The presence of iodinated X-ray contrast media(ICM) in source waters is of high concern to public health because of their potential to generate highly toxic disinfection by-products(DBPs). The objective of this st...The presence of iodinated X-ray contrast media(ICM) in source waters is of high concern to public health because of their potential to generate highly toxic disinfection by-products(DBPs). The objective of this study was to determine the impact of ICM in source waters and the type of disinfectant on the overall toxicity of DBP mixtures and to determine which ICM and reaction conditions give rise to toxic by-products. Source waters collected from Akron,OH were treated with five different ICMs, including iopamidol, iopromide, iohexol,diatrizoate and iomeprol, with or without chlorine or chloramine disinfection. The reaction product mixtures were concentrated with XAD resins and the mammalian cell cytotoxicity and genotoxicity of the reaction mixture concentrates was measured. Water containing iopamidol generated an enhanced level of mammalian cell cytotoxicity and genotoxicity after disinfection. While chlorine disinfection with iopamidol resulted in the highest cytotoxicity overall, the relative iopamidol-mediated increase in toxicity was greater when chloramine was used as the disinfectant compared with chlorine. Four other ICMs(iopromide, iohexol, diatrizoate, and iomeprol) expressed some cytotoxicity over the control without any disinfection, and induced higher cytotoxicity when chlorinated. Only iohexol enhanced genotoxicity compared to the chlorinated source water.展开更多
BACKGROUND Ischemic stroke is an entity with high incidence,morbidity,and mortality rates.Carotid artery stenosis is an important and independent risk factor for ischemic stroke.The three current approaches for treati...BACKGROUND Ischemic stroke is an entity with high incidence,morbidity,and mortality rates.Carotid artery stenosis is an important and independent risk factor for ischemic stroke.The three current approaches for treating carotid artery stenosis are drug treatment,carotid endarterectomy(CEA),carotid angioplasty and stenting(CAS).The approach is chosen based on the degree of stenosis.CEA or CAS could have been chosen for the current patient,who had severe carotid stenosis and an iodinated contrast allergy.After thoroughly communicating with the patient,the patient chose CAS for treatment.Therefore,we performed ultrasound-guided CAS to avoid the use of iodinated contrast.CASE SUMMARY The main symptoms of the patient were numbness and weakness of the left limb.Computed tomography angiography of the head and neck at another hospital indicated multiple sites of stenosis in the arteries of the head and neck.The patient requested CAS for treatment but was allergic to iodinated contrast media.Thus,routine digital subtraction angiography(DSA)with iodinated contrast could not be used for the procedure.The diagnosis of this patient was as follows:(1)Right parietal lobe cerebral infarction;(2)multiple sites of stenosis in the arteries of the head and neck(severe stenosis of the right internal carotid artery,severe stenosis of the right subclavian artery);(3)right subclavian steal syndrome;and(4)hypertension(stage 3,high risk).The interventions included routine treatment for cerebral infarction,oral administration of clopidogrel(75 mg qd)and aspirin(100 mg qd),ultrasound-guided CAS,and postoperative follow-up.Postoperative color Doppler ultrasound and cerebrovascular magnetic resonance angiography of the carotid artery showed good vascular recovery,and the postoperative follow-up indicated a good prognosis.CONCLUSION This case study suggests that ultrasound-guided endovascular treatment is a potential option for patients with contraindications to the iodinated contrast agents used in DSA-guided surgery,although excellent surgical operating skills are needed.展开更多
