A new staggered isolated system developed from the mid-story isolated system is the new staggered story isolated system. There are not many studies on this structure currently. In this study, an 18-story new staggered...A new staggered isolated system developed from the mid-story isolated system is the new staggered story isolated system. There are not many studies on this structure currently. In this study, an 18-story new staggered story isolated system model is established using SAP2000. The dynamic nonlinear dynamic alternate method is used to analyze the structure against progressive collapse. Results show that the structure has good resistance to progressive collapse, and there is no progressive collapse under each working condition. The progressive collapse does not occur for the case of removing only one vertical structural member of the new staggered of isolated system. The side column has big influence on this isolated structures’ progressive collapse;the removal of vertical structural member of the isolation layer has less impact on the structure than the removal of the bottom vertical structural member. After the removing of the member, the internal force of the structure will be redistributed, and the axial force of the adjacent columns will change obviously, showing a trend of “near large and far small”.展开更多
Increasing buildings’ resistance to earthquake forces is not always a desirable solution especially for the building contents that are irreplaceable or simply more valuable than the actual primary structure (e.g. mus...Increasing buildings’ resistance to earthquake forces is not always a desirable solution especially for the building contents that are irreplaceable or simply more valuable than the actual primary structure (e.g. museums, data storage Centre’s, etc.). Base isolation and seismic dampers can be employed to minimize inter-story drifts and floor accelerations via specially designed isolation and dampers system at the structural base, or at higher levels of the superstructure. In this research, we’ll examine the response of buildings isolated using isolation system hybrid consisting of Lead-Rubber Bearings (LRB), Flat Sliding Bearings (FSB), with the addition of Rotation Fiction Damper (FD) at the base, then compare the results with buildings that have traditional foundation, in terms of the (period, displacement and distribution shear force and height of the building). It conducts TIME HISTORY seismic analysis for some varying height buildings (eight, twelve, sixteen, and twenty stories), with help of SAP2000 using an earthquake acceleration-time history for (El- Centro). The results show that the use of insulation system Hybrid has had a significant impact on improving the performance of origin in terms of reducing displacements and base shear with in-creasing height of the building, but has had a negative impact on the drift, which leads to an in-crease in drift with the increased flexibility of the building.展开更多
BACKGROUND Isolated left ventricular apical hypoplasia(ILVAH),also known as truncated left ventricle(LV),is a very unusual cardiomyopathy.It is characterised by a truncated,spherical,and non-apex forming LV.The true a...BACKGROUND Isolated left ventricular apical hypoplasia(ILVAH),also known as truncated left ventricle(LV),is a very unusual cardiomyopathy.It is characterised by a truncated,spherical,and non-apex forming LV.The true apex is occupied by the right ventricle.Due to the rarity of the disease,just a few case reports and limited case series have been published in the field.AIM To analysing the so far 37 reported ILVAH cases worldwide.METHODS The electronic databases PubMed and Scopus were investigated from their establishment up to December 13,2022.RESULTS The majority of cases reported occurred in males(52.7%).Mean age at diagnosis was 26.1±19.6 years.More than a third of the patients were asymptomatic(35.1%).The most usual clinical presentation was breathlessness(40.5%).The most commonly detected electrocardiogram changes were T wave abnormalities(29.7%)and right axis deviation with poor R wave progression(24.3%).Atrial fibrillation/flutter was detected in 24.3%.Echocardiography was performed in 97.3%of cases and cardiac MRI in 91.9%of cases.Ejection fraction was reduced in more than a half of patients(56.7%).An associated congenital heart disease was found in 16.2%.Heart failure therapy was administered in 35.1%of patients.The outcome was favorable in the vast majority of patients,with just one death.CONCLUSION ILVAH is a multifaceted entity with a so far unpredictable course,ranging from benign until the elderly to sudden death during adolescence.展开更多
The Tibetan Plateau(TP)is a prevalent region for convection systems due to its unique thermodynamic forcing.This study investigated isolated deep convections(IDCs),which have a smaller spatial and temporal size than m...The Tibetan Plateau(TP)is a prevalent region for convection systems due to its unique thermodynamic forcing.This study investigated isolated deep convections(IDCs),which have a smaller spatial and temporal size than mesoscale convective systems(MCSs),over the TP in the rainy season(June-September)during 2001–2020.The authors used satellite precipitation and brightness temperature observations from the Global Precipitation Measurement mission.Results show that IDCs mainly concentrate over the southern TP.The IDC number per rainy season decreases from around 140 over the southern TP to around 10 over the northern TP,with an average 54.2.The initiation time of IDCs exhibits an obvious diurnal cycle,with the peak at 1400–1500 LST and the valley at 0900–1000 LST.Most IDCs last less than five hours and more than half appear for only one hour.IDCs generally have a cold cloud area of 7422.9 km^(2),containing a precipitation area of approximately 65%.The larger the IDC,the larger the fraction of intense precipitation it contains.IDCs contribute approximately 20%–30%to total precipitation and approximately 30%–40%to extreme precipitation over the TP,with a larger percentage in July and August than in June and September.In terms of spatial distribution,IDCs contribute more to both total precipitation and extreme precipitation over the TP compared to the surrounding plain regions.IDCs over the TP account for a larger fraction than MCSs,indicating the important role of IDCs over the region.展开更多
At present,there is not much research on mid-story isolated structures in mountainous areas.In this study,a model of a mid-story isolated structure considering soil-structure interaction(SSI)in mountainous areas is es...At present,there is not much research on mid-story isolated structures in mountainous areas.In this study,a model of a mid-story isolated structure considering soil-structure interaction(SSI)in mountainous areas is established along with a model that does not consider SSI.Eight long-period earthquake waves and two ordinary earthquake waves are selected as inputs for the dynamic time history analysis of the structure.The results show that the seismic response of a mid-story isolated structure considering SSI in mountainous areas can be amplified when compared with a structure that does not consider SSI.The structure response under long-period earthquakes is larger than that of ordinary earthquakes.The structure response under far-field harmonic-like earthquakes is larger than that of near-fault pulse-type earthquakes.The structure response under near-fault pulse-type earthquakes is larger than that of far-field non-harmonic earthquakes.When subjected to long-period earthquakes,the displacement of the isolated bearings exceeded the limit value,which led to instability and overturning of the structure.The structure with dampers in the isolated story could adequately control the nonlinear response of the structure,effectively reduce the displacement of the isolated bearings,and provide a convenient,efficient and economic method not only for new construction but also to retrofit existing structures.展开更多
