Laser-induced breakdown spectroscopy was employed to determine the inorganic elements in coal. To improve the measurement's accuracy and precision, a new internal standardization scheme, which we named changed intern...Laser-induced breakdown spectroscopy was employed to determine the inorganic elements in coal. To improve the measurement's accuracy and precision, a new internal standardization scheme, which we named changed internal standardization, was compared with the traditional internal standardization and no internal standardization for the analysis of inorganic elements. The new internal standardization scheme used the atomic line of carbon at 247.86 nm and the molecular band of CN at 388.34 nm and C2 at 516.32 nm to normalize the lines of inorganic elements that were distributed in the same spectral channel. The performance of the utilization of the new internal standardization scheme was evaluated using a set of coal samples, including twenty calibration samples and five validation samples. The results show that the coefficients of determination R2 and the slope of calibration models coupled with changed internal standard- ization are better than that of the calibration models coupled with fixed internal standardization and no internal standardization. Moreover, the measurement accuracy and reproducibility of changed internal standardization for the analysis of five validation samples also yielded further improvement. The results that we obtained suggest that changed internal standardization could compensate for the matrix effects, as well as the influence of the difference in the spectral response of the light collection system.展开更多
The external calibration in conjunction with internal standardization(ECIS) coupled with laser-induced breakdown spectroscopic(LIBS) technique was proposed to perform the quantitative analysis of Fe content in iro...The external calibration in conjunction with internal standardization(ECIS) coupled with laser-induced breakdown spectroscopic(LIBS) technique was proposed to perform the quantitative analysis of Fe content in iron ore The plasma temperature and the electron number density were calculated to prove that the plasma was under local thermodynamic equilibrium(LTE) conditions and to ensure that the integral intensities of Fe I lines were reasonable. In addition, the result of the quantitative analysis shows a content of (20.26±0.59)% by mass of Fe in the iron ore. It was determined by four calibration curves, drawn for four emission lines of Fe I(373.48, 373.71,404.58 and 438.35 nm) normalized by Mn I line, base on the ECIS method which can eliminate the influence of matrix effect and improve the accuracy of quantitative analysis, compared with the standard addition method. Both the results of these two analytical methods were compared with that listed in the Standard Substance Certificate. The percentage content of Fe in the same sample of iron ore by the ECIS method was (20.17±0.08)% by mass, which shows a good performance to analyze the Fe content of iron ore in combination with LIBS.展开更多
As one of the most concerned digital technologies in recent years,blockchain and distributed ledger technology are an important driving force for a new round of technological development.It is currently in the process...As one of the most concerned digital technologies in recent years,blockchain and distributed ledger technology are an important driving force for a new round of technological development.It is currently in the process of accelerating its evolution and maturity,and has gradually integrated with other digital technologies.It has been applied in many industries,providing decentralized solutions for various industries,realizing innovative storage models,and building a new trust system.As blockchain technology is officially incorporated into China’s new information infrastructure category,the application fields of blockchain have expanded rapidly,gradually extending from the financial field and government affairs to other fields in the real economy.At the same time,with the continuous development of the globalized economy,blockchain technology will also have a profound impact on international technological and economic development.Therefore,for the healthy and orderly development and real implementation of the blockchain industry,standardize the application of blockchain,effectively break through the cognitive and technical barriers between different countries,industries and systems on a global scale,prevent application risks,the development of the global blockchain industry needs standardization basis,which is particularly important and urgent.A sound standard system is an important key to the successful development of technology,and formulating the right standard at the right time for technology development helps ensure the ease of use and interoperability of the technology.From the perspective of international standardization,this article first introduces the general situation of ISO,ITU-T,IEEE,W3C and other international standardization organizations,and sorts out the status quo of the blockchain standardization working groups of mainstream international standardization organizations.All blockchain-related standards under development have been analyzed for the characteristics of international blockchain technology standards and industry application standards.Through data analysis,the overlaps,differences and conflicts in the field of international blockchain standard formulation are sorted out,and suggestions for blockchain standardization work in the application and development of blockchain technology standardization by international organizations and industries are put forward.The plans and layouts of future international standards are summarized to help the development of the international standardization of blockchain.展开更多
