期刊文献+
共找到15,272篇文章
< 1 2 250 >
每页显示 20 50 100
Analytical computation of magnetic field in coil-dominated superconducting quadrupole magnets based on racetrack coils
1
作者 Chuang Shen Ying-Shun Zhu Fu-San Chen 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第4期119-135,共17页
Currently,three types of superconducting quadrupole magnets are used in particle accelerators:cos 2θ,CCT,and serpentine.However,all three coil configurations have complex spatial geometries,which make magnet manufact... Currently,three types of superconducting quadrupole magnets are used in particle accelerators:cos 2θ,CCT,and serpentine.However,all three coil configurations have complex spatial geometries,which make magnet manufacturing and strain-sensitive superconductor applications difficult.Compared with the three existing quadrupole coils,the racetrack quadrupole coil has a simple shape and manufacturing process,but there have been few theoretical studies.In this paper,the two-dimensional and three-dimensional analytical expressions for the magnetic field in coil-dominated racetrack superconducting quadrupole magnets are presented.The analytical expressions of the field harmonics and gradient are fully resolved and depend only on the geometric parameters of the coil and current density.Then,a genetic algorithm is applied to obtain a solution for the coil geometry parameters with field harmonics on the order of 10^(-4).Finally,considering the practical engineering needs of the accelerator interaction region,electromagnetic design examples of racetrack quadrupole magnets with high gradients,large apertures,and small apertures are described,and the application prospects of racetrack quadrupole coils are analyzed. 展开更多
关键词 Superconducting quadrupole magnet Racetrack coil Multipole field Genetic algorithm Magnetic design
下载PDF
Experimental and Numerical Investigation of the Performance of Turbulent Heat Transfer in Tubes with Different Cross-Sectioned Wire Coils
2
作者 Ali Shokor Golam 《Frontiers in Heat and Mass Transfer》 EI 2024年第2期633-653,共21页
The thermal-hydraulic performance of plain tubes with and without wire coils in turbulent regimes is investigated experimentally and numerically.The effects of wire coil distribution(circular cross section)within the ... The thermal-hydraulic performance of plain tubes with and without wire coils in turbulent regimes is investigated experimentally and numerically.The effects of wire coil distribution(circular cross section)within the tube were explored experimentally,and water was employed as the working fluid.The numerical simulation was carried out using software programmer ANSYS Fluent 2019 R3 using the finite-volume approach.In the turbulent regime,six cross-sectionedwire coilswere analyzed,including:circular,rectangular,hexagonal,square,star shape,and triangle.The utilization of a tube with a wire coil has been shown to increase heat transfer rate and pump consumption.The results indicate a high level of concurrence,as the deviations are all below 8%.Compared with plain tube,the wire coils,according to the arrangement(TWD),gave the best PEC.The heat transfer enhancement ability of different cross sections follows the following order:StCS>RCS>HCS>SqCS>CCS>TCS.Also,the sequence of pump consumption for each cross section is as follows:RCS>StCS>SqCS>HCS>CCS>TCS. 展开更多
关键词 Wire coil performance evaluation criterion friction factor circular tube cross section
下载PDF
Gradient coil design with enhanced shielding constraint for a cryogen-free superconducting MRI system 被引量:1
3
作者 Yaohui Wang Weimin Wang +3 位作者 Hui Liu Shunzhong Chen Feng Liu Qiuliang Wang 《Magnetic Resonance Letters》 2024年第1期1-9,共9页
The relatively fragile low-temperature stability of cryogen-free superconducting magnetic resonance imaging(MRI)magnets requires the careful management of exogenous heat sources.A strongly shielded gradient magnetic f... The relatively fragile low-temperature stability of cryogen-free superconducting magnetic resonance imaging(MRI)magnets requires the careful management of exogenous heat sources.A strongly shielded gradient magnetic field is important for the optimal operation of cryogen-free MRI systems.In this study,we present an enhanced shielding method incorporating a regionalized stray field constraining strategy.By optimizing the constraint parameters,we could develop engineering-feasible gradient coil schemes without increasing system complexity but with the stray field intensity reduced by half.In real measurement in an integrated MRI system,the developed gradient assembly demonstrated good performance and supported to output images of excellent quality.Our findings suggested that the proposed method could potentially form a useful design paradigm for cryogen-free MRI magnets. 展开更多
