期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Interface analysis of 7B52 Al alloy laminated composite fabricated by hot-roll bonding 被引量:9
1
作者 周古昕 郎玉婧 +4 位作者 郝洁 刘稳 王生 乔丽 陈敏 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2016年第5期1269-1275,共7页
The bonding interface of 7B52 Al alloy laminated composite (ALC) fabricated by hot rolling was investigated using optical microscopy (OM), transmission electron microscopy (TEM), scanning electron microscopy (... The bonding interface of 7B52 Al alloy laminated composite (ALC) fabricated by hot rolling was investigated using optical microscopy (OM), transmission electron microscopy (TEM), scanning electron microscopy (SEM), ultrasonic flaw detection (UFD), and bonding strength tests. The results show that metallurgical bonding is achieved at the interface after composite rolling. The TEM analysis and tensile tests indicate that the 7B52 ALC plate combines high strength of the hard individual layer and good toughness of the soft individual layer. However, UFD technology and SEM analysis prove that the defects (thick oxide films, acid washed residues, air, oil and coarse particles) existing in the bonding interface are harmful to the bonding strength. To sum up, the composite roiling process is suitable for 7B52 ALC plate, and the content and size of the defects should be controlled strictly. Advanced surface treatment of each individual layer would be beneficial to further improve the bonding quality. 展开更多
关键词 7B52 alurninium alloy laminated composite hot-roll bonding MICROSTRUCTURE interfacial analysis
下载PDF
Stress Transfer Modeling at the Interface of Cemented Prosthesis and Femur
2
作者 YU Xue-zhong GUO Yi-mu +2 位作者 ZHANG Yun-qiu LI Jun HE Rong-xing 《Chinese Journal of Biomedical Engineering(English Edition)》 2008年第2期61-70,共10页
Objective:To model the stress transfer at the interface of the cemented prosthesis and femur, an axisymmetric model of the interfacial stress transfer was established. Methods : Assuming that the prosthesis, the cem... Objective:To model the stress transfer at the interface of the cemented prosthesis and femur, an axisymmetric model of the interfacial stress transfer was established. Methods : Assuming that the prosthesis, the cement and the femur were concentric cylinders with linear elastic and isotropic properties, distributions of the axial stresses in the prosthesis, the cement and the femur as well as the interfacial shear stresses at the prosthesis/cement interface and the cement/femur interface in the axial direction were obtained from the established axisymmetric stress transfer model. Results : Interfacial failure was the main form for the prosthesis/cement/femur structure under external loads. Considering the residual thermal stresses, it was more likely to produce the mixed failure form than the pure shear failure form. Since the cement had a relatively high thermal expansion coefficient, the thermal effect accelerated the interface failure and thus aggravated the stress shielding effect. Due to a relatively high thermal residual temperature difference, the interfacial debonding and femur failure was more likely to occur for the cobalt-chromium alloy prosthesis material than the Ti-6A1-4V alloy prosthesis material. Conclusion: Assuming that the prosthesis, the cement and the femur are concentric cylinders with linear elastic and isotropic properties, distributions of the axial stresses in the prosthesis, the cement and the femur as well as the interfacial shear stresses at the prosthesis/cement interface and the cement/femur interface in the axial direction was obtained using the basic equations of axisymmetric elastic mechanics when the prosthesis bears the compressive stresses. Interface failure is the main failure form for the prosthesis/cement/femur structure under external loads. The thermal effects accelerate the failure of the prosthesis/cement interface and the cement/femur interface and the relaxation of the prosthesis, and then aggravates the stress shielding effect of the femur. Also, the thermal effects decrease the efficiencies of the interfacial stress transfer to some extent since it alleviates the failure of the interface and the femur, which was confirmed by the clinical results. 展开更多
关键词 FEMUR cemented prosthesis interfacial stress analysis
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部