In order to improve the dynamic stability of precision instruments during the design process, a compositive design method based on modal analysis of structure is proposed. With uniform boundary conditions and material...In order to improve the dynamic stability of precision instruments during the design process, a compositive design method based on modal analysis of structure is proposed. With uniform boundary conditions and material characters, the results of Finite Element Analysis (FEA) vary with models. It should be checked whether the model is correctly simplified. Modal experiments can be used for such purpose. The method combines the high efficiency and agility of FEA with the reliability and accuracy of experiments, and avoids the drawbacks of FEA or experiments, such as uncertainty of FEA and high cost of experiments. Taking rotor frame structure as an example, this method is applied as follows: First the modal characters of structure are analyzed with FEA, and then the natural frequencies of the structure are tested by experiments to check the reliability of FEA method, and finally the design scheme is optimized by modifying structure parameters with confirmed FEA.展开更多
Since the proposal of the concept of photonic integratedcircuits (PICs), tremendous progress has been made. In2005, Infinera Corp. rolled out the first commercial PICs, inwhich hundreds of optical functions were integ...Since the proposal of the concept of photonic integratedcircuits (PICs), tremendous progress has been made. In2005, Infinera Corp. rolled out the first commercial PICs, inwhich hundreds of optical functions were integrated onto asmall form factor chip for wavelength division multiplexing(WDM) systems[1], then a monolithically integrated 10 ×10 Gb/s WDM chip has been demonstrated, the channelnumber is ten[2]. Like ICs, large-scale PICs (LS-PICs) will besure to be pursued. However, there are still some generalchallenges associated with LS-PICs. The challenges for III–V(mainly InP) PICs is the semiconductor process, which is notmature for LS-PICs. Up to now, the channel number in commercialIII–V WDM PICs by Infinera is still about ten or less.For silicon photonics, the challenge is the silicon based lightsource. The low cost and mature solution for silicon lasers isstill unavailable and only 4 × 25 Gb/s PICs are deployed byIntel Corp. after 18-year R&D investment. Thus it is still unavailablefor practical LS-PICs in the present times.展开更多
In this paper, we presented a method of using the l as er scanning triangulation for the non-contact 3D surface profile measurement of large-scale object. The characteristic of large-scale object non-contact mea surem...In this paper, we presented a method of using the l as er scanning triangulation for the non-contact 3D surface profile measurement of large-scale object. The characteristic of large-scale object non-contact mea surement is analyzed and the measuring method is proposed. Main factors influenc ing measurement precision such as image distortion and accurate designation of s peckle center are analyzed and methods of solving these problems are proposed. W e designed a combined filter by which the pulse noise and the Gaussian noise of speckle image can be eliminated efficiently. Using the characteristic of intensi ty distribution of laser speckle image we proposed a new approximating method th at could locate the center of laser speckle image at sub-pixel. The auxiliary v ariables are set to linearize the relationship between the image displacement an d the distance, the accurate values of laser triangulation system parameters cou ld be calibrated accurately and the measuring precision is increased remarkabl y. Using the above techniques we designed a measuring system based on laser sc anning triangulation. The results of the experiment show that these methods can raise the measuring precision of large-scale 3D surface profile effectively.展开更多
A new solution of combination network of GPS and high precise distance measurements with EDM is proposed. Meanwhile, it’s inadvisable only using GPS network without distance measurements. Three schemes: terrestrial n...A new solution of combination network of GPS and high precise distance measurements with EDM is proposed. Meanwhile, it’s inadvisable only using GPS network without distance measurements. Three schemes: terrestrial network, GPS network and combination network are discussed for horizontal control network design of Xiangjiaba Dam in view of precision, reliability, coordinate and outlay in detail.展开更多
