Radio Frequency (RF) switch circuit is the basic part of microwave devices and systems. The non-linearity distortion figure is necessary in the field of large dynamic range of signal. This letter analyzes the basic sw...Radio Frequency (RF) switch circuit is the basic part of microwave devices and systems. The non-linearity distortion figure is necessary in the field of large dynamic range of signal. This letter analyzes the basic switch circuit and its inter-modulation, and studies in detail the measurement methods and systems of RF switch intercept point. It has provided cascaded simulation testing methods, which can accurately measure the PF switch, of which the second or third order intercept point value is above 75dB and 60dB, respectively. As the testing results are consistent with the theoretical analyses, it proves that the validity of the method satisfies the requirements of large scaled linearity measurement in engineering.展开更多
The Shack-Hartmann wavefront sensor(SHWS)is widely used for high-speed,precise,and stable wavefront measurements.However,conventional SHWSs encounter a limitation in that the focused spot from each microlens is restri...The Shack-Hartmann wavefront sensor(SHWS)is widely used for high-speed,precise,and stable wavefront measurements.However,conventional SHWSs encounter a limitation in that the focused spot from each microlens is restricted to a single microlens,leading to a limited dynamic range.Herein,we propose an adaptive spot matching(ASM)-based SHWS to extend the dynamic range.This approach involves seeking an incident wavefront that best matches the detected spot distribution by employing a Hausdorff-distance-based nearest-distance matching strategy.The ASM-SHWS enables comprehensive spot matching across the entire imaging plane without requiring initial spot correspondences.Furthermore,due to its global matching capability,ASM-SHWS can maintain its capacity even if a portion of the spots are missing.Experiments showed that the ASM-SHWS could measure a high-curvature spherical wavefront with a local slope of 204.97 mrad,despite a 12.5%absence of spots.This value exceeds that of the conventional SHWS by a factor of 14.81.展开更多
In the future, the Very Large Area gamma-ray Space Telescope is expected to observe high-energy electrons and gamma rays in the MeV to TeV range with unprecedented acceptance. As part of the detector suite, a high-ene...In the future, the Very Large Area gamma-ray Space Telescope is expected to observe high-energy electrons and gamma rays in the MeV to TeV range with unprecedented acceptance. As part of the detector suite, a high-energy imaging calorimeter(HEIC) is currently being developed as a homogeneous calorimeter that utilizes long bismuth germanate(BGO) scintillation crystals as both absorbers and detectors. To accurately measure the energy deposition in the BGO bar of HEIC, a highdynamic-range readout method using a silicon photomultiplier(SiPM) and multiphotodiode(PD) with different active areas has been proposed. A prototype readout system that adopts multichannel charge measurement ASICs was also developed to read out the combined system of SiPMs and PDs. Preliminary tests confirmed the feasibility of the readout scheme, which is expected to have a dynamic range close to 10~6.展开更多
China plans to develop the next generation dark matter particle explorer satellite,referred to as the Very Large Area Space Telescope(VLAST).As an essential step in this process,the prototype design of detectors and e...China plans to develop the next generation dark matter particle explorer satellite,referred to as the Very Large Area Space Telescope(VLAST).As an essential step in this process,the prototype design of detectors and electronics for the VLAST is currently underway.The nuclide detector is a core detector in the VLAST.It mainly measures nuclides’charges and distinguishes high-energy gamma rays and electrons.This paper will discuss the prototype readout electronics for the VLAST’s nuclide detector,which accurately measures the charge signal of the photomultiplier tubes using the VATA160 applicationspecific integrated circuit chip;furthermore,we consider a series of critical problems,including radiation-hardening and environment monitoring.The test results show that the system exhibits stable operation,good performance,and good technical indicators.Furthermore,each electronic channel achieves a dynamic range of 0-12.5 pC,the random noise level exceeds 1.6 fC,and the integral nonlinearity exceeds 0.35%.展开更多
The ASIC is widely used in the field of high energy physics. Astroparticle experiments benefit from high integration, smallsize and low power consumption. In this paper an analog chip named ARCHGARD (Analog Readout Ch...The ASIC is widely used in the field of high energy physics. Astroparticle experiments benefit from high integration, smallsize and low power consumption. In this paper an analog chip named ARCHGARD (Analog Readout Chip for High energyGamma Ray Detector) for high energy physics experiment is introduced. ARCHGARD is a readout chip, in chartered 0.35 mSiGe technology, for photomultipliers (PMT) array readout. The chip is designed for the Large High Altitude Air Shower Ob-servatory (LHAASO) project. The ASIC integrates 16 independent and auto-triggered channels with variable gain and variableshaping time. It provides analog output for charge measurement, which is performed from 1 up to 3000 photo-electrons (p.e.).The integral nonlinearity of the whole input range is less than 1% and the equivalent input noise is less than 1/10 p.e. Eachchannel has a trigger output for time measurement.展开更多
文摘Radio Frequency (RF) switch circuit is the basic part of microwave devices and systems. The non-linearity distortion figure is necessary in the field of large dynamic range of signal. This letter analyzes the basic switch circuit and its inter-modulation, and studies in detail the measurement methods and systems of RF switch intercept point. It has provided cascaded simulation testing methods, which can accurately measure the PF switch, of which the second or third order intercept point value is above 75dB and 60dB, respectively. As the testing results are consistent with the theoretical analyses, it proves that the validity of the method satisfies the requirements of large scaled linearity measurement in engineering.