关键词 MRI Gradient coil Superconducting magnet Cryogen-free Magnetic shielding
下载PDF
Design of new resonant magnetic perturbation coils on the J-TEXT tokamak
4
作者 黄卓 周松 +11 位作者 樊金荣 李达 饶波 王能超 丁永华 毛飞越 黄名响 田微 陈忠勇 陈志鹏 梁云峰 the J-TEXT Team 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第11期142-149,共8页
The resonant magnetic perturbation(RMP)system is a powerful auxiliary system on tokamaks.On the J-TEXT tokamak,a set of new in-vessel coils is designed to enhance the amplitude of the RMP.The new coils are designed to... The resonant magnetic perturbation(RMP)system is a powerful auxiliary system on tokamaks.On the J-TEXT tokamak,a set of new in-vessel coils is designed to enhance the amplitude of the RMP.The new coils are designed to be two-turn saddle coils.These two-turn saddle coils have been optimized in terms of their structure,support,and protection components to overcome the limitations of the narrow in-vessel space,resulting in a compact coil module that can be accommodated in the vessel.To verify the feasibility of this design,an electromagnetic simulation is performed to investigate the electrical parameters and the generated field of the coils.A multi-field coupled simulation is performed to investigate the capacity of heat dissipation.As a result of these efforts,the new RMP coils have been successfully installed on the J-TEXT tokamak.It has significantly enhanced the RMP amplitude and been widely applied in experiments. 展开更多
关键词 fusion engineering TOKAMAK resonant magnetic perturbation coil multi-field coupled simulation(Some fioures may appeari in colour only in the online iournal)
下载PDF
Enhancing silicon spectral emission in LIBS using Tesla coil discharge
5
作者 Shuang CUI Yang LIU +1 位作者 Anmin CHEN Mingxing JIN 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第12期132-139,共8页
Laser-induced breakdown spectroscopy(LIBS)is a powerful technique for elemental analysis,offering rapid analysis,minimal sample preparation,wide elemental coverage,and portability.To enhance the detection sensitivity ... Laser-induced breakdown spectroscopy(LIBS)is a powerful technique for elemental analysis,offering rapid analysis,minimal sample preparation,wide elemental coverage,and portability.To enhance the detection sensitivity of LIBS,increasing the spectral emission intensity is crucial.This paper explores the use of Tesla coil(TC)discharge as an alternative to spark discharge in silicon LIBS.The study examines the influence of TC discharge on both time-integrated and timeresolved spectra,with and without TC discharge;the corresponding electron temperature and density are obtained.The results show that TC discharge significantly amplifies the spectral intensity,improving signal sensitivity in LIBS analysis.Specifically,in the laser energy range from 7.4 to 24.0 mJ,TC discharge increased the average spectral line intensities of Si(II)385.60 nm and Si(I)390.55 nm by factors of 8.4 and 5.1,respectively.Additionally,the average electron temperature and density were enhanced by approximately 3.2%and 4.2%,respectively,under TC discharge.The advantages of TC discharge include higher energy deposition,extended discharge duration,reduced electrode erosion,and enhanced safety.This research contributes to advancing LIBS technology and expanding its applications in various fields. 展开更多
关键词 LIBS Tesla coil spectral enhancement SILICON
下载PDF
Effect of coil and chamber structure on plasma radial uniformity in radio frequency inductively coupled plasma
6
作者 赵洋 周晓华 +2 位作者 高升荣 宋莎莎 赵玉真 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第7期58-66,共9页