The aim of this work was to develop a liquid chromatography-tandem mass spectrometry method for the determination of milk allergen and egg allergen in food products.Signature peptides GGLEPINFQTAADQAR,VGINYWLAHK,VLVLD...The aim of this work was to develop a liquid chromatography-tandem mass spectrometry method for the determination of milk allergen and egg allergen in food products.Signature peptides GGLEPINFQTAADQAR,VGINYWLAHK,VLVLDTDYK,FFVAPFPEVFGK,and NAVPITPTLNR were confirmed and synthesized as the quantitative peptide of ovalbumin,α-lactalbumin,β-lactoglobulin,α_(S1)-casein andα_(S2)-casein,the relative isotope-labeled internal standards were used in the quantitative analysis.Linear range was in the range of0.5-5000.0 nmol/L for egg and milk allergen in bread,cake,cookie,rice crust and wheat flour samples with free from egg and milk,the limits of detection of milk allergens and egg allergen were in the range between0.94 mg/100 g and 56.71 mg/100 g,limits of quantification of milk allergens and egg allergen were in the range between 2.36 mg/100 g and 141.78 mg/100 g.The recoveries ranged from 76.7%to 122.8%,the relative standard deviations were in the range of 1.60%-15.60%.The developed method has been successfully used for the detection of egg and milk allergen in various food samples.展开更多
Rapid online analysis of liquid slag is essential for optimizing the quality and energy efficiency of steel production. To investigate the key factors that affect the online measurement of refined slag using laser-ind...Rapid online analysis of liquid slag is essential for optimizing the quality and energy efficiency of steel production. To investigate the key factors that affect the online measurement of refined slag using laser-induced breakdown spectroscopy(LIBS), this study examined the effects of slag composition and temperature on the intensity and stability of the LIBS spectra. The experimental temperature was controlled at three levels: 1350℃, 1400℃, and 1450℃. The results showed that slag composition and temperature significantly affected the intensity and stability of the LIBS spectra. Increasing the Fe content and temperature in the slag reduces its viscosity, resulting in an enhanced intensity and stability of the LIBS spectra. Additionally, 42 refined slag samples were quantitatively analyzed for Fe, Si, Ca, Mg, Al, and Mn at 1350℃, 1400℃, and 1450℃.The normalized full spectrum combined with partial least squares(PLS) quantification modeling was used, using the Ca Ⅱ 317.91 nm spectral line as an internal standard. The results show that using the internal standard normalization method can significantly reduce the influence of spectral fluctuations. Meanwhile, a temperature of 1450℃ has been found to yield superior results compared to both 1350℃ and 1400℃, and it is advantageous to conduct a quantitative analysis of the slag when it is in a “water-like” state with low viscosity.展开更多
[Objective]This study was to establish a rapid,specific and simple method for quantitative determination of tetrachlorantraniliprole by 1H NMR.[Method]1H NMR spectroscopy was acquired with deuterium DMSO as the solven...[Objective]This study was to establish a rapid,specific and simple method for quantitative determination of tetrachlorantraniliprole by 1H NMR.[Method]1H NMR spectroscopy was acquired with deuterium DMSO as the solvent and maleic acid as internal standard under the conditions of temperature 25℃,pulses width 8.0μs,delay time 5 s,and scanning times 8.[Result]The hydrogen proton peaks of tetrachlorantraniliprole(δ=10.55)and maleic acid(δ=6.27)were taken as quantitative peaks.The peak area ratio y(As/Ar)and mass ratio x(ms/mr)were linearly regressed,and the correlation coefficient was 0.9999.The RSD value of repeatability test was 0.38%,and the RSD value of stability test was 0.77%.The content of tetrachlorantraniliprole was determined as 99.6%.[Conclusion]1H NMR spectroscopy can be used for quantitative determination of tetrachlorantraniliprole without standard reference,which is rapid,accurate and simple.展开更多
International Electrotechnical Commission (IEC), one of the currently worlswide largest and most authoritative international standardization organizations,is specialized in developing and promulgating internationa... International Electrotechnical Commission (IEC), one of the currently worlswide largest and most authoritative international standardization organizations,is specialized in developing and promulgating international standards for the electric and electronic fields, which are widespread adopted through out the world and play an important role in the international trade of electric and electronic products. Moreover, according to the 2005 statistics by the World Bank, the population of countries participating in the IEC activities accounts for 92% of the world total and their trade volume accounts for 95% of the global total. ……展开更多
Year 2006 is the year marking the 100th anniversary of the founding of International Electrotechnical Commission (IEC). IEC is mainly engaged in the international standardization for electrical and electronic tech... Year 2006 is the year marking the 100th anniversary of the founding of International Electrotechnical Commission (IEC). IEC is mainly engaged in the international standardization for electrical and electronic technology field aiming at promoting international trade and technology cooperation and exchange, improving product and service quality, upgrading productivity and protecting the environment as well as human health and safety. Most countries worldwide adopt standards developed and promulgated by IEC, providing a platform to international trade and technical exchange. China has being a member since 1957. Electronic and IT are the most developed and energetic filed in recent decades. Number of IEC TC/SC specialized in electronic and IT amounts up to 52.……展开更多