The article introduces the main practices and achievements of the Environment and Plant Protection Institute of Chinese Academy of Tropical Agricultural Sciences in promoting the sharing of large-scale instruments and...The article introduces the main practices and achievements of the Environment and Plant Protection Institute of Chinese Academy of Tropical Agricultural Sciences in promoting the sharing of large-scale instruments and equipment in recent years,analyzes the existing problems in the management system,management team,assessment incentives and maintenance guarantee,and proposes improvement measures and suggestions from aspects of improving the sharing management system,strengthening management team building,strengthening sharing assessment and incentives,improving maintenance capabilities and expanding external publicity,to further improve the sharing management of large-scale instruments and equipment.展开更多
With determination micro-Fe by 1, 10-phenanthroline spectrophotometry for example, they are systematically introduced the combinatorial measurement and regression analysis method application about metheodic principle,...With determination micro-Fe by 1, 10-phenanthroline spectrophotometry for example, they are systematically introduced the combinatorial measurement and regression analysis method application about metheodic principle, operation step and data processing in the instrumental analysis, including: calibration curve best linear equation is set up, measurand best linear equation is set up, and calculation of best value of a concentration. The results showed that mean of thrice determination , s = 0 μg/mL, RSD = 0. Results of preliminary application are simply introduced in the basic instrumental analysis for atomic absorption spectrophotometry, ion-selective electrodes, coulometry and polarographic analysis and are contrasted to results of normal measurements.展开更多
We developed a measuring instrument that had wide range, high precision, small measuring touch force. The instrument for three-dimensional (3D) surface topography measurement was composed of a high precision displacem...We developed a measuring instrument that had wide range, high precision, small measuring touch force. The instrument for three-dimensional (3D) surface topography measurement was composed of a high precision displacement sensor based on the Michelson interference principle, a 3D platform based on vertical scanning, a measuring and control circuit, and an industrial control computer. It was a closed loop control system, which changed the traditional moving stylus scanning style into a moving platform scanning style. When the workpiece was measured, the lever of the displacement sensor returned to the balanced position in every sample interval according to the zero offset of the displacement sensor. The non-linear error caused by the rotation of the lever was, therefore, very small even if the measuring range was wide. The instrument can measure the roughness and the profile size of a curved surface.展开更多
In this paper, we conduct research on the large precision instrument error correction model under the perspectives of stability androbustness. It is one of the effective methods to improve the instruments accuracy usi...In this paper, we conduct research on the large precision instrument error correction model under the perspectives of stability androbustness. It is one of the effective methods to improve the instruments accuracy using error correction technology, but at present, a lot of errorcorrection is limited to the system error modifi cation, only a small number of the instruments to an error in the dynamic error correction timely,device on the instrument precision sensors, apparently complicate the instrument structure. To fully system error correction that will affect theprecision of instrument mainly random error. Instrument is the main task of error correction is to use a certain method to compensate separableinstruments each component part of a deterministic system error, so the key problems of error correction as is the requirement of equipmentstructure stability is good, with this to ensure that the instrument error of the uncertainty, so that the fundamental fl aw. Under this basis, this paperproposes the novel countermeasure of the issues that is innovative.展开更多
In this paper, we conduct research on precision instrument reliability and anti-interference mode from the intrusion detectionangle based on rough set. Ultra-precision machining applications range from soft metal to h...In this paper, we conduct research on precision instrument reliability and anti-interference mode from the intrusion detectionangle based on rough set. Ultra-precision machining applications range from soft metal to hardened steel, stainless steel, high speed steel,cemented carbide and some other hard processing material, to the semiconductor, glass, ceramics and the other hard brittle non-metallic materials,almost all materials available ultra-precision machining technology for the processing. To enhance the robustness of the mentioned equipment,we consider the integration of the rough set and intrusion detection to modify the corresponding issues that will optimize the traditional methodsfrom systematical level which holds special signifi cance.展开更多