Enhancing plasma uniformity can be achieved by modifying coil and chamber structures in radio frequency inductively coupled plasma(ICP)to meet the demand for large-area and uniformly distributed plasma in industrial m... Enhancing plasma uniformity can be achieved by modifying coil and chamber structures in radio frequency inductively coupled plasma(ICP)to meet the demand for large-area and uniformly distributed plasma in industrial manufacturing.This study utilized a two-dimensional self-consistent fluid model to investigate how different coil configurations and chamber aspect ratios affect the radial uniformity of plasma in radio frequency ICP.The findings indicate that optimizing the radial spacing of the coil enhances plasma uniformity but with a reduction in electron density.Furthermore,optimizing the coil within the ICP reactor,using the interior point method in the Interior Point Optimizer significantly enhances plasma uniformity,elevating it from 56%to 96%within the range of the model sizes.Additionally,when the chamber aspect ratio k changes from 2.8 to 4.7,the plasma distribution changes from a center-high to a saddleshaped distribution.Moreover,the plasma uniformity becomes worse.Finally,adjusting process parameters,such as increasing source power and gas pressure,can enhance plasma uniformity.These findings contribute to optimizing the etching process by improving plasma radial uniformity. 展开更多
关键词 inductively coupled plasma fluid simulation optimized coil chamber aspect ratio plasma uniformity
下载PDF
Fuzzy Proportional Integral Derivative control of a voice coil actuator system for adaptive deformable mirrors
7
作者 Ziqiang Cui Heng Zuo +4 位作者 Weikang Qiao Hao Li Fujia Du Yifan Wang Jinrui Guo 《Astronomical Techniques and Instruments》 CSCD 2024年第3期179-186,共8页
Research on adaptive deformable mirror technology for voice coil actuators(VCAs)is an important trend in the development of large ground-based telescopes.A voice coil adaptive deformable mirror contains a large number... Research on adaptive deformable mirror technology for voice coil actuators(VCAs)is an important trend in the development of large ground-based telescopes.A voice coil adaptive deformable mirror contains a large number of actuators,and there are problems with structural coupling and large temperature increases in their internal coils.Additionally,parameters of the traditional proportional integral derivative(PID)control cannot be adjusted in real-time to adapt to system changes.These problems can be addressed by introducing fuzzy control methods.A table lookup method is adopted to replace real-time calculations of the regular fuzzy controller during the control process,and a prototype platform has been established to verify the effectiveness and robustness of this process.Experimental tests compare the control performance of traditional and fuzzy proportional integral derivative(Fuzzy-PID)controllers,showing that,in system step response tests,the fuzzy control system reduces rise time by 20.25%,decreases overshoot by 78.24%,and shortens settling time by 67.59%.In disturbance rejection experiments,fuzzy control achieves a 46.09%reduction in the maximum deviation,indicating stronger robustness.The Fuzzy-PID controller,based on table lookup,outperforms the standard controller significantly,showing excellent potential for enhancing the dynamic performance and disturbance rejection capability of the voice coil motor actuator system. 展开更多
关键词 Adaptive optics Deformable mirror Voice coil actuator Fuzzy control
下载PDF
Mathematical Modelling and Design of Helical Coil Heat Exchanger for Production of Hot Air for Fluidized Bed Dryer
8
作者 Iniubong James Uwa Uwem Ekwere Inyang Innocent Oseribho Oboh 《Advances in Chemical Engineering and Science》 CAS 2024年第3期125-136,共12页
