In order to improve the dynamic stability of precision instruments during the design process, a compositive design method based on modal analysis of structure is proposed. With uniform boundary conditions and material...In order to improve the dynamic stability of precision instruments during the design process, a compositive design method based on modal analysis of structure is proposed. With uniform boundary conditions and material characters, the results of Finite Element Analysis (FEA) vary with models. It should be checked whether the model is correctly simplified. Modal experiments can be used for such purpose. The method combines the high efficiency and agility of FEA with the reliability and accuracy of experiments, and avoids the drawbacks of FEA or experiments, such as uncertainty of FEA and high cost of experiments. Taking rotor frame structure as an example, this method is applied as follows: First the modal characters of structure are analyzed with FEA, and then the natural frequencies of the structure are tested by experiments to check the reliability of FEA method, and finally the design scheme is optimized by modifying structure parameters with confirmed FEA.展开更多
With determination micro-Fe by 1, 10-phenanthroline spectrophotometry for example, they are systematically introduced the combinatorial measurement and regression analysis method application about metheodic principle,...With determination micro-Fe by 1, 10-phenanthroline spectrophotometry for example, they are systematically introduced the combinatorial measurement and regression analysis method application about metheodic principle, operation step and data processing in the instrumental analysis, including: calibration curve best linear equation is set up, measurand best linear equation is set up, and calculation of best value of a concentration. The results showed that mean of thrice determination , s = 0 μg/mL, RSD = 0. Results of preliminary application are simply introduced in the basic instrumental analysis for atomic absorption spectrophotometry, ion-selective electrodes, coulometry and polarographic analysis and are contrasted to results of normal measurements.展开更多
We developed a measuring instrument that had wide range, high precision, small measuring touch force. The instrument for three-dimensional (3D) surface topography measurement was composed of a high precision displacem...We developed a measuring instrument that had wide range, high precision, small measuring touch force. The instrument for three-dimensional (3D) surface topography measurement was composed of a high precision displacement sensor based on the Michelson interference principle, a 3D platform based on vertical scanning, a measuring and control circuit, and an industrial control computer. It was a closed loop control system, which changed the traditional moving stylus scanning style into a moving platform scanning style. When the workpiece was measured, the lever of the displacement sensor returned to the balanced position in every sample interval according to the zero offset of the displacement sensor. The non-linear error caused by the rotation of the lever was, therefore, very small even if the measuring range was wide. The instrument can measure the roughness and the profile size of a curved surface.展开更多
文摘In order to improve the dynamic stability of precision instruments during the design process, a compositive design method based on modal analysis of structure is proposed. With uniform boundary conditions and material characters, the results of Finite Element Analysis (FEA) vary with models. It should be checked whether the model is correctly simplified. Modal experiments can be used for such purpose. The method combines the high efficiency and agility of FEA with the reliability and accuracy of experiments, and avoids the drawbacks of FEA or experiments, such as uncertainty of FEA and high cost of experiments. Taking rotor frame structure as an example, this method is applied as follows: First the modal characters of structure are analyzed with FEA, and then the natural frequencies of the structure are tested by experiments to check the reliability of FEA method, and finally the design scheme is optimized by modifying structure parameters with confirmed FEA.
文摘With determination micro-Fe by 1, 10-phenanthroline spectrophotometry for example, they are systematically introduced the combinatorial measurement and regression analysis method application about metheodic principle, operation step and data processing in the instrumental analysis, including: calibration curve best linear equation is set up, measurand best linear equation is set up, and calculation of best value of a concentration. The results showed that mean of thrice determination , s = 0 μg/mL, RSD = 0. Results of preliminary application are simply introduced in the basic instrumental analysis for atomic absorption spectrophotometry, ion-selective electrodes, coulometry and polarographic analysis and are contrasted to results of normal measurements.
基金the National Science Foundation of China (No.50745020).
文摘We developed a measuring instrument that had wide range, high precision, small measuring touch force. The instrument for three-dimensional (3D) surface topography measurement was composed of a high precision displacement sensor based on the Michelson interference principle, a 3D platform based on vertical scanning, a measuring and control circuit, and an industrial control computer. It was a closed loop control system, which changed the traditional moving stylus scanning style into a moving platform scanning style. When the workpiece was measured, the lever of the displacement sensor returned to the balanced position in every sample interval according to the zero offset of the displacement sensor. The non-linear error caused by the rotation of the lever was, therefore, very small even if the measuring range was wide. The instrument can measure the roughness and the profile size of a curved surface.