Chinese electrotechnical industry includes power generation equipment, power transmission and distribution equipment, multi-purpose equipment, and basic electrical material. The industry has 46 national technical ... Chinese electrotechnical industry includes power generation equipment, power transmission and distribution equipment, multi-purpose equipment, and basic electrical material. The industry has 46 national technical committees (TC) and sub-committees (SC), which mirrors to 70 TCs and SCs of International Electrotechnical Commission (IEC). During the past five years, leaded by Standardization Administration of China (SAC),China Electrical Equipment Industry Association (CEEIA) obtained many great achievements in promoting participation of international standardization activities by improving unified management and concentrating industrial strength:……展开更多
The 6th Electrostatic Protection and Standardization International Conference was held on November 10,2017 in Guizhou Normal University on the themes of"promoting the discipline construction of electrostatic prot...The 6th Electrostatic Protection and Standardization International Conference was held on November 10,2017 in Guizhou Normal University on the themes of"promoting the discipline construction of electrostatic protection engineering and accelerating the development of electrostatic protection technology and industry".Experts and representatives held in-depth discussions on theoretical study,technological innovation and achievements and展开更多
The International Electrotechnical Commission(IEC),a global non-profit organization,has evolved its focus to align with changing technological and market trends.This shift involves enhancing internal management struct...The International Electrotechnical Commission(IEC),a global non-profit organization,has evolved its focus to align with changing technological and market trends.This shift involves enhancing internal management structures and processes.In recent years,the IEC has restructured its management,establishing advisory units and promoting a parallel emphasis on technology and market considerations.New governance advisory bodies like the Governance Review and Audit Committee(GRAC)have been introduced.GRAC’s responsibilities encompass auditing,reviewing compliance,ensuring operational security and governance ethics,and addressing financial concerns.The IEC’s commitment to governance excellence is further highlighted by its strategic goals and the work of the Task Force on Long-Term Sustainability(LTS).This paper underscores the IEC’s dual commitment to keeping pace with technological advancements while refining its internal governance structures,emphasizing the importance of both aspects in sustaining its leadership in international standards development.展开更多
In the past two years,significant progresses have been achieved in high-performance cast and wrought magnesium and magnesium alloys,magnesium-based composites,advanced cast technologies,advanced processing technologie...In the past two years,significant progresses have been achieved in high-performance cast and wrought magnesium and magnesium alloys,magnesium-based composites,advanced cast technologies,advanced processing technologies,and functional magnesium materials,such as Mg ion batteries,hydrogen storage Mg materials,bio-magnesium alloys,etc.Great contributions to the development of new magnesium alloys and their processing technologies have been made by Chongqing University,Shanghai Jiaotong University,Chinese Academy of Sciences,Helmholtz Zentrum Geesthacht,Queensland University,Brunel University,etc.This review paper is aimed to summarize the latest important advances in cast magnesium alloys,wrought magnesium alloys and functional magnesium materials worldwide in 2018–2019,including both the development of new materials and the innovation of their processing technologies.Based on the issues and challenges identified here,some future research directions are suggested,including further development of high-performance magnesium alloys having high strength and superior plasticity together with high corrosion resistance and low cost,and fundamental research on the phase diagram,diffusion,precipitation,etc.,as well as the development of advanced welding and joining technology.展开更多
The aim of this work was to develop an automated on-line solid phase extraction(SPE)with liquid chromatography-tandem mass spectrometry method for the detection of fifteen sulfonamides in pork and fish samples.Samples...The aim of this work was to develop an automated on-line solid phase extraction(SPE)with liquid chromatography-tandem mass spectrometry method for the detection of fifteen sulfonamides in pork and fish samples.Samples were extracted with 0.2%formic acid acetonitrile solution,purified by on-line SPE device with HLB column,then separated by XBridge C18 column,using 0.1%formic acid solution and acetonitrile as the mobile phase.Mass spectrometric data was acquired under multiple reaction monitoring(MRM)mode using positive ionization electrospray.Internal standard method was used in the quantification,good linear relationship was got in range of 0.1–100 ng/mL and correlation coefficient was higher than 0.9990.The limits of detection were in the range of 0.125–2.00g/kg and the limits of quantitation were in the range of 0.250–5.00g/kg.Recoveries of the method were in range of 78.3%–99.3%,relative standard deviation were lower than 10%.The method was simple,sensitivity,and could be used for routine supervision and analysis of fifteen sulfonamides in pork and fish.展开更多