This study aims to determine the retention time of iodinated contrast agents (ICA) in the coronary artery. The mechanical aspect of ICA displacement was studied in order to better understand the effect of these produc...This study aims to determine the retention time of iodinated contrast agents (ICA) in the coronary artery. The mechanical aspect of ICA displacement was studied in order to better understand the effect of these products on the inner wall of the artery of patients with coronary artery stenosis, undergoing repeated imaging examinations with iodinated contrast agents. ICA flow, ICA and blood flow in the artery were modelled. The fluid was regarded to be viscous, incompressible and Newtonian. Blood flow was presumed to be unidirectional, laminar and unstationary. Iodine flow velocity and retention time were calculated using the Runge-Kutta 4th order method programmed in C++ and MatLab R2013a language. The results showed that for coronary artery CT-scans, ICA retention time is 1 minute 40 seconds and for coronary arteriography it is between 2.41 and 3.61 seconds. The values calculated were compared to theoretical values and to clinical observations. The results enabled us to validate our model.展开更多
The effect of low voltage and low concentration contrast agent on image quality of coronary CT angiography,radiation dose and iodine intake was evaluated.A total of 121 patients with body mass index(BMI)<26 kg/m2 a...The effect of low voltage and low concentration contrast agent on image quality of coronary CT angiography,radiation dose and iodine intake was evaluated.A total of 121 patients with body mass index(BMI)<26 kg/m2 and heart rate(HR)<70 beats/min were randomly divided into four groups:group A(n=31,80 kVp,270 mgl/mL);group B(n=33,100 kVp,270 mgl/mL);group C(h=30,100 kVp,320 mgl/mL);group D(w=27,100 kVp,400 mgl/mL).The automatic current modulation system and the iterative algorithm for reconstruction were adopted in each group.The CT values and SD values of the aortic root(AR),subcutaneous fat,left coronary artery opening(LCA),and right coronary artery opening(RCA)were measured in all groups,the signalto-noise ratio(SNR)and contrast noise ratio(CNR)were calculated,and effective radiation dose and iodine intake were recorded.The subjective assessment for image quality was performed by two physicians using a 4-point scale.The results were compared using the one-way ANOVA and rank sum tests.The image quality of the four groups met the clinical diagnostic requirements.The CT values of AR in groups A,B,C,and D were 537.6±71.4,447.2±81.9,445.2±64.9 and 518.5±94.9 Hu,respectively,with no significant difference between group A and group D,or between group B and group C,while CT values in groups B and C were significantly lower than those in groups A and D(P<0.05).In groups A,B,C,and D,the LCA SNR values were 22.7±9.1,23.3±9.1,23.3±7.7 and 26.6±8.9,and the RCA CNR values were 26.9±9.&28.5±11.4,27.7土&8 and 32」±10.6,respectively.The AR visual scores in groups A,B,C and D were 3.8±0.2,3.9±0.3,3.9±0.3 and 4.0±0.3,respectively.There were no significant differences in SNR,CNR and visual score among the four groups(P>0.05).The radiation doses in groups A,B,C and D were 2.6±1.4,3.6±1.&4.9±3.5 and 4.9±2.8 mSv,respectively.The radiation dose in group A was significantly less than that in the rest three groups(P<0.05).The iodine intakes in groups A,B,C and D were 14.9±1.5,15.0±1.5,17.7±2.0 and 18.1±2.5 g,respectively.There was no significant difference in the intake of iodine between groups C and D,or between groups A and B,while iodine intake in groups A and B were significantly reduced as compared with that in groups C and D(P<0.05).It was concluded that for patients with low BMI and controlled HR,compared to 100 kVp tube voltage combined with multiple concentration contrast agents,80 kVp combined with 270 mgl/mL contrast agent is enough to ensure the quality of the images,and can reduce the radiation dose significantly,while reducing the amount of iodine intake notably,thus reducing the incidence of adverse reaction.展开更多
Available online Iodinated X-ray contrast media (ICMs) are clinical drugs used to enhance the imaging effect.Triiodobenzene ring structures of ICMs lead to its extremely high chemical stability,biological inertness,wh...Available online Iodinated X-ray contrast media (ICMs) are clinical drugs used to enhance the imaging effect.Triiodobenzene ring structures of ICMs lead to its extremely high chemical stability,biological inertness,which makes it difficult to be completely removed by traditional water treatment processes.Hence,considerable concentration of ICMs can be frequently detected in aquatic environment.Relying on the strong oxidation capacity of HO·or SO_(4)^(·-),various advanced oxidation processes (AOPs) have