Effect of Treatment Temperature on Iron Nitride Foils Irradiated with Nitrogen Plasma 被引量:1
1
作者 K.Niizuma and Y. Utsushiforwa (College of Industrial Technology, Nihon University, Narashino, Chiba 275-8575, Japan) 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2000年第2期143-144,共2页
We investigated the effect of treatment temperature on the magnetic property of iron nitride foils irradiated with nitrogen plasma. The iron nitride foils irradiated with nitrogen plasma were composed of ε-Fe2/3N, γ... We investigated the effect of treatment temperature on the magnetic property of iron nitride foils irradiated with nitrogen plasma. The iron nitride foils irradiated with nitrogen plasma were composed of ε-Fe2/3N, γ'-Fe4N and γ nitrogen austenite in α-Fe of the matrix. The saturation magnetization of the iron nitride foils decreased with increasing the surface temperature. The coercive force of the iron nitride foils increased with increasing the surface temperature. 展开更多
关键词 Effect of Treatment Temperature on iron nitride Foils Irradiated with Nitrogen Plasma
下载PDF
High Resolution Electron Microscopy Observations of Structural Changes in Iron Nitride Films Annealed in Vacuum
2
作者 Shengkai GONG Huibin XU (Dept. of Materials Science and Engineering, Beijing University of Aeronautics and Astronautics, Beijing 100083, China) 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 1997年第2期123-126,共4页
Iron-nitride films were prepared by reactive sputtering, and the effect of annealing treatment on the structures was investigated by means of in-situ electron microscopy and high resolution electron microscopy (HREM).... Iron-nitride films were prepared by reactive sputtering, and the effect of annealing treatment on the structures was investigated by means of in-situ electron microscopy and high resolution electron microscopy (HREM). As-deposited films were observed to be a mixed structure of a few ultrafine epsilon-Fe2-3N particles existing in the amorphous matrix. it was found that the structure-relaxation in the amorphous occurred at 473 K, and the ultrafine grains began to grow at the higher annealing temperatures. The transition of the amorphous to epsilon-Fe2-3N was almost completed at 673 K. It is considered that the formation of the ideal epsilon-Fe3N is originated from the ordering of the nitrogen atoms during the annealing in vacuum. On the other hand, gamma'-phase (Fe4N) was seen to precipitation of epsilon-phase at 723 K. Two possible modes are proposed in the precipitation of gamma'-phase, depending on the heating rate and crystallographic orientation relationships, i.e. [121](epsilon)//[001](gamma), (2(1) over bar0$)(epsilon)//(110)(gamma) and [100](epsilon)//[110](gamma), (001)(epsilon)//(111)(gamma). In addition, alpha-Fe particles were observed to form from the gamma'-phase at high temperatures. We assumed that these structural changes are due to the diffusion of nitrogen and iron atoms during the annealing, except for the case of the precipitation of the gamma'-phase as depicted above. The results obtained in this work are in a good agreement with the assumption. 展开更多
关键词 FIGURE High Resolution Electron Microscopy Observations of Structural Changes in iron nitride Films Annealed in Vacuum
下载PDF
The dispersion of iron nitride among porous carbon fibers to enhance redox conversion for high-performance zinc-iodine batteries 被引量:1
3
作者 Siyu Ding Qianwu Chen +2 位作者 Song Chen Yadong Tian Jintao Zhang 《Chinese Chemical Letters》 SCIE CAS CSCD 2023年第11期332-337,共6页
To address the insulating nature and the shuttle effect of iodide species that would deteriorate the battery performance,herein iron nitride is well-dispersed into porous carbon fibers with good flexibility via the fa... To address the insulating nature and the shuttle effect of iodide species that would deteriorate the battery performance,herein iron nitride is well-dispersed into porous carbon fibers with good flexibility via the facile electrospinning method and subsequent pyrolysis.The polyacrylonitrile precursor introduces the nitrogen doping under thermal treatment while the addition of iron acetylacetonate leads to the insitu formation of iron nitride among the carbon matrix.The crucial pyrolysis procedure is adjustable to determine the hierarchical porous structure and final composition of the novel carbon fiber composites.As the