicates the effectiveness of the proposed method for the stator inter-turn short circuit fault in synchronous generators.In addition,the comparison with other methods shows the superiority of the proposed model.展开更多
Distributed generators now is widely used in electrical power networks, in some cases it works seasonally, and some types works at special weather conditions like photo voltaic systems and wind energy, and due to this...Distributed generators now is widely used in electrical power networks, in some cases it works seasonally, and some types works at special weather conditions like photo voltaic systems and wind energy, and due to this continuous changes in generation condition, the fault current level in network will be affected, this changes in fault current level will affect in the coordination between protection relays and to keep the coordination at right way, an adaptive protection system is required that can adaptive its setting according to generation changes, the fault current level in each case is evaluated using ETAP software, and the required relay setting in each case is also evaluated using Grey Wolf Optimizer (GWO) algorithm, and to select suitable setting which required in each condition, to select the active setting group of protection relay according to generation capacity, central protection unite can be used, and to improve protection stability and minimizing relays tripping time, a proposed method for selecting suitable backup relay is used, which leads to decrease relays tripping time and increase system stability, output settings for relays in all cases achieved our constrains.展开更多
With the increase in the use of electronic devices in many different environments,a need has arisen for an easily implemented method for the rapid,sensitive detection of liquids in the vicinity of electronic component...With the increase in the use of electronic devices in many different environments,a need has arisen for an easily implemented method for the rapid,sensitive detection of liquids in the vicinity of electronic components.In this work,a high-performance power generator that combines carbon nanoparticles and TiO2 nanowires has been fabricated by sequential electrophoretic deposition(EPD).The opencircuit voltage and short-circuit current of a single generator are found to exceed 0.7 V and 100μA when 6μL of water was applied.The generator is also found to have a stable and reproducible response to other liquids.An output voltage of 0.3 V was obtained after 244,876,931,and 184μs,on exposure of the generator to 6μL of water,ethanol,acetone,and methanol,respectively.The fast response time and high sensitivity to liquids show that the device has great potential for the detection of small quantities of liquid.In addition,the simple easily implemented sequential EPD method ensures the high mechanical strength of the device.This compact,reliable device provides a new method for the sensitive,rapid detection of extraneous liquids before they can impact the performance of electronic circuits,particularly those on printed circuit board.展开更多
Nowadays wind energy is the fastest growing renewable energy resource in the world.The problems of integrating wind farms are caused by changes of wind speed during a day.Moreover,the behaviors of wind turbines equipp...Nowadays wind energy is the fastest growing renewable energy resource in the world.The problems of integrating wind farms are caused by changes of wind speed during a day.Moreover,the behaviors of wind turbines equipped with doubly-fed induction generators differ fundamentally from synchronous generators.Therefore,more considerations are needed to analyze the performances of the distance protection relays.The protection of a wind farm with distance relay is inspected.By changing the conditions of the wind farm,the characteristics of the distance relay are studied.展开更多
Generator control system decides whether the generator can work as usual or not, as well as its stability of performance. Both types of generators control system composed of the transistor and DSP are sensitive to out...Generator control system decides whether the generator can work as usual or not, as well as its stability of performance. Both types of generators control system composed of the transistor and DSP are sensitive to outward electromagnetic interference, directly related to the generator performance. In this text, we first analyze the electromagnetic interference threat generator control system of transistor type may face, then design a electromagnetic protection plan for the intake, the panel and the sense organ. This work is of great significance in improving its electromagnetic protection ability and stability of performance.展开更多
Domestic generators will be used in ThreeGorges Hydropower Station in the future, this paper introduces the corresponding protection system design for them, including the special requirements and the configuration of ...Domestic generators will be used in ThreeGorges Hydropower Station in the future, this paper introduces the corresponding protection system design for them, including the special requirements and the configuration of the protection system. To increase compactness and reduce relay cost, the protection equipment will adopt the dual-system structure with a manager system and several subsystems considering the protection funcition redundancy. Some special function principles and methods, the communications, the protection modules and the managing system are also discussed in detail.展开更多