demonstrated substantial removal efficiency for ICMs.It is evident that ICMs can be decomposed mainly through(1) deiodination,(2) dehydration,(3) decarboxylation,(4) H-abstraction,(5) hydroxyl addition,(6) hydroxyl substitution,(7) oxidation of alcohol groups,(8) cleavage of amide bond,and (9) amino oxidation.However,during the ICMs removal process,the C-I bonds of ICMs molecules are broken,giving rise to the formation of cytotoxic iodination disinfection by-products (I-DBPs) that are potentially more harmful to the ecosystem and human health than their parent compounds.To better understand the technology gaps,this review elaborates the major AOPs which are effective for ICMs removal and emphasizes on the main degradation routes of ICMs in different oxidation system.Some prevailing concerns and challenges are discussed for optimizing the ICMs treatment process.展开更多
Background:More than 75 million procedures with intravascular iodine-based contrast media(ICM)are performed worldwide every year,and some patients undergoing these procedures do not have normal thyroid function.The lo...Background:More than 75 million procedures with intravascular iodine-based contrast media(ICM)are performed worldwide every year,and some patients undergoing these procedures do not have normal thyroid function.The long-term effects of ICM in patients with mild thyroid dysfunction(TD)are unclear.Methods:This prospective cohort study was conducted in China.Patients with stable angina pectoris with total triiodothyronine(TT3)reduction,normal thyroid-stimulating hormone,and reverse triiodothyronine(rT3)were enrolled and divided into high-dose(≥100 mL ICM)and low-dose groups(<100 mL ICM).We dynamically investigated the trends in thyroid function,rT3,and thyroid antibodies one year after ICM exposure.Results:A total of 154 patients completed 6 months of follow-up and 149 completed 1 year of follow-up.Thyroglobulin antibody(TGAB)levels were elevated in 41(26.6%)patients before ICM exposure,11(7.1%)of whom also had elevated thyroid peroxidase antibody levels.Transient subclinical TD occurred 6 months after ICM exposure;75.5%(34/45)of post-operative TD occurred in the high-dose group.One patient developed severe hypothyroidism with myxedema,requiring drug intervention 1 year after ICM exposure.The level of rT3 showed no statistically significant changes during post-operative follow-up(P=0.848).The TGAB level decreased at 6th month(P<0.001),but increased at 1 year after ICM exposure(P=0.002).Conclusions:Patients with T3 reduction are at a risk of transient subclinical TD and hypothyroidism after a single large dose of ICM.Follow-up of this population at 9-12 months after ICM exposure is warranted.展开更多
基金supported by grant numbers NSF1124865 (SDR and SED)NSF1124844 (MJP)+1 种基金NIH T32 ES 007326 (CHJ)NIH T32 ES 007015 (CHJ)
文摘The presence of iodinated X-ray contrast media(ICM) in source waters is of high concern to public health because of their potential to generate highly toxic disinfection by-products(DBPs). The objective of this study was to determine the impact of ICM in source waters and the type of disinfectant on the overall toxicity of DBP mixtures and to determine which ICM and reaction conditions give rise to toxic by-products. Source waters collected from Akron,OH were treated with five different ICMs, including iopamidol, iopromide, iohexol,diatrizoate and iomeprol, with or without chlorine or chloramine disinfection. The reaction product mixtures were concentrated with XAD resins and the mammalian cell cytotoxicity and genotoxicity of the reaction mixture concentrates was measured. Water containing iopamidol generated an enhanced level of mammalian cell cytotoxicity and genotoxicity after disinfection. While chlorine disinfection with iopamidol resulted in the highest cytotoxicity overall, the relative iopamidol-mediated increase in toxicity was greater when chloramine was used as the disinfectant compared with chlorine. Four other ICMs(iopromide, iohexol, diatrizoate, and iomeprol) expressed some cytotoxicity over the control without any disinfection, and induced higher cytotoxicity when chlorinated. Only iohexol enhanced genotoxicity compared to the chlorinated source water.
基金Supported by the Foundation of the Longhua District Health System Project Cooperation 2022(basic and clinical research in ischemic stroke).