In response to the problems of unclear distribution of deep-water pre-salt carbonate reservoirs and formation conditions of large oil fields in the Santos passive continental margin basin,based on comprehensive utiliz...In response to the problems of unclear distribution of deep-water pre-salt carbonate reservoirs and formation conditions of large oil fields in the Santos passive continental margin basin,based on comprehensive utilization of geological,seismic,and core data,and reconstruction of Early Cretaceous prototype basin and lithofacies paleogeography,it is proposed for the first time that the construction of pre-salt carbonate build-ups was controlled by two types of isolated platforms:inter-depression fault-uplift and intra-depression fault-high.The inter-depression fault-uplift isolated platforms are distributed on the present-day pre-salt uplifted zones between depressions,and are built on half-and fault-horst blocks that were inherited and developed in the early intra-continental and inter-continental rift stages.The late intra-continental rift coquinas of the ITP Formation and the early inter-continental rift microbial limestones of the BVE Formation are continuously constructed;intra-depression fault-high isolated platforms are distributed in the current pre-salt depression zones,built on the uplifted zones formed by volcanic rock build-ups in the early prototype stage of intra-continental rifts,and only the BVE microbial limestones are developed.Both types of limestones formed into mound-shoal bodies,that have the characteristics of large reservoir thickness and good physical properties.Based on the dissection of large pre-salt oil fields discovered in the Santos Basin,it has been found that both types of platforms could form large-scale combined structural-stratigraphic traps,surrounded by high-quality lacustrine and lagoon source rocks at the periphery,and efficiently sealed by thick high-quality evaporite rocks above,forming the optimal combination of source,reservoir and cap in the form of“lower generation,middle storage,and upper cap”,with a high degree of oil and gas enrichment.It has been found that the large oil fields are all bottom water massive oil fields with a unified pressure system,and they are all filled to the spill-point.The future exploration is recommended to focus on the inter-depression fault-uplift isolated platforms in the western uplift zone and the southern section of eastern uplift zones,as well as intra-depression fault-high isolated platforms in the central depression zone.The result not only provides an important basis for the advanced selection of potential play fairways,bidding of new blocks,and deployment of awarded exploration blocks in the Santos Basin,but also provides a reference for the global selection of deep-water exploration blocks in passive continental margin basins.展开更多
High-efficient isolated DC/DC converters with a high-efficiency synchronous reluctance generator(SRG)are the ultimate solutions in DC microgrid systems.The design and modeling of isolated DC/DC converters with the per...High-efficient isolated DC/DC converters with a high-efficiency synchronous reluctance generator(SRG)are the ultimate solutions in DC microgrid systems.The design and modeling of isolated DC/DC converters with the performance of SRG are carried out.On the generator side,reactive and active powers are used as pulse width modulation(PWM)control variables.Further,the flux estimator is used.Three-phase PWM rectifier is used by applying space vector modulation(SVM)with a constant switching frequency for direct power control.Further,the paper also includes the experimental validation of the results.The paper also proposes that highly efficient power converters and synchronous reluctance generators are required to achieve high performance for hybrid renewable energy systems applications.展开更多
BACKGROUND Solitary fibrous tumors(SFT)are rare spindle cell tumors that are usually benign.A total of 10 cases of SFTs in the upper esophagus have ever been reported.Here,we report the anesthetic management of a pati...BACKGROUND Solitary fibrous tumors(SFT)are rare spindle cell tumors that are usually benign.A total of 10 cases of SFTs in the upper esophagus have ever been reported.Here,we report the anesthetic management of a patient with a large isolated fibrous tumor of the upper esophagus compressing the tracheal membrane.We also provide a literature review of the current research.CASE SUMMARY We report the case of a 49 year old male with“cough aggravation and wheezing after exercise”,who underwent esophagectomy for a large isolated fibrous tumor compressing the tracheal membrane in the upper esophagus.We advise the use of a single-lumen tube with a blocker in patients with difficult airways to reduce the incidence of airway injury and fibrinoscopy at all stages of the perioperative period to guide airway management.This case study is the first report of the anesthetic management of a large,isolated fibrous tumor compressing the tracheal membrane in the upper esophagus.CONCLUSION This rare case emphasizes the importance of perioperative management of anesthesia in patients with large isolated fibrous tumors of the upper esophagus that compress the tracheal membrane.The use of blocker reduce the incidence of airway injury and fibrinoscopy at the perioperative period to guide airway mana-gement.展开更多
BACKGROUND The tear of the gluteus medius and minimus tendons can cause chronic buttock pain,especially in middle-aged individuals;these tears occur mostly in association with degenerative changes in the muscles and t...BACKGROUND The tear of the gluteus medius and minimus tendons can cause chronic buttock pain,especially in middle-aged individuals;these tears occur mostly in association with degenerative changes in the muscles and tendons.Chronic injuries are more common than acute injuries,and concurrent injuries to the gluteus medius and minimus tendons without chronic pain are rare,especially isolated injuries to both sides of the gluteus minimus;such a case has not yet been reported.CASE SUMMARY The authors present a case of bilateral acute traumatic injuries to the gluteus minimus during buttock strengthening exercises in a 75-year-old male patient.The patient completely returned to his pre-injury lifestyle after 8 weeks of injury,with no limitations,but the diagnosis was initially delayed due to misdiagnosis as lumbar radiculopathy,resulting in unnecessary socio-economic burden on the patient.CONCLUSION When treating patients who complain of hip pain,it is important to consider various causes to make a correct diagnosis.展开更多
The levered-dual response(LEDAR)Coulomb-damped system attains near resonant vibration isolation by differential preloads/offsets in linear springs.It takes the advantages of both the preloads/offsets in linear springs...The levered-dual response(LEDAR)Coulomb-damped system attains near resonant vibration isolation by differential preloads/offsets in linear springs.It takes the advantages of both the preloads/offsets in linear springs and the guiderail friction for realizing different levels of vibration isolation.The isolation capacities are investigated on the strategies with both the horizontal and vertical guiderails,with the horizontal rail only,and without guiderails.The compressive preloads generally result in the consumption of most of the initial excitation energy so as to overcome the potential threshold.The isolation onsets at the frequency ratio of 1∓0.095 on the left-hand side(LHS)and the right-hand side(RHS)of the lever are relative to the load plate connector.The observed near resonant isolation thus makes the LEDAR system a candidate for the isolation of the mechanical systems about resonance while opening a path for simultaneous harvesterisolation functions and passive functions at extreme frequencies.展开更多
