The present paper is aimed to better illustrate the possible association between a particular extremely weak field, the air ions, and the human health response to this solicitation. Methods and instruments for this ki...The present paper is aimed to better illustrate the possible association between a particular extremely weak field, the air ions, and the human health response to this solicitation. Methods and instruments for this kind of analysis are here given in the form of a project: a "Ions meter", to reveal and characterize the properties of the air ions, and "APEC 300", an advanced electronic device, both instruments are with a HPR (high power of resolution). APEC 300 can give the response to the possible health effects by measurements of two electrocuteaneous parameter: the potential level and the impedance. The power of resolution of APEC 300 is much higher than that of other usual devices, for instance, the EAV ones (electroacupuncture), this instrument will be completely ready within few weeks.展开更多
针对双等离子体离子源受气压、磁场强度和放电电流影响,产生的O-离子束亮度不稳定的问题,设计并搭建了一套用于测试离子束亮度的离子光学系统,以SHRIMP II上的双等离子体离子源为对象,通过实验和仿真模拟分别研究了气压、磁场强度和放...针对双等离子体离子源受气压、磁场强度和放电电流影响,产生的O-离子束亮度不稳定的问题,设计并搭建了一套用于测试离子束亮度的离子光学系统,以SHRIMP II上的双等离子体离子源为对象,通过实验和仿真模拟分别研究了气压、磁场强度和放电电流对O-离子束亮度的影响规律。结果表明:该离子源能够稳定地工作在放电电流大于50 m A,气压为110~170 m Torr(1Torr=133.322 Pa)的条件下;当气压为140 m Torr、放电电流为200 m A、磁场强度为0.25 T时,获得的O-离子束亮度能够达到52.4 A/(cm2·sr)。合理控制离子源工作参数,可以增大O-离子束亮度,提高二次离子质谱的横向分辨率和灵敏度。展开更多
文摘The present paper is aimed to better illustrate the possible association between a particular extremely weak field, the air ions, and the human health response to this solicitation. Methods and instruments for this kind of analysis are here given in the form of a project: a "Ions meter", to reveal and characterize the properties of the air ions, and "APEC 300", an advanced electronic device, both instruments are with a HPR (high power of resolution). APEC 300 can give the response to the possible health effects by measurements of two electrocuteaneous parameter: the potential level and the impedance. The power of resolution of APEC 300 is much higher than that of other usual devices, for instance, the EAV ones (electroacupuncture), this instrument will be completely ready within few weeks.
文摘针对双等离子体离子源受气压、磁场强度和放电电流影响,产生的O-离子束亮度不稳定的问题,设计并搭建了一套用于测试离子束亮度的离子光学系统,以SHRIMP II上的双等离子体离子源为对象,通过实验和仿真模拟分别研究了气压、磁场强度和放电电流对O-离子束亮度的影响规律。结果表明:该离子源能够稳定地工作在放电电流大于50 m A,气压为110~170 m Torr(1Torr=133.322 Pa)的条件下;当气压为140 m Torr、放电电流为200 m A、磁场强度为0.25 T时,获得的O-离子束亮度能够达到52.4 A/(cm2·sr)。合理控制离子源工作参数,可以增大O-离子束亮度,提高二次离子质谱的横向分辨率和灵敏度。