Fault Ride-Through (FRT) capabilities set up according to the grid codes may affect the performance of related protective elements during fault periods. Therefore, in this paper the coordination between the FRT capa...Fault Ride-Through (FRT) capabilities set up according to the grid codes may affect the performance of related protective elements during fault periods. Therefore, in this paper the coordination between the FRT capability and over-current protection of DFIG Wind Generators in MV networks is investigated. Simulation test cases using MATLAB-Simulink are implemented on a 365-MW wind farm in AL-Zaafarana, Egypt. The simulation results show the influence of the FRT capability on the protective relaying coordination in wind farms, showing that the FRT may work in situations where is were expected not to work, and then disabling the over-current protection, which should have worked in this situation.展开更多
Synchronous generators are important components of power systems and are necessary to maintain its normal and stable operation.To perform the fault diagnosis of mild inter-turn short circuit in the excitation winding ...Synchronous generators are important components of power systems and are necessary to maintain its normal and stable operation.To perform the fault diagnosis of mild inter-turn short circuit in the excitation winding of a synchronous generator,a gate recurrent unit-convolutional neural network(GRU-CNN)model whose structural parameters were determined by improved particle swarm optimization(IPSO)is proposed.The outputs of the model are the excitation current and reactive power.The total offset distance,which is the fusion of the offset distance of the excitation current and offset distance of the reactive power,was selected as the fault judgment criterion.The fusion weights of the excitation current and reactive power were determined using the anti-entropy weighting method.The fault-warning threshold and fault-warning ratio were set according to the normal total offset distance,and the fault warning time was set according to the actual situation.The fault-warning time and fault-warning ratio were used to avoid misdiagnosis.The proposed method was verified experimentally.展开更多
<div style="text-align:justify;"> Generalized S-transform is a time-frequency analysis method which has higher resolution than S-transform. It can precisely extract the time-amplitude characteristics o...<div style="text-align:justify;"> Generalized S-transform is a time-frequency analysis method which has higher resolution than S-transform. It can precisely extract the time-amplitude characteristics of different frequency components in the signal. In this paper, a novel protection method for VSC-HVDC (Voltage source converter based high voltage DC) based on Generalized S-transform is proposed. Firstly, extracting frequency component of fault current by Generalized S-transform and using mutation point of high frequency to determine the fault time. Secondly, using the zero-frequency component of fault current to eliminate disturbances. Finally, the polarity of sudden change currents in the two terminals is employed to discriminate the internal and external faults. Simulations in PSCAD/EMTDC and MATLAB show that the proposed method can distinguish faults accurately and effectively. </div>展开更多
The use of non-power frequency components for protection measurements in an area that has received relatively little attention. Although work on the use of switched stack tuners has been reported for fault detection, ...The use of non-power frequency components for protection measurements in an area that has received relatively little attention. Although work on the use of switched stack tuners has been reported for fault detection, the sensitivity of switched arrangements is limited by scnsitivity of directional detectors for switching purposes. This paper presents an alternative non-switching scheme which is relatively simple.A simplified typical 400kV system with the line trap, stack tuner, coupling capacitor and bus capacitance to earth is considered. Fault studies by using the EMTP have been carried out, frequency-dependent pararnctcrs are used for the line representation. Arcing faults have also bccn investigated and the results show a great promise of the scheme.展开更多
Due to the increasing demand of energy and the need for nonconventional energy sources, distributed generation (DG) has come into play. The trend of unidirectional power flow has been gradually shifting. With new tech...Due to the increasing demand of energy and the need for nonconventional energy sources, distributed generation (DG) has come into play. The trend of unidirectional power flow has been gradually shifting. With new technology comes new challenges, the introduction of DG into the conventional power system brings various challenges;one of the major challenges is system protection under DG sources. These sources pose a significant challenge due to bidirectional flows from DGs as well as lower fault current contribution from inverter interfaced DGs. This paper reviews existing protection schemes that have been suggested for active distribution networks. Most of these protection strategies apply only to smaller distribution systems implying that they may need to be extended to larger systems with a much higher penetration of distributed generation. In the end, a potential protection scheme has also been recommended as a future work.展开更多
