AIM: To evaluate the intraocular pressure(IOP)measurements by Icare rebound tonometer over a contact lens in comparison with Goldmann applanation tonometry(GAT). METHODS: Fifty patients using contact lens were include...AIM: To evaluate the intraocular pressure(IOP)measurements by Icare rebound tonometer over a contact lens in comparison with Goldmann applanation tonometry(GAT). METHODS: Fifty patients using contact lens were included in this study. One of the eyes of the patients was selected randomly and their IOP were measured by rebound tonometer with and without contact lens(RTCL,RT respectively) and by GAT, as well as their central corneal thickness(CCT) by optical pachymeter. The results of both methods were compared by correlation analysis, general linear method repeated measure and Bland-Altman analysis.RESULTS: Mean IOP values measured by RTCL, RT and GAT were 15.68 ±3.7, 14.50 ±3.4 and 14.16 ±2.8(P 【0.001), respectively. Mean IOP by RTCL was significantly higher than the measurements implemented by RT and GAT(P 【0.001), while there was no difference between the measurements by GAT and RT(P =0.629). There was a good level of positive correlation between GAT and RTCL as well as RT(r =0.786 P 【0.001, r =0.833 P 【0.001, respectively). We have observed that CCT increase did not show any correlation with the differences of the measurements between RTCL and RT(P =0.329), RTCL and GAT(P =0.07) as well as RT and GAT(P =0.189) in linear regression model.CONCLUSION: The average of the measurements over contact lens by rebound tonometer was found to be higher than what was measured by GAT. Although this difference is statistically significant, it may be clinically negligible in the normal population.展开更多
AIM:To introduce a novel approach in removal of anterior chamber angle foreign body(ACFB) using a prism contact lens and 23-gauge foreign body forceps.METHODS:Data of 42 eyes of 42 patients who had undergone remov...AIM:To introduce a novel approach in removal of anterior chamber angle foreign body(ACFB) using a prism contact lens and 23-gauge foreign body forceps.METHODS:Data of 42 eyes of 42 patients who had undergone removal of ACFB using a prism contact lens and 23-gauge foreign body forceps from January 2008 to October 2013 were collected and analyzed. Twenty eyes in group A received the conventional approach by using toothed forceps through corneal limbus incision, and 22 eyes in group B underwent the novel method through the opposite corneal limbus incision. RESULTS:The success rate of ACFB once removal was 75%(15/20) in group A, and 100%(22/22) in group B. The average operation time of group A was significantly longer compared with group B(34.9±9.88 min vs 22.13±8.85min; P〈0.05). The average size of corneal limbus incision in group A was significantly larger than that of group B(4.85±1.89 mm vs 3.95±1.17 mm; P〈0.05). The corneal limbus incision suturing were conducted in all eyes in group A, and only 5 eyes in group B. CONCLUSION:Removal of ACFB using a prism contact lens and 23-gauge foreign body forceps is a safer, more effective, and convenient technique compared with the conventional approach.展开更多
AIM:To evaluate the refractive correction for standard automated perimetry(SAP)in eyes with refractive multifocal contact lenses(CL)in healthy young participants.METHODS:Twenty-nine eyes of 29 participants were ...AIM:To evaluate the refractive correction for standard automated perimetry(SAP)in eyes with refractive multifocal contact lenses(CL)in healthy young participants.METHODS:Twenty-nine eyes of 29 participants were included.Accommodation was paralyzed in all participants with 1%cyclopentolate hydrochloride.SAP was performed using the Humphrey SITA-standard 24-2 and 10-2 protocol under three refractive conditions:monofocal CL corrected for near distance(baseline);multifocal CL corrected for distance(m CL-D);and m CL-D corrected for near vision using a spectacle lens(m CL-N).Primary outcome measures were the foveal threshold,mean deviation(MD),and pattern standard deviation(PSD).RESULTS:The foveal threshold of m CL-N with both the24-2 and 10-2 protocols significantly decreased by 2.2-2.5 d B(P〈0.001),while that of m CL-D with the 24-2 protocol significantly decreased by 1.5 d B(P=0.0427),as compared with that of baseline.Although there was no significant difference between the MD of baseline and m CL-D with the24-2 and 10-2 protocols,the MD of m CL-N was significantly decreased by 1.0-1.3 d B(P〈0.001)as compared with that of both baseline and m CL-D,with both 24-2 and 10-2 protocols.There was no significant difference in the PSD among the three refractive conditions with both the 24-2 and 10-2 protocols.CONCLUSION:Despite the induced mydriasis and the optical design of the multifocal lens used in this study,our results indicated that,when the dome-shaped visual field test is performed with eyes with large pupils and wearing refractive multifocal CLs,distance correction without additional near correction is to be recommended.展开更多