BACKGROUND Interventional endoscopic ultrasound is clinically used for the treatment of isolated gastric varices(IGVs)owing to its precise visualization.CASE SUMMARY A 39-year-old man was diagnosed with a large IGV du...BACKGROUND Interventional endoscopic ultrasound is clinically used for the treatment of isolated gastric varices(IGVs)owing to its precise visualization.CASE SUMMARY A 39-year-old man was diagnosed with a large IGV during a routine physical examination.Endoscopic ultrasonography showed gastric varices entwined with an artery,which greatly increased the difficulty of treatment.We successfully treated the patient with endoscopic ultrasonography-guided coil embolization combined with cyanoacrylate injection.CONCLUSION Endoscopic ultrasonography-guided coil embolization combined with cyanoacrylate injection was safe and effective for the treatment of an IGV entwined with an artery.展开更多
Fault isolation in dynamical systems is a challenging task due to modeling uncertainty and measurement noise,interactive effects of multiple faults and fault propagation.This paper proposes a unified approach for isol...Fault isolation in dynamical systems is a challenging task due to modeling uncertainty and measurement noise,interactive effects of multiple faults and fault propagation.This paper proposes a unified approach for isolation of multiple actuator or sensor faults in a class of nonlinear uncertain dynamical systems.Actuator and sensor fault isolation are accomplished in two independent modules,that monitor the system and are able to isolate the potential faulty actuator(s)or sensor(s).For the sensor fault isolation(SFI)case,a module is designed which monitors the system and utilizes an adaptive isolation threshold on the output residuals computed via a nonlinear estimation scheme that allows the isolation of single/multiple faulty sensor(s).For the actuator fault isolation(AFI)case,a second module is designed,which utilizes a learning-based scheme for adaptive approximation of faulty actuator(s)and,based on a reasoning decision logic and suitably designed AFI thresholds,the faulty actuator(s)set can be determined.The effectiveness of the proposed fault isolation approach developed in this paper is demonstrated through a simulation example.展开更多
BACKGROUND Adipose-derived stem cells(ADSCs)and the stromal vascular fraction(SVF)have garnered substantial interest in regenerative medicine due to their potential to treat a wide range of conditions.Traditional enzy...BACKGROUND Adipose-derived stem cells(ADSCs)and the stromal vascular fraction(SVF)have garnered substantial interest in regenerative medicine due to their potential to treat a wide range of conditions.Traditional enzymatic methods for isolating these cells face challenges such as high costs,lengthy processing time,and regulatory complexities.AIM This systematic review aimed to assess the efficacy and practicality of nonenzymatic,mechanical methods for isolating SVF and ADSCs,comparing these to conventional enzymatic approaches.METHODS Following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines,a comprehensive literature search was conducted across multiple databases.Studies were selected based on inclusion criteria focused on non-enzymatic isolation methods for SVF and ADSCs from adipose tissue.The risk of bias was assessed,and a qualitative synthesis of findings was performed due to the methodological heterogeneity of the included studies.RESULTS Nineteen studies met the inclusion criteria,highlighting various mechanical techniques such as centrifugation,vortexing,and ultrasonic cavitation.The review identified significant variability in cell yield and viability,and the integrity of isolated cells across different non-enzymatic methods compared to enzymatic procedures.Despite some advantages of mechanical methods,including reduced processing time and avoidance of enzymatic reagents,the evidence suggests a need for optimization to match the cell quality and therapeutic efficacy achievable with enzymatic isolation.CONCLUSION Non-enzymatic,mechanical methods offer a promising alternative to enzymatic isolation of SVF and ADSCs,potentially simplifying the isolation process and reducing regulatory hurdles.However,further research is necessary to standardize these techniques and ensure consistent,high-quality cell yields for clinical applications.The development of efficient,safe,and reproducible non-enzymatic isolation methods could significantly advance the field of regenerative medicine.展开更多
The aspect ratio of the structure has a significant impact on the overall stability of the ultra high-rise building. A large aspect ratio of the structure increases the risk of overturning and reduces the lateral stif...The aspect ratio of the structure has a significant impact on the overall stability of the ultra high-rise building. A large aspect ratio of the structure increases the risk of overturning and reduces the lateral stiffness of the structure, leading to significant tensile and compressive stresses in the isolated bearings. To study the effect of aspect ratio on the seismic response and overturning resistance of a new staggered story isolated structure, three models with different aspect ratios were established. Nonlinear time-history analysis of the three models was conducted using ETABS finite element software. The results indicate that the overturning moment and overturning resistance moment of the superstructure in the new staggered story isolated structure increase with an increasing aspect ratio. However, the increase in the overturning moment of the superstructure is much greater than the increase in the overturning resistance moment, resulting in a decrease in the overturning resistance ratio of the superstructure with an increasing aspect ratio. The overturning moment and overturning resistance moment of the substructure in the new staggered story isolated structure decrease with an increasing aspect ratio. However, the decrease in the overturning moment of the substructure is greater than the decrease in the overturning resistance moment, leading to an increase in the overturning resistance ratio of the substructure with an increasing aspect ratio. The decrease in the overturning resistance ratio of the superstructure in the new staggered story isolated structure is much greater than the increase in the overturning resistance ratio of the substructure. Therefore, as the aspect ratio of the overall structure increases, the overturning resistance ratio of the superstructure and the entire structure decreases.展开更多
To analyze the seismic response of steel structure isolation systems under long-period seismic motion,a 9-story steel frame building was selected as the subject.Five steel structure finite element models were establis...To analyze the seismic response of steel structure isolation systems under long-period seismic motion,a 9-story steel frame building was selected as the subject.Five steel structure finite element models were established using SAP2000.Response spectrum analysis was conducted on the seismic motion to determine if it adhered to the characteristics of long-period seismic motion.Modal analysis of each structural model revealed that the isolation structure significantly prolonged the structural natural vibration period and enhanced seismic performance.Base reactions and floor displacements of various structures notably increased under long-period seismic motion compared to regular seismic activity.Placing isolation bearings in the lower part of the structure proved more effective under long-period seismic motion.In seismic design engineering,it is essential to consider the impact of long-period seismic motion on structures and the potential failure of isolation bearings.展开更多
Inertial reference system is one of the airborne equipment.According to the requirements of SAE ARP4754A Guidelines for Development of Civil Aircraft and Systems,MC9 equipment qualification test is needed to verify th...Inertial reference system is one of the airborne equipment.According to the requirements of SAE ARP4754A Guidelines for Development of Civil Aircraft and Systems,MC9 equipment qualification test is needed to verify that the inertial reference system can perform reservation function under specified service conditions.That is,the inertial reference system shall pass certain environmental tests specified in DO⁃160G.Some tests are faced with the problem that the test equipment should have the function requirements of isolation protection and load simulation.Therefore,a kind of test equipment which can provide isolation protection and simulate load function in the test is designed.展开更多