An analytical method using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for rapid simultaneous determination of Be, Mg, Al, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Ge, As, Se, Mo, Ag, Cd, Sn, ...An analytical method using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for rapid simultaneous determination of Be, Mg, Al, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Ge, As, Se, Mo, Ag, Cd, Sn, Sb, Ba, Pt, Au and Pb in high purity cobalt was described. Sample digestions were performed in closed microwave vessels using HNO3 and HCl. The matrix effects due to the presence of excess HCl and Co were evaluated. The usefulness of high mass resolution for overcoming some spectral interference was demonstrated. The optimum conditions for the determination was tested and discussed. Correction for matrix effects, Sc, Rh and Bi were used as internal standards. The detection limits is 0.003-0.57 μg/g, the recovery ratio is 92.2%-111.2%, and the RSD is less than 3.6%. The method is accurate, quick and convenient. It has been applied to the determination of trace impurities in high purity cobalt with satisfactory results.展开更多
AIM:To Introduce a new specialized visual acuity chart for amblyopic children aged 3-5 years old and its clinical applications.METHODS:The new visual acuity chart and notations were designed based on Weber-Fechner law...AIM:To Introduce a new specialized visual acuity chart for amblyopic children aged 3-5 years old and its clinical applications.METHODS:The new visual acuity chart and notations were designed based on Weber-Fechner law.The optotypes were red against a white background and were specially shaped four basic geometric symbols:circle,square,triangle,and cross.A regular geometric progression of the optotype sizes and distribution was employed to arrange in 14 lines.The progression rate of the optotype size between two lines was 1.2589 and the testing distance was 3m.Visual acuity score could be recorded as logMAR notation or decimal notation.Agestratified diagnostic criteria for amblyopia established by consensus statement on diagnosis of amblyopia(2011)among members of the Strabismus and Pediatric Ophthalmology Group,Ophthalmology Society,Chinese Medical Association(SPOGOSCMA)were illustrated in the new visual acuity chart.RESULTS:When assessing visual acuity in children aged 3-5 years old,this new visual acuity chart that consists of four symmetrical shapes(triangle,square,cross,and circle)overcame an inability to recognize the letters of the alphabet and difficulties in designating the direction of black abstract symbols such as the tumbling’E’or Landolt’C’,which the subjects were prone to lose interest in.The visual acuity score may be recorded indifferent notations:decimal acuity and logMAR.These two notations can be easily converted each other in the new eye chart.The measurements of this new chart not only showed a significant correlation and a good consistency with the international standard logarithmic visual acuity chart(r=0.932,P【0.01),but also indicated a high test-retest reliability(89%of retest scores were within 0.1 logMAR units of the initial test score).CONCLUSION:The results of this study support the validity and reliability of distance visual acuity measurements using the new eye chart in children aged3 to 5 years over a wide range of visual acuities,and the new eye chart is great for early detection of amblyopia.It can be applied in various clinical settings.展开更多
This papcr presents a comparison between the Chinese Code GB50011-2001 and the International Standard ISO3010:2001(E),emphasizing the similarities and differences related to design requirements,seismic actions and ana...This papcr presents a comparison between the Chinese Code GB50011-2001 and the International Standard ISO3010:2001(E),emphasizing the similarities and differences related to design requirements,seismic actions and analytical approaches.Similarities include:earthquake return period,conceptual design,site classification,structural strength and ductility requirements,deformation limits,response spectra,seismic analysis procedures,isolation and energy dissipation, and nonstructural elements.Differences exist in the following areas:seismic levels,earthquake loading,mode damping factors and structural control.展开更多
AIMTo evaluate Jordanian ophthalmology residency programs in achieving competencies outlined by the International Council of Ophthalmology (ICO) and residents' satisfaction with available training programs in Jord...AIMTo evaluate Jordanian ophthalmology residency programs in achieving competencies outlined by the International Council of Ophthalmology (ICO) and residents' satisfaction with available training programs in Jordan, and to highlight weakness points that may be improved and strengthened.展开更多
The sugar standard implemented under specific historical conditions had played a positive role in standardizing the production of China's sugar industry,promoting the development of sugar industry and strengthenin...The sugar standard implemented under specific historical conditions had played a positive role in standardizing the production of China's sugar industry,promoting the development of sugar industry and strengthening the quality management of sugar products.This paper systematically combs the development of national standard and industrial standard of white granulated sugar,and analyzes the technical requirements such as sensory indicators,physical and chemical indicators and health indicators.From the development of China's white granulated sugar product standard,the sucrose content of the same level of white granulated sugar has not been adjusted,while the standard for indexes other than sucrose content,have been improved to meet the needs of the development of China's sugar industry and the development of domestic and foreign trade.Through comparison with the international standard of white granulated sugar,it is concluded that China’s national standard of white granulated sugar has kept pace with international standard.展开更多
