期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Intercombination transitions of the carbon-like isoelectronic sequence 被引量:1
1
作者 刘浩 蒋刚 +3 位作者 胡峰 王传珂 王哲斌 杨家敏 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第7期119-130,共12页
Energy levels, wavelengths, transition rates, oscillator strengths, and lifetimes between the 2s22p23P1,2s22p23P2,and 2s2p35S2 levels of ions in the carbon-like (C-like) isoelectronic sequence (nuclear charges Z=7... Energy levels, wavelengths, transition rates, oscillator strengths, and lifetimes between the 2s22p23P1,2s22p23P2,and 2s2p35S2 levels of ions in the carbon-like (C-like) isoelectronic sequence (nuclear charges Z=7-92) are calculated in the valence and core-valence limits using the multiconfiguration Dirac–Fock method. The Breit interaction, quantum electrodynamics (QED), and finite nuclear mass effects are taken into account in subsequent relativistic configuration-interaction calculations. The calculated energies and transition rates are compared with the critically evaluated experimental values and other recent calculated results. Our calculated data are in good agreement with these data. 展开更多
关键词 carbon-like isoelectronics sequence intercombination transition multiconfiguration Dirac-Fock method highly-charged ions
下载PDF
Precision frequency measurement of 1^S0–3^P1 intercombination lines of Sr isotopes 被引量:3
2
作者 刘辉 高峰 +6 位作者 王叶兵 田晓 任洁 卢本全 徐琴芳 谢玉林 常宏 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第1期208-215,共8页
We report on frequency measurement of the intercombination(5s^2)^1S0–(5s5p)^3P1transition of the four natural isotopes of strontium, including88^Sr(82.58%),87^Sr(7.0%),86^Sr(9.86%), and84^Sr(0.56%). A nar... We report on frequency measurement of the intercombination(5s^2)^1S0–(5s5p)^3P1transition of the four natural isotopes of strontium, including88^Sr(82.58%),87^Sr(7.0%),86^Sr(9.86%), and84^Sr(0.56%). A narrow-linewidth laser that is locked to an ultra-low expansion(ULE) optical cavity with a finesse of 12000 is evaluated at a linewidth of 200 Hz with a fractional frequency drift of 2.8×10^-13 at an integration time of 1 s. The fluorescence collector and detector are specially designed, based on a thermal atomic beam. Using a double-pass acousto-optic modulator(AOM) combined with a fiber and laser power stabilization configuration to detune the laser frequency enables high signal-to-noise ratios and precision saturated spectra to be obtained for the six transition lines, which allows us to determine the transition frequency precisely.The optical frequency is measured using an optical frequency synthesizer referenced to an H maser. Both the statistical values and the final values, including the corrections and uncertainties, are derived for a comparison with the values given in other works. 展开更多
关键词 optical frequency measurement STRONTIUM intercombination transition
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部