The dissolution kinetics of Al_(2)O_(3) in CaO-Al_(2)O_(3) SiOslags was studied using a high-temperature confocal scanning laser microscope at 1773 to 1873 K.The results show that the controlling step during the Al_(2...The dissolution kinetics of Al_(2)O_(3) in CaO-Al_(2)O_(3) SiOslags was studied using a high-temperature confocal scanning laser microscope at 1773 to 1873 K.The results show that the controlling step during the Al_(2)O_(3) dissolution was the diffusionin molten slag.It was found that the dissolution curves of Al_(2)O_(3) particles were hardly agreed with the traditional boundary layer diffusion model with the increase of the CaO/Al_(2)O_(3) ratio of slag.A modified diffusion equation considering slag viscosity was developed to study the dissolution mechanism of Al_(2)O_(3) in slag.Diffusion coefficients of Al_(2)O_(3) in slag were calculated as 2.8×10to 4.1×10m~2/s at the temperature of 1773-1873 K.The dissolution rate of Al_(2)O_(3) increased with higher temperature,CaO/Al_(2)O_(3),and particle size.A new model was shown to be v_(Al_(2)O_(3))=0.16×r_(0)^(1.58)×x^(3.52)×(T-T_(mp))^(1.11)to predict the dissolution rate and the total dissolution time of Al_(2)O_(3) inclusions with various sizes,where vAl_(2)O_(3) is the dissolution rate of Al_(2)O_(3) in volume,μm^(3)/s;x is the value of CaO/Al_(2)O_(3) mass ratio;R_(0) is the initial radius of Al_(2)O_(3),μm;T is the temperature,K;T_(mp) is the melting point of slag,K.展开更多
To investigate the bacterial colonization on zirconium oxide and titanium surfaces in vivo quantitatively using a confocal laser scanning microscope (CLSM). Ten samples of zirconium oxide ceramic and commercially pure...To investigate the bacterial colonization on zirconium oxide and titanium surfaces in vivo quantitatively using a confocal laser scanning microscope (CLSM). Ten samples of zirconium oxide ceramic and commercially pure titanium were fabricated and polished using silicon carbide abrasive paper. One sample from each group was evaluated topographic pattern under a scanning electron microscope. One sample from each group was to evaluate roughness using a profilometer. Eight volunteers were selected. The samples were cemented at the buccal surfaces of upper first molars. All samples were removed after 48 hours, immersed in SYTO-9 and propidium iodide fluorescent to stain for adherent bacteria and observed with CLSM. Fewer bacteria were observed in zirconia group than titanium group. However, there was no statistical difference between two groups. The experimental results demonstrate that zirconium oxide may be considered as a promising material for dental implant abutments.展开更多
Aim: 1] Comparative evaluation of the linear depth of induced remineralized lesions after subjecting to fluoride supplements and 2] To assess the average fluorescence at both the demineralized and the remi-neralized z...Aim: 1] Comparative evaluation of the linear depth of induced remineralized lesions after subjecting to fluoride supplements and 2] To assess the average fluorescence at both the demineralized and the remi-neralized zones in all the three study groups under confocal laser scanning microscope. Method: Forty five sound human premolars extracted for orthodon-tic reasons were decoronated 1 mm below the ce-mento-enamel junction and coated with nail varnish except for a 3 × 3 mm window on the buccal surface. The samples were placed in 50 ml of de mineralizing solution at pH 4.6 for 96 hours. Following deminera-lization, the lower half of the 3 × 3 mm window in all the samples were covered with nail varnish to serve as control. The samples were randomly divided into three groups of fifteen teeth each (n = 15) and speci-mens in group A[Nfd] were remineralized using non-fluoridated