Dear Editor,I am Dr.Ye Shen from the Department of Ophthalmology,the First Affiliated Hospital,College of Medicine,Zhejiang University,Hangzhou,China.I write to share my experience of full-vision maintenance in patien...Dear Editor,I am Dr.Ye Shen from the Department of Ophthalmology,the First Affiliated Hospital,College of Medicine,Zhejiang University,Hangzhou,China.I write to share my experience of full-vision maintenance in patient with extrahigh myopia from implantable collamer lens (ICL) to trifocal intraocular lens (IOL) implantation.展开更多
文摘AIM: To evaluate the intraocular pressure(IOP)measurements by Icare rebound tonometer over a contact lens in comparison with Goldmann applanation tonometry(GAT). METHODS: Fifty patients using contact lens were included in this study. One of the eyes of the patients was selected randomly and their IOP were measured by rebound tonometer with and without contact lens(RTCL,RT respectively) and by GAT, as well as their central corneal thickness(CCT) by optical pachymeter. The results of both methods were compared by correlation analysis, general linear method repeated measure and Bland-Altman analysis.RESULTS: Mean IOP values measured by RTCL, RT and GAT were 15.68 ±3.7, 14.50 ±3.4 and 14.16 ±2.8(P 【0.001), respectively. Mean IOP by RTCL was significantly higher than the measurements implemented by RT and GAT(P 【0.001), while there was no difference between the measurements by GAT and RT(P =0.629). There was a good level of positive correlation between GAT and RTCL as well as RT(r =0.786 P 【0.001, r =0.833 P 【0.001, respectively). We have observed that CCT increase did not show any correlation with the differences of the measurements between RTCL and RT(P =0.329), RTCL and GAT(P =0.07) as well as RT and GAT(P =0.189) in linear regression model.CONCLUSION: The average of the measurements over contact lens by rebound tonometer was found to be higher than what was measured by GAT. Although this difference is statistically significant, it may be clinically negligible in the normal population.
文摘AIM:To introduce a novel approach in removal of anterior chamber angle foreign body(ACFB) using a prism contact lens and 23-gauge foreign body forceps.METHODS:Data of 42 eyes of 42 patients who had undergone removal of ACFB using a prism contact lens and 23-gauge foreign body forceps from January 2008 to October 2013 were collected and analyzed. Twenty eyes in group A received the conventional approach by using toothed forceps through corneal limbus incision, and 22 eyes in group B underwent the novel method through the opposite corneal limbus incision. RESULTS:The success rate of ACFB once removal was 75%(15/20) in group A, and 100%(22/22) in group B. The average operation time of group A was significantly longer compared with group B(34.9±9.88 min vs 22.13±8.85min; P〈0.05). The average size of corneal limbus incision in group A was significantly larger than that of group B(4.85±1.89 mm vs 3.95±1.17 mm; P〈0.05). The corneal limbus incision suturing were conducted in all eyes in group A, and only 5 eyes in group B. CONCLUSION:Removal of ACFB using a prism contact lens and 23-gauge foreign body forceps is a safer, more effective, and convenient technique compared with the conventional approach.
基金Supported by School of Allied Health Sciences,Kitasato University,Kanagawa,Japan
文摘AIM:To evaluate the refractive correction for standard automated perimetry(SAP)in eyes with refractive multifocal contact lenses(CL)in healthy young participants.METHODS:Twenty-nine eyes of 29 participants were included.Accommodation was paralyzed in all participants with 1%cyclopentolate hydrochloride.SAP was performed using the Humphrey SITA-standard 24-2 and 10-2 protocol under three refractive conditions:monofocal CL corrected for near distance(baseline);multifocal CL corrected for distance(m CL-D);and m CL-D corrected for near vision using a spectacle lens(m CL-N).Primary outcome measures were the foveal threshold,mean deviation(MD),and pattern standard deviation(PSD).RESULTS:The foveal threshold of m CL-N with both the24-2 and 10-2 protocols significantly decreased by 2.2-2.5 d B(P〈0.001),while that of m CL-D with the 24-2 protocol significantly decreased by 1.5 d B(P=0.0427),as compared with that of baseline.Although there was no significant difference between the MD of baseline and m CL-D with the24-2 and 10-2 protocols,the MD of m CL-N was significantly decreased by 1.0-1.3 d B(P〈0.001)as compared with that of both baseline and m CL-D,with both 24-2 and 10-2 protocols.There was no significant difference in the PSD among the three refractive conditions with both the 24-2 and 10-2 protocols.CONCLUSION:Despite the induced mydriasis and the optical design of the multifocal lens used in this study,our results indicated that,when the dome-shaped visual field test is performed with eyes with large pupils and wearing refractive multifocal CLs,distance correction without additional near correction is to be recommended.
基金Supported partly by the General Natural Science Projects,Department of Education,Zhejiang Province,China(No.Y201636718)
文摘Dear Editor,I am Dr.Ye Shen from the Department of Ophthalmology,the First Affiliated Hospital,College of Medicine,Zhejiang University,Hangzhou,China.I write to share my experience of full-vision maintenance in patient with extrahigh myopia from implantable collamer lens (ICL) to trifocal intraocular lens (IOL) implantation.