To improve the reliability of the light emitting diode(LED)signal lamp filament current monitoring alarm instrument for metro systems,a new type of hot standby online monitoring apparatus was developed which is based ...To improve the reliability of the light emitting diode(LED)signal lamp filament current monitoring alarm instrument for metro systems,a new type of hot standby online monitoring apparatus was developed which is based on synchronous transmission data(STD)bus technology.In this system,a double hot standby mode can be achieved by adopting bus arbitration.In addition,to detect the effective value of alternating current which is from 0 to 200 mA in the signal lamp lighting circuit,a precision rectifier signal conditioning circuit and an isolated acquisition circuit were designed.This new type of alarm instrument has high detection accuracy and could meet the functional requirements for metro signal systems after comparing it with some industry products that were applied on the spot.展开更多
In recent years,the usage,management and benefit of large-scale scientific research instruments and equipment in scientific research institutes have been a leading issue in the management of scientific research instit...In recent years,the usage,management and benefit of large-scale scientific research instruments and equipment in scientific research institutes have been a leading issue in the management of scientific research institutes.Within the scope of equipment budget,it is necessary for each equipment acquisition team to conduct a round of communication,coordination and negotiation with suppliers in order to improve the cost performance of equipment procurement and maximize the performance index to meet the needs of scientific research.By introducing the practical experience of the State Key Laboratory in purchasing imported equipment and managing large-scale instruments,this paper probes into the management process of the imported large-scale scientific research tax-free equipment of scientific research institutes,and explores the system and methods to guarantee and improve the efficiency of large-scale instruments in scientific research institutes from the aspects of policy,funds and technology.展开更多
The Jiao Tong University Spectroscopic Telescope(JUST)is a 4.4-meter f/6.0 segmented-mirror telescope dedicated to spectroscopic observations.The JUST primary mirror is composed of 18 hexagonal segments,each with a di...The Jiao Tong University Spectroscopic Telescope(JUST)is a 4.4-meter f/6.0 segmented-mirror telescope dedicated to spectroscopic observations.The JUST primary mirror is composed of 18 hexagonal segments,each with a diameter of 1.1 m.JUST provides two Nasmyth platforms for placing science instruments.One Nasmyth focus fits a field of view of 10′and the other has an extended field of view of 1.2°with correction optics.A tertiary mirror is used to switch between the two Nasmyth foci.JUST will be installed at a site at Lenghu in Qinghai Province,China,and will conduct spectroscopic observations with three types of instruments to explore the dark universe,trace the dynamic universe,and search for exoplanets:(1)a multi-fiber(2000 fibers)medium-resolution spectrometer(R=4000-5000)to spectroscopically map galaxies and large-scale structure;(2)an integral field unit(IFU)array of 500 optical fibers and/or a long-slit spectrograph dedicated to fast follow-ups of transient sources for multi-messenger astronomy;(3)a high-resolution spectrometer(R~100000)designed to identify Jupiter analogs and Earth-like planets,with the capability to characterize the atmospheres of hot exoplanets.展开更多
文摘In order to improve the dynamic stability of precision instruments during the design process, a compositive design method based on modal analysis of structure is proposed. With uniform boundary conditions and material characters, the results of Finite Element Analysis (FEA) vary with models. It should be checked whether the model is correctly simplified. Modal experiments can be used for such purpose. The method combines the high efficiency and agility of FEA with the reliability and accuracy of experiments, and avoids the drawbacks of FEA or experiments, such as uncertainty of FEA and high cost of experiments. Taking rotor frame structure as an example, this method is applied as follows: First the modal characters of structure are analyzed with FEA, and then the natural frequencies of the structure are tested by experiments to check the reliability of FEA method, and finally the design scheme is optimized by modifying structure parameters with confirmed FEA.