Currently, land resources are becoming more and more constrained and structures are getting closer to each other. To investigate the seismic response of inter-story isolated structure to adjacent structure, models con...Currently, land resources are becoming more and more constrained and structures are getting closer to each other. To investigate the seismic response of inter-story isolated structure to adjacent structure, models considering no soil-structure interaction (SSI), considering soil-structure interaction (SSI), and considering structure-soil-structure interaction (SSSI) were established. Nonlinear seismic response comparative analysis was conducted by varying the spacing between adjacent structure and inter-story isolated structure, as well as the weight of adjacent structure, under different earthquake inputs, in order to obtain the structural response characteristics. The results indicate that the inter-story drift and inter-story shear of the inter-story isolated structure without considering SSI are smaller than those considering SSI and SSSI. The inter-story drift and inter-story shear of the inter-story isolated structure considering SSSI are further affected compared to that of the inter-story isolated structure considering only SSI. As the spacing between adjacent structure and inter-story isolated structure increases, the influence of adjacent structure on inter-story isolated structure decreases. The variation in the spacing between the two structures has a negligible effect on the isolation layer of the inter-story isolated structure. With the increase in the weight of adjacent structure, the influence of adjacent structure on inter-story isolated structure becomes more significant. The increasing weight of adjacent structure has an increasing effect on the Isolation layer of the inter-story isolated structure.展开更多
[Objective]The aim was to establish optimized system for NER isolated microspore culture of Brassica napus L.. [Method]Twenty varieties of NER of Brassica napus were grown under uncontrolled temperature and light cond...[Objective]The aim was to establish optimized system for NER isolated microspore culture of Brassica napus L.. [Method]Twenty varieties of NER of Brassica napus were grown under uncontrolled temperature and light conditions,and their isolated microspore from anthers were used as explants in vitro culture. The influencing factors of microspore culture were preliminarily studied. [Result]The difference of genotypes was important influencing factors to embryoid yield. The embryoid yield increased by supplementing with 6-BA and NAA,culturing in solid-liquid double layer medium with activated charcoal; The difference was not significant of embryoid yield between culturing in medium supplemented with colchicines and the CK. The rates of cotyledonous embryoids directly developed into normal plantlets increased through enriching with 0.1-0.2 mg/L NAA and being treated on slim illumination two days before being inducted into normal plantlets. [Conclusion]The technical system of microspore culture of restorer of new cytoplasmic male sterile (NER) was established,which and lays a foundation for accelerating genotype purification of NER introgressive line.展开更多
The seismic response of an isolated vertical, cylindrical, extra-large liquefied natural gas (LNG) tank by a multiple friction pendulum system (MFPS) is analyzed. Most of the extra-large LNG tanks have a fundament...The seismic response of an isolated vertical, cylindrical, extra-large liquefied natural gas (LNG) tank by a multiple friction pendulum system (MFPS) is analyzed. Most of the extra-large LNG tanks have a fundamental frequency which involves a range of resonance of most earthquake ground motions. It is an effective way to decrease the response of an isolation system used for extra-large LNG storage tanks under a strong earthquake. However, it is difficult to implement in practice with common isolation bearings due to issues such as low temperature, soft site and other severe environment factors. The extra-large LNG tank isolated by a MFPS is presented in this study to address these problems. A MFPS is appropriate for large displacements induced by earthquakes with long predominant periods. A simplified finite element model by Malhotra and Dunkerley is used to determine the usefulness of the isolation system. Data reported and statistically sorted include pile shear, wave height, impulsive acceleration, convective acceleration and outer tank acceleration. The results show that the isolation system has excellent adaptability for different liquid levels and is very effective in controlling the seismic response of extra-large LNG tanks.展开更多
Gastrointestinal tract involvement by neurofibromatous lesions is rare and occurs most frequently as one of the systemic manifestations of generalized neurofibromatosis type 1 (NF1). In this setting, the lesions may...Gastrointestinal tract involvement by neurofibromatous lesions is rare and occurs most frequently as one of the systemic manifestations of generalized neurofibromatosis type 1 (NF1). In this setting, the lesions may manifest as focal scattered neurofibromas or as an extensive diffuse neural hyperplasia designated ganglioneuromatosis. Occasionally, such lesions may be the initial sign of NF1 in patients without any other clinical manifestations of the disease. Rarely, cases of isolated neurofibromatosis of the large bowel with no prior or subsequent evidence of generalized neurofibromatosis have been documented. We present the case of a 52 year-old female with abdominal pain and alternating bowel habits. Colonoscopic evaluation revealed multiple small polyps in the cecum and the presence of nodular mucosa in the colon and rectum. Pathologic evaluation of the biopsies from the cecum, descending colon, sigmoid colon, and rectum revealed tangled fascicles of spindle cells expanding the lamina propia leading to separation of the intestinal crypts. Immunohistochemical stains helped confirm the diagnosis of diffuse intestinal neurofibromatosis. A thorough clinical evaluation failed to reveal any stigmata of generalized neurofibromatosis. This case represents a rare presentation of isolated intestinal neurofibromatosis in a patient without classic systemic manifestations of generalized neurofibromatosis and highlights the need in such cases for close clinical follow-up to exclude neurofibromatosis type I or multiple endocrine neoplasia type Ⅱ.展开更多
文摘A new staggered isolated system developed from the mid-story isolated system is the new staggered story isolated system. There are not many studies on this structure currently. In this study, an 18-story new staggered story isolated system model is established using SAP2000. The dynamic nonlinear dynamic alternate method is used to analyze the structure against progressive collapse. Results show that the structure has good resistance to progressive collapse, and there is no progressive collapse under each working condition. The progressive collapse does not occur for the case of removing only one vertical structural member of the new staggered of isolated system. The side column has big influence on this isolated structures’ progressive collapse;the removal of vertical structural member of the isolation layer has less impact on the structure than the removal of the bottom vertical structural member. After the removing of the member, the internal force of the structure will be redistributed, and the axial force of the adjacent columns will change obviously, showing a trend of “near large and far small”.