Distributed generation (DG) is the future of energy. This technology allows the bidirectional flow of power within an electrical network. Researchers are faced with many challenges to the accurate implementation of pr...Distributed generation (DG) is the future of energy. This technology allows the bidirectional flow of power within an electrical network. Researchers are faced with many challenges to the accurate implementation of protection schemes for DG-connected distribution network. The schemes designed must satisfy the performance requirements of selectivity, reliability, and sensitivity. Most researchers opine that conventional protection schemes based on over current detection are insufficient to completely and accurately protect a DG-connected distributed power system. There are many challenges?that?need to be tackled before embarking upon the journey to successfully implement these schemes. This paper summarizes the major challenges which one can encounter while designing protection schemes for DG-connected distribution networks. Some possible solutions from the literature are also mentioned. Moreover, a suggested solution for protecting future active distribution networks is provided. It is expected that this paper will act as a benchmark for future researchers in this field to tackle the challenges related to the protection of active distribution networks.展开更多
When the user getting location based services by the traditional technology,his location information of region is always be exposed.However,in modern mobile networks,even the current geographical region is a part of p...When the user getting location based services by the traditional technology,his location information of region is always be exposed.However,in modern mobile networks,even the current geographical region is a part of privacy information.To solve this problem,a new generalized k-anonymity location privacy protection scheme in location based services(LPPS-GKA)with the third trust servicer is proposed.And it can guarantee the users get good location-based services(LBS)without leaking the information of the geo-location region,which has protected the perfect privacy.Analysis shows that LPPS-GKA is more secure in protecting location privacy,including region information,and is more efficient than other similar schemes in computational and communicational aspects.It is suitable for dynamic environment for different user’s various privacy protection requests.展开更多
We present a comparison of data obtained during testing of lightning protective system of a residential structure in rocket-triggered lightning experiment at the International Center for Lightning Research and Testing...We present a comparison of data obtained during testing of lightning protective system of a residential structure in rocket-triggered lightning experiment at the International Center for Lightning Research and Testing(ICLRT)at Camp Blanding,Florida,and current surge generator experiment at Rzeszow University of Technology in Poland.Three different configurations of LPS were tested in Poland with the dc grounding resistances of the entire system 4.09 Ω(LPS 1a),1.65 Ω(LPS 1b),and 2.88 Ω(LPS 2).For LPS 1a with three ground rods the value of the peak current entering the electrical circuit neutral was about 56% of the injected current peak,and for LPS 1b with two additional ground rods and two 5 m long buried horizontal conductors it was about 16%.For LPS 2 with five ground rods interconnected by a buried loop conductor this ratio was 21%.The current waveshapes in the ground rods differed from the injected current waveshapes and the current waveshapes in other parts of the test system,especially,for poorer-grounding LPS 1a.The surge-generator results are consistent with those of triggered-lightning experiments at Camp Blanding,Florida(DeCarlo et al.,2008 [2]).展开更多
On the basis of expounding the corrosion mechanism of the stator hollow copper conductor in the water-cooling generator, methods of preventing corrosion of the stator hollow copper conductor in the wa-ter-cooling gene...On the basis of expounding the corrosion mechanism of the stator hollow copper conductor in the water-cooling generator, methods of preventing corrosion of the stator hollow copper conductor in the wa-ter-cooling generator through adjusting water quality of its cooling water have been proposed. For internal water cooling systems which are airtight, the corrosion of the hollow copper conductor can be prevented through keeping foreign oxygen and carbon dioxide from entering the system, and the amount of oxygen in the internal water can be lowered by blowing high purity nitrogen. For systems not airtight, the corrosion of the hollow copper conductor can be inhibited through lowering the amount of oxygen to some extent by sealing and increasing pH value by processing part of cooling water with bypass small flow sodium-type mix-bed.展开更多