文摘Since the proposal of the concept of photonic integratedcircuits (PICs), tremendous progress has been made. In2005, Infinera Corp. rolled out the first commercial PICs, inwhich hundreds of optical functions were integrated onto asmall form factor chip for wavelength division multiplexing(WDM) systems[1], then a monolithically integrated 10 ×10 Gb/s WDM chip has been demonstrated, the channelnumber is ten[2]. Like ICs, large-scale PICs (LS-PICs) will besure to be pursued. However, there are still some generalchallenges associated with LS-PICs. The challenges for III–V(mainly InP) PICs is the semiconductor process, which is notmature for LS-PICs. Up to now, the channel number in commercialIII–V WDM PICs by Infinera is still about ten or less.For silicon photonics, the challenge is the silicon based lightsource. The low cost and mature solution for silicon lasers isstill unavailable and only 4 × 25 Gb/s PICs are deployed byIntel Corp. after 18-year R&D investment. Thus it is still unavailablefor practical LS-PICs in the present times.
文摘In this paper, we presented a method of using the l as er scanning triangulation for the non-contact 3D surface profile measurement of large-scale object. The characteristic of large-scale object non-contact mea surement is analyzed and the measuring method is proposed. Main factors influenc ing measurement precision such as image distortion and accurate designation of s peckle center are analyzed and methods of solving these problems are proposed. W e designed a combined filter by which the pulse noise and the Gaussian noise of speckle image can be eliminated efficiently. Using the characteristic of intensi ty distribution of laser speckle image we proposed a new approximating method th at could locate the center of laser speckle image at sub-pixel. The auxiliary v ariables are set to linearize the relationship between the image displacement an d the distance, the accurate values of laser triangulation system parameters cou ld be calibrated accurately and the measuring precision is increased remarkabl y. Using the above techniques we designed a measuring system based on laser sc anning triangulation. The results of the experiment show that these methods can raise the measuring precision of large-scale 3D surface profile effectively.
基金Supported bythe National 973 Programof China(No.2003CB716705) International Cooperative Fund of European Union(No.EVGI-CT-2002-00061) .
文摘A new solution of combination network of GPS and high precise distance measurements with EDM is proposed. Meanwhile, it’s inadvisable only using GPS network without distance measurements. Three schemes: terrestrial network, GPS network and combination network are discussed for horizontal control network design of Xiangjiaba Dam in view of precision, reliability, coordinate and outlay in detail.
文摘The article introduces the main practices and achievements of the Environment and Plant Protection Institute of Chinese Academy of Tropical Agricultural Sciences in promoting the sharing of large-scale instruments and equipment in recent years,analyzes the existing problems in the management system,management team,assessment incentives and maintenance guarantee,and proposes improvement measures and suggestions from aspects of improving the sharing management system,strengthening management team building,strengthening sharing assessment and incentives,improving maintenance capabilities and expanding external publicity,to further improve the sharing management of large-scale instruments and equipment.
文摘With determination micro-Fe by 1, 10-phenanthroline spectrophotometry for example, they are systematically introduced the combinatorial measurement and regression analysis method application about metheodic principle, operation step and data processing in the instrumental analysis, including: calibration curve best linear equation is set up, measurand best linear equation is set up, and calculation of best value of a concentration. The results showed that mean of thrice determination , s = 0 μg/mL, RSD = 0. Results of preliminary application are simply introduced in the basic instrumental analysis for atomic absorption spectrophotometry, ion-selective electrodes, coulometry and polarographic analysis and are contrasted to results of normal measurements.
基金the National Science Foundation of China (No.50745020).
文摘We developed a measuring instrument that had wide range, high precision, small measuring touch force. The instrument for three-dimensional (3D) surface topography measurement was composed of a high precision displacement sensor based on the Michelson interference principle, a 3D platform based on vertical scanning, a measuring and control circuit, and an industrial control computer. It was a closed loop control system, which changed the traditional moving stylus scanning style into a moving platform scanning style. When the workpiece was measured, the lever of the displacement sensor returned to the balanced position in every sample interval according to the zero offset of the displacement sensor. The non-linear error caused by the rotation of the lever was, therefore, very small even if the measuring range was wide. The instrument can measure the roughness and the profile size of a curved surface.
