The distributed acoustic sensor(DAS)uses a single optical cable as the sensing unit,which can capture the acoustic and vibration signals along the optical cable in real-time.So it is suitable for monitoring downhole p...The distributed acoustic sensor(DAS)uses a single optical cable as the sensing unit,which can capture the acoustic and vibration signals along the optical cable in real-time.So it is suitable for monitoring downhole production activities in the process of oil and gas development.The authors applied the DAS system in a gas production well in the South China Sea for in situ monitoring of the whole wellbore for the first time and obtained the distributed acoustic signals along the whole wellbore.These signals can clearly distinguish the vertical section,curve section,and horizontal production section.The collected acoustic signal with the frequency of approximately 50 Hz caused by the electric submersible pump exhibit a signal-to-noise ratio higher than 27 dB.By analyzing the acoustic signals in the production section,it can be located the layers with high gas production rates.Once an accurate physical model is built in the future,the gas production profile will be obtained.In addition,the DAS system can track the trajectory of downhole tools in the wellbore to guide the operation.Through the velocity analysis of the typical signals,the type of fluids in the wellbore can be distinguished.The successful application of the system provides a promising whole wellbore acoustic monitoring tool for the production of marine gas hydrate,with a good application prospect.展开更多
Based on advantages of technology of distributive fiber-optic temperature sensing and specific to its applications in monitoring mine conflagration, the corresponding Processes such as connection arrangement, signal t...Based on advantages of technology of distributive fiber-optic temperature sensing and specific to its applications in monitoring mine conflagration, the corresponding Processes such as connection arrangement, signal transmission and monitoring were illustrated. As applied in Sitai Coal Mine of Datong Coal Mine Group Co., this method is effective and accurate and could provide reliable gist for monitoring spontaneous combustion in gob area of mines.展开更多
AIMTo evaluate the possible relationship of optic disc area with retina nerve fiber layer in different glaucoma subtypes.METHODSOne eye each was chosen from 45 patients with ocular hypertension, 45 patients with prima...AIMTo evaluate the possible relationship of optic disc area with retina nerve fiber layer in different glaucoma subtypes.METHODSOne eye each was chosen from 45 patients with ocular hypertension, 45 patients with primary open angle glaucoma, 45 patients with pseudoexfoliation glaucoma and 45 healthy controls followed in our hospital. The records of the patients were reviewed retrospectively. Optic disc area and circumpapillary retina nerve fiber layer measurements were obtained using optical coherence tomography. Central corneal thickness was measured by ultrasound pachymetry.RESULTSThe median disc area in the patients with primary open angle glaucoma was significantly higher than the patients with ocular hypertension (2.19 vs 1.90 mm<sup>2</sup>, P=0.030). The median retina nerve fiber layer was thinner in the patients with primary open angle glaucoma and pseudoexfoliation glaucoma than the patients with ocular hypertension for superior, inferior and temporal quadrants. After adjustment for age, no difference in central corneal thickness was found between the groups. Greater disc area was associated with thicker retinal nerve fiber layer for superior, inferior and nasal quadrants in the patients with primary open angle glaucoma. There was no correlation between disc area and central corneal thickness measurements of the groups.CONCLUSIONDisc size affects the retinal nerve fiber layer thickness in eyes with primary open angle glaucoma and is a possible risk factor for glaucomatous optic nerve damage.展开更多
Purpose: To observe the development of optic nerve, we examined four optic nerves from Siameses Twins by absolute counts of axons.Methods: Mean axon diameter, mean axon density, totally axonal population and optic ner...Purpose: To observe the development of optic nerve, we examined four optic nerves from Siameses Twins by absolute counts of axons.Methods: Mean axon diameter, mean axon density, totally axonal population and optic nerve area were noted for each optic nerve. The mean axon diameter and the mean axon density were compared between paraxial (inner sectors)and cortical (outer sectors)areas of the nerves.Results: More myelinated axons were seen in the inner sectors as compared to the outer sectors(average 11 axons/1 000 μm2 in inner sectors and 34 axons/l 000 μm2 in outer sectors( P=0. 036) . The myelinated fibers were also smaller(63 microns) in the outer sectors as compared to the inner sectors(72 microns) ( P = 0. 001 ). The average cross sectors area for the four 40 week stage optical nerves of Siamese Twins was 3.32 × 103 as compared to 1 million axons for 32-week-old normals.Conclusion: Our finding of fewer axonal number and small myelinated fibers in the Siamese Twins suggests hypoplasia. Myelination was more abnormal in the paraxial optic nerve than that in the peripheral sectors, suggesting anomalous development of optic nerve peripherally and delayed developnent centrally. Axonal density is higher in inner sectors than that in outer sectors, suggesting delayed development of the outer nerve sector.展开更多