文摘Increasing buildings’ resistance to earthquake forces is not always a desirable solution especially for the building contents that are irreplaceable or simply more valuable than the actual primary structure (e.g. museums, data storage Centre’s, etc.). Base isolation and seismic dampers can be employed to minimize inter-story drifts and floor accelerations via specially designed isolation and dampers system at the structural base, or at higher levels of the superstructure. In this research, we’ll examine the response of buildings isolated using isolation system hybrid consisting of Lead-Rubber Bearings (LRB), Flat Sliding Bearings (FSB), with the addition of Rotation Fiction Damper (FD) at the base, then compare the results with buildings that have traditional foundation, in terms of the (period, displacement and distribution shear force and height of the building). It conducts TIME HISTORY seismic analysis for some varying height buildings (eight, twelve, sixteen, and twenty stories), with help of SAP2000 using an earthquake acceleration-time history for (El- Centro). The results show that the use of insulation system Hybrid has had a significant impact on improving the performance of origin in terms of reducing displacements and base shear with in-creasing height of the building, but has had a negative impact on the drift, which leads to an in-crease in drift with the increased flexibility of the building.
文摘BACKGROUND Isolated left ventricular apical hypoplasia(ILVAH),also known as truncated left ventricle(LV),is a very unusual cardiomyopathy.It is characterised by a truncated,spherical,and non-apex forming LV.The true apex is occupied by the right ventricle.Due to the rarity of the disease,just a few case reports and limited case series have been published in the field.AIM To analysing the so far 37 reported ILVAH cases worldwide.METHODS The electronic databases PubMed and Scopus were investigated from their establishment up to December 13,2022.RESULTS The majority of cases reported occurred in males(52.7%).Mean age at diagnosis was 26.1±19.6 years.More than a third of the patients were asymptomatic(35.1%).The most usual clinical presentation was breathlessness(40.5%).The most commonly detected electrocardiogram changes were T wave abnormalities(29.7%)and right axis deviation with poor R wave progression(24.3%).Atrial fibrillation/flutter was detected in 24.3%.Echocardiography was performed in 97.3%of cases and cardiac MRI in 91.9%of cases.Ejection fraction was reduced in more than a half of patients(56.7%).An associated congenital heart disease was found in 16.2%.Heart failure therapy was administered in 35.1%of patients.The outcome was favorable in the vast majority of patients,with just one death.CONCLUSION ILVAH is a multifaceted entity with a so far unpredictable course,ranging from benign until the elderly to sudden death during adolescence.
基金supported by the National Natural Science Foundation of China[grant number 42105064]the Second Tibetan Plateau Scientific Expedition and Research(STEP)program[grant number 2019QZKK0102]the special fund of the Yunnan University“double first-class”construction.
文摘The Tibetan Plateau(TP)is a prevalent region for convection systems due to its unique thermodynamic forcing.This study investigated isolated deep convections(IDCs),which have a smaller spatial and temporal size than mesoscale convective systems(MCSs),over the TP in the rainy season(June-September)during 2001–2020.The authors used satellite precipitation and brightness temperature observations from the Global Precipitation Measurement mission.Results show that IDCs mainly concentrate over the southern TP.The IDC number per rainy season decreases from around 140 over the southern TP to around 10 over the northern TP,with an average 54.2.The initiation time of IDCs exhibits an obvious diurnal cycle,with the peak at 1400–1500 LST and the valley at 0900–1000 LST.Most IDCs last less than five hours and more than half appear for only one hour.IDCs generally have a cold cloud area of 7422.9 km^(2),containing a precipitation area of approximately 65%.The larger the IDC,the larger the fraction of intense precipitation it contains.IDCs contribute approximately 20%–30%to total precipitation and approximately 30%–40%to extreme precipitation over the TP,with a larger percentage in July and August than in June and September.In terms of spatial distribution,IDCs contribute more to both total precipitation and extreme precipitation over the TP compared to the surrounding plain regions.IDCs over the TP account for a larger fraction than MCSs,indicating the important role of IDCs over the region.