dentifrice [control], those in groups B [Fd5] and group C [Fd10] using 500 ppm and 1000 ppm of fluoride containing dentifrice, respectively. The specimens were subjected to a 20 day reminera-lization treatment regimen and were sectioned into 100 μm thick sections and two images were captured on the buccal surface from either side of the midpoint of occluso-cervical length using confocal laser scan-ning microscope [CLSM]. Results: were tabulated and statistically analyzed by Anova. Study concluded that 1000 ppm fluoridated dentifrice showed a greater degree of remineralization than other groups and confocal laser scanning microscopes gives promising results in the diagnosis of early enamel lesions over the conventional methods.展开更多
A new Quantum Dots(Qdots) nanocrystal composed of semiconductor core and zinc sulfide shell, and its feasibility as labels in immunofluorescence analysis for the imaging of tumor biomarkers by laser scanning confocal ...A new Quantum Dots(Qdots) nanocrystal composed of semiconductor core and zinc sulfide shell, and its feasibility as labels in immunofluorescence analysis for the imaging of tumor biomarkers by laser scanning confocal microscope(LSCM) was investigated. Qdots taged by mercaptoacetic acid were conjugated with second antibody, then imaging differences of Heat Shock Proteins 70(HSP70) in renal carcinoma tissure sections with immunofluorescence analysis method using Qdots bioconjugates and conventional organic dye FITC were observed by LSCM to assess the brightness and opticalstability of Qdots. The experimental results showed Qdots bioconjugates achieved the better results in demonstrating HSP70 with more brighter color and more clear picture than FITC labels. Moreover, the label signals of Qdots did not fade clearly after continued exposure to a 488 nm laser for 1 h. The Qdots bioconjugates have good feasibility in immunofluorescence analysis for the bioimaging by LSCM.展开更多
The level of lipid peroxidation and cellular necrosis in rat living brain slices during brain ischemia-hypoxia injury have been observed using a laser confocal scanning microscope (LCSM) with double labeling of fluore...The level of lipid peroxidation and cellular necrosis in rat living brain slices during brain ischemia-hypoxia injury have been observed using a laser confocal scanning microscope (LCSM) with double labeling of fluorescent probes D-399 (2, 7-dichlorofluorescin diacetate) and propidium iodide (Pl). The hypoxia and/or reoxygenation injury in rat brain slices is markedly decreased by pretreatment with L-NG-nitro-arginine (L-NNA) and N-acetylcysteine (NAC), showing that the nitric oxide (NO) and other free radicals play an important role in brain ischemia-hypoxia injury.展开更多
Two kinds of TiO_2 filled epoxy coatings were designed and prepared to obtain pigments with different dispersion degrees of TiO_2 particles.Laser scanning confocal microscope(LSCM)was used to investigate both the hori...Two kinds of TiO_2 filled epoxy coatings were designed and prepared to obtain pigments with different dispersion degrees of TiO_2 particles.Laser scanning confocal microscope(LSCM)was used to investigate both the horizontal and vertical distributions of TiO_2 particles in the coatings.The results indicated that TiO_2 in the two samples shared considerable similarity in horizental dispersion,but exhibited great difference in vertical dispersion.TiO_2 showed uniform vertical distribution in disp coating,wheras a gap about 1.1μm was found in the non-disp coating,which significantly influenced the surface optical properties of the coatings during weathering.Based on the confocal data,the model of dispersion of pigments in the coatings was proposed and the change of surface properties during weathering was predicted:the surface optical properties showed an initial decrease followed by a subsequent increase,which was in good agreement with the weathering data.展开更多