In global industrialization, efforts have been made to increase the rate of heat transfer in heat exchanger, minimizing the size of heat exchanger to reduce cost as well as increasing the effectiveness. Helical coil h... In global industrialization, efforts have been made to increase the rate of heat transfer in heat exchanger, minimizing the size of heat exchanger to reduce cost as well as increasing the effectiveness. Helical coil heat exchanger (HCHE) has been proven to be effective in improving heat transfer due to its large surface area. In this study, HCHE was designed to provide hot air needed for fluidized bed drying processes. The HCHE design model was fabricated and evaluated to study the efficiency of the hot air output for a laboratory fluidized bed dryer. The mathematical model for estimation of the final (output) temperature of air, Taf, passing through the HCHE was developed and validated experimentally. The drying of bitter kola particulates was carried out with a drying temperature of 50C 3C and a bed height-to-bed diameter ratio (H/D) of 1.5. The time taken to dry bitter kola particulates to 0.4% moisture content was 1 hour 45 minutes. Hence, HCHE is recommended for use in the production of hot for laboratory-scale fluidized bed dryers. 展开更多
关键词 Helical coil Heat Exchanger Fluidized Bed Dryer Heat Transfer Output Air Temperature
下载PDF
Numerical Studies on Thermal and Hydrodynamic Characteristics of LNG in Helically Coiled Tube-in-Tube Heat Exchangers
9
作者 Fayi Yan Xuejian Pei +1 位作者 He Lu Shuzhen Zong 《Frontiers in Heat and Mass Transfer》 EI 2024年第1期287-304,共18页
As compact and efficient heat exchange equipment,helically coiled tube-in-tube heat exchangers(HCTT heat exchangers)are widely used in many industrial processes.However,the thermal-hydraulic research of liquefied natu... As compact and efficient heat exchange equipment,helically coiled tube-in-tube heat exchangers(HCTT heat exchangers)are widely used in many industrial processes.However,the thermal-hydraulic research of liquefied natural gas(LNG)as the working fluid inHCTT heat exchangers is rarely reported.In this paper,the characteristics of HCTT heat exchangers,in which LNG flows in the inner tube and ethylene glycol-water solution flows in the outer tube,are studied by numerical simulations.The influences of heat transfer characteristics and pressure drops of the HCTT heat transfers are studied by changing the initial flow velocity,the helical middle diameter,and the helical pitch.The results indicate that different initial flow velocities in the inner tube and the outer tube of the HCTT heat exchanger have little influence on the secondary flow of the fluid in the helical tubes,and the overall flow characteristics tend to be stable.The smaller helical middle diameter of the HCTT heat exchanger leads to the shorter fluid flow length,the smaller resistance along the tubes and the increase of initial pressure under the condition of constant inlet velocity,which promotes the occurrence of secondary flow.The axial flow of fluid promotes the destruction of heat transfer boundary layer and gains strength of the turbulence and heat transfer efficiency.With the increase of the helical pitch of the HCTT heat exchanger,the turbulent intensity and the heat transfer efficiency are also increased.Moreover,the improvement of the flow state of the HCTT exchanger in a longer helical pitch also enhances the heat exchange efficiency. 展开更多
关键词 HCTT heat exchanger LNG helically coil heat transfer coefficient pressure drop
下载PDF
Numerical Simulation of Liquified Natural Gas Boiling Heat Transfer Characteristics in Helically Coiled Tube-in-Tube Heat Exchangers
10
作者 Fayi Yan He Lu Shijie Feng 《Frontiers in Heat and Mass Transfer》 EI 2024年第5期1493-1514,共22页
Helically coiled tube-in-tube(HCTT)heat exchangers are widely applied to the process technology because of their compactness and higher heat transfer efficiency.HCTT heat exchangers play an important role in liquified... Helically coiled tube-in-tube(HCTT)heat exchangers are widely applied to the process technology because of their compactness and higher heat transfer efficiency.HCTT heat exchangers play an important role in liquified natural gas(LNG)use and cold energy recovery.The heat transfer characteristics,pressure distribution,and degree of vaporization of LNG in HCTT heat exchangers are numerically investigated.By comparing the simulation results of the computational model with existing experimental results,the effectiveness of the computational model is verified.The numerical simulation results show the vapor volume fraction of the HCTT heat exchanger is related to the inlet Reynolds number,inner tube diameters,and helix diameter.The vapor volume fraction increases rapidly from the fourth to the seventh equal division points of the helix tube length.On condition that the inlet Reynolds number is greater than 33500,the pressure drop rate gradually increases.When the magnitude of the vapor volume fraction is below 0.2,the heat transfer coefficient increase rate is greater than that when the vapor volume fraction is above 0.2.The heat exchange efficiency of HCTT heat exchangers increases with the decrease of the ratio of helix diameter to inner tube diameter. 展开更多
