When an underground structure passes through a liquefiable soil layer,the soil liquefaction may pose a significant threat to the structure.A centrifuge shaking table test was performed to research the seismic response...When an underground structure passes through a liquefiable soil layer,the soil liquefaction may pose a significant threat to the structure.A centrifuge shaking table test was performed to research the seismic response of underground structures in liquefiable interlayer sites,and a valid numerical model was obtained through simulation model test.Finally,the calibrated numerical model was used to perform further research on the influence of various distribution characteristics of liquefiable interlayers on the seismic reaction of underground structures.The key findings are as follows.The structure faces the most unfavorable condition once a liquefiable layer is located in the middle of the underground structure.When a liquefiable layer exists in the middle of the structure,the seismic reactions of both the underground structure and model site will increase with the rise of the thickness of the liquefiable interlayer.The inter-story drift of the structure in the non-liquefiable site is much smaller than that in the liquefiable interlayer site.The inter-story drift of the structure is not only associated with the site displacement and the soil-structure stiffness ratio but also closely associated with the slippage of the soil-structure contact interface under the condition of large deformation of the site.展开更多
Taizhou Bridge is the first kilometer level three-pylon two-span suspension bridge in the world and the structural complexity has significant effects on the seismic performance of the bridge. Shaking table test of Tai...Taizhou Bridge is the first kilometer level three-pylon two-span suspension bridge in the world and the structural complexity has significant effects on the seismic performance of the bridge. Shaking table test of Taizhou Bridge is arranged to investigate the effects of non-uniform ground motion input, collision between main and side spans and optimal seismic structural system. It's very important and difficult to design and manufacture the scaled down model of Taizhou Bridge used during the shaking table test. The key point is that the girder and pylons are very hard to be manufactured if the similarity ratio is strictly followed. Based on the finite element method (FEM) analysis, a simplified scaled down model is designed and the bending stiffness of the girder and pylon are strictly simulated, and the torsion stiffness and axial stiffness are not strictly simulated. The inner forces and displacements of critical sections, points of simplified model and theoretical model are compared by FEM analysis, and it's found out that the difference between the seismic responses is relatively small. So, the simplified model can be used to conduct the shaking table test by the FEM verification.展开更多
Adopting a soft site model built on soft interlayer soil foundation,a shaking table test for soft interlayer soil-isolated structure interaction is conducted to investigate the seismic response of isolated structure o...Adopting a soft site model built on soft interlayer soil foundation,a shaking table test for soft interlayer soil-isolated structure interaction is conducted to investigate the seismic response of isolated structure on soft site,and analyze its isolation effect.Test results show that the test can reflect the earthquake response characteristics of isolated structure on soft site.It is on soft site that the dynamic characteristics of isolated structure,acceleration magnification factor(AMF)of isolated structure and isolation efficiency of the isolation layer differ from those on rigid foundation with an soil-structure interaction(SSI)effect,represented by the reduction in fundamental vibration frequency of isolated structure and the increase of damping ratio with changes of the SSI effect.SSI can either increase or decrease AMF of isolated structure on soft site,depending on the characteristics of earthquake motion input.Furthermore,the isolation efficiency of isolation layer on soft site is decreased with the SSI effect,which is related to the peak ground acceleration(PGA)and the characteristics of earthquake motion input.展开更多
The success of the tuned mass damper (TMD) in reducing wind-induced structural vibrations has been well established. However, from most of the recent numerical studies, it appears that for a structure situated on very...The success of the tuned mass damper (TMD) in reducing wind-induced structural vibrations has been well established. However, from most of the recent numerical studies, it appears that for a structure situated on very soft soil, soil-structure interaction (SSI) could render a damper on the structure totally ineffective. In order to experimentally verify the SSI effect on the seismic performance of TMD, a series of shaking table model tests have been conducted and the results are presented in this paper. It has been shown that the TMD is not as effective in controlling the seismic responses of structures built on soft soil sites due to the SSI effect. Some test results also show that a TMD device might have a negative impact if the SSI effect is neglected and the structure is built on a soft soil site. For structures constructed on a soil foundation, this research verifies that the SSI effect must be carefully understood before a TMD control system is designed to determine if the control is necessary and if the SSI effect must be considered when choosing the optimal parameters of the TMD device.展开更多
