期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
CORRECTION OF WING INTERFERENCE WITH KALMAN FILTERING IN INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION SPECTROMETRY
1
作者 Jin Fu YANG Zhe Xiu PIAO +2 位作者 Xian Jin ZENG Zhuo Yong ZHANG Xin Hai CHEN 《Chinese Chemical Letters》 SCIE CAS CSCD 1992年第3期193-196,共4页
A Kalman filter was developed for correction of wing interference in ICP-AES.Modeling wing interference theoretically instead of experimentally, the filter can compensate the shift in wavelength position in scans, and... A Kalman filter was developed for correction of wing interference in ICP-AES.Modeling wing interference theoretically instead of experimentally, the filter can compensate the shift in wavelength position in scans, and therefore reduce the effect of the interference on detection limit. 展开更多
关键词 LINE correction OF WING interference WITH KALMAN FILTERING IN INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION SPECTROMETRY LA
下载PDF
Determination of micro yttrium in an ytterbium matrix by inductively coupled plasma atomic emission spectrometry and wavelet transform 被引量:2
2
作者 MAXiaoguo 《Rare Metals》 SCIE EI CAS CSCD 2005年第2期137-141,共5页
In the determination of trace yttrium (Y) in an ytterbium (Yb) matrix byinductively coupled plasma atomic emission spectrometry (ICP-AES), the most prominent line ofyttrium, Y 371.030 nm line, suffers from strong inte... In the determination of trace yttrium (Y) in an ytterbium (Yb) matrix byinductively coupled plasma atomic emission spectrometry (ICP-AES), the most prominent line ofyttrium, Y 371.030 nm line, suffers from strong interference due to an emission line of ytterbium.In mis work, a method based on wavelet transform was proposed for the spectral interferencecorrection. Haar wavelet was selected as the mother wavelet. The discrete detail after the thirddecomposition, D3, was chosen for quantitative analysis based on the consideration of bothseparation degree and peak height. The linear correlation coefficient between the height of the leftpositive peak in D3 and the concentration of Y was calculated to be 0.9926. Six synthetic sampleswere analyzed, and the recovery for yttrium varied from 96.3 percent to 110.0 percent. The amountsof yttrium in three ytterbium metal samples were determined by the proposed approach with an averagerelative standard deviation (RSD) of 2.5 percent, and the detection limit for yttrium was 0.016percent. This novel correction technique is fast and convenient, since neither complicated modelassumption nor time-consuming iteration is required. Furthermore, it is not affected by thewavelength drift inherent in monochromators that will severely reduce the accuracy of resultsobtained by some chemometric methods. 展开更多
关键词 analytical chemistry trace analysis inductively coupled plasma atomicemission spectrometry (ICP-AES) wavelet transform spectral interference correction YTTRIUM YTTERBIUM
下载PDF
Simple and cost-effective methods for precise analysis of trace element abundances in geological materials with ICP-MS 被引量:22
3
作者 Shuo Chen Xiaohong Wang +7 位作者 Yaoling Niu Pu Sun Meng Duan Yuanyuan Xiao Pengyuan Guo Hongmei Gong Guodong Wang Qiqi Xue 《Science Bulletin》 SCIE EI CAS CSCD 2017年第4期277-289,共13页
Inductively coupled plasma mass spectrometry (ICP-MS) is the most commonly used technique to deter- mine the abundances of trace elements in a wide range of geological materials. However, incomplete sample digestion... Inductively coupled plasma mass spectrometry (ICP-MS) is the most commonly used technique to deter- mine the abundances of trace elements in a wide range of geological materials. However, incomplete sample digestion, isobaric interferences and instrumental drift remain obvious problems that must be overcome in order to obtain precise and accurate results, For this reason, we have done many experi- ments and developed a set of simple, cost-effective and practical methods widely applicable for precise and rapid determination of trace element abundances in geological materials using ICP-MS. Commonly used high-pressure digestion technique is indeed effective in decomposing refractory phases, but this inevitably produces fluoride complexes that create new problems. We demonstrate that the fluoride complexes formed during high-pressure digestion can be readily re-dissolved using high-pressure vessel at 190 ℃ for only 2 h for 50 mg sample. In the case of isobaric interferences, although oxide (e.g., MO^+/M^+) and hydroxide (e.g., MO^+/M^+) productivity is variable between runs, the (MO^+/M^+)/(CeO^+/Ce^+) and (MOH^+/M^+)/(CeO^+/Ce^+) ratios remain constant, making isobaric interference correction for all other elements of interest straightforward, for which we provide an easy-to-use off-line procedure. We also show that mass-time-intensity drift curve is smooth as recognized previously, for which the correction can be readily done by analyzing a quality-control (QC) solution and using off-line Excel VBA procedure without internal standards. With these methods, we can produce data in reasonable agreement with rec- ommended values of international rock reference standards with a relative error of 〈8% and precision generally better than 5%. Importantly, compared to the widely used analytical practice, we can effectively save 〉60% of time (e.g., 〈24 h vs. 〉60 h). 展开更多
关键词 Inductively coupled plasma mass spectrometry High-pressure digestion Oxide and hydroxide interferences Instrumental drift correction methods Trace elements
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部