基金supported by Open Research Fund of State Key Laboratory of Pulsed Power Laser Technology of China(No.SKL2013KF03)National Natural Science Foundation of China(Nos.51206055,51476061)+3 种基金the Fundamental Research Funds for the Central Universities of China(No.2014ZZ0014)the New Star of Pearl River on Science and Technology of Guangzhou,China(No.2014J2200054)the Key Laboratory of Efficient and Clean Energy Utilization of Guangdong Higher Education Institutes of China(No.KLB10004)Guangdong Province Key Laboratory of Efficient and Clean Energy Utilization,China(No.2013A061401005)
文摘Laser-induced breakdown spectroscopy was employed to determine the inorganic elements in coal. To improve the measurement's accuracy and precision, a new internal standardization scheme, which we named changed internal standardization, was compared with the traditional internal standardization and no internal standardization for the analysis of inorganic elements. The new internal standardization scheme used the atomic line of carbon at 247.86 nm and the molecular band of CN at 388.34 nm and C2 at 516.32 nm to normalize the lines of inorganic elements that were distributed in the same spectral channel. The performance of the utilization of the new internal standardization scheme was evaluated using a set of coal samples, including twenty calibration samples and five validation samples. The results show that the coefficients of determination R2 and the slope of calibration models coupled with changed internal standard- ization are better than that of the calibration models coupled with fixed internal standardization and no internal standardization. Moreover, the measurement accuracy and reproducibility of changed internal standardization for the analysis of five validation samples also yielded further improvement. The results that we obtained suggest that changed internal standardization could compensate for the matrix effects, as well as the influence of the difference in the spectral response of the light collection system.
基金Supported by the China Instrumentation Program(No.2011YQ030113) and the National Natural Science Foundation of China (Nos.21175106, 21375105).
文摘The external calibration in conjunction with internal standardization(ECIS) coupled with laser-induced breakdown spectroscopic(LIBS) technique was proposed to perform the quantitative analysis of Fe content in iron ore The plasma temperature and the electron number density were calculated to prove that the plasma was under local thermodynamic equilibrium(LTE) conditions and to ensure that the integral intensities of Fe I lines were reasonable. In addition, the result of the quantitative analysis shows a content of (20.26±0.59)% by mass of Fe in the iron ore. It was determined by four calibration curves, drawn for four emission lines of Fe I(373.48, 373.71,404.58 and 438.35 nm) normalized by Mn I line, base on the ECIS method which can eliminate the influence of matrix effect and improve the accuracy of quantitative analysis, compared with the standard addition method. Both the results of these two analytical methods were compared with that listed in the Standard Substance Certificate. The percentage content of Fe in the same sample of iron ore by the ECIS method was (20.17±0.08)% by mass, which shows a good performance to analyze the Fe content of iron ore in combination with LIBS.
基金supported by the Key R&D Program of Zhejiang Province(2021C01105)the Key R&D Program of Guangdong Province(2020B0101090003)+1 种基金the National Key R&D Program of China(2021YFB2701100)These supports are gratefully acknowledged.
文摘As one of the most concerned digital technologies in recent years,blockchain and distributed ledger technology are an important driving force for a new round of technological development.It is currently in the process of accelerating its evolution and maturity,and has gradually integrated with other digital technologies.It has been applied in many industries,providing decentralized solutions for various industries,realizing innovative storage models,and building a new trust system.As blockchain technology is officially incorporated into China’s new information infrastructure category,the application fields of blockchain have expanded rapidly,gradually extending from the financial field and government affairs to other fields in the real economy.At the same time,with the continuous development of the globalized economy,blockchain technology will also have a profound impact on international technological and economic development.Therefore,for the healthy and orderly development and real implementation of the blockchain industry,standardize the application of blockchain,effectively break through the cognitive and technical barriers between different countries,industries and systems on a global scale,prevent application risks,the development of the global blockchain industry needs standardization basis,which is particularly important and urgent.A sound standard system is an important key to the successful development of technology,and formulating the right standard at the right time for technology development helps ensure the ease of use and interoperability of the technology.From the perspective of international standardization,this article first introduces the general situation of ISO,ITU-T,IEEE,W3C and other international standardization organizations,and sorts out the status quo of the blockchain standardization working groups of mainstream international standardization organizations.All blockchain-related standards under development have been analyzed for the characteristics of international blockchain technology standards and industry application standards.Through data analysis,the overlaps,differences and conflicts in the field of international blockchain standard formulation are sorted out,and suggestions for blockchain standardization work in the application and development of blockchain technology standardization by international organizations and industries are put forward.The plans and layouts of future international standards are summarized to help the development of the international standardization of blockchain.