self-supporting electrode for loading iodine,the zinc-iodine battery exhibits a large specific capacity of 214 mAh/g and good cycling stability over 1600 h.In the combination of in-situ/ex-situ experimental measurements with the theoretical analysis,the in-depth understanding of intrinsic interaction between composited support and iodine species elucidates the essential mechanism to promote the redox kinetics of iodine via the anchoring effect and electrocatalytic conversion,thus improving cycling life and rate performance.Such fundamental principles on the basic redox conversion of iodine species would evoke the rational design of advanced iodine-based electrodes for improving battery performance. 展开更多
关键词 iron nitride Porous carbon fibers Redox conversion Rechargeable zinc-iodine batteries Enhanced cycling stability
原文传递
The effect of nitrogen on the compressibility and conductivity of iron at high pressure 被引量:1
4
作者 Yukai Zhuang Xiaowan Su +4 位作者 Nilesh P.Salke Zhongxun Cui Qingyang Hu Dongzhou Zhang Jin Liu 《Geoscience Frontiers》 SCIE CAS CSCD 2021年第2期983-989,共7页
Although nitrogen in the Earth’s interior has attracted significant attention recently,it remains the most enigmatic of the light elements in the Earth’s core.In this work,synchrotron X-ray diffraction(XRD)and elect... Although nitrogen in the Earth’s interior has attracted significant attention recently,it remains the most enigmatic of the light elements in the Earth’s core.In this work,synchrotron X-ray diffraction(XRD)and electrical conductivity experiments were conducted on iron nitrides(Fe_(2)N and Fe_(4)N)in diamond anvil cells(DACs)up to about 70 GPa at ambient temperature.These results show that iron nitrides are stable up to at least 70 GPa.From the equation of state(EOS)parameters,iron nitrides are more compressible than iron carbides.Moreover,using the van der Pauw method and Wiedemann-Franz law,the electrical and thermal conductivity of samples were determined to be much lower than that of iron carbides.The conductivities of Fe_(2)N and Fe_(4)N were similar at 20–70 GPa,suggesting no evident effects by varying the N stoichiometries in iron nitrides.Iron nitrides are less dense and conductive but more compressible than carbides at 0–70 GPa.This study indicates that less nitrogen than carbon can explain geophysical phenomena in the deep Earth,such as the density deficit. 展开更多
关键词 High pressure iron nitrides Synchrotron X-ray diffraction Electrical conductivity
下载PDF
Long-term safety and absorption assessment of a novel bioresorbable nitrided iron scaffold in porcine coronary artery 被引量:2
5
作者 Jian-Feng Zheng Zi-Wei Xi +17 位作者 Yang Li Jia-Nan Li Hong Qiu Xiao-Ying Hu Tong Luo Chao Wu Xin Wang Lai-Feng Song Li Li Hai-Ping Qi Gui Zhang Li Qin Wan-Qian Zhang Xiao-Li Shi Shu-Han Wang De-Yuan Zhang Bo Xu Run-Lin Gao 《Bioactive Materials》 SCIE 2022年第11期496-505,共10页
This study aimed to investigate the long-term biocompatibility, safety, and degradation of the ultrathin nitrided iron bioresorbable scaffold (BRS) in vivo, encompassing the whole process of bioresorption in porcine c... This study aimed to investigate the long-term biocompatibility, safety, and degradation of the ultrathin nitrided iron bioresorbable scaffold (BRS) in vivo, encompassing the whole process of bioresorption in porcine coronary arteries. Fifty-two nitrided iron scaffolds (strut thickness of 70 μm) and 28 Vision Co–Cr stents were randomly implanted into coronary arteries of healthy mini-swine. The efficacy and safety of the nitrided iron scaffold were comparable with those of the Vision stentwithin 52 weeks after implantation. In addition, the long-term biocompatibility, safety, and bioresorption of the nitrided iron scaffold were evaluated by coronary angiog-raphy, optical coherence tomography, micro-computed tomography, scanning electron microscopy, energy dispersive spectrometry and histopathological evaluations at 4, 12, 26, 52 weeks and even at 7 years after im-plantation. In particular, a large number of struts were almost completely absorbed in situ at 7 years follow-up, which were first illustrated in this study. The lymphatic drainage pathway might serve as the potential clearance way of iron and its corrosion products. 展开更多
关键词 Bioresorbable scaffold nitrided iron bioresorbable coronary scaffold Preclinical study Completely bioresorbable
原文传递