To solve the uneven burden of same-type holes reducing the blasting efficiency due to the limitation of drilling equipment,we need a double-face program-controlled planning method for hole position parameters used on ...To solve the uneven burden of same-type holes reducing the blasting efficiency due to the limitation of drilling equipment,we need a double-face program-controlled planning method for hole position parameters used on a computer-controlled drilling jumbo.The cross-section splits into even and uneven areas.It also considers the uneven burden at the hole’s entrance and bottom.In the uneven area,various qualifying factors are made to optimize the hole spacing and maximize the burden uniformity,combined with the features of the area edges and gridbased segmentation methods.The hole position coordinates and angles in the even area are derived using recursion and iteration algorithms.As a case,this method presents all holes in a 4.8 m wide and 3.6 m high cross-section.Compared with the design produced by the drawing method,our planning in the uneven area improved the standard deviation of the hole burden by 40%.The improved hole layout facilitates the evolution of precise,efficient,and intelligent blasting in underground mines.展开更多
This paper describes the force acting the assembly of the jumbo rig for tunneling.The finite element analysis is used to calculate this machine structure on its different working states.
Although many studies on the fishery biology of jumbo flying squid, Dosidicus gigas, have been conducted in the coastal areas within Exclusive Economic Zones (EEZs) of various countries due to its commercial and eco...Although many studies on the fishery biology of jumbo flying squid, Dosidicus gigas, have been conducted in the coastal areas within Exclusive Economic Zones (EEZs) of various countries due to its commercial and ecological importance, limited biological information is available from waters outside these EEZs. In this paper, we examined D. gigas fishery biology from waters outside Chilean, Peruvian and Costa Rican EEZs, based on the fishery data collected by Chinese jigging vessels during 2006 to 2010. The dominant mantle lengths olD. gigas were 350-450 mm, 250-400 mm and 250-350 mm outside Chilean, Peruvian and Costa Rican EEZs, respectively. Size structure analysis show that a medium-sized group existed mostly in the waters outside the Chilean and Peruvian EEZs, whereas a small-sized group occurred mainly in the waters outside the Costa Rican EEZ. The longevity of the squid outside the Costa Rican EEZ was less than 10 months, while most of those outside Chilean and Peruvian EEZs were about 1-1.5 years and very few large individuals were 1.5-2 years old. A higher percentage of mature individuals existed outside Costa Rican EEZ implying the region as a potential spawning ground, while lower proportions of mature squid outside the Peruvian and Chilean EEZs indicated that spawning may be occurring outside our study area. Spatial differences in sizes at maturity of the squid are thought to be result from different environmental factors especially different temperature and nutrition among the three areas. Stomach-content analysis showed that cannibalism was important in the diet of D. gigas. Stress generated by jigging may increase the incidence of cannibalism.展开更多
We report here a case of multiple prolapsing mucosal polyps with diverticulosis in the sigmoid colon. A 52-year- old man was admitted to our hospital because of bloody diarrhea. Colonoscopy and barium enema showed mul...We report here a case of multiple prolapsing mucosal polyps with diverticulosis in the sigmoid colon. A 52-year- old man was admitted to our hospital because of bloody diarrhea. Colonoscopy and barium enema showed multiple diverticula, markedly thickened mucosal folds and polypoid lesions with mucus on the top of them in the sigmoid colon. Endoscopic ultrasonography showed thickening of the mucosal and submucosal layers. Several endoscopic biopsy specimens were taken from the polypoid lesions. Histological examination revealed only chronic inflammatory cell infiltration. In order to obtain a definite diagnosis, we performed endoscopic jumbo biopsy for the polypoid lesions after obtaining informed consent. Histological examination revealed marked lymphocyte infiltration, hemosiderin deposits and fibromuscular obliteration in the lamina propria, features similar to those of mucosal prolapsing syndrome. After anti-diarrhetic treatment, clinical findings were improved. Thus, jumbo biopsy is useful for diagnosis and treatment of prolapsing mucosal polyps.展开更多
BACKGROUND Utilizing the large jumbo cup in revision total hip arthroplasty is an effective approach to cure many lacunar and segmental peripheral bone defects.However,with the use of the jumbo cup,the center of the h...BACKGROUND Utilizing the large jumbo cup in revision total hip arthroplasty is an effective approach to cure many lacunar and segmental peripheral bone defects.However,with the use of the jumbo cup,the center of the hip joint may become elevated relative to the primary acetabulum,and the diameter of the large cup is greater.AIM To study the height and the significance of the elevation of the hip joint center.METHODS Eighty-eight patients matched the criteria for this condition and were included in the study.The center height of the hip joint was measured relative to the opposite normal hip joint.The diameter of the jumbo cup was measured and checked according to operation notes,and the diameter of the jumbo cup was measured with a prosthesis label.Then,the