基金supported by National Key Research and Development Program of China(2019YFC1606400)Science and Technology Project of State Administration for Market Regulation(2021MK023)+1 种基金Hebei Province High-level Talent Funding Program(A201901008)Research Project of Hebei Administration for Market Regulation(2020ZD12)。
文摘The aim of this work was to develop a liquid chromatography-tandem mass spectrometry method for the determination of milk allergen and egg allergen in food products.Signature peptides GGLEPINFQTAADQAR,VGINYWLAHK,VLVLDTDYK,FFVAPFPEVFGK,and NAVPITPTLNR were confirmed and synthesized as the quantitative peptide of ovalbumin,α-lactalbumin,β-lactoglobulin,α_(S1)-casein andα_(S2)-casein,the relative isotope-labeled internal standards were used in the quantitative analysis.Linear range was in the range of0.5-5000.0 nmol/L for egg and milk allergen in bread,cake,cookie,rice crust and wheat flour samples with free from egg and milk,the limits of detection of milk allergens and egg allergen were in the range between0.94 mg/100 g and 56.71 mg/100 g,limits of quantification of milk allergens and egg allergen were in the range between 2.36 mg/100 g and 141.78 mg/100 g.The recoveries ranged from 76.7%to 122.8%,the relative standard deviations were in the range of 1.60%-15.60%.The developed method has been successfully used for the detection of egg and milk allergen in various food samples.
基金financially supported by the National Key R&D Program Projects of China (No.2021YFB3202402)National Natural Science Foundation of China (No.62173321)。
文摘Rapid online analysis of liquid slag is essential for optimizing the quality and energy efficiency of steel production. To investigate the key factors that affect the online measurement of refined slag using laser-induced breakdown spectroscopy(LIBS), this study examined the effects of slag composition and temperature on the intensity and stability of the LIBS spectra. The experimental temperature was controlled at three levels: 1350℃, 1400℃, and 1450℃. The results showed that slag composition and temperature significantly affected the intensity and stability of the LIBS spectra. Increasing the Fe content and temperature in the slag reduces its viscosity, resulting in an enhanced intensity and stability of the LIBS spectra. Additionally, 42 refined slag samples were quantitatively analyzed for Fe, Si, Ca, Mg, Al, and Mn at 1350℃, 1400℃, and 1450℃.The normalized full spectrum combined with partial least squares(PLS) quantification modeling was used, using the Ca Ⅱ 317.91 nm spectral line as an internal standard. The results show that using the internal standard normalization method can significantly reduce the influence of spectral fluctuations. Meanwhile, a temperature of 1450℃ has been found to yield superior results compared to both 1350℃ and 1400℃, and it is advantageous to conduct a quantitative analysis of the slag when it is in a “water-like” state with low viscosity.
文摘[Objective]This study was to establish a rapid,specific and simple method for quantitative determination of tetrachlorantraniliprole by 1H NMR.[Method]1H NMR spectroscopy was acquired with deuterium DMSO as the solvent and maleic acid as internal standard under the conditions of temperature 25℃,pulses width 8.0μs,delay time 5 s,and scanning times 8.[Result]The hydrogen proton peaks of tetrachlorantraniliprole(δ=10.55)and maleic acid(δ=6.27)were taken as quantitative peaks.The peak area ratio y(As/Ar)and mass ratio x(ms/mr)were linearly regressed,and the correlation coefficient was 0.9999.The RSD value of repeatability test was 0.38%,and the RSD value of stability test was 0.77%.The content of tetrachlorantraniliprole was determined as 99.6%.[Conclusion]1H NMR spectroscopy can be used for quantitative determination of tetrachlorantraniliprole without standard reference,which is rapid,accurate and simple.