基金jointly supported by the Science and Technology Program of Guangzhou (202103040003)the offshore NGHs production test projects under the Marine Geological Survey Program initiated by the China Geological Survey (DD20190226, DD20190218 and DD20221706)+2 种基金the Key Program of Marine Economy Development Special Foundation of Department of Natural Resources of Guangdong Province (GDNRC [2020] 045)the financial support from China Geological Survey (DD20221703)the National Natural Science Foundation of China (NSFC) (6210030553)。
文摘The distributed acoustic sensor(DAS)uses a single optical cable as the sensing unit,which can capture the acoustic and vibration signals along the optical cable in real-time.So it is suitable for monitoring downhole production activities in the process of oil and gas development.The authors applied the DAS system in a gas production well in the South China Sea for in situ monitoring of the whole wellbore for the first time and obtained the distributed acoustic signals along the whole wellbore.These signals can clearly distinguish the vertical section,curve section,and horizontal production section.The collected acoustic signal with the frequency of approximately 50 Hz caused by the electric submersible pump exhibit a signal-to-noise ratio higher than 27 dB.By analyzing the acoustic signals in the production section,it can be located the layers with high gas production rates.Once an accurate physical model is built in the future,the gas production profile will be obtained.In addition,the DAS system can track the trajectory of downhole tools in the wellbore to guide the operation.Through the velocity analysis of the typical signals,the type of fluids in the wellbore can be distinguished.The successful application of the system provides a promising whole wellbore acoustic monitoring tool for the production of marine gas hydrate,with a good application prospect.
基金Supported by the National Natural Science Foundation of China (50375026,50375028)
文摘Based on advantages of technology of distributive fiber-optic temperature sensing and specific to its applications in monitoring mine conflagration, the corresponding Processes such as connection arrangement, signal transmission and monitoring were illustrated. As applied in Sitai Coal Mine of Datong Coal Mine Group Co., this method is effective and accurate and could provide reliable gist for monitoring spontaneous combustion in gob area of mines.
文摘AIMTo evaluate the possible relationship of optic disc area with retina nerve fiber layer in different glaucoma subtypes.METHODSOne eye each was chosen from 45 patients with ocular hypertension, 45 patients with primary open angle glaucoma, 45 patients with pseudoexfoliation glaucoma and 45 healthy controls followed in our hospital. The records of the patients were reviewed retrospectively. Optic disc area and circumpapillary retina nerve fiber layer measurements were obtained using optical coherence tomography. Central corneal thickness was measured by ultrasound pachymetry.RESULTSThe median disc area in the patients with primary open angle glaucoma was significantly higher than the patients with ocular hypertension (2.19 vs 1.90 mm<sup>2</sup>, P=0.030). The median retina nerve fiber layer was thinner in the patients with primary open angle glaucoma and pseudoexfoliation glaucoma than the patients with ocular hypertension for superior, inferior and temporal quadrants. After adjustment for age, no difference in central corneal thickness was found between the groups. Greater disc area was associated with thicker retinal nerve fiber layer for superior, inferior and nasal quadrants in the patients with primary open angle glaucoma. There was no correlation between disc area and central corneal thickness measurements of the groups.CONCLUSIONDisc size affects the retinal nerve fiber layer thickness in eyes with primary open angle glaucoma and is a possible risk factor for glaucomatous optic nerve damage.
文摘Purpose: To observe the development of optic nerve, we examined four optic nerves from Siameses Twins by absolute counts of axons.Methods: Mean axon diameter, mean axon density, totally axonal population and optic nerve area were noted for each optic nerve. The mean axon diameter and the mean axon density were compared between paraxial (inner sectors)and cortical (outer sectors)areas of the nerves.Results: More myelinated axons were seen in the inner sectors as compared to the outer sectors(average 11 axons/1 000 μm2 in inner sectors and 34 axons/l 000 μm2 in outer sectors( P=0. 036) . The myelinated fibers were also smaller(63 microns) in the outer sectors as compared to the inner sectors(72 microns) ( P = 0. 001 ). The average cross sectors area for the four 40 week stage optical nerves of Siamese Twins was 3.32 × 103 as compared to 1 million axons for 32-week-old normals.Conclusion: Our finding of fewer axonal number and small myelinated fibers in the Siamese Twins suggests hypoplasia. Myelination was more abnormal in the paraxial optic nerve than that in the peripheral sectors, suggesting anomalous development of optic nerve peripherally and delayed developnent centrally. Axonal density is higher in inner sectors than that in outer sectors, suggesting delayed development of the outer nerve sector.