文摘BACKGROUND Ischemic stroke is an entity with high incidence,morbidity,and mortality rates.Carotid artery stenosis is an important and independent risk factor for ischemic stroke.The three current approaches for treating carotid artery stenosis are drug treatment,carotid endarterectomy(CEA),carotid angioplasty and stenting(CAS).The approach is chosen based on the degree of stenosis.CEA or CAS could have been chosen for the current patient,who had severe carotid stenosis and an iodinated contrast allergy.After thoroughly communicating with the patient,the patient chose CAS for treatment.Therefore,we performed ultrasound-guided CAS to avoid the use of iodinated contrast.CASE SUMMARY The main symptoms of the patient were numbness and weakness of the left limb.Computed tomography angiography of the head and neck at another hospital indicated multiple sites of stenosis in the arteries of the head and neck.The patient requested CAS for treatment but was allergic to iodinated contrast media.Thus,routine digital subtraction angiography(DSA)with iodinated contrast could not be used for the procedure.The diagnosis of this patient was as follows:(1)Right parietal lobe cerebral infarction;(2)multiple sites of stenosis in the arteries of the head and neck(severe stenosis of the right internal carotid artery,severe stenosis of the right subclavian artery);(3)right subclavian steal syndrome;and(4)hypertension(stage 3,high risk).The interventions included routine treatment for cerebral infarction,oral administration of clopidogrel(75 mg qd)and aspirin(100 mg qd),ultrasound-guided CAS,and postoperative follow-up.Postoperative color Doppler ultrasound and cerebrovascular magnetic resonance angiography of the carotid artery showed good vascular recovery,and the postoperative follow-up indicated a good prognosis.CONCLUSION This case study suggests that ultrasound-guided endovascular treatment is a potential option for patients with contraindications to the iodinated contrast agents used in DSA-guided surgery,although excellent surgical operating skills are needed.
文摘This study aims to determine the retention time of iodinated contrast agents (ICA) in the coronary artery. The mechanical aspect of ICA displacement was studied in order to better understand the effect of these products on the inner wall of the artery of patients with coronary artery stenosis, undergoing repeated imaging examinations with iodinated contrast agents. ICA flow, ICA and blood flow in the artery were modelled. The fluid was regarded to be viscous, incompressible and Newtonian. Blood flow was presumed to be unidirectional, laminar and unstationary. Iodine flow velocity and retention time were calculated using the Runge-Kutta 4th order method programmed in C++ and MatLab R2013a language. The results showed that for coronary artery CT-scans, ICA retention time is 1 minute 40 seconds and for coronary arteriography it is between 2.41 and 3.61 seconds. The values calculated were compared to theoretical values and to clinical observations. The results enabled us to validate our model.
文摘The effect of low voltage and low concentration contrast agent on image quality of coronary CT angiography,radiation dose and iodine intake was evaluated.A total of 121 patients with body mass index(BMI)<26 kg/m2 and heart rate(HR)<70 beats/min were randomly divided into four groups:group A(n=31,80 kVp,270 mgl/mL);group B(n=33,100 kVp,270 mgl/mL);group C(h=30,100 kVp,320 mgl/mL);group D(w=27,100 kVp,400 mgl/mL).The automatic current modulation system and the iterative algorithm for reconstruction were adopted in each group.The CT values and SD values of the aortic root(AR),subcutaneous fat,left coronary artery opening(LCA),and right coronary artery opening(RCA)were measured in all groups,the signalto-noise ratio(SNR)and contrast noise ratio(CNR)were calculated,and effective radiation dose and iodine intake were recorded.The subjective assessment for image quality was performed by two physicians using a 4-point scale.The results were compared using the one-way ANOVA and rank sum tests.The image quality of the four groups met the clinical diagnostic requirements.The CT values of AR in groups A,B,C,and D were 537.6±71.4,447.2±81.9,445.2±64.9 and 518.5±94.9 Hu,respectively,with no significant difference between group A and group D,or between group B and group C,while CT values in groups B and C were significantly lower than those in groups A and D(P<0.05).In groups A,B,C,and D,the LCA SNR values were 22.7±9.1,23.3±9.1,23.3±7.7 and 26.6±8.9,and the RCA CNR values were 26.9±9.&28.5±11.4,27.7土&8 and 32」±10.6,respectively.The AR visual scores in groups A,B,C and D were 3.8±0.2,3.9±0.3,3.9±0.3 and 4.0±0.3,respectively.There were no significant differences in SNR,CNR and visual score among the four groups(P>0.05).The radiation doses in groups A,B,C and D were 2.6±1.4,3.6±1.&4.9±3.5 and 4.9±2.8 mSv,respectively.The radiation dose in group A was significantly less than that in the rest three groups(P<0.05).The iodine intakes in groups A,B,C and D were 14.9±1.5,15.0±1.5,17.7±2.0 and 18.1±2.5 g,respectively.There was no significant difference in the intake of iodine between groups C and D,or between groups A and B,while iodine intake in groups A and B were significantly reduced as compared with that in groups C and D(P<0.05).It was concluded that for patients with low BMI and controlled HR,compared to 100 kVp tube voltage combined with multiple concentration contrast agents,80 kVp combined with 270 mgl/mL contrast agent is enough to ensure the quality of the images,and can reduce the radiation dose significantly,while reducing the amount of iodine intake notably,thus reducing the incidence of adverse reaction.