文摘 International Electrotechnical Commission (IEC), one of the currently worlswide largest and most authoritative international standardization organizations,is specialized in developing and promulgating international standards for the electric and electronic fields, which are widespread adopted through out the world and play an important role in the international trade of electric and electronic products. Moreover, according to the 2005 statistics by the World Bank, the population of countries participating in the IEC activities accounts for 92% of the world total and their trade volume accounts for 95% of the global total. ……
文摘 Year 2006 is the year marking the 100th anniversary of the founding of International Electrotechnical Commission (IEC). IEC is mainly engaged in the international standardization for electrical and electronic technology field aiming at promoting international trade and technology cooperation and exchange, improving product and service quality, upgrading productivity and protecting the environment as well as human health and safety. Most countries worldwide adopt standards developed and promulgated by IEC, providing a platform to international trade and technical exchange. China has being a member since 1957. Electronic and IT are the most developed and energetic filed in recent decades. Number of IEC TC/SC specialized in electronic and IT amounts up to 52.……
文摘 Chinese electrotechnical industry includes power generation equipment, power transmission and distribution equipment, multi-purpose equipment, and basic electrical material. The industry has 46 national technical committees (TC) and sub-committees (SC), which mirrors to 70 TCs and SCs of International Electrotechnical Commission (IEC). During the past five years, leaded by Standardization Administration of China (SAC),China Electrical Equipment Industry Association (CEEIA) obtained many great achievements in promoting participation of international standardization activities by improving unified management and concentrating industrial strength:……
文摘The 6th Electrostatic Protection and Standardization International Conference was held on November 10,2017 in Guizhou Normal University on the themes of"promoting the discipline construction of electrostatic protection engineering and accelerating the development of electrostatic protection technology and industry".Experts and representatives held in-depth discussions on theoretical study,technological innovation and achievements and
文摘The International Electrotechnical Commission(IEC),a global non-profit organization,has evolved its focus to align with changing technological and market trends.This shift involves enhancing internal management structures and processes.In recent years,the IEC has restructured its management,establishing advisory units and promoting a parallel emphasis on technology and market considerations.New governance advisory bodies like the Governance Review and Audit Committee(GRAC)have been introduced.GRAC’s responsibilities encompass auditing,reviewing compliance,ensuring operational security and governance ethics,and addressing financial concerns.The IEC’s commitment to governance excellence is further highlighted by its strategic goals and the work of the Task Force on Long-Term Sustainability(LTS).This paper underscores the IEC’s dual commitment to keeping pace with technological advancements while refining its internal governance structures,emphasizing the importance of both aspects in sustaining its leadership in international standards development.
基金The content in this review is financially supported by the National Key Research and Development Program of China(No.2016YFB0301100,2017YFF0209100)the National Science Foundation for Scientists of China(No.51531002,51474043,51701027,51971042,51901028)the Chongqing Academician Special Fund(cstc2018jcyj-yszxX0007,cstc2019yszxjcyjX0004).
文摘In the past two years,significant progresses have been achieved in high-performance cast and wrought magnesium and magnesium alloys,magnesium-based composites,advanced cast technologies,advanced processing technologies,and functional magnesium materials,such as Mg ion batteries,hydrogen storage Mg materials,bio-magnesium alloys,etc.Great contributions to the development of new magnesium alloys and their processing technologies have been made by Chongqing University,Shanghai Jiaotong University,Chinese Academy of Sciences,Helmholtz Zentrum Geesthacht,Queensland University,Brunel University,etc.This review paper is aimed to summarize the latest important advances in cast magnesium alloys,wrought magnesium alloys and functional magnesium materials worldwide in 2018–2019,including both the development of new materials and the innovation of their processing technologies.Based on the issues and challenges identified here,some future research directions are suggested,including further development of high-performance magnesium alloys having high strength and superior plasticity together with high corrosion resistance and low cost,and fundamental research on the phase diagram,diffusion,precipitation,etc.,as well as the development of advanced welding and joining technology.
基金This work was supported by“National Key Research and Development Program of China”(Project No.2018YFC1603400)Science and Technology Program of Hebei Province(Project No.19225503D).
文摘The aim of this work was to develop an automated on-line solid phase extraction(SPE)with liquid chromatography-tandem mass spectrometry method for the detection of fifteen sulfonamides in pork and fish samples.Samples were extracted with 0.2%formic acid acetonitrile solution,purified by on-line SPE device with HLB column,then separated by XBridge C18 column,using 0.1%formic acid solution and acetonitrile as the mobile phase.Mass spectrometric data was acquired under multiple reaction monitoring(MRM)mode using positive ionization electrospray.Internal standard method was used in the quantification,good linear relationship was got in range of 0.1–100 ng/mL and correlation coefficient was higher than 0.9990.The limits of detection were in the range of 0.125–2.00g/kg and the limits of quantitation were in the range of 0.250–5.00g/kg.Recoveries of the method were in range of 78.3%–99.3%,relative standard deviation were lower than 10%.The method was simple,sensitivity,and could be used for routine supervision and analysis of fifteen sulfonamides in pork and fish.