基金supported by the Fundamental Research Funds for the Central Universities of Shanghai Jiao Tong University and the Shanghai Jiao Tong University 2030 Initiative(No.WH510363001-10)the Oceanic Interdisciplinary Program of Shanghai Jiao Tong University(No.SL2022ZD205)+1 种基金the Science Foundation of the Donghai Laboratory(No.DH-2022KF01001)National Natural Science Foundation of China(No.62205189).
文摘The Shack-Hartmann wavefront sensor(SHWS)is widely used for high-speed,precise,and stable wavefront measurements.However,conventional SHWSs encounter a limitation in that the focused spot from each microlens is restricted to a single microlens,leading to a limited dynamic range.Herein,we propose an adaptive spot matching(ASM)-based SHWS to extend the dynamic range.This approach involves seeking an incident wavefront that best matches the detected spot distribution by employing a Hausdorff-distance-based nearest-distance matching strategy.The ASM-SHWS enables comprehensive spot matching across the entire imaging plane without requiring initial spot correspondences.Furthermore,due to its global matching capability,ASM-SHWS can maintain its capacity even if a portion of the spots are missing.Experiments showed that the ASM-SHWS could measure a high-curvature spherical wavefront with a local slope of 204.97 mrad,despite a 12.5%absence of spots.This value exceeds that of the conventional SHWS by a factor of 14.81.
基金Foundation of China (Nos. 12227805, U1831206, 12103095, 12235012, 12273120, and 11973097)the Scientific Instrument Developing Project of the Chinese Academy of Sciences (No. GJJSTD20210009)。
文摘In the future, the Very Large Area gamma-ray Space Telescope is expected to observe high-energy electrons and gamma rays in the MeV to TeV range with unprecedented acceptance. As part of the detector suite, a high-energy imaging calorimeter(HEIC) is currently being developed as a homogeneous calorimeter that utilizes long bismuth germanate(BGO) scintillation crystals as both absorbers and detectors. To accurately measure the energy deposition in the BGO bar of HEIC, a highdynamic-range readout method using a silicon photomultiplier(SiPM) and multiphotodiode(PD) with different active areas has been proposed. A prototype readout system that adopts multichannel charge measurement ASICs was also developed to read out the combined system of SiPMs and PDs. Preliminary tests confirmed the feasibility of the readout scheme, which is expected to have a dynamic range close to 10~6.
基金supported by the National Natural Science Foundation of China(Nos.U2031206,U1831206,11975292,11875304)the Scientific Instrument Developing Project of the Chinese Academy of Sciences(No.GJJSTD20210009)+1 种基金the CAS“Light of West China”Programthe CAS Pioneer Hundred Talent Program。
文摘China plans to develop the next generation dark matter particle explorer satellite,referred to as the Very Large Area Space Telescope(VLAST).As an essential step in this process,the prototype design of detectors and electronics for the VLAST is currently underway.The nuclide detector is a core detector in the VLAST.It mainly measures nuclides’charges and distinguishes high-energy gamma rays and electrons.This paper will discuss the prototype readout electronics for the VLAST’s nuclide detector,which accurately measures the charge signal of the photomultiplier tubes using the VATA160 applicationspecific integrated circuit chip;furthermore,we consider a series of critical problems,including radiation-hardening and environment monitoring.The test results show that the system exhibits stable operation,good performance,and good technical indicators.Furthermore,each electronic channel achieves a dynamic range of 0-12.5 pC,the random noise level exceeds 1.6 fC,and the integral nonlinearity exceeds 0.35%.
基金supported by the Large High Altitude Air Shower Observatory (LHAASO) Project
文摘The ASIC is widely used in the field of high energy physics. Astroparticle experiments benefit from high integration, smallsize and low power consumption. In this paper an analog chip named ARCHGARD (Analog Readout Chip for High energyGamma Ray Detector) for high energy physics experiment is introduced. ARCHGARD is a readout chip, in chartered 0.35 mSiGe technology, for photomultipliers (PMT) array readout. The chip is designed for the Large High Altitude Air Shower Ob-servatory (LHAASO) project. The ASIC integrates 16 independent and auto-triggered channels with variable gain and variableshaping time. It provides analog output for charge measurement, which is performed from 1 up to 3000 photo-electrons (p.e.).The integral nonlinearity of the whole input range is less than 1% and the equivalent input noise is less than 1/10 p.e. Eachchannel has a trigger output for time measurement.