关键词 Liquefied natural gas numerical simulation vapor-liquid two-phase flow heat transfer helically coiled tube-intube heat exchanger
下载PDF
CoilScan连续油管在线检测仪在页岩气开发中的应用 被引量:2
11
作者 熊江勇 王伟佳 +1 位作者 赵铭 方俊明 《长江大学学报(自科版)(中旬)》 CAS 2015年第5期94-96,9,共3页
CoilScan连续油管在线检测仪是目前最先进的便携式实时电磁检测设备,可有效地识别油管外径、椭圆度、壁厚、内外壁缺陷,是一种十分有效的连续油管检测系统。阐述了CoilScan连续油管在线检测仪的组成以及CoilScan连续油管在线检测原理,... CoilScan连续油管在线检测仪是目前最先进的便携式实时电磁检测设备,可有效地识别油管外径、椭圆度、壁厚、内外壁缺陷,是一种十分有效的连续油管检测系统。阐述了CoilScan连续油管在线检测仪的组成以及CoilScan连续油管在线检测原理,以涪陵页岩气田服务(通井作业)的一盘2in连续油管为例,探讨了CoilScan连续油管在线检测仪在页岩气开发中的应用,并制定了相应的连续油管在线检测标准:收到新的连续油管即进行检测;连续油管使用中应进行常规检测;井况比较苛刻、异常等非常规情形,建议作业完成后,再作业前进行一次检测;发现异常情况时需及时进行检测;其他情况如连续油管闲置待命超过6个月的,使用前需进行检测;连续油管使用满1年的,建议至少需要进行1次检测;连续油管必须建立独立档案进行统一管理。 展开更多
关键词 连续油管 在线检测仪 页岩气 开发 检测标准
下载PDF
PED+Coils与单纯PED治疗颅内复杂动脉瘤术后并发症的护理 被引量:2
12
作者 张素兰 范锋 +1 位作者 刘倩倩 马明逸 《中国实用神经疾病杂志》 2019年第1期68-71,共4页
目的探讨PED+Coils与单纯PED治疗颅内复杂动脉瘤并发症的护理。方法回顾性分析本中心连续使用PED治疗35例患者的临床资料,根据2组患者围术期并发症情况,有针对性地采取相应的护理方案,包括脑缺血的护理、脑出血的护理、神经功能障碍的... 目的探讨PED+Coils与单纯PED治疗颅内复杂动脉瘤并发症的护理。方法回顾性分析本中心连续使用PED治疗35例患者的临床资料,根据2组患者围术期并发症情况,有针对性地采取相应的护理方案,包括脑缺血的护理、脑出血的护理、神经功能障碍的护理、心理护理、专业的出院指导及延续性护理在随访中的应用等。结果 35例患者中,PED+Coils组15例,单纯PED组21例。手术成功率100%。共使用PED 40枚,支架开放不良5例,其中PED+Coils组4例,单纯PED组1例。缺血性并发症4例(11.4%),其中PED+Coils组1例(6.7%),单纯PED组3例(14.2%),均为轻微脑梗死。PED+Coils组出血性并发症1例,为导丝操作相关性,右侧肌力0级。经相关护理和康复指导,除1例永久致残性并发症患者外,其余患者无遗留神经功能缺失。1例永久致残性并发症患者给予专业的康复训练,出院时左侧上肢肌力3级,左下肢肌力4^-级。结论专业的护理是保证患者并发症预后的关键。 展开更多
关键词 Pipeline栓塞装置 弹簧圈 颅内复杂动脉瘤 介入 瘤体栓塞 载瘤血管重建 康复
下载PDF
Dynamic Performance of High Speed Solenoid Valve with Parallel Coils 被引量:15
13
作者 KONG Xiaowu LI Shizhen 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2014年第4期816-821,共6页
The methods of improving the dynamic performance of high speed on/off solenoid valve include increasing the magnetic force of armature and the slew rate of coil current, decreasing the mass and stroke of moving parts.... The methods of improving the dynamic performance of high speed on/off solenoid valve include increasing the magnetic force of armature and the slew rate of coil current, decreasing the mass and stroke of moving parts. The increase of magnetic force usually leads to the decrease of current slew rate, which could increase the delay time of the dynamic response of solenoid valve. Using a high voltage to drive coil can solve this contradiction, but a high driving voltage can also lead to more cost and a decrease of safety and reliability. In this paper, a new scheme of parallel coils is investigated, in which the single coil of solenoid is replaced by parallel coils with same ampere turns. Based on the mathematic model of high speed solenoid valve, the theoretical formula for the delay time of solenoid valve is deduced. Both the theoretical analysis and the dynamic simulation show that the effect of dividing a single coil into N parallel sub-coils is close to that of driving the single coil with N times of the original driving voltage as far as the delay time of solenoid valve is concerned. A specific test bench is designed to measure the dynamic performance of high speed on/off solenoid valve. The experimental results also prove that both the delay time and switching time of the solenoid valves can be decreased greatly by adopting the parallel coil scheme. This research presents a simple and practical method to improve the dynamic performance of high speed on/off solenoid valve. 展开更多
关键词 high speed solenoid valve parallel coils dynamic performance delay time
下载PDF
Designing shielded radio-frequency phased-array coils for magnetic resonance imaging 被引量:2
14
作者 徐文龙 张鞠成 +2 位作者 李霞 徐冰俏 陶贵生 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第1期46-53,共8页