The path protection approach is widely investigated as a survivability solution for GMPLS networks, which has the advantage of efficient capacity utilization. However, there is a problem of the path protection approac...The path protection approach is widely investigated as a survivability solution for GMPLS networks, which has the advantage of efficient capacity utilization. However, there is a problem of the path protection approach that searching a disjoint backup path for a primary path is often unsuccessful. In order to resolve this problem, an integrated dynamic shared protection (IDSP) algorithm is proposed. The main idea of the proposed algorithm is that the path protection approach is first used to establish a backup path for the primary path; if the establishment is unsuccessful, then the primary path is dynamically divided into segments whose hop count are not fixed but not more than the limitation calculated by the equations introduced. In this proposal, backup bandwidth sharing is allowed to improve the capacity utilization ratio, which makes the link cost function quite different from previous ones. Simulation experiments are presented to demonstrate the efficiency of the proposed method compared with previous methods. Numerical results show that IDSP can not only achieve low protection failure probability but can also gain a better tradeoff between the protection overbuild and the average recovery time.展开更多
To improve the resource utilization ratio and shorten the recovery time of the shared path protection with differentiated reliability (SPP-DiR) algorithm, an algorithm called dynamic shared segment protection with d...To improve the resource utilization ratio and shorten the recovery time of the shared path protection with differentiated reliability (SPP-DiR) algorithm, an algorithm called dynamic shared segment protection with differentiated reliability (DSSP-DiR) is proposed for survivable GMPLS networks. In the proposed algorithm, a primary path is dynamically divided into several segments according to the differentiated reliability requirements of the customers. In the SPP-DiR algorithm, the whole primary path should be protected, while in the DSSP- DiR algorithm, only partial segments on the primary path need to be protected, which can reduce more backup bandwidths than that in the SPP-DiR algorithm. Simulation results show that the DSSP-DiR algorithm achieves higher resource utilization ratio, lower protection failure probability, and shorter recovery time than the SPP-DiR algorithm.展开更多
A simulation system for power grid with concentrated large-scale wind farm integration is established based on the electro-magnetic transient model of wind turbine equipped with doubly-fed induction generator (DFIG),w...A simulation system for power grid with concentrated large-scale wind farm integration is established based on the electro-magnetic transient model of wind turbine equipped with doubly-fed induction generator (DFIG),which is built by real-time digital simulator (RTDS).Using the hardware communication interface of RTDS,a closed-loop testing experiment is accomplished to study the impacts of large-scale wind farms on the existing relay protection devices for wind farm outgoing transmission line.This paper points out problems existing in current relay protection devices as follows:fault phase selector can select unwanted phase due to the changes of fault features caused by special network connection of wind farms;blocking condition for distance protections needs to be re-examined due to the weak power-feed characteristics of wind farms;and power frequency parameter based relay protection devices cannot accurately operate due to the special transient voltage and current characteristics of wind farms during fault period.Results lay the foundation for improving the performances of the existing relay protection device and developing new principle relay protection.展开更多
文摘对2007年版《IEEE Guide for AC Generator Protection》中失磁保护定值整定的几个问题提出不同意见。明确指出:发电机失磁故障必有滑差(s),其平均异步阻抗Xd(js)Xd(s=0),失磁保护中的阻抗元件下端定值为-Xd,已有足够余度,不应该是-(1.1~1.25)Xd;在P-Q坐标与R-X坐标的转换公式中,U值应由"失磁保护动作滞后于低励限制线(UEL)"原则来确定,不应主观选择0.95UN。
基金supported in part by the National Natural Science Foundation of China(52177042)Natural Science Foundation of Hebei Province(E2020502031)+1 种基金the Fundamental Research Funds for the Central Universities(2017MS151),Suzhou Social Developing Innovation Project of Science and Technology(SS202134)the Top Youth Talent Support Program of Hebei Province([2018]-27).
文摘This paper proposed a new diagnosis model for the stator inter-turn short circuit fault in synchronous generators.Different from the past methods focused on the current or voltage signals to diagnose the electrical fault,the sta-tor vibration signal analysis based on ACMD(adaptive chirp mode decomposition)and DEO3S(demodulation energy operator of symmetrical differencing)was adopted to extract the fault feature.Firstly,FT(Fourier trans-form)is applied to the vibration signal to obtain the instantaneous frequency,and PE(permutation entropy)is calculated to select the proper weighting coefficients.Then,the signal is decomposed by ACMD,with the instan-taneous frequency and weighting coefficient acquired in the former step to obtain the optimal mode.Finally,DEO3S is operated to get the envelope spectrum which is able to strengthen the characteristic frequencies of the stator inter-turn short circuit fault.The study on the simulating signal and the real experiment data indicates the effectiveness of the proposed method for the stator inter-turn short circuit fault in synchronous generators.In addition,the comparison with other methods shows the superiority of the proposed model.