horizontal and vertical centers of rotation were measured on the surgical side and opposite side.The average center height of the hip joint on the renovated side and the opposite side and the position of the hip cup relative to the teardrop were compared using a paired t-test.RESULTS Radiometric analysis showed that the average hip joint center was elevated by 7.6 mm.The rotational center height delta of the renovated hip was 7.6±5.6 mm,and there was an obvious difference between the two groups(P=0.00).The difference in horizontal distance was 0.5±5.1 mm(-11.5-14.0 mm),and there was no obvious difference between the two groups(P=0.38).According to the foreign standard,the rotational center height delta of the renovated hip was 7.5±6.2 mm,and there was a significant difference between the two groups(P=0.00).There was no obvious difference between the domestic and foreign standards(P>0.05)between the two groups.CONCLUSION The application of the jumbo cup elevates the rotational center of the hip joint,but it is feasible and effective to use the jumbo cup.展开更多
AIM:To assess the sampling quality of four different forceps(three large capacity and one jumbo) in patients with Barrett's esophagus.METHODS:This was a prospective,single-blind study.A total of 37 patients with B...AIM:To assess the sampling quality of four different forceps(three large capacity and one jumbo) in patients with Barrett's esophagus.METHODS:This was a prospective,single-blind study.A total of 37 patients with Barrett's esophagus were enrolled.Targeted or random biopsies with all four forceps were obtained from each patient using a diagnostic endoscope during a single endoscopy.The following forceps were tested:A:FB-220 K disposable large capacity;B:BI01-D3-23 reusable large capacity;C:GBF-02-23-180 disposable large capacity;and jumbo:disposable Radial Jaw 4 jumbo.The primary outcome measurement was specimen adequacy,defined as a well-oriented biopsy sample 2 mm or greater with the presence of muscularis mucosa.RESULTS:A total of 436 biopsy samples were analyzed.We found a significantly higher proportion of adequate biopsy samples with jumbo forceps(71%)(P < 0.001 vs forceps A:26%,forceps B:17%,and forceps C:18%).Biopsies with jumbo forceps had the largest diameter(median 2.4 mm)(P < 0.001 vs forceps A:2 mm,forceps B:1.6 mm,and forceps C:2mm).There was a trend for higher diagnostic yield per biopsy with jumbo forceps(forceps A:0.20,forceps B:0.22,forceps C:0.27,and jumbo:0.28).No complications related to specimen sampling were observed with any of the four tested forceps.CONCLUSION:Jumbo biopsy forceps,when used with a diagnostic endoscope,provide more adequate specimens as compared to large-capacity forceps in patients with Barrett's esophagus.展开更多
We present a rare case of fecaloma, 7 cm in size, in the setting of systemic scleroderma. A colonoscopy revealed a giant brown fecaloma occupying the lumen of the colon and a colonic ulcer that was caused by the fecal...We present a rare case of fecaloma, 7 cm in size, in the setting of systemic scleroderma. A colonoscopy revealed a giant brown fecaloma occupying the lumen of the colon and a colonic ulcer that was caused by the fecaloma. The surface of the fecaloma was hard, large and slippery, and fragmentation was not possible despite the use of various devices, including standard biopsy forceps, an injection needle, and a snare. However, jumbo forceps were able to shave the surface of the fecaloma and break it successfully by repeated biting for 6 h over 2 d. The ability of the jumbo forceps to collect large mucosal samples was also appropriate for achieving fragmentation of the giant fecaloma.展开更多
The biomechanical effects of acetabular revision with jumbo cups are unclear.This study aimed to compare the biomechanical effects of bionic trabecular metal vs.titanium jumbo cups for the revision of acetabular bone ...The biomechanical effects of acetabular revision with jumbo cups are unclear.This study aimed to compare the biomechanical effects of bionic trabecular metal vs.titanium jumbo cups for the revision of acetabular bone defects.We designed and reconstructed American Academy of Orthopaedic Surgeons(AAOS)type I–III acetabular bone defect models using computed tomography scans of a man without acetabular bone defects.The implantation of titanium and trabecular metal jumbo cups was simulated.Stress distribution and relative micromotion between the cup and host bone were assessed using finite element analysis.Contact stress on the screws fixing the cups was also analyzed.The contact stress analysis showed that the peak contact stress between the titanium jumbo cup and the host bone was 21.7,20.1,and 23.8 MPa in the AAOS I–III models,respectively;the corresponding values for bionic tantalum jumbo cups decreased to 4.7,6.7,and 11.1 MPa.Analysis of the relative micromotion showed that the peak relative micromotion between the host bone and the titanium metal cup was 10.2,9.1,and 11.5μm in the AAOS I–III models,respectively;the corresponding values for bionic trabecular metal cups were 17.2,18.2,and 31.3μm.The peak contact stress on the screws was similar for the 2 cup types,and was concentrated on the screw rods.Hence,acetabular reconstruction with jumbo cups is biomechanically feasible.We recommend trabecular metal cups due to their superior stress distribution and higher relative micromotion,which is within the threshold for adequate bone ingrowth.展开更多
基金financially supported by the Fundamental Research Funds for the Central Universities(No.FRF-AT-19-005)the National Natural Science Foundation of China(No.51934001).