文摘In this paper, we conduct research on the large precision instrument error correction model under the perspectives of stability androbustness. It is one of the effective methods to improve the instruments accuracy using error correction technology, but at present, a lot of errorcorrection is limited to the system error modifi cation, only a small number of the instruments to an error in the dynamic error correction timely,device on the instrument precision sensors, apparently complicate the instrument structure. To fully system error correction that will affect theprecision of instrument mainly random error. Instrument is the main task of error correction is to use a certain method to compensate separableinstruments each component part of a deterministic system error, so the key problems of error correction as is the requirement of equipmentstructure stability is good, with this to ensure that the instrument error of the uncertainty, so that the fundamental fl aw. Under this basis, this paperproposes the novel countermeasure of the issues that is innovative.
文摘In this paper, we conduct research on precision instrument reliability and anti-interference mode from the intrusion detectionangle based on rough set. Ultra-precision machining applications range from soft metal to hardened steel, stainless steel, high speed steel,cemented carbide and some other hard processing material, to the semiconductor, glass, ceramics and the other hard brittle non-metallic materials,almost all materials available ultra-precision machining technology for the processing. To enhance the robustness of the mentioned equipment,we consider the integration of the rough set and intrusion detection to modify the corresponding issues that will optimize the traditional methodsfrom systematical level which holds special signifi cance.
文摘To improve the reliability of the light emitting diode(LED)signal lamp filament current monitoring alarm instrument for metro systems,a new type of hot standby online monitoring apparatus was developed which is based on synchronous transmission data(STD)bus technology.In this system,a double hot standby mode can be achieved by adopting bus arbitration.In addition,to detect the effective value of alternating current which is from 0 to 200 mA in the signal lamp lighting circuit,a precision rectifier signal conditioning circuit and an isolated acquisition circuit were designed.This new type of alarm instrument has high detection accuracy and could meet the functional requirements for metro signal systems after comparing it with some industry products that were applied on the spot.
文摘In recent years,the usage,management and benefit of large-scale scientific research instruments and equipment in scientific research institutes have been a leading issue in the management of scientific research institutes.Within the scope of equipment budget,it is necessary for each equipment acquisition team to conduct a round of communication,coordination and negotiation with suppliers in order to improve the cost performance of equipment procurement and maximize the performance index to meet the needs of scientific research.By introducing the practical experience of the State Key Laboratory in purchasing imported equipment and managing large-scale instruments,this paper probes into the management process of the imported large-scale scientific research tax-free equipment of scientific research institutes,and explores the system and methods to guarantee and improve the efficiency of large-scale instruments in scientific research institutes from the aspects of policy,funds and technology.
基金This work is supported by“the Fundamental Research Funds for the Central Universities”,111 project No.B20019Shanghai Natural Science Foundation,grant No.19ZR1466800.
文摘The Jiao Tong University Spectroscopic Telescope(JUST)is a 4.4-meter f/6.0 segmented-mirror telescope dedicated to spectroscopic observations.The JUST primary mirror is composed of 18 hexagonal segments,each with a diameter of 1.1 m.JUST provides two Nasmyth platforms for placing science instruments.One Nasmyth focus fits a field of view of 10′and the other has an extended field of view of 1.2°with correction optics.A tertiary mirror is used to switch between the two Nasmyth foci.JUST will be installed at a site at Lenghu in Qinghai Province,China,and will conduct spectroscopic observations with three types of instruments to explore the dark universe,trace the dynamic universe,and search for exoplanets:(1)a multi-fiber(2000 fibers)medium-resolution spectrometer(R=4000-5000)to spectroscopically map galaxies and large-scale structure;(2)an integral field unit(IFU)array of 500 optical fibers and/or a long-slit spectrograph dedicated to fast follow-ups of transient sources for multi-messenger astronomy;(3)a high-resolution spectrometer(R~100000)designed to identify Jupiter analogs and Earth-like planets,with the capability to characterize the atmospheres of hot exoplanets.