基金supported by the Natural Science Foundation of Hunan Province(No.05JJ40017)Education Department of Hunan Province(No.05B064).
文摘An analytical method using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for rapid simultaneous determination of Be, Mg, Al, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Ge, As, Se, Mo, Ag, Cd, Sn, Sb, Ba, Pt, Au and Pb in high purity cobalt was described. Sample digestions were performed in closed microwave vessels using HNO3 and HCl. The matrix effects due to the presence of excess HCl and Co were evaluated. The usefulness of high mass resolution for overcoming some spectral interference was demonstrated. The optimum conditions for the determination was tested and discussed. Correction for matrix effects, Sc, Rh and Bi were used as internal standards. The detection limits is 0.003-0.57 μg/g, the recovery ratio is 92.2%-111.2%, and the RSD is less than 3.6%. The method is accurate, quick and convenient. It has been applied to the determination of trace impurities in high purity cobalt with satisfactory results.
文摘AIM:To Introduce a new specialized visual acuity chart for amblyopic children aged 3-5 years old and its clinical applications.METHODS:The new visual acuity chart and notations were designed based on Weber-Fechner law.The optotypes were red against a white background and were specially shaped four basic geometric symbols:circle,square,triangle,and cross.A regular geometric progression of the optotype sizes and distribution was employed to arrange in 14 lines.The progression rate of the optotype size between two lines was 1.2589 and the testing distance was 3m.Visual acuity score could be recorded as logMAR notation or decimal notation.Agestratified diagnostic criteria for amblyopia established by consensus statement on diagnosis of amblyopia(2011)among members of the Strabismus and Pediatric Ophthalmology Group,Ophthalmology Society,Chinese Medical Association(SPOGOSCMA)were illustrated in the new visual acuity chart.RESULTS:When assessing visual acuity in children aged 3-5 years old,this new visual acuity chart that consists of four symmetrical shapes(triangle,square,cross,and circle)overcame an inability to recognize the letters of the alphabet and difficulties in designating the direction of black abstract symbols such as the tumbling’E’or Landolt’C’,which the subjects were prone to lose interest in.The visual acuity score may be recorded indifferent notations:decimal acuity and logMAR.These two notations can be easily converted each other in the new eye chart.The measurements of this new chart not only showed a significant correlation and a good consistency with the international standard logarithmic visual acuity chart(r=0.932,P【0.01),but also indicated a high test-retest reliability(89%of retest scores were within 0.1 logMAR units of the initial test score).CONCLUSION:The results of this study support the validity and reliability of distance visual acuity measurements using the new eye chart in children aged3 to 5 years over a wide range of visual acuities,and the new eye chart is great for early detection of amblyopia.It can be applied in various clinical settings.
文摘This papcr presents a comparison between the Chinese Code GB50011-2001 and the International Standard ISO3010:2001(E),emphasizing the similarities and differences related to design requirements,seismic actions and analytical approaches.Similarities include:earthquake return period,conceptual design,site classification,structural strength and ductility requirements,deformation limits,response spectra,seismic analysis procedures,isolation and energy dissipation, and nonstructural elements.Differences exist in the following areas:seismic levels,earthquake loading,mode damping factors and structural control.
基金Supported in part by an unrestricted grant from Research to Prevent Blindness,Inc.New York,N.Y,USA
文摘AIMTo evaluate Jordanian ophthalmology residency programs in achieving competencies outlined by the International Council of Ophthalmology (ICO) and residents' satisfaction with available training programs in Jordan, and to highlight weakness points that may be improved and strengthened.
文摘The sugar standard implemented under specific historical conditions had played a positive role in standardizing the production of China's sugar industry,promoting the development of sugar industry and strengthening the quality management of sugar products.This paper systematically combs the development of national standard and industrial standard of white granulated sugar,and analyzes the technical requirements such as sensory indicators,physical and chemical indicators and health indicators.From the development of China's white granulated sugar product standard,the sucrose content of the same level of white granulated sugar has not been adjusted,while the standard for indexes other than sucrose content,have been improved to meet the needs of the development of China's sugar industry and the development of domestic and foreign trade.Through comparison with the international standard of white granulated sugar,it is concluded that China’s national standard of white granulated sugar has kept pace with international standard.