Various types of rib and interlock fabrics found in the market depend on their structure such as 1 × 1 rib, 2 × 1 rib, 2 × 2 rib, 3 × 1 rib, 3 × 2 rib, 4 × 1 rib, 4 × 4 rib and 1 ...Various types of rib and interlock fabrics found in the market depend on their structure such as 1 × 1 rib, 2 × 1 rib, 2 × 2 rib, 3 × 1 rib, 3 × 2 rib, 4 × 1 rib, 4 × 4 rib and 1 × 1 interlock, 2 × 2 interlock etc. These all types of fabric can be possible to knit in circular knitting machine after machine setting. When these fabrics are knit on the machine, some needles are needed to drop or withdrawn from needle groove according to their design such as 1 × 1, 2 × 1, 2 × 2 etc. Due to needle dropping or withdrawing production per hour will changed as production per hour directly depends on the No. of active needle. No. of needle or active needle depends on machine gauge. This paper gives a new approach for machine gauge which is somewhat different from other thinking. This paper also shows the production calculation formula with their machine setting for various rib and interlock fabric with their derivation. By this paper, one can easily understood about machine gauge and calculated production of any type of rib and interlock knitted structure. Complexity of calculating production can be reduced by this paper.展开更多
为研究变密度结构设计对三维机织角联锁复合材料面外力学性能的影响,设计制备了三维机织角联锁不变密度复合材料、三维机织角联锁经纱变密度复合材料和三维机织角联锁纬纱变密度复合材料。结合扫描电子显微镜、数字图像相关技术和X射线...为研究变密度结构设计对三维机织角联锁复合材料面外力学性能的影响,设计制备了三维机织角联锁不变密度复合材料、三维机织角联锁经纱变密度复合材料和三维机织角联锁纬纱变密度复合材料。结合扫描电子显微镜、数字图像相关技术和X射线计算机断层扫描等检测技术,对角联锁变密度复合材料的面外压缩力学行为、内部损伤量化和渐进损伤等进行了测试与表征。研究结果表明:上疏下密角联锁纬纱变密度复合材料展现出优异的压缩性能,其压缩比强度比不变密度复合材料高3.40%;同时,上疏下密角联锁纬纱变密度复合材料损伤体积仅为11.64 mm 3,远低于不变密度复合材料的26.90 mm 3。进一步分析得到,不变密度复合材料压缩破坏以剪切失效为主,而上疏下密角联锁纬纱变密度复合材料则为基体开裂。展开更多
The performance degradation and even damage of the e-textiles caused by sweat,water,or submersion during all-weather health monitoring are the main reasons that e-textiles have not been commercialized and routinized s...The performance degradation and even damage of the e-textiles caused by sweat,water,or submersion during all-weather health monitoring are the main reasons that e-textiles have not been commercialized and routinized so far.Herein,we developed an amphibious,high-performance,air-permeable,and comfortable all-textile triboelectric sensor for continuous and precise measurement of epidermal pulse waves during full-day activities.Based on the principle of preparing gas by acid-base neutralization reaction,a one-piece preparation process of amphibious conductive yarn(ACY)with densely porous structures is proposed.An innovative three-dimensional(3D)interlocking fabric knitted from ACYs(0.6 mm in diameter)and polytetrafluoroethylene yarns exhibit high sensitivity(0.433 V·kPa^(-1)),wide bandwidth(up to 10 Hz),and stability(>30,000 cycles).With these benefits,98.8%agreement was achieved between wrist pulse waves acquired by the sensor and a high-precision laser vibrometer.Furthermore,the polytetrafluoroethylene yarn with good compression resilience provides sufficient mechanical support for the contact separation of the ACYs.Meanwhile,the unique skeletonized design of the 3D interlocking structure can effectively relieve the water pressure on the sensor surface to obtain stable and accurate pulse waves(underwater depth of 5 cm).This achievement represents an important step in improving the practicality of e-textiles and early diagnosis of cardiovascular diseases.展开更多
文摘Various types of rib and interlock fabrics found in the market depend on their structure such as 1 × 1 rib, 2 × 1 rib, 2 × 2 rib, 3 × 1 rib, 3 × 2 rib, 4 × 1 rib, 4 × 4 rib and 1 × 1 interlock, 2 × 2 interlock etc. These all types of fabric can be possible to knit in circular knitting machine after machine setting. When these fabrics are knit on the machine, some needles are needed to drop or withdrawn from needle groove according to their design such as 1 × 1, 2 × 1, 2 × 2 etc. Due to needle dropping or withdrawing production per hour will changed as production per hour directly depends on the No. of active needle. No. of needle or active needle depends on machine gauge. This paper gives a new approach for machine gauge which is somewhat different from other thinking. This paper also shows the production calculation formula with their machine setting for various rib and interlock fabric with their derivation. By this paper, one can easily understood about machine gauge and calculated production of any type of rib and interlock knitted structure. Complexity of calculating production can be reduced by this paper.
文摘为研究变密度结构设计对三维机织角联锁复合材料面外力学性能的影响,设计制备了三维机织角联锁不变密度复合材料、三维机织角联锁经纱变密度复合材料和三维机织角联锁纬纱变密度复合材料。结合扫描电子显微镜、数字图像相关技术和X射线计算机断层扫描等检测技术,对角联锁变密度复合材料的面外压缩力学行为、内部损伤量化和渐进损伤等进行了测试与表征。研究结果表明:上疏下密角联锁纬纱变密度复合材料展现出优异的压缩性能,其压缩比强度比不变密度复合材料高3.40%;同时,上疏下密角联锁纬纱变密度复合材料损伤体积仅为11.64 mm 3,远低于不变密度复合材料的26.90 mm 3。进一步分析得到,不变密度复合材料压缩破坏以剪切失效为主,而上疏下密角联锁纬纱变密度复合材料则为基体开裂。
基金supported by the National Key Research and Development Program of China(No.2021YFA1201600)the Natural Science Foundation Projects of Chongqing(No.cstc2022ycjh-bgzxm0206)the Natural Science Foundation of Innovative Research Groups(No.cstc2020jcyj-cxttX0005).
文摘The performance degradation and even damage of the e-textiles caused by sweat,water,or submersion during all-weather health monitoring are the main reasons that e-textiles have not been commercialized and routinized so far.Herein,we developed an amphibious,high-performance,air-permeable,and comfortable all-textile triboelectric sensor for continuous and precise measurement of epidermal pulse waves during full-day activities.Based on the principle of preparing gas by acid-base neutralization reaction,a one-piece preparation process of amphibious conductive yarn(ACY)with densely porous structures is proposed.An innovative three-dimensional(3D)interlocking fabric knitted from ACYs(0.6 mm in diameter)and polytetrafluoroethylene yarns exhibit high sensitivity(0.433 V·kPa^(-1)),wide bandwidth(up to 10 Hz),and stability(>30,000 cycles).With these benefits,98.8%agreement was achieved between wrist pulse waves acquired by the sensor and a high-precision laser vibrometer.Furthermore,the polytetrafluoroethylene yarn with good compression resilience provides sufficient mechanical support for the contact separation of the ACYs.Meanwhile,the unique skeletonized design of the 3D interlocking structure can effectively relieve the water pressure on the sensor surface to obtain stable and accurate pulse waves(underwater depth of 5 cm).This achievement represents an important step in improving the practicality of e-textiles and early diagnosis of cardiovascular diseases.