In this paper, an approach to the design of shielded radio-frequency (RF) phased-array coils for magnetic resonance imaging (MRI) is proposed. The target field method is used to find current densities distributed ... In this paper, an approach to the design of shielded radio-frequency (RF) phased-array coils for magnetic resonance imaging (MRI) is proposed. The target field method is used to find current densities distributed on primary and shield coils. The stream function technique is used to discretize current densities and to obtain the winding patterns of the coils. The corresponding highly ill-conditioned integral equation is solved by the Tikhonov regularization with a penalty function related to the minimum curvature. To balance the simplicity and smoothness with the homogeneity of the magnetic field of the coll's winding pattern, the selection of a penalty factor is discussed in detail. 展开更多
关键词 active shield phased-array coil radio-frequency coil magnetic resonance imaging
下载PDF
A novel approach to designing cylindrical-surface shim coils for a superconducting magnet of magnetic resonance imaging 被引量:2
15
作者 刘文韬 俎栋林 唐昕 《Chinese Physics B》 SCIE EI CAS CSCD 2010年第1期563-574,共12页
For a superconducting magnet of magnetic resonance imaging (MRI), the novel approach presented in this paper allows the design of cylindrical gradient and shim coils of finite length. The method is based on identifi... For a superconducting magnet of magnetic resonance imaging (MRI), the novel approach presented in this paper allows the design of cylindrical gradient and shim coils of finite length. The method is based on identification of the weighting of harmonic components in the current distribution that will generate a magnetic field whose z-component follows a chosen spherical harmonic function. Mathematical expressions which relate the harmonic terms in the cylin- drical current distribution to spherical harmonic terms in the field expansion are established. Thus a simple matrix inversion approach can be used to design a shim coil of any order pure harmonic. The expressions providing a spherical harmonic decomposition of the field components produced by a particular cylindrical current distribution are novel. A stream function was applied to obtain the discrete wire distribution on the cylindrical-surface. This method does not require the setting of the target-field points. The discussion referring to matrix equations in terms of condition numbers proves that this novel approach has no ill-conditioned problems. The results also indicate that it can be used to design cylindrical-surface shim coils of finite length that will generate a field variation which follows a particular spherical harmonic over a reasonably large-sized volume. 展开更多
关键词 active shimming superconducting MRI magnet target-field approach harmonic coils
下载PDF
Analytical solutions of transient pulsed eddy current problem due to elliptical electromagnetic concentrative coils 被引量:2
16
作者 肖春燕 张军 《Chinese Physics B》 SCIE EI CAS CSCD 2010年第12期30-42,共13页
The electromagnetic concentrative coils are indispensable in the functional magnetic stimulation and have potential applications in nondestructive testing. In this paper, we propose a figure-8-shaped coil being compos... The electromagnetic concentrative coils are indispensable in the functional magnetic stimulation and have potential applications in nondestructive testing. In this paper, we propose a figure-8-shaped coil being composed of two arbitrary oblique elliptical coils, which can change the electromagnetic concentrative region and the magnitude of eddy current density by changing the elliptical shape and/or spread angle between two elliptical coils. Pulsed current is usually the excitation source in the functional magnetic stimulation, so in this paper we derive the analytical solutions of transient pulsed eddy current field in the time domain due to the elliptical concentrative coil placed in an arbitrary position over a half-infinite plane conductor by making use of the scale-transformation, the Laplace transform and the Fourier transform are used in our derivation. Calculation results of field distributions produced by the figure-8-shaped elliptical coil show some behaviours as follows: 1) the eddy currents are focused on the conductor under the geometric symmetric centre of figure-8-shaped coil; 2) the greater the scale factor of ellipse is, the higher the eddy current density is and the wider the concentrative area of eddy current along y axis is; 3) the maximum magnitude of eddy current density increases with the increase of spread angle. When spread angle is 180°, there are two additional reverse concentrative areas on both sides of x axis. 展开更多
