Lingual nerve injury caused by laryngeal mask airway during percutaneous nephrolithotomy:A case report 被引量:1
1
作者 Zheng-Yi Wang Wan-Zhang Liu +4 位作者 Feng-Qi Wang Ying-Zhi Chen Ting Huang He-Sheng Yuan Yue Cheng 《World Journal of Clinical Cases》 SCIE 2021年第35期11095-11101,共7页
BACKGROUND Lingual nerve injury(LNI)is a rare complication following the use of laryngeal mask airway(LMA).The occurrence of this unexpected complication causes uncomfortable symptoms in patients and worsens their qua... BACKGROUND Lingual nerve injury(LNI)is a rare complication following the use of laryngeal mask airway(LMA).The occurrence of this unexpected complication causes uncomfortable symptoms in patients and worsens their quality of life.We present an unusual case of LNI caused by the use of an LMA in percutaneous nephrolithotomy(PCNL).CASE SUMMARY A 49-year-old man presented to our hospital with a 3-year history of intermittent left lower back pain.Abdominal computed tomography showed a 25 mm×20 mm stone in the left renal pelvis.PCNL surgery using LMA was performed to remove the renal stone.The patient reported numbness on the tip of his tongue after the operation,but there were no signs of swelling or trauma.The patient was diagnosed with LNI after other possible causes were ruled out.The symptom of numbness eventually improved after conservative medical therapy for 1 wk.The patient completely recovered 3 wk after surgery.CONCLUSION This is the first case report describing LNI with the use of LMA in PCNL.In our case,an inappropriate LMA size,intraoperative movement,and a specific surgical position might be potential causes of this rare complication. 展开更多
关键词 Lingual nerve injury laryngeal mask airway Percutaneous nephrolithotomy Case report
下载PDF
Severe gastric insufflation and consequent atelectasis caused by gas leakage using AIR-Q laryngeal mask airway:A case report
2
作者 Yue Zhao Ping Li +2 位作者 De-Wei Li Gao-Feng Zhao Xiang-Yu Li 《World Journal of Clinical Cases》 SCIE 2022年第11期3541-3546,共6页
BACKGROUND The airways of patients undergoing awake craniotomy(AC)are considered“predicted difficult airways”,inclined to be managed with supraglottic airway devices(SADs)to lower the risk of coughing or gagging.How... BACKGROUND The airways of patients undergoing awake craniotomy(AC)are considered“predicted difficult airways”,inclined to be managed with supraglottic airway devices(SADs)to lower the risk of coughing or gagging.However,the special requirements of AC in the head and neck position may deteriorate SADs’seal performance,which increases the risks of ventilation failure,severe gastric insufflation,regurgitation,and aspiration.CASE SUMMARY A 41-year-old man scheduled for AC with the asleep–awake–asleep approach was anesthetized and ventilated with a size 3.5 AIR-Q intubating laryngeal mask airway(LMA).Air leak was noticed with adequate ventilation after head rotation for allowing scalp blockage.Twenty-five minutes later,the LMA was replaced by an endotracheal tube because of a change in the surgical plan.After surgery,the patient consistently showed low tidal volume and was diagnosed with gastric insufflation and atelectasis using computed tomography.CONCLUSION This case highlights head rotation may cause gas leakage,severe gastric insufflation,and consequent atelectasis during ventilation with an AIR-Q intubating laryngeal airway. 展开更多
关键词 INSUFFLATION ATELECTASIS laryngeal mask airway CRANIOTOMY Case report
下载PDF
Effect of different types of laryngeal mask airway placement on the right internal jugular vein: A prospective randomized controlled trial
3
作者 Jing-Jing Zhang Zong-Yang Qu +2 位作者 Zhen Hua Ming-Zhang Zuo Hong-Ye Zhang 《World Journal of Clinical Cases》 SCIE 2019年第24期4245-4253,共9页