A wind turbine system equipped with a tuned liquid column damper (TLCD) is comprehensively studied via shaking table tests using a 1/13-scaled model. The effects of wind and wave actions are considered by inputting ...A wind turbine system equipped with a tuned liquid column damper (TLCD) is comprehensively studied via shaking table tests using a 1/13-scaled model. The effects of wind and wave actions are considered by inputting response- equivalent accelerations on the shaking table. The test results show that the control effect of the TLCD system is significant in reducing the responses under both wind-wave equivalent loads and ground motions, but obviously varies for different inputs, Further, a blade-hub-tower integrated numerical model for the wind turbine system is established. The model is capable of considering the rotational effect of blades by combining Kane's equation with the finite element method. The responses of the wind tower equipped with TLCD devices are numerically obtained and compared to the test results, showing that under both controlled and uncontrolled conditions with and without blades' rotation, the corresponding responses exhibit good agreement. This demonstrates that the proposed numerical model performs well in capturing the wind-wave coupled response of the offshore wind turbine systems under control. Both numerical and experimental results show that the TLCD system can significantly reduce the structural response and thus improve the safety and serviceability of the offshore wind turbine tower systems. Additional issues that require further study are discussed.展开更多
Many single-tower reinforced concrete core wall-steel frame (RCC-SF) buildings have been built in China, but there are no buildings of different-height multi-tower hybrid system. A multi-tower RCC-SF tall building w...Many single-tower reinforced concrete core wall-steel frame (RCC-SF) buildings have been built in China, but there are no buildings of different-height multi-tower hybrid system. A multi-tower RCC-SF tall building was thus studied because of its structural complexity and irregularity. First, a 1/15 scaled model structure was designed and tested on the shake table under minor, moderate, and major earthquake levels. Then, the dynamic responses of the model structure were interpreted to those of the prototype structure according to the similitude theory. Experimental results demonstrate that, despite the complexity of the structure, the lateral deformation bends as the "bending type" and the RC core walls contribute more than the steel frames to resist seismic loads. The maximum inter-story drift of the complex building under minor earthquakes is slightly beyond the elastic limitation specified in the Chinese code, and meets code requirements under major earthquakes. From the test results some suggestions are provided that could contribute favorable effect on the seismic behavior and the displacement of the building.展开更多
The model test of seismic simulation shaking table is an important method to study the seismic design of bridge structure. In order to evaluate the seismic response and dynamic characteristics of pile-water-pier syste...The model test of seismic simulation shaking table is an important method to study the seismic design of bridge structure. In order to evaluate the seismic response and dynamic characteristics of pile-water-pier system for developing more reliable design procedures, shaking table model tests of a submerged bridge pier system, including pile groups-cap-pier and inertia mass, were conducted. Since different similitude laws corresponding to different test objectives affected the validity of test results, the similitude law with the aim to consider the effect of hydrodynamic pressure was proposed and confirmed through an actual example. Based on the test results, the effect of water around model on seismic response under seismic excitation input was analyzed and the failure level was judged by observing the variation of basic frequency. The test results indicate that the transfer function of analytical model with water is different from that without water, the natural frequency without water is always higher than that with water, and the first modal shapes are various. It is also concluded that the similitude law is suitable for practical application and the dynamic characteristics and seismic response of the structure system can be changed because of the existence of the surrounding water, which should be paid much attention in the further investigation.展开更多
To understand the deformational behaviours of geosynthetics-reinforced soil retaining walls(GRS RWs),a series of plane-strain shaking table tests was conducted on retaining wall models.The backfill of the models was m...To understand the deformational behaviours of geosynthetics-reinforced soil retaining walls(GRS RWs),a series of plane-strain shaking table tests was conducted on retaining wall models.The backfill of the models was made of poorly graded gravel.Deformations and strains in the gravelly backfill induced by seismic loading are recorded in real time,which are of importance to understand the seismic strength and stability of the GRS RW systems,as strain localisation development in the backfill and foundation is related to the degree of strength degradation of the system.In the present study,we aimed at quantifying the induced deformations of the GRS RW models due to shaking.Digital image correlation(DIC)technique was then employed to analyse and provide full-field deformation and motion images with the models.It is demonstrated that,unlike conventional contact devices that are yet limited to provide quantities of a singular and fixed location,DIC provides deformation and motion of the area of interests to reveal the evolution of localisation.展开更多
基金National Natural Science Foundation of China under Grant No.52078020。
文摘When an underground structure passes through a liquefiable soil layer,the soil liquefaction may pose a significant threat to the structure.A centrifuge shaking table test was performed to research the seismic response of underground structures in liquefiable interlayer sites,and a valid numerical model was obtained through simulation model test.Finally,the calibrated numerical model was used to perform further research on the influence of various distribution characteristics of liquefiable interlayers on the seismic reaction of underground structures.The key findings are as follows.The structure faces the most unfavorable condition once a liquefiable layer is located in the middle of the underground structure.When a liquefiable layer exists in the middle of the structure,the seismic reactions of both the underground structure and model site will increase with the rise of the thickness of the liquefiable interlayer.The inter-story drift of the structure in the non-liquefiable site is much smaller than that in the liquefiable interlayer site.The inter-story drift of the structure is not only associated with the site displacement and the soil-structure stiffness ratio but also closely associated with the slippage of the soil-structure contact interface under the condition of large deformation of the site.