激光扫描共聚焦显微镜是生物、医药、化学等科学领域成像研究的一个重要工具,也是目前大型仪器平台不可或缺的成像设备。LSM900 with Airyscan2是目前市面上较新的一款多功能、快速、高分辨率的激光扫描共聚焦显微镜。对激光扫描共聚焦...激光扫描共聚焦显微镜是生物、医药、化学等科学领域成像研究的一个重要工具,也是目前大型仪器平台不可或缺的成像设备。LSM900 with Airyscan2是目前市面上较新的一款多功能、快速、高分辨率的激光扫描共聚焦显微镜。对激光扫描共聚焦显微镜的原理、其运行的环境要求、管理人员职责、开放共享管理以及设备维护保养注意事项几方面做详细地介绍,供相关管理人员与使用者参考。展开更多
Existing technologies used to detect monosodium urate(MSU)crystals for gout diagnosis are not ideal due to their low sensitivity and complexity of operation.The purpose of this study was to explore whether aggregation...Existing technologies used to detect monosodium urate(MSU)crystals for gout diagnosis are not ideal due to their low sensitivity and complexity of operation.The purpose of this study was to explore whether aggregation-induced emission luminogens(AIEgens)can be used for highly specific imaging of MSU crystals to assist in the diagnosis of gout.First,we developed a series of luminogens(i.e.,tetraphenyl ethylene(TPE)-NH_(2),TPE-2NH_(2),TPE-4NH_(2),TPE-COOH,TPE-2COOH,TPE-4COOH,and TPE-Ketoalkyne),each of which was then evenly mixed with MSU crystals.Next,optimal fluorescence imaging of each of the luminogens was characterized by a confocal laser scanning microscope(CLSM).This approach was used for imaging standard samples of MSU,hydroxyapatite(HAP)crystals,and mixed samples with 1:1 mass ratio of MSU/HAP.We also imaged samples from mouse models of acute gouty arthritis,HAP deposition disease,and comorbidities of interest.Subsequently,CLSM imaging results were compared with those of compensated polarized light microscopy,and we assessed the biosafety of TPE-Ketoalkyne in the RAW264.7 cell line.Finally,CLSM time series and three-dimensional imaging were performed on MSU crystal samples from human gouty synovial fluid and tophi.As a promising candidate for MSU crystal labeling,TPE-Ketoalkyne was found to detect MSU crystals accurately and rapidly in standard samples,animal samples,and human samples,and could precisely distinguish gout from HAP deposition disease.This work demonstrates that TPE-Ketoalkyne is suitable for highly specific and timely imaging of MSU crystals in gouty arthritis and may facilitate future research on MSU crystal-related diseases.展开更多
基金financially supported by the National Nature Science Foundation of China(Nos.U1860206,51725402)the Science and Technology Program of Hebei,China(Nos.20311006D,20591001D)。
文摘The dissolution kinetics of Al_(2)O_(3) in CaO-Al_(2)O_(3) SiOslags was studied using a high-temperature confocal scanning laser microscope at 1773 to 1873 K.The results show that the controlling step during the Al_(2)O_(3) dissolution was the diffusionin molten slag.It was found that the dissolution curves of Al_(2)O_(3) particles were hardly agreed with the traditional boundary layer diffusion model with the increase of the CaO/Al_(2)O_(3) ratio of slag.A modified diffusion equation considering slag viscosity was developed to study the dissolution mechanism of Al_(2)O_(3) in slag.Diffusion coefficients of Al_(2)O_(3) in slag were calculated as 2.8×10to 4.1×10m~2/s at the temperature of 1773-1873 K.The dissolution rate of Al_(2)O_(3) increased with higher temperature,CaO/Al_(2)O_(3),and particle size.A new model was shown to be v_(Al_(2)O_(3))=0.16×r_(0)^(1.58)×x^(3.52)×(T-T_(mp))^(1.11)to predict the dissolution rate and the total dissolution time of Al_(2)O_(3) inclusions with various sizes,where vAl_(2)O_(3) is the dissolution rate of Al_(2)O_(3) in volume,μm^(3)/s;x is the value of CaO/Al_(2)O_(3) mass ratio;R_(0) is the initial radius of Al_(2)O_(3),μm;T is the temperature,K;T_(mp) is the melting point of slag,K.