BACKGROUND In recent years, with the popularity of laryngeal mask airway(LMA) for the management of clinical anesthesia, the influence of the LMA on the position and blood flow of the internal jugular vein(IJV) has at... BACKGROUND In recent years, with the popularity of laryngeal mask airway(LMA) for the management of clinical anesthesia, the influence of the LMA on the position and blood flow of the internal jugular vein(IJV) has attracted an increasing amount of attention.AIM To investigate the effect of placement of different types of LMA(Supreme LMA,Guardian LMA, I-gel LMA) on the position and blood flow of the right IJV.METHODS This was a prospective randomized controlled trial. A total of 102 patients aged 18-75 years who were scheduled to undergo laparoscopic abdominal surgery with general anesthesia were randomly assigned to three groups: Supreme LMA(group 1), Guardian LMA(group 2), and I-gel LMA(group 3) groups. The main indicator was the overlap index(OI) of IJV and the common carotid artery(CCA)at the high, middle, and low points before and after the placement of the LMA.The second indicators were the proportion of ultrasound-simulated needle crossing the IJV and CCA, and the cross-sectional area and blood flow velocity of the IJV before and after placement of the LMA at the middle point.RESULTS Data from 100 patients were included in the statistical analysis. The OI increased significantly after placement of the LMA in the three groups at the three points(P< 0.01), except group 2 at the low point. In group 2 and group 3, the OI was lower than that in group 1 after LMA insertion at the high point(P < 0.0167). At the middle point, after LMA insertion, the proportion of simulated needle crossing the IJV significantly decreased in all three groups(P < 0.05), and the proportion in group 2 was higher than that in group 3(P < 0.0167). The proportion of simulated needle crossing the CCA or both the IJV and CCA significantly increased in group 1 and group 2(P < 0.05), which increased with no statistical significance in group 3. After LMA insertion, the cross-sectional area of the IJV significantly increased, while the blood flow velocity significantly decreased(P <0.01). There was no significant difference among the three groups.CONCLUSION The placement of Supreme, Guardian, and I-gel LMA can increase the OI, reduce the success rate of IJV puncture, increase the incidence of arterial puncture, and cause congestion of IJV. Type of LMA did not influence the difficulty of IJV puncture. Therefore when LMA is used, ultrasound is recommended to guide the IJV puncture. 展开更多
关键词 laryngeal mask airway Internal jugular vein Common carotid artery Blood flow
下载PDF
Investigating the Fluid Seal of Supraglottic Airway Devices in Humans Using Indicator Dye via the Drainage Tube:A Potential Roadmap for Future Studies
4
作者 Sebastian G.Russo Stephan Cremer +3 位作者 Ulrike Muhlhauser Christoph Eich Michael Quintel Martin Bauer 《Open Journal of Anesthesiology》 2012年第2期18-22,共5页
Background: The fluid seal of supraglottic airway devices (SGA) protects the airway from fluid contamination. We evaluated the suitability of indicator dye placement in the upper digestive tract of anesthetized patien... Background: The fluid seal of supraglottic airway devices (SGA) protects the airway from fluid contamination. We evaluated the suitability of indicator dye placement in the upper digestive tract of anesthetized patients combined with fiberoptical tracing to investigate the fluid seal of SGA. Methods: Patients swallowed a capsule of indigo carmine green (ICG) prior to induction of anaesthesia. After induction of anesthesia, one of two different SGA (either an i-GelTM or an LMA-SupremeTM (LMA-S)) was inserted after randomization. Methylene blue stained normal saline was injected through the proximal opening of drainage tube during mechanical ventilation as well as spontaneous breathing. We monitored regurgitation of ICG with a flexible fiberscope (FO) inserted through the drainage tube and checked for the appearance of methylene blue in the mask bowl with the FO inserted through the airway tube. Results: In thirty-six patients with an i-GelTM and 37 with a LMA-S no regurgitation of ICG was observed at the level of the upper oesophageal sphincter (UES). Methylene blue stained saline was not visible in any patient during pressure-controlled ventilation, but was detected in two of the 36 patients with the i-GelTM during spontaneous breathing. Conclusion: Instilling dye through the drainage tube of SGA models with a built-in drainage tube represents a useful method to examine and to compare the fluid seal of different SGA. Our protocol presented in this study proved to be an easy and reproducible approach for future studies. Furthermore, the clinical results gained during this evaluation highlight the necessity for further investigations regarding the fluid seal competencies of SGAs in humans under clinical conditions. 展开更多
关键词 laryngeal mask airway Supraglottic airway ASPIRATION
下载PDF