基金supported by the Science&Technology Innovation Action Plan of Shanghai under the Belt and Road Initiative (No.19230742800)。
文摘Available online Iodinated X-ray contrast media (ICMs) are clinical drugs used to enhance the imaging effect.Triiodobenzene ring structures of ICMs lead to its extremely high chemical stability,biological inertness,which makes it difficult to be completely removed by traditional water treatment processes.Hence,considerable concentration of ICMs can be frequently detected in aquatic environment.Relying on the strong oxidation capacity of HO·or SO_(4)^(·-),various advanced oxidation processes (AOPs) have demonstrated substantial removal efficiency for ICMs.It is evident that ICMs can be decomposed mainly through(1) deiodination,(2) dehydration,(3) decarboxylation,(4) H-abstraction,(5) hydroxyl addition,(6) hydroxyl substitution,(7) oxidation of alcohol groups,(8) cleavage of amide bond,and (9) amino oxidation.However,during the ICMs removal process,the C-I bonds of ICMs molecules are broken,giving rise to the formation of cytotoxic iodination disinfection by-products (I-DBPs) that are potentially more harmful to the ecosystem and human health than their parent compounds.To better understand the technology gaps,this review elaborates the major AOPs which are effective for ICMs removal and emphasizes on the main degradation routes of ICMs in different oxidation system.Some prevailing concerns and challenges are discussed for optimizing the ICMs treatment process.
基金supported by grants from the Hospital Level Project of Tianjin Chest Hospital in 2018(No.2018XKC08)funded by the Tianjin Key Medical Discipline(Specialty)Construction Project.
文摘Background:More than 75 million procedures with intravascular iodine-based contrast media(ICM)are performed worldwide every year,and some patients undergoing these procedures do not have normal thyroid function.The long-term effects of ICM in patients with mild thyroid dysfunction(TD)are unclear.Methods:This prospective cohort study was conducted in China.Patients with stable angina pectoris with total triiodothyronine(TT3)reduction,normal thyroid-stimulating hormone,and reverse triiodothyronine(rT3)were enrolled and divided into high-dose(≥100 mL ICM)and low-dose groups(<100 mL ICM).We dynamically investigated the trends in thyroid function,rT3,and thyroid antibodies one year after ICM exposure.Results:A total of 154 patients completed 6 months of follow-up and 149 completed 1 year of follow-up.Thyroglobulin antibody(TGAB)levels were elevated in 41(26.6%)patients before ICM exposure,11(7.1%)of whom also had elevated thyroid peroxidase antibody levels.Transient subclinical TD occurred 6 months after ICM exposure;75.5%(34/45)of post-operative TD occurred in the high-dose group.One patient developed severe hypothyroidism with myxedema,requiring drug intervention 1 year after ICM exposure.The level of rT3 showed no statistically significant changes during post-operative follow-up(P=0.848).The TGAB level decreased at 6th month(P<0.001),but increased at 1 year after ICM exposure(P=0.002).Conclusions:Patients with T3 reduction are at a risk of transient subclinical TD and hypothyroidism after a single large dose of ICM.Follow-up of this population at 9-12 months after ICM exposure is warranted.