In the test, internal inlay drip irrigation pipes with different wal thicknesses or diameters (¢at 12 mm and 16 mm) were tested under varying tension forces and it was concluded that 90 N is the rational one. What...In the test, internal inlay drip irrigation pipes with different wal thicknesses or diameters (¢at 12 mm and 16 mm) were tested under varying tension forces and it was concluded that 90 N is the rational one. What’s more, the smal er drip-irrigation inner diameter, the thinner wal thickness, and the higher tension force, the lower acceptability, and the larger drip-irrigation inner diameter, the thicker wal thickness, and the lower tension force, the higher acceptability. The causes were analyzed in the research, including manufacturing technique leading to disqualifica-tion and different specifications with the same demands on techniques, and inadap-tation to tension force at 130 N.展开更多
文摘In the test, internal inlay drip irrigation pipes with different wal thicknesses or diameters (¢at 12 mm and 16 mm) were tested under varying tension forces and it was concluded that 90 N is the rational one. What’s more, the smal er drip-irrigation inner diameter, the thinner wal thickness, and the higher tension force, the lower acceptability, and the larger drip-irrigation inner diameter, the thicker wal thickness, and the lower tension force, the higher acceptability. The causes were analyzed in the research, including manufacturing technique leading to disqualifica-tion and different specifications with the same demands on techniques, and inadap-tation to tension force at 130 N.