文摘To solve the uneven burden of same-type holes reducing the blasting efficiency due to the limitation of drilling equipment,we need a double-face program-controlled planning method for hole position parameters used on a computer-controlled drilling jumbo.The cross-section splits into even and uneven areas.It also considers the uneven burden at the hole’s entrance and bottom.In the uneven area,various qualifying factors are made to optimize the hole spacing and maximize the burden uniformity,combined with the features of the area edges and gridbased segmentation methods.The hole position coordinates and angles in the even area are derived using recursion and iteration algorithms.As a case,this method presents all holes in a 4.8 m wide and 3.6 m high cross-section.Compared with the design produced by the drawing method,our planning in the uneven area improved the standard deviation of the hole burden by 40%.The improved hole layout facilitates the evolution of precise,efficient,and intelligent blasting in underground mines.
文摘This paper describes the force acting the assembly of the jumbo rig for tunneling.The finite element analysis is used to calculate this machine structure on its different working states.
基金Supported by the National Natural Science Foundation of China(No.NSFC41276156)Innovation Program of Shanghai Municipal Education Commission(No.13YE091)+5 种基金Industrialization Project of National Development and Reform Commission(No.2159999)Project of Shanghai Science and Technology Commission(No.12231203900)National High Technology Research and Development Program of China(863 Program)(No.2012AA092303)Shanghai Leading Academic Discipline Project(Fisheries Discipline)National Distant-Water Fisheries Engineering Research Centerthe Scientific Observing and Experimental Station of Oceanic Fishery Resources,Ministry of Agriculture
文摘Although many studies on the fishery biology of jumbo flying squid, Dosidicus gigas, have been conducted in the coastal areas within Exclusive Economic Zones (EEZs) of various countries due to its commercial and ecological importance, limited biological information is available from waters outside these EEZs. In this paper, we examined D. gigas fishery biology from waters outside Chilean, Peruvian and Costa Rican EEZs, based on the fishery data collected by Chinese jigging vessels during 2006 to 2010. The dominant mantle lengths olD. gigas were 350-450 mm, 250-400 mm and 250-350 mm outside Chilean, Peruvian and Costa Rican EEZs, respectively. Size structure analysis show that a medium-sized group existed mostly in the waters outside the Chilean and Peruvian EEZs, whereas a small-sized group occurred mainly in the waters outside the Costa Rican EEZ. The longevity of the squid outside the Costa Rican EEZ was less than 10 months, while most of those outside Chilean and Peruvian EEZs were about 1-1.5 years and very few large individuals were 1.5-2 years old. A higher percentage of mature individuals existed outside Costa Rican EEZ implying the region as a potential spawning ground, while lower proportions of mature squid outside the Peruvian and Chilean EEZs indicated that spawning may be occurring outside our study area. Spatial differences in sizes at maturity of the squid are thought to be result from different environmental factors especially different temperature and nutrition among the three areas. Stomach-content analysis showed that cannibalism was important in the diet of D. gigas. Stress generated by jigging may increase the incidence of cannibalism.
文摘We report here a case of multiple prolapsing mucosal polyps with diverticulosis in the sigmoid colon. A 52-year- old man was admitted to our hospital because of bloody diarrhea. Colonoscopy and barium enema showed multiple diverticula, markedly thickened mucosal folds and polypoid lesions with mucus on the top of them in the sigmoid colon. Endoscopic ultrasonography showed thickening of the mucosal and submucosal layers. Several endoscopic biopsy specimens were taken from the polypoid lesions. Histological examination revealed only chronic inflammatory cell infiltration. In order to obtain a definite diagnosis, we performed endoscopic jumbo biopsy for the polypoid lesions after obtaining informed consent. Histological examination revealed marked lymphocyte infiltration, hemosiderin deposits and fibromuscular obliteration in the lamina propria, features similar to those of mucosal prolapsing syndrome. After anti-diarrhetic treatment, clinical findings were improved. Thus, jumbo biopsy is useful for diagnosis and treatment of prolapsing mucosal polyps.