基金Funded by the National Natural Science Foundation of China(No.81271179)the Scientific Research Foundation for Returned Scholars,Ministry of Education of China(No.(2011)1568)the Science and Technology Program of Shanghai Pudong New Area Health Bureau(No.PW2010A-14)
文摘To investigate the bacterial colonization on zirconium oxide and titanium surfaces in vivo quantitatively using a confocal laser scanning microscope (CLSM). Ten samples of zirconium oxide ceramic and commercially pure titanium were fabricated and polished using silicon carbide abrasive paper. One sample from each group was evaluated topographic pattern under a scanning electron microscope. One sample from each group was to evaluate roughness using a profilometer. Eight volunteers were selected. The samples were cemented at the buccal surfaces of upper first molars. All samples were removed after 48 hours, immersed in SYTO-9 and propidium iodide fluorescent to stain for adherent bacteria and observed with CLSM. Fewer bacteria were observed in zirconia group than titanium group. However, there was no statistical difference between two groups. The experimental results demonstrate that zirconium oxide may be considered as a promising material for dental implant abutments.
文摘Aim: 1] Comparative evaluation of the linear depth of induced remineralized lesions after subjecting to fluoride supplements and 2] To assess the average fluorescence at both the demineralized and the remi-neralized zones in all the three study groups under confocal laser scanning microscope. Method: Forty five sound human premolars extracted for orthodon-tic reasons were decoronated 1 mm below the ce-mento-enamel junction and coated with nail varnish except for a 3 × 3 mm window on the buccal surface. The samples were placed in 50 ml of de mineralizing solution at pH 4.6 for 96 hours. Following deminera-lization, the lower half of the 3 × 3 mm window in all the samples were covered with nail varnish to serve as control. The samples were randomly divided into three groups of fifteen teeth each (n = 15) and speci-mens in group A[Nfd] were remineralized using non-fluoridated dentifrice [control], those in groups B [Fd5] and group C [Fd10] using 500 ppm and 1000 ppm of fluoride containing dentifrice, respectively. The specimens were subjected to a 20 day reminera-lization treatment regimen and were sectioned into 100 μm thick sections and two images were captured on the buccal surface from either side of the midpoint of occluso-cervical length using confocal laser scan-ning microscope [CLSM]. Results: were tabulated and statistically analyzed by Anova. Study concluded that 1000 ppm fluoridated dentifrice showed a greater degree of remineralization than other groups and confocal laser scanning microscopes gives promising results in the diagnosis of early enamel lesions over the conventional methods.
基金Funded by the National Natural Science Foundation of China (No.303711325)
文摘A new Quantum Dots(Qdots) nanocrystal composed of semiconductor core and zinc sulfide shell, and its feasibility as labels in immunofluorescence analysis for the imaging of tumor biomarkers by laser scanning confocal microscope(LSCM) was investigated. Qdots taged by mercaptoacetic acid were conjugated with second antibody, then imaging differences of Heat Shock Proteins 70(HSP70) in renal carcinoma tissure sections with immunofluorescence analysis method using Qdots bioconjugates and conventional organic dye FITC were observed by LSCM to assess the brightness and opticalstability of Qdots. The experimental results showed Qdots bioconjugates achieved the better results in demonstrating HSP70 with more brighter color and more clear picture than FITC labels. Moreover, the label signals of Qdots did not fade clearly after continued exposure to a 488 nm laser for 1 h. The Qdots bioconjugates have good feasibility in immunofluorescence analysis for the bioimaging by LSCM.
文摘The level of lipid peroxidation and cellular necrosis in rat living brain slices during brain ischemia-hypoxia injury have been observed using a laser confocal scanning microscope (LCSM) with double labeling of fluorescent probes D-399 (2, 7-dichlorofluorescin diacetate) and propidium iodide (Pl). The hypoxia and/or reoxygenation injury in rat brain slices is markedly decreased by pretreatment with L-NG-nitro-arginine (L-NNA) and N-acetylcysteine (NAC), showing that the nitric oxide (NO) and other free radicals play an important role in brain ischemia-hypoxia injury.