文摘Distributed generators now is widely used in electrical power networks, in some cases it works seasonally, and some types works at special weather conditions like photo voltaic systems and wind energy, and due to this continuous changes in generation condition, the fault current level in network will be affected, this changes in fault current level will affect in the coordination between protection relays and to keep the coordination at right way, an adaptive protection system is required that can adaptive its setting according to generation changes, the fault current level in each case is evaluated using ETAP software, and the required relay setting in each case is also evaluated using Grey Wolf Optimizer (GWO) algorithm, and to select suitable setting which required in each condition, to select the active setting group of protection relay according to generation capacity, central protection unite can be used, and to improve protection stability and minimizing relays tripping time, a proposed method for selecting suitable backup relay is used, which leads to decrease relays tripping time and increase system stability, output settings for relays in all cases achieved our constrains.
基金supported by the Natural Sciences and Engineering Research Council (NSERC)Canada Research Chairs (CRC) Programs+2 种基金the financial support from the National Natural Science Foundation of China (51975033)the Beijing Natural Science Foundation (3192020)the China Scholarship Council (CSC) for the graduate fellowship
文摘With the increase in the use of electronic devices in many different environments,a need has arisen for an easily implemented method for the rapid,sensitive detection of liquids in the vicinity of electronic components.In this work,a high-performance power generator that combines carbon nanoparticles and TiO2 nanowires has been fabricated by sequential electrophoretic deposition(EPD).The opencircuit voltage and short-circuit current of a single generator are found to exceed 0.7 V and 100μA when 6μL of water was applied.The generator is also found to have a stable and reproducible response to other liquids.An output voltage of 0.3 V was obtained after 244,876,931,and 184μs,on exposure of the generator to 6μL of water,ethanol,acetone,and methanol,respectively.The fast response time and high sensitivity to liquids show that the device has great potential for the detection of small quantities of liquid.In addition,the simple easily implemented sequential EPD method ensures the high mechanical strength of the device.This compact,reliable device provides a new method for the sensitive,rapid detection of extraneous liquids before they can impact the performance of electronic circuits,particularly those on printed circuit board.
文摘Nowadays wind energy is the fastest growing renewable energy resource in the world.The problems of integrating wind farms are caused by changes of wind speed during a day.Moreover,the behaviors of wind turbines equipped with doubly-fed induction generators differ fundamentally from synchronous generators.Therefore,more considerations are needed to analyze the performances of the distance protection relays.The protection of a wind farm with distance relay is inspected.By changing the conditions of the wind farm,the characteristics of the distance relay are studied.
文摘Generator control system decides whether the generator can work as usual or not, as well as its stability of performance. Both types of generators control system composed of the transistor and DSP are sensitive to outward electromagnetic interference, directly related to the generator performance. In this text, we first analyze the electromagnetic interference threat generator control system of transistor type may face, then design a electromagnetic protection plan for the intake, the panel and the sense organ. This work is of great significance in improving its electromagnetic protection ability and stability of performance.
文摘Domestic generators will be used in ThreeGorges Hydropower Station in the future, this paper introduces the corresponding protection system design for them, including the special requirements and the configuration of the protection system. To increase compactness and reduce relay cost, the protection equipment will adopt the dual-system structure with a manager system and several subsystems considering the protection funcition redundancy. Some special function principles and methods, the communications, the protection modules and the managing system are also discussed in detail.
文摘Fault Ride-Through (FRT) capabilities set up according to the grid codes may affect the performance of related protective elements during fault periods. Therefore, in this paper the coordination between the FRT capability and over-current protection of DFIG Wind Generators in MV networks is investigated. Simulation test cases using MATLAB-Simulink are implemented on a 365-MW wind farm in AL-Zaafarana, Egypt. The simulation results show the influence of the FRT capability on the protective relaying coordination in wind farms, showing that the FRT may work in situations where is were expected not to work, and then disabling the over-current protection, which should have worked in this situation.
文摘Synchronous generators are important components of power systems and are necessary to maintain its normal and stable operation.To perform the fault diagnosis of mild inter-turn short circuit in the excitation winding of a synchronous generator,a gate recurrent unit-convolutional neural network(GRU-CNN)model whose structural parameters were determined by improved particle swarm optimization(IPSO)is proposed.The outputs of the model are the excitation current and reactive power.The total offset distance,which is the fusion of the offset distance of the excitation current and offset distance of the reactive power,was selected as the fault judgment criterion.The fusion weights of the excitation current and reactive power were determined using the anti-entropy weighting method.The fault-warning threshold and fault-warning ratio were set according to the normal total offset distance,and the fault warning time was set according to the actual situation.The fault-warning time and fault-warning ratio were used to avoid misdiagnosis.The proposed method was verified experimentally.