关键词 transient pulsed eddy current analytical solution elliptical electromagnetic concentra-tive coil functional magnetic stimulation
下载PDF
Rapid Thermal-Hydraulic Analysis and Design Optimization of ITER Upper ELM Coils 被引量:1
17
作者 张善文 宋云涛 +8 位作者 王忠伟 卢速 戢翔 杜双松 刘旭峰 冯昌乐 杨洪 王松可 罗志仁 《Plasma Science and Technology》 SCIE EI CAS CSCD 2014年第10期978-983,共6页
ITER edge localized mode (ELM) coils are important components of the in-vessel coils (IVCs) and they are designed for mitigating or suppressing ELMs. The coils located on the vacuum vessel (VV) and behind the bl... ITER edge localized mode (ELM) coils are important components of the in-vessel coils (IVCs) and they are designed for mitigating or suppressing ELMs. The coils located on the vacuum vessel (VV) and behind the blanket are subjected to high temperature due to the nuclear heat from the plasma, the Ohmic heat induced by the working current and the thermal radiation from the environment. The water serves as coolant to remove the heat deposited into the coils. Based on the results of nuclear analysis, the thermal-hydraulic analysis is performed for the preliminary design of upper ELM coils using a rapid evaluation method based on 1D treatment. The thermal-hydraulic design and operating parameters including the water flow velocity are optimized. It is found that the rapid evaluation method based on 1D treatment is feasible and reliable. According to the rapid analysis method, the thermal hydraulic parameters of two water flow schemes are computed and proved similar to each other, providing an effective basis for the coil design. Finally, considering jointly the pressure drop requirement and the cooling capacity, the flow velocity is optimized to 5 m/s. 展开更多
关键词 ITER upper ELM coils thermal-hydraulic analysis
下载PDF
An efficient calibration method for SQUID measurement system using three orthogonal Helmholtz coils 被引量:1
18
作者 李华 张树林 +2 位作者 张朝祥 孔祥燕 谢晓明 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第6期585-588,共4页
For a practical superconducting quantum interference device(SQUID) based measurement system,the Tesla/volt coefficient must be accurately calibrated.In this paper,we propose a highly efficient method of calibrating ... For a practical superconducting quantum interference device(SQUID) based measurement system,the Tesla/volt coefficient must be accurately calibrated.In this paper,we propose a highly efficient method of calibrating a SQUID magnetometer system using three orthogonal Helmholtz coils.The Tesla/volt coefficient is regarded as the magnitude of a vector pointing to the normal direction of the pickup coil.By applying magnetic fields through a three-dimensional Helmholtz coil,the Tesla/volt coefficient can be directly calculated from magnetometer responses to the three orthogonally applied magnetic fields.Calibration with alternating current(AC) field is normally used for better signal-to-noise ratio in noisy urban environments and the results are compared with the direct current(DC) calibration to avoid possible effects due to eddy current.In our experiment,a calibration relative error of about 6.89 × 10-4is obtained,and the error is mainly caused by the non-orthogonality of three axes of the Helmholtz coils.The method does not need precise alignment of the magnetometer inside the Helmholtz coil.It can be used for the multichannel magnetometer system calibration effectively and accurately. 展开更多
关键词 SQUID MAGNETOMETER Tesla/volt coefficient calibration three-dimensional Helmholtz coil
下载PDF
In vitro effect of biologically active coating on endothelialisation of Nitinol coils designed for the closure of intracardiac shunt 被引量:1
19
作者 XiangqingKong 《Journal of Nanjing Medical University》 2005年第1期15-20,共6页