基金National Natural Science Fund of China under Nos.52168072 and 51808467High-level Talents Support Plan of Yunnan Province of China(2020)。
文摘At present,there is not much research on mid-story isolated structures in mountainous areas.In this study,a model of a mid-story isolated structure considering soil-structure interaction(SSI)in mountainous areas is established along with a model that does not consider SSI.Eight long-period earthquake waves and two ordinary earthquake waves are selected as inputs for the dynamic time history analysis of the structure.The results show that the seismic response of a mid-story isolated structure considering SSI in mountainous areas can be amplified when compared with a structure that does not consider SSI.The structure response under long-period earthquakes is larger than that of ordinary earthquakes.The structure response under far-field harmonic-like earthquakes is larger than that of near-fault pulse-type earthquakes.The structure response under near-fault pulse-type earthquakes is larger than that of far-field non-harmonic earthquakes.When subjected to long-period earthquakes,the displacement of the isolated bearings exceeded the limit value,which led to instability and overturning of the structure.The structure with dampers in the isolated story could adequately control the nonlinear response of the structure,effectively reduce the displacement of the isolated bearings,and provide a convenient,efficient and economic method not only for new construction but also to retrofit existing structures.
基金Supported by the National Science and Technology Major Project(2016ZX05029001)CNPC Science and Technology Project(2019D-4310)。
文摘In response to the problems of unclear distribution of deep-water pre-salt carbonate reservoirs and formation conditions of large oil fields in the Santos passive continental margin basin,based on comprehensive utilization of geological,seismic,and core data,and reconstruction of Early Cretaceous prototype basin and lithofacies paleogeography,it is proposed for the first time that the construction of pre-salt carbonate build-ups was controlled by two types of isolated platforms:inter-depression fault-uplift and intra-depression fault-high.The inter-depression fault-uplift isolated platforms are distributed on the present-day pre-salt uplifted zones between depressions,and are built on half-and fault-horst blocks that were inherited and developed in the early intra-continental and inter-continental rift stages.The late intra-continental rift coquinas of the ITP Formation and the early inter-continental rift microbial limestones of the BVE Formation are continuously constructed;intra-depression fault-high isolated platforms are distributed in the current pre-salt depression zones,built on the uplifted zones formed by volcanic rock build-ups in the early prototype stage of intra-continental rifts,and only the BVE microbial limestones are developed.Both types of limestones formed into mound-shoal bodies,that have the characteristics of large reservoir thickness and good physical properties.Based on the dissection of large pre-salt oil fields discovered in the Santos Basin,it has been found that both types of platforms could form large-scale combined structural-stratigraphic traps,surrounded by high-quality lacustrine and lagoon source rocks at the periphery,and efficiently sealed by thick high-quality evaporite rocks above,forming the optimal combination of source,reservoir and cap in the form of“lower generation,middle storage,and upper cap”,with a high degree of oil and gas enrichment.It has been found that the large oil fields are all bottom water massive oil fields with a unified pressure system,and they are all filled to the spill-point.The future exploration is recommended to focus on the inter-depression fault-uplift isolated platforms in the western uplift zone and the southern section of eastern uplift zones,as well as intra-depression fault-high isolated platforms in the central depression zone.The result not only provides an important basis for the advanced selection of potential play fairways,bidding of new blocks,and deployment of awarded exploration blocks in the Santos Basin,but also provides a reference for the global selection of deep-water exploration blocks in passive continental margin basins.
文摘High-efficient isolated DC/DC converters with a high-efficiency synchronous reluctance generator(SRG)are the ultimate solutions in DC microgrid systems.The design and modeling of isolated DC/DC converters with the performance of SRG are carried out.On the generator side,reactive and active powers are used as pulse width modulation(PWM)control variables.Further,the flux estimator is used.Three-phase PWM rectifier is used by applying space vector modulation(SVM)with a constant switching frequency for direct power control.Further,the paper also includes the experimental validation of the results.The paper also proposes that highly efficient power converters and synchronous reluctance generators are required to achieve high performance for hybrid renewable energy systems applications.
文摘BACKGROUND Solitary fibrous tumors(SFT)are rare spindle cell tumors that are usually benign.A total of 10 cases of SFTs in the upper esophagus have ever been reported.Here,we report the anesthetic management of a patient with a large isolated fibrous tumor of the upper esophagus compressing the tracheal membrane.We also provide a literature review of the current research.CASE SUMMARY We report the case of a 49 year old male with“cough aggravation and wheezing after exercise”,who underwent esophagectomy for a large isolated fibrous tumor compressing the tracheal membrane in the upper esophagus.We advise the use of a single-lumen tube with a blocker in patients with difficult airways to reduce the incidence of airway injury and fibrinoscopy at all stages of the perioperative period to guide airway management.This case study is the first report of the anesthetic management of a large,isolated fibrous tumor compressing the tracheal membrane in the upper esophagus.CONCLUSION This rare case emphasizes the importance of perioperative management of anesthesia in patients with large isolated fibrous tumors of the upper esophagus that compress the tracheal membrane.The use of blocker reduce the incidence of airway injury and fibrinoscopy at the perioperative period to guide airway mana-gement.
文摘BACKGROUND The tear of the gluteus medius and minimus tendons can cause chronic buttock pain,especially in middle-aged individuals;these tears occur mostly in association with degenerative changes in the muscles and tendons.Chronic injuries are more common than acute injuries,and concurrent injuries to the gluteus medius and minimus tendons without chronic pain are rare,especially isolated injuries to both sides of the gluteus minimus;such a case has not yet been reported.CASE SUMMARY The authors present a case of bilateral acute traumatic injuries to the gluteus minimus during buttock strengthening exercises in a 75-year-old male patient.The patient completely returned to his pre-injury lifestyle after 8 weeks of injury,with no limitations,but the diagnosis was initially delayed due to misdiagnosis as lumbar radiculopathy,resulting in unnecessary socio-economic burden on the patient.CONCLUSION When treating patients who complain of hip pain,it is important to consider various causes to make a correct diagnosis.