文摘BACKGROUND Utilizing the large jumbo cup in revision total hip arthroplasty is an effective approach to cure many lacunar and segmental peripheral bone defects.However,with the use of the jumbo cup,the center of the hip joint may become elevated relative to the primary acetabulum,and the diameter of the large cup is greater.AIM To study the height and the significance of the elevation of the hip joint center.METHODS Eighty-eight patients matched the criteria for this condition and were included in the study.The center height of the hip joint was measured relative to the opposite normal hip joint.The diameter of the jumbo cup was measured and checked according to operation notes,and the diameter of the jumbo cup was measured with a prosthesis label.Then,the horizontal and vertical centers of rotation were measured on the surgical side and opposite side.The average center height of the hip joint on the renovated side and the opposite side and the position of the hip cup relative to the teardrop were compared using a paired t-test.RESULTS Radiometric analysis showed that the average hip joint center was elevated by 7.6 mm.The rotational center height delta of the renovated hip was 7.6±5.6 mm,and there was an obvious difference between the two groups(P=0.00).The difference in horizontal distance was 0.5±5.1 mm(-11.5-14.0 mm),and there was no obvious difference between the two groups(P=0.38).According to the foreign standard,the rotational center height delta of the renovated hip was 7.5±6.2 mm,and there was a significant difference between the two groups(P=0.00).There was no obvious difference between the domestic and foreign standards(P>0.05)between the two groups.CONCLUSION The application of the jumbo cup elevates the rotational center of the hip joint,but it is feasible and effective to use the jumbo cup.
文摘AIM:To assess the sampling quality of four different forceps(three large capacity and one jumbo) in patients with Barrett's esophagus.METHODS:This was a prospective,single-blind study.A total of 37 patients with Barrett's esophagus were enrolled.Targeted or random biopsies with all four forceps were obtained from each patient using a diagnostic endoscope during a single endoscopy.The following forceps were tested:A:FB-220 K disposable large capacity;B:BI01-D3-23 reusable large capacity;C:GBF-02-23-180 disposable large capacity;and jumbo:disposable Radial Jaw 4 jumbo.The primary outcome measurement was specimen adequacy,defined as a well-oriented biopsy sample 2 mm or greater with the presence of muscularis mucosa.RESULTS:A total of 436 biopsy samples were analyzed.We found a significantly higher proportion of adequate biopsy samples with jumbo forceps(71%)(P < 0.001 vs forceps A:26%,forceps B:17%,and forceps C:18%).Biopsies with jumbo forceps had the largest diameter(median 2.4 mm)(P < 0.001 vs forceps A:2 mm,forceps B:1.6 mm,and forceps C:2mm).There was a trend for higher diagnostic yield per biopsy with jumbo forceps(forceps A:0.20,forceps B:0.22,forceps C:0.27,and jumbo:0.28).No complications related to specimen sampling were observed with any of the four tested forceps.CONCLUSION:Jumbo biopsy forceps,when used with a diagnostic endoscope,provide more adequate specimens as compared to large-capacity forceps in patients with Barrett's esophagus.
文摘We present a rare case of fecaloma, 7 cm in size, in the setting of systemic scleroderma. A colonoscopy revealed a giant brown fecaloma occupying the lumen of the colon and a colonic ulcer that was caused by the fecaloma. The surface of the fecaloma was hard, large and slippery, and fragmentation was not possible despite the use of various devices, including standard biopsy forceps, an injection needle, and a snare. However, jumbo forceps were able to shave the surface of the fecaloma and break it successfully by repeated biting for 6 h over 2 d. The ability of the jumbo forceps to collect large mucosal samples was also appropriate for achieving fragmentation of the giant fecaloma.
基金This work was supported by funding from China Postdoctoral Science Foundation(No:2020M670863)Jilin Scientific and Technological Development Program(No:20230203089SF).
文摘The biomechanical effects of acetabular revision with jumbo cups are unclear.This study aimed to compare the biomechanical effects of bionic trabecular metal vs.titanium jumbo cups for the revision of acetabular bone defects.We designed and reconstructed American Academy of Orthopaedic Surgeons(AAOS)type I–III acetabular bone defect models using computed tomography scans of a man without acetabular bone defects.The implantation of titanium and trabecular metal jumbo cups was simulated.Stress distribution and relative micromotion between the cup and host bone were assessed using finite element analysis.Contact stress on the screws fixing the cups was also analyzed.The contact stress analysis showed that the peak contact stress between the titanium jumbo cup and the host bone was 21.7,20.1,and 23.8 MPa in the AAOS I–III models,respectively;the corresponding values for bionic tantalum jumbo cups decreased to 4.7,6.7,and 11.1 MPa.Analysis of the relative micromotion showed that the peak relative micromotion between the host bone and the titanium metal cup was 10.2,9.1,and 11.5μm in the AAOS I–III models,respectively;the corresponding values for bionic trabecular metal cups were 17.2,18.2,and 31.3μm.The peak contact stress on the screws was similar for the 2 cup types,and was concentrated on the screw rods.Hence,acetabular reconstruction with jumbo cups is biomechanically feasible.We recommend trabecular metal cups due to their superior stress distribution and higher relative micromotion,which is within the threshold for adequate bone ingrowth.