期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Fenestrated endovascular aortic repair for juxtarenal abdominal aortic aneurysm 被引量:2
1
作者 GUO Wei ZHANG Hong-peng LIU Xiao-ping JIA Xin XIONG Jiang MA Xiao-hui 《Chinese Medical Journal》 SCIE CAS CSCD 2013年第3期409-414,共6页
Background Endovascular stent-graft with fenestration can improve proximal sealing in patients with juxtarenal abdominal aortic aneurysm (JAAA). The purpose of this study was to describe our primary experience and e... Background Endovascular stent-graft with fenestration can improve proximal sealing in patients with juxtarenal abdominal aortic aneurysm (JAAA). The purpose of this study was to describe our primary experience and evaluate the safety and efficacy of fenestrated device for JAAA in high-risk patients. Methods Between March 2011 and May 2012, nine male patients (mean age, (79.6±8.6) years) with asymptomatic JAAAs underwent elective deployment of the Zenith fenestrated stent-grafts at a single institution. All patients were treated in the hybrid operating room under general anesthesia. Follow-up computed tomography angiography (CTA) was routinely performed before discharge, at 3, 6, and 12 months and annually thereafter. Results Procedural success was achieved in all cases. Total sixteen small fenestrations, two large fenestrations and eight scallops were used. Intra-operative complications occurred in four patients, which included one proximal type I endoleak, two type II endoleaks, and one renal artery dissection. The mean hospital stay was (8.9±1.4) days, mean blood loss was (360.5±46.8) ml, and mean iodinated contrast volume was (230.6±58.3) ml. The mean follow-up time was (7.6±4.2) months. The visceral graft patency was 100% until now. One patient had an increase of serum creatinine of more than 30%, but did not require dialysis. No patients died, no stent fractured, and migration were diagnosed during the follow-up. Conclusions The early results of fenestrated device for high-risk patients with complex JAAAs are satisfactory. However, long-term fenestrated graft durability and branch vessel patency remain to be determined. 展开更多
关键词 abdominal aortic aneurysm juxtarenal aneurysm endovascular aortic repair fenestrated stent-graft
原文传递
Antegrade in situ laser fenestration of aortic stent graft during endovascular aortic repair:A case report
2
作者 Zhi-Wei Wang Zhen-Tao Qiao +3 位作者 Ming-Xing Li Hua-Long Bai Yuan-Feng Liu Tao Bai 《World Journal of Clinical Cases》 SCIE 2022年第4期1401-1409,共9页
BACKGROUND The endovascular repair of juxtarenal abdominal aortic aneurysms(JAAA)usually requires combination treatment with various stent graft modifications to preserve side branch patency.As a feasible technique,ac... BACKGROUND The endovascular repair of juxtarenal abdominal aortic aneurysms(JAAA)usually requires combination treatment with various stent graft modifications to preserve side branch patency.As a feasible technique,according to the situation,antegrade in situ laser fenestration still needs to be improved.CASE SUMMARY This report describes a case that was successfully treated with endovascular repair facilitated by antegrade in situ laser fenestration while maintaining renal arterial flow.Laser fenestration was performed using a steerable sheath positioned in the stent graft lumen in front of the renal artery ostium.With the bare stent region unreleased,renal artery perfusion could be maintained and accurate positioning could be achieved by angiography in real time.CONCLUSION This study suggests the feasibility and short-term safety of this novel antegrade in situ laser fenestration technique for select JAAA patients. 展开更多
关键词 juxtarenal abdominal aortic aneurysm In situ fenestration Thoracic endovascular aortic repair ANTEGRADE Case report
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部