期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Starting Characteristics of Motor in Inverter-Motor Drive System 被引量:1
1
作者 Xi-jun Yang Xiang-jun Zhang You-min Gong 《Advances in Manufacturing》 2000年第2期140-144,共5页
When the induction motor is fed from the PWM VSI inverter, with and without torque enhancing function, the variations of the starting torque and the starting current versus the starting frequency are analyzed, base... When the induction motor is fed from the PWM VSI inverter, with and without torque enhancing function, the variations of the starting torque and the starting current versus the starting frequency are analyzed, based on the steady state equivalent circuit of the induction motor.The corresponding expressions are derived, and the corresponding curves are also drawn, from which the initial starting frequency range can be determined properly and easily. The initial starting frequency range is the common range, in which the starting torque should be high enough and the starting current low enough.Some other useful formulas are also derived.These results are significant for electrical drive designers to make the starting schemes. The effects of the increase of the stator and the rotor resistances on the starting torque and the initial starting frequency range are also discussed, which is caused by the skin effects of the high order harmonics present in the PWM inverter output voltage. 展开更多
关键词 inverter motor drive system starting characteristics skin effect
下载PDF
Three-level inverter configuration with common mode voltage elimination for induction motor drive (To continue)
2
《变频器世界》 2006年第5期27-28,共2页
The multiplicity of vector combinations for vectors of combined three-level inverters plays an important role, when deciding on the modulation scheme, to obtain minimum switching per inverter vector change, as describ... The multiplicity of vector combinations for vectors of combined three-level inverters plays an important role, when deciding on the modulation scheme, to obtain minimum switching per inverter vector change, as described in the next Section. This is not possible with reduced common-mode three-level inverter structure, obtained with a five-level cascaded H-bridge configuration, as the space vectors locations do not exhibit multiplicity. Moreover, the proposed configuration requires only two power supplies, whereas the scheme with the five-level H-bridge configuration requires six isolated power supplies. 展开更多
关键词 MODE To continue Three-level inverter configuration with common mode voltage elimination for induction motor drive
下载PDF
Three-level inverter configuration with common mode voltage elimination for induction motor drive
3
《变频器世界》 2006年第6期26-27,共2页
The multiplicity of vector combinations for vectors of combined three-level inverters plays an important role, when deciding on the modulation scheme, to obtain minimum switching per inverter vector change, as describ... The multiplicity of vector combinations for vectors of combined three-level inverters plays an important role, when deciding on the modulation scheme, to obtain minimum switching per inverter vector change, as described in the next Section. This is not possible with reduced common-mode three-level inverter structure, obtained with a five-level cascaded H-bridge configuration, as the space vectors locations do not exhibit multiplicity. Moreover, the proposed configuration requires only two power supplies, whereas the scheme with the five-level H-bridge configuration requires six isolated power supplies. 展开更多
关键词 MODE Three-level inverter configuration with common mode voltage elimination for induction motor drive
下载PDF
Calculation of the Losses of Series-Hybrid Powertrains
4
作者 Roland Schmetz 《Journal of Agricultural Science and Technology(A)》 2018年第2期112-119,共8页
Regarding mobile machinery, particularly agricultural tractors, there is an ongoing competition for the most suitable technology to achieve optimum functionality with maximum efficiency. In this competition, the effic... Regarding mobile machinery, particularly agricultural tractors, there is an ongoing competition for the most suitable technology to achieve optimum functionality with maximum efficiency. In this competition, the efficiency of electric series-hybrid powertrains (ESHPs) is often depicted as worse than the efficiency of mechanical-hydraulic power-split powertrains (MHPSPs). On closer inspection of these statements, however, systematic errors, such as unequal balance limits, neglected size effects and nonlinearities, non-observance of recent technical developments and standards, or erroneous application of research results regarding MHPSPs on ESHPs are often evident. For verification (and under avoidance of the systematic errors mentioned above), the losses of an ESHP of 150 kW power are for example calculated and compared with the losses of a typical MHPSP of the same power. The comparison of the losses shows that the ESHP clearly exceeds the efficiency of the comparative MHPSP in the main working range and that there is still potential for improvement. 展开更多
关键词 Electric tractor series-hybrid powertrain electric propulsion calculation of losses mechanical-hydraulic power split drive inverter.
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部