文摘<div style="text-align:justify;"> Generalized S-transform is a time-frequency analysis method which has higher resolution than S-transform. It can precisely extract the time-amplitude characteristics of different frequency components in the signal. In this paper, a novel protection method for VSC-HVDC (Voltage source converter based high voltage DC) based on Generalized S-transform is proposed. Firstly, extracting frequency component of fault current by Generalized S-transform and using mutation point of high frequency to determine the fault time. Secondly, using the zero-frequency component of fault current to eliminate disturbances. Finally, the polarity of sudden change currents in the two terminals is employed to discriminate the internal and external faults. Simulations in PSCAD/EMTDC and MATLAB show that the proposed method can distinguish faults accurately and effectively. </div>
文摘The use of non-power frequency components for protection measurements in an area that has received relatively little attention. Although work on the use of switched stack tuners has been reported for fault detection, the sensitivity of switched arrangements is limited by scnsitivity of directional detectors for switching purposes. This paper presents an alternative non-switching scheme which is relatively simple.A simplified typical 400kV system with the line trap, stack tuner, coupling capacitor and bus capacitance to earth is considered. Fault studies by using the EMTP have been carried out, frequency-dependent pararnctcrs are used for the line representation. Arcing faults have also bccn investigated and the results show a great promise of the scheme.
文摘Due to the increasing demand of energy and the need for nonconventional energy sources, distributed generation (DG) has come into play. The trend of unidirectional power flow has been gradually shifting. With new technology comes new challenges, the introduction of DG into the conventional power system brings various challenges;one of the major challenges is system protection under DG sources. These sources pose a significant challenge due to bidirectional flows from DGs as well as lower fault current contribution from inverter interfaced DGs. This paper reviews existing protection schemes that have been suggested for active distribution networks. Most of these protection strategies apply only to smaller distribution systems implying that they may need to be extended to larger systems with a much higher penetration of distributed generation. In the end, a potential protection scheme has also been recommended as a future work.
文摘Distributed generation (DG) is the future of energy. This technology allows the bidirectional flow of power within an electrical network. Researchers are faced with many challenges to the accurate implementation of protection schemes for DG-connected distribution network. The schemes designed must satisfy the performance requirements of selectivity, reliability, and sensitivity. Most researchers opine that conventional protection schemes based on over current detection are insufficient to completely and accurately protect a DG-connected distributed power system. There are many challenges?that?need to be tackled before embarking upon the journey to successfully implement these schemes. This paper summarizes the major challenges which one can encounter while designing protection schemes for DG-connected distribution networks. Some possible solutions from the literature are also mentioned. Moreover, a suggested solution for protecting future active distribution networks is provided. It is expected that this paper will act as a benchmark for future researchers in this field to tackle the challenges related to the protection of active distribution networks.
基金This work was supported in part by the National Natural Science Foundation of China(Nos.61272492 and 61572521),Shaanxi Province Natural Science Foundation of China(No.2015JM6353)and the Basic Foundation of Engineering University of CAPF(No.WJY201521).
文摘When the user getting location based services by the traditional technology,his location information of region is always be exposed.However,in modern mobile networks,even the current geographical region is a part of privacy information.To solve this problem,a new generalized k-anonymity location privacy protection scheme in location based services(LPPS-GKA)with the third trust servicer is proposed.And it can guarantee the users get good location-based services(LBS)without leaking the information of the geo-location region,which has protected the perfect privacy.Analysis shows that LPPS-GKA is more secure in protecting location privacy,including region information,and is more efficient than other similar schemes in computational and communicational aspects.It is suitable for dynamic environment for different user’s various privacy protection requests.