基金partially supported by the Nottingham Ningbo China Beacons of Excellence Research and Innovation Institute (No. I01211200001)LDS 2023 Educational Foundation of The University of Nottingham Ningbo China (No. E06221200002)
文摘The levered-dual response(LEDAR)Coulomb-damped system attains near resonant vibration isolation by differential preloads/offsets in linear springs.It takes the advantages of both the preloads/offsets in linear springs and the guiderail friction for realizing different levels of vibration isolation.The isolation capacities are investigated on the strategies with both the horizontal and vertical guiderails,with the horizontal rail only,and without guiderails.The compressive preloads generally result in the consumption of most of the initial excitation energy so as to overcome the potential threshold.The isolation onsets at the frequency ratio of 1∓0.095 on the left-hand side(LHS)and the right-hand side(RHS)of the lever are relative to the load plate connector.The observed near resonant isolation thus makes the LEDAR system a candidate for the isolation of the mechanical systems about resonance while opening a path for simultaneous harvesterisolation functions and passive functions at extreme frequencies.
基金Supported by Jinhua City Science and Technology Plan Project,China,No.2019-4-027.
文摘BACKGROUND Interventional endoscopic ultrasound is clinically used for the treatment of isolated gastric varices(IGVs)owing to its precise visualization.CASE SUMMARY A 39-year-old man was diagnosed with a large IGV during a routine physical examination.Endoscopic ultrasonography showed gastric varices entwined with an artery,which greatly increased the difficulty of treatment.We successfully treated the patient with endoscopic ultrasonography-guided coil embolization combined with cyanoacrylate injection.CONCLUSION Endoscopic ultrasonography-guided coil embolization combined with cyanoacrylate injection was safe and effective for the treatment of an IGV entwined with an artery.
基金the European Research Council(ERC)under the ERC Synergy grant agreement No.951424(Water-Futures)the European Union’s Horizon 2020 research and innovation programme under grant agreement No.739551(KIOS CoE)the Government of the Republic of Cyprus through the Directorate General for European Programmes,Coordination and Development。
文摘Fault isolation in dynamical systems is a challenging task due to modeling uncertainty and measurement noise,interactive effects of multiple faults and fault propagation.This paper proposes a unified approach for isolation of multiple actuator or sensor faults in a class of nonlinear uncertain dynamical systems.Actuator and sensor fault isolation are accomplished in two independent modules,that monitor the system and are able to isolate the potential faulty actuator(s)or sensor(s).For the sensor fault isolation(SFI)case,a module is designed which monitors the system and utilizes an adaptive isolation threshold on the output residuals computed via a nonlinear estimation scheme that allows the isolation of single/multiple faulty sensor(s).For the actuator fault isolation(AFI)case,a second module is designed,which utilizes a learning-based scheme for adaptive approximation of faulty actuator(s)and,based on a reasoning decision logic and suitably designed AFI thresholds,the faulty actuator(s)set can be determined.The effectiveness of the proposed fault isolation approach developed in this paper is demonstrated through a simulation example.
文摘BACKGROUND Adipose-derived stem cells(ADSCs)and the stromal vascular fraction(SVF)have garnered substantial interest in regenerative medicine due to their potential to treat a wide range of conditions.Traditional enzymatic methods for isolating these cells face challenges such as high costs,lengthy processing time,and regulatory complexities.AIM This systematic review aimed to assess the efficacy and practicality of nonenzymatic,mechanical methods for isolating SVF and ADSCs,comparing these to conventional enzymatic approaches.METHODS Following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines,a comprehensive literature search was conducted across multiple databases.Studies were selected based on inclusion criteria focused on non-enzymatic isolation methods for SVF and ADSCs from adipose tissue.The risk of bias was assessed,and a qualitative synthesis of findings was performed due to the methodological heterogeneity of the included studies.RESULTS Nineteen studies met the inclusion criteria,highlighting various mechanical techniques such as centrifugation,vortexing,and ultrasonic cavitation.The review identified significant variability in cell yield and viability,and the integrity of isolated cells across different non-enzymatic methods compared to enzymatic procedures.Despite some advantages of mechanical methods,including reduced processing time and avoidance of enzymatic reagents,the evidence suggests a need for optimization to match the cell quality and therapeutic efficacy achievable with enzymatic isolation.CONCLUSION Non-enzymatic,mechanical methods offer a promising alternative to enzymatic isolation of SVF and ADSCs,potentially simplifying the isolation process and reducing regulatory hurdles.However,further research is necessary to standardize these techniques and ensure consistent,high-quality cell yields for clinical applications.The development of efficient,safe,and reproducible non-enzymatic isolation methods could significantly advance the field of regenerative medicine.
文摘The aspect ratio of the structure has a significant impact on the overall stability of the ultra high-rise building. A large aspect ratio of the structure increases the risk of overturning and reduces the lateral stiffness of the structure, leading to significant tensile and compressive stresses in the isolated bearings. To study the effect of aspect ratio on the seismic response and overturning resistance of a new staggered story isolated structure, three models with different aspect ratios were established. Nonlinear time-history analysis of the three models was conducted using ETABS finite element software. The results indicate that the overturning moment and overturning resistance moment of the superstructure in the new staggered story isolated structure increase with an increasing aspect ratio. However, the increase in the overturning moment of the superstructure is much greater than the increase in the overturning resistance moment, resulting in a decrease in the overturning resistance ratio of the superstructure with an increasing aspect ratio. The overturning moment and overturning resistance moment of the substructure in the new staggered story isolated structure decrease with an increasing aspect ratio. However, the decrease in the overturning moment of the substructure is greater than the decrease in the overturning resistance moment, leading to an increase in the overturning resistance ratio of the substructure with an increasing aspect ratio. The decrease in the overturning resistance ratio of the superstructure in the new staggered story isolated structure is much greater than the increase in the overturning resistance ratio of the substructure. Therefore, as the aspect ratio of the overall structure increases, the overturning resistance ratio of the superstructure and the entire structure decreases.