基金National Science and Technology Support Program of China(No.2009BAG15B01)Key Programs for Science and Technology Development of Chinese Transportation Industry(No.2008-353-332-190)+2 种基金Natural Science Foundation of China(No.50708074)the Ministry of Science and Technology of China(No.SLDRCE08-B-04)Kwang-Hua Fund for College of Civil Engineering,Tongji University
文摘Taizhou Bridge is the first kilometer level three-pylon two-span suspension bridge in the world and the structural complexity has significant effects on the seismic performance of the bridge. Shaking table test of Taizhou Bridge is arranged to investigate the effects of non-uniform ground motion input, collision between main and side spans and optimal seismic structural system. It's very important and difficult to design and manufacture the scaled down model of Taizhou Bridge used during the shaking table test. The key point is that the girder and pylons are very hard to be manufactured if the similarity ratio is strictly followed. Based on the finite element method (FEM) analysis, a simplified scaled down model is designed and the bending stiffness of the girder and pylon are strictly simulated, and the torsion stiffness and axial stiffness are not strictly simulated. The inner forces and displacements of critical sections, points of simplified model and theoretical model are compared by FEM analysis, and it's found out that the difference between the seismic responses is relatively small. So, the simplified model can be used to conduct the shaking table test by the FEM verification.
基金supported by the Jiangsu Natural Science Foundation of China(Grant No.BK2012477)the Science Research Foundation of Nanjing Institute of Technology(CKJA201505,JCYJ201618)
文摘Adopting a soft site model built on soft interlayer soil foundation,a shaking table test for soft interlayer soil-isolated structure interaction is conducted to investigate the seismic response of isolated structure on soft site,and analyze its isolation effect.Test results show that the test can reflect the earthquake response characteristics of isolated structure on soft site.It is on soft site that the dynamic characteristics of isolated structure,acceleration magnification factor(AMF)of isolated structure and isolation efficiency of the isolation layer differ from those on rigid foundation with an soil-structure interaction(SSI)effect,represented by the reduction in fundamental vibration frequency of isolated structure and the increase of damping ratio with changes of the SSI effect.SSI can either increase or decrease AMF of isolated structure on soft site,depending on the characteristics of earthquake motion input.Furthermore,the isolation efficiency of isolation layer on soft site is decreased with the SSI effect,which is related to the peak ground acceleration(PGA)and the characteristics of earthquake motion input.
基金National Natural Science Foundation of China Under Grant No.59778027State Key Laboratory of Coastal Offshore EngineeringDalian University of Technology Under Grant No.9702
文摘The success of the tuned mass damper (TMD) in reducing wind-induced structural vibrations has been well established. However, from most of the recent numerical studies, it appears that for a structure situated on very soft soil, soil-structure interaction (SSI) could render a damper on the structure totally ineffective. In order to experimentally verify the SSI effect on the seismic performance of TMD, a series of shaking table model tests have been conducted and the results are presented in this paper. It has been shown that the TMD is not as effective in controlling the seismic responses of structures built on soft soil sites due to the SSI effect. Some test results also show that a TMD device might have a negative impact if the SSI effect is neglected and the structure is built on a soft soil site. For structures constructed on a soil foundation, this research verifies that the SSI effect must be carefully understood before a TMD control system is designed to determine if the control is necessary and if the SSI effect must be considered when choosing the optimal parameters of the TMD device.