基金supported by the National Natural Science Foundation of China(Grant Nos.20944004,50943026)the Open Research Program of the Key Laboratory of Rubber-Plastic(QUST),the Ministry of Education of China(Grant No.0805021)the PhD Research Program of QUST(Grant No.0022200)
文摘Two kinds of TiO_2 filled epoxy coatings were designed and prepared to obtain pigments with different dispersion degrees of TiO_2 particles.Laser scanning confocal microscope(LSCM)was used to investigate both the horizontal and vertical distributions of TiO_2 particles in the coatings.The results indicated that TiO_2 in the two samples shared considerable similarity in horizental dispersion,but exhibited great difference in vertical dispersion.TiO_2 showed uniform vertical distribution in disp coating,wheras a gap about 1.1μm was found in the non-disp coating,which significantly influenced the surface optical properties of the coatings during weathering.Based on the confocal data,the model of dispersion of pigments in the coatings was proposed and the change of surface properties during weathering was predicted:the surface optical properties showed an initial decrease followed by a subsequent increase,which was in good agreement with the weathering data.
文摘激光扫描共聚焦显微镜是生物、医药、化学等科学领域成像研究的一个重要工具,也是目前大型仪器平台不可或缺的成像设备。LSM900 with Airyscan2是目前市面上较新的一款多功能、快速、高分辨率的激光扫描共聚焦显微镜。对激光扫描共聚焦显微镜的原理、其运行的环境要求、管理人员职责、开放共享管理以及设备维护保养注意事项几方面做详细地介绍,供相关管理人员与使用者参考。
基金Thisworkwas supported by the Shanghai Science and Technology Committee(No.22dz1204700)the NationalKeyR&D Program of China(Nos.2020YFA0803800 and 2017YFE0132200)+2 种基金the National Natural Science Foundation of China(Nos.82072510,21907034,21788102,21525417,and 51620105009)the Natural Science Foundation of Guangdong Province(Nos.2019B030301003 and 2016A030312002)the Innovation and Technology Commission of Hong Kong(No.ITC-CNERC14S01).
文摘Existing technologies used to detect monosodium urate(MSU)crystals for gout diagnosis are not ideal due to their low sensitivity and complexity of operation.The purpose of this study was to explore whether aggregation-induced emission luminogens(AIEgens)can be used for highly specific imaging of MSU crystals to assist in the diagnosis of gout.First,we developed a series of luminogens(i.e.,tetraphenyl ethylene(TPE)-NH_(2),TPE-2NH_(2),TPE-4NH_(2),TPE-COOH,TPE-2COOH,TPE-4COOH,and TPE-Ketoalkyne),each of which was then evenly mixed with MSU crystals.Next,optimal fluorescence imaging of each of the luminogens was characterized by a confocal laser scanning microscope(CLSM).This approach was used for imaging standard samples of MSU,hydroxyapatite(HAP)crystals,and mixed samples with 1:1 mass ratio of MSU/HAP.We also imaged samples from mouse models of acute gouty arthritis,HAP deposition disease,and comorbidities of interest.Subsequently,CLSM imaging results were compared with those of compensated polarized light microscopy,and we assessed the biosafety of TPE-Ketoalkyne in the RAW264.7 cell line.Finally,CLSM time series and three-dimensional imaging were performed on MSU crystal samples from human gouty synovial fluid and tophi.As a promising candidate for MSU crystal labeling,TPE-Ketoalkyne was found to detect MSU crystals accurately and rapidly in standard samples,animal samples,and human samples,and could precisely distinguish gout from HAP deposition disease.This work demonstrates that TPE-Ketoalkyne is suitable for highly specific and timely imaging of MSU crystals in gouty arthritis and may facilitate future research on MSU crystal-related diseases.