文摘We present a comparison of data obtained during testing of lightning protective system of a residential structure in rocket-triggered lightning experiment at the International Center for Lightning Research and Testing(ICLRT)at Camp Blanding,Florida,and current surge generator experiment at Rzeszow University of Technology in Poland.Three different configurations of LPS were tested in Poland with the dc grounding resistances of the entire system 4.09 Ω(LPS 1a),1.65 Ω(LPS 1b),and 2.88 Ω(LPS 2).For LPS 1a with three ground rods the value of the peak current entering the electrical circuit neutral was about 56% of the injected current peak,and for LPS 1b with two additional ground rods and two 5 m long buried horizontal conductors it was about 16%.For LPS 2 with five ground rods interconnected by a buried loop conductor this ratio was 21%.The current waveshapes in the ground rods differed from the injected current waveshapes and the current waveshapes in other parts of the test system,especially,for poorer-grounding LPS 1a.The surge-generator results are consistent with those of triggered-lightning experiments at Camp Blanding,Florida(DeCarlo et al.,2008 [2]).
文摘On the basis of expounding the corrosion mechanism of the stator hollow copper conductor in the water-cooling generator, methods of preventing corrosion of the stator hollow copper conductor in the wa-ter-cooling generator through adjusting water quality of its cooling water have been proposed. For internal water cooling systems which are airtight, the corrosion of the hollow copper conductor can be prevented through keeping foreign oxygen and carbon dioxide from entering the system, and the amount of oxygen in the internal water can be lowered by blowing high purity nitrogen. For systems not airtight, the corrosion of the hollow copper conductor can be inhibited through lowering the amount of oxygen to some extent by sealing and increasing pH value by processing part of cooling water with bypass small flow sodium-type mix-bed.
基金supported by the National Natural Science Foundation of China (60673142)Applied Basic Research Project of Sichuan Province (2006J13-067).
文摘The path protection approach is widely investigated as a survivability solution for GMPLS networks, which has the advantage of efficient capacity utilization. However, there is a problem of the path protection approach that searching a disjoint backup path for a primary path is often unsuccessful. In order to resolve this problem, an integrated dynamic shared protection (IDSP) algorithm is proposed. The main idea of the proposed algorithm is that the path protection approach is first used to establish a backup path for the primary path; if the establishment is unsuccessful, then the primary path is dynamically divided into segments whose hop count are not fixed but not more than the limitation calculated by the equations introduced. In this proposal, backup bandwidth sharing is allowed to improve the capacity utilization ratio, which makes the link cost function quite different from previous ones. Simulation experiments are presented to demonstrate the efficiency of the proposed method compared with previous methods. Numerical results show that IDSP can not only achieve low protection failure probability but can also gain a better tradeoff between the protection overbuild and the average recovery time.
基金supported by the National Natural Science Foundation of China (60673142)Applied Basic Research Project of Sichuan Province (2006J13-067)
文摘To improve the resource utilization ratio and shorten the recovery time of the shared path protection with differentiated reliability (SPP-DiR) algorithm, an algorithm called dynamic shared segment protection with differentiated reliability (DSSP-DiR) is proposed for survivable GMPLS networks. In the proposed algorithm, a primary path is dynamically divided into several segments according to the differentiated reliability requirements of the customers. In the SPP-DiR algorithm, the whole primary path should be protected, while in the DSSP- DiR algorithm, only partial segments on the primary path need to be protected, which can reduce more backup bandwidths than that in the SPP-DiR algorithm. Simulation results show that the DSSP-DiR algorithm achieves higher resource utilization ratio, lower protection failure probability, and shorter recovery time than the SPP-DiR algorithm.
基金supported by the Special Fund of the National Basic Research Program of China (973 Program) (No.2009CB219704)
文摘A simulation system for power grid with concentrated large-scale wind farm integration is established based on the electro-magnetic transient model of wind turbine equipped with doubly-fed induction generator (DFIG),which is built by real-time digital simulator (RTDS).Using the hardware communication interface of RTDS,a closed-loop testing experiment is accomplished to study the impacts of large-scale wind farms on the existing relay protection devices for wind farm outgoing transmission line.This paper points out problems existing in current relay protection devices as follows:fault phase selector can select unwanted phase due to the changes of fault features caused by special network connection of wind farms;blocking condition for distance protections needs to be re-examined due to the weak power-feed characteristics of wind farms;and power frequency parameter based relay protection devices cannot accurately operate due to the special transient voltage and current characteristics of wind farms during fault period.Results lay the foundation for improving the performances of the existing relay protection device and developing new principle relay protection.