Objective:To evaluate in vitro the effect of biologically active coating on endothelialisation of Nitinol coils designed for the closure of intracardiac shunt. Methods:Covalently binding procedure was performed with c... Objective:To evaluate in vitro the effect of biologically active coating on endothelialisation of Nitinol coils designed for the closure of intracardiac shunt. Methods:Covalently binding procedure was performed with chemical vapor deposition (CVD). Heparin(200 IU/ml),r-hirudin(21 nmol/ml),or fibronectin(15 μg/ml),respectively, were bound to the basic coating(poly(amino-p-xylylene-co-p-xylylen)). In vitro tests were performed on five different coating groups(n=2 each):uncoated Nitinol, basic coating,heparin-,r-hirudin-,and fibronectin-coating. Human umbilical vein endothelial cells(HUVECs) were cultured in the presence of tested coils for 48 and 72 h. Adhesion of HUVECs were evaluated with light microscopy,and with confocal laser scanning microscopy after double-staining of vinculin,phalloidin, Ki67 and fibronectin. Results: After 48 and 72 h of incubation,except HUVECs around the basic coating showing abnormal morphology, HUVECs were able to grow next to all kinds of coils. By CLSM adhering cells were typically confined to maximal three secondary coil windings. HUVECs adhered best to the fibronectin coated coils,followed by the uncoated Nitinol. HUVECs barely adhered to the basic coating. The adhesion to heparin coating or r-hirudin coating was observed with various cell densities. Heparin coating seemed to support cell adhesion better than r-hirudin coating did. The HUVECs assembled fibronectin matrix on the fibronectin coating and uncoated Nitinol coil. Vinculin was expressed on both fibronectin coating and uncoated Nitinol as well, mostly diffused,but occasionally also in focal contacts. Ki67 expression was mainly noticed on the uncoated Nitinol coil and fibronectin coated coil,only occasionally on other materials. The densities and morphology of HUVECs, adhered to the correspohding well surfaces,were similar for all wells. The only exception was the well with the basic coating coil after three days of incubation. In this case, the cell density was diminished,and the cells became more elongated. The cells grown on the well surfaces exhibited a more profound matrix assembly and more pronounced focal adhesions than the cells adhered to the coil surfaces did. Conclusion:Except for basic coating,biologically active substance coated or uncoated coils show no acute cytotoxicity on HUVECs. Due to better cell proliferation,cell matrix assembling,and focal adhesion,only fibronectin coating improves the endothelialisation of Nitinol coils. 展开更多
关键词 covalently binding coil ENDOTHELIALISATION HEPARIN r-hirudin FIBRONECTIN
下载PDF
Deformation of Linked Polymer Coils 被引量:1
20
作者 董朝霞 李明远 +1 位作者 吴肇亮 林梅钦 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2003年第6期686-690,共5页
Linked polymer solution (LPS) is defined as the solution of linked polymer coils (LPCs) dispersed in water, composed of low concentration partially hydrolyzed polyacrylamide (HPAM) and aluminum citrate (crosslinker). ... Linked polymer solution (LPS) is defined as the solution of linked polymer coils (LPCs) dispersed in water, composed of low concentration partially hydrolyzed polyacrylamide (HPAM) and aluminum citrate (crosslinker). In the work, the conformational changes of LPCs under different conditions were investigated by the methods of membrane filtering under low pressure, dynamic light scattering and core flooding experiments. The results showed that in some conditions the LPCs could be compressed mechanically to 1/158.5 of their original volume because of relatively lower HPAM cross-linking. The hydration property of LPCs was similar to that of normal polymer coils. The deformation of LPCs was more restricted than that of ordinary polymer coils under the flow shear stress or the shift of hydration equilibrium caused in the variation of the electrolyte concentration which is responsible for the effective plugging in the throats of porous media when LPCs are used for deep diverting. 展开更多
关键词 partially hydrolyzed polyacrylamide linked polymer solution coil DEFORMATION
下载PDF
上一页 1 2 250 下一页 到第