基金National Natural Science Foundation of China Under Grant No.11172210National Hi-Tech Development Plan(863 Plan)Under Grant No.2008AA05Z413+2 种基金the Fundamental Fund for Central Universitiesthe Shuguang Program of Shanghai Citythe State Key Laboratory of Disaster Reduction in Civil Engineering Under Grant Nos.SLDRCE14-A-06 and SLDRCE14-B-17
文摘A wind turbine system equipped with a tuned liquid column damper (TLCD) is comprehensively studied via shaking table tests using a 1/13-scaled model. The effects of wind and wave actions are considered by inputting response- equivalent accelerations on the shaking table. The test results show that the control effect of the TLCD system is significant in reducing the responses under both wind-wave equivalent loads and ground motions, but obviously varies for different inputs, Further, a blade-hub-tower integrated numerical model for the wind turbine system is established. The model is capable of considering the rotational effect of blades by combining Kane's equation with the finite element method. The responses of the wind tower equipped with TLCD devices are numerically obtained and compared to the test results, showing that under both controlled and uncontrolled conditions with and without blades' rotation, the corresponding responses exhibit good agreement. This demonstrates that the proposed numerical model performs well in capturing the wind-wave coupled response of the offshore wind turbine systems under control. Both numerical and experimental results show that the TLCD system can significantly reduce the structural response and thus improve the safety and serviceability of the offshore wind turbine tower systems. Additional issues that require further study are discussed.
基金National Natural Science Foundation of China Under Grant No. 50708071National Basic Research of China Under Grant No. 2007CB714202+1 种基金National Key Technology R&D Program Under Grant No. 2006BAJ13B01Shanghai Educational Development Foundation Under Grant No. 2007CG27
文摘Many single-tower reinforced concrete core wall-steel frame (RCC-SF) buildings have been built in China, but there are no buildings of different-height multi-tower hybrid system. A multi-tower RCC-SF tall building was thus studied because of its structural complexity and irregularity. First, a 1/15 scaled model structure was designed and tested on the shake table under minor, moderate, and major earthquake levels. Then, the dynamic responses of the model structure were interpreted to those of the prototype structure according to the similitude theory. Experimental results demonstrate that, despite the complexity of the structure, the lateral deformation bends as the "bending type" and the RC core walls contribute more than the steel frames to resist seismic loads. The maximum inter-story drift of the complex building under minor earthquakes is slightly beyond the elastic limitation specified in the Chinese code, and meets code requirements under major earthquakes. From the test results some suggestions are provided that could contribute favorable effect on the seismic behavior and the displacement of the building.
基金National Basic Research Program of China ("973" Program,No.2011CB013605-4)National Natural Science Foundation of China(No.51178079)Major Program of National Natural Science Foundation of China (No.90915011)
文摘The model test of seismic simulation shaking table is an important method to study the seismic design of bridge structure. In order to evaluate the seismic response and dynamic characteristics of pile-water-pier system for developing more reliable design procedures, shaking table model tests of a submerged bridge pier system, including pile groups-cap-pier and inertia mass, were conducted. Since different similitude laws corresponding to different test objectives affected the validity of test results, the similitude law with the aim to consider the effect of hydrodynamic pressure was proposed and confirmed through an actual example. Based on the test results, the effect of water around model on seismic response under seismic excitation input was analyzed and the failure level was judged by observing the variation of basic frequency. The test results indicate that the transfer function of analytical model with water is different from that without water, the natural frequency without water is always higher than that with water, and the first modal shapes are various. It is also concluded that the similitude law is suitable for practical application and the dynamic characteristics and seismic response of the structure system can be changed because of the existence of the surrounding water, which should be paid much attention in the further investigation.
基金the Japan Society for the Promotion of Science and their financial support through the JSPS Fellowship Programme to conduct research activities at the University of Tokyo.
文摘To understand the deformational behaviours of geosynthetics-reinforced soil retaining walls(GRS RWs),a series of plane-strain shaking table tests was conducted on retaining wall models.The backfill of the models was made of poorly graded gravel.Deformations and strains in the gravelly backfill induced by seismic loading are recorded in real time,which are of importance to understand the seismic strength and stability of the GRS RW systems,as strain localisation development in the backfill and foundation is related to the degree of strength degradation of the system.In the present study,we aimed at quantifying the induced deformations of the GRS RW models due to shaking.Digital image correlation(DIC)technique was then employed to analyse and provide full-field deformation and motion images with the models.It is demonstrated that,unlike conventional contact devices that are yet limited to provide quantities of a singular and fixed location,DIC provides deformation and motion of the area of interests to reveal the evolution of localisation.