基金Anhui Province Young and Middle-aged Teacher Training Action Excellent Young Teacher Cultivation Project(YQYB2023162)Anhui University Natural Science Research Key Project(KJ2021A1410)Special Topic of the Higher Education Institution Scientific Research Development Center of the Ministry of Education(ZJXF2022080)。
文摘To analyze the seismic response of steel structure isolation systems under long-period seismic motion,a 9-story steel frame building was selected as the subject.Five steel structure finite element models were established using SAP2000.Response spectrum analysis was conducted on the seismic motion to determine if it adhered to the characteristics of long-period seismic motion.Modal analysis of each structural model revealed that the isolation structure significantly prolonged the structural natural vibration period and enhanced seismic performance.Base reactions and floor displacements of various structures notably increased under long-period seismic motion compared to regular seismic activity.Placing isolation bearings in the lower part of the structure proved more effective under long-period seismic motion.In seismic design engineering,it is essential to consider the impact of long-period seismic motion on structures and the potential failure of isolation bearings.
文摘Inertial reference system is one of the airborne equipment.According to the requirements of SAE ARP4754A Guidelines for Development of Civil Aircraft and Systems,MC9 equipment qualification test is needed to verify that the inertial reference system can perform reservation function under specified service conditions.That is,the inertial reference system shall pass certain environmental tests specified in DO⁃160G.Some tests are faced with the problem that the test equipment should have the function requirements of isolation protection and load simulation.Therefore,a kind of test equipment which can provide isolation protection and simulate load function in the test is designed.
文摘Currently, land resources are becoming more and more constrained and structures are getting closer to each other. To investigate the seismic response of inter-story isolated structure to adjacent structure, models considering no soil-structure interaction (SSI), considering soil-structure interaction (SSI), and considering structure-soil-structure interaction (SSSI) were established. Nonlinear seismic response comparative analysis was conducted by varying the spacing between adjacent structure and inter-story isolated structure, as well as the weight of adjacent structure, under different earthquake inputs, in order to obtain the structural response characteristics. The results indicate that the inter-story drift and inter-story shear of the inter-story isolated structure without considering SSI are smaller than those considering SSI and SSSI. The inter-story drift and inter-story shear of the inter-story isolated structure considering SSSI are further affected compared to that of the inter-story isolated structure considering only SSI. As the spacing between adjacent structure and inter-story isolated structure increases, the influence of adjacent structure on inter-story isolated structure decreases. The variation in the spacing between the two structures has a negligible effect on the isolation layer of the inter-story isolated structure. With the increase in the weight of adjacent structure, the influence of adjacent structure on inter-story isolated structure becomes more significant. The increasing weight of adjacent structure has an increasing effect on the Isolation layer of the inter-story isolated structure.
基金Supported by the Key Breeding Project of Sichuan Province during National Eleventh-five Year Plan (2006YZGG25 )Key Quality Project of Sichuan Province (2006YZGG223)Foundation for Young Scientists of Sichuan Provincial Financial Breeding Project in 2008~~
文摘[Objective]The aim was to establish optimized system for NER isolated microspore culture of Brassica napus L.. [Method]Twenty varieties of NER of Brassica napus were grown under uncontrolled temperature and light conditions,and their isolated microspore from anthers were used as explants in vitro culture. The influencing factors of microspore culture were preliminarily studied. [Result]The difference of genotypes was important influencing factors to embryoid yield. The embryoid yield increased by supplementing with 6-BA and NAA,culturing in solid-liquid double layer medium with activated charcoal; The difference was not significant of embryoid yield between culturing in medium supplemented with colchicines and the CK. The rates of cotyledonous embryoids directly developed into normal plantlets increased through enriching with 0.1-0.2 mg/L NAA and being treated on slim illumination two days before being inducted into normal plantlets. [Conclusion]The technical system of microspore culture of restorer of new cytoplasmic male sterile (NER) was established,which and lays a foundation for accelerating genotype purification of NER introgressive line.
基金Foundation of Basic Research Program of State Key Laboratory from Ministry of Science and Technology of China Under Grant No. SLDRCE10-D-01Foundation of Shanghai Engineering Technical Research Centre Under Grant No. 10DZ2252000
文摘The seismic response of an isolated vertical, cylindrical, extra-large liquefied natural gas (LNG) tank by a multiple friction pendulum system (MFPS) is analyzed. Most of the extra-large LNG tanks have a fundamental frequency which involves a range of resonance of most earthquake ground motions. It is an effective way to decrease the response of an isolation system used for extra-large LNG storage tanks under a strong earthquake. However, it is difficult to implement in practice with common isolation bearings due to issues such as low temperature, soft site and other severe environment factors. The extra-large LNG tank isolated by a MFPS is presented in this study to address these problems. A MFPS is appropriate for large displacements induced by earthquakes with long predominant periods. A simplified finite element model by Malhotra and Dunkerley is used to determine the usefulness of the isolation system. Data reported and statistically sorted include pile shear, wave height, impulsive acceleration, convective acceleration and outer tank acceleration. The results show that the isolation system has excellent adaptability for different liquid levels and is very effective in controlling the seismic response of extra-large LNG tanks.
文摘Gastrointestinal tract involvement by neurofibromatous lesions is rare and occurs most frequently as one of the systemic manifestations of generalized neurofibromatosis type 1 (NF1). In this setting, the lesions may manifest as focal scattered neurofibromas or as an extensive diffuse neural hyperplasia designated ganglioneuromatosis. Occasionally, such lesions may be the initial sign of NF1 in patients without any other clinical manifestations of the disease. Rarely, cases of isolated neurofibromatosis of the large bowel with no prior or subsequent evidence of generalized neurofibromatosis have been documented. We present the case of a 52 year-old female with abdominal pain and alternating bowel habits. Colonoscopic evaluation revealed multiple small polyps in the cecum and the presence of nodular mucosa in the colon and rectum. Pathologic evaluation of the biopsies from the cecum, descending colon, sigmoid colon, and rectum revealed tangled fascicles of spindle cells expanding the lamina propia leading to separation of the intestinal crypts. Immunohistochemical stains helped confirm the diagnosis of diffuse intestinal neurofibromatosis. A thorough clinical evaluation failed to reveal any stigmata of generalized neurofibromatosis. This case represents a rare presentation of isolated intestinal neurofibromatosis in a patient without classic systemic manifestations of generalized neurofibromatosis and highlights the need in such cases for close clinical follow-up to exclude neurofibromatosis type I or multiple